Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39178029

RESUMO

BACKGROUND: Septic cardiomyopathy (SCM) with diastolic dysfunction carries a poor prognosis, and the mechanisms underlying the development of diastolic dysfunction remain unclear. Matrix metalloproteinase-8 (MMP-8) is released from neutrophils and degrades collagen I. MMP-8 levels correlate with SCM severity. OBJECTIVES: We scrutinized, for the first time, the direct impact of MMP-8 on cardiac systolic and diastolic functions. METHODS: Isolated rat hearts were perfused with Krebs-Henseleit solution in a Langendorff setup with computer-controlled filling pressures of both ventricles at isovolumetric regime. The end-diastolic pressure (EDP) varied periodically between 3 and 20 mmHg. After baseline recordings, MMP-8 (100 µg/ml) was added to the perfusion. Short-axis views of both ventricles were continuously acquired by echocardiography. RESULTS: MMP-8 perfusion resulted in progressive decline in peak systolic pressures (Psys) in both ventricles, but without significant changes in their end-systolic pressure-area relationships (ESPARs). Counterintuitively, conspicuous leftward shifts of the end-diastolic pressure-area relationships (EDPARs) were observed in both ventricles. The LV end-diastolic area (EDA) decreased by 32.8±5.7%, (p=0.008), at EDP of 10.5±0.4 mmHg, when LV Psys dropped by 20%. The decline of Psys was primarily due to the decrease in EDA and restoring the baseline EDA by increasing EDP recovered 81.33 ± 5.87% of the pressure drops. CONCLUSION: Collagen I generates tensile (eccentric) stress, and its degradation by MMP-8 causes EDPVR leftward shift, resulting in diastolic and systolic dysfunctions. The diastolic dysfunction explains the clinically observed fluid unresponsiveness, while the decrease in EDV diminishes the systolic functions. MMP-8 can explain the development of SCM with diastolic dysfunction.

2.
Circ Cardiovasc Imaging ; 17(5): e016276, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716653

RESUMO

BACKGROUND: Quantification of left atrial (LA) conduit function and its contribution to left ventricular (LV) filling is challenging because it requires simultaneous measurements of both LA and LV volumes. The functional relationship between LA conduit function and the severity of diastolic dysfunction remains controversial. We studied the role of LA conduit function in maintaining LV filling in advanced diastolic dysfunction. METHODS: We performed volumetric and flow analyses of LA function across the spectrum of LV diastolic dysfunction, derived from a set of consecutive patients undergoing multiphasic cardiac computed tomography scanning (n=489). From LA and LV time-volume curves, we calculated 3 volumetric components: (1) early passive emptying volume; (2) late active (booster) volume; and (3) conduit volume. Results were prospectively validated on a group of patients with severe aortic stenosis (n=110). RESULTS: The early passive filling progressively decreased with worsening diastolic function (P<0.001). The atrial booster contribution to stroke volume modestly increases with impaired relaxation (P=0.021) and declines with more advanced diastolic function (P<0.001), thus failing to compensate for the reduction in early filling. The conduit volume increased progressively (P<0.001), accounting for 75% of stroke volume (interquartile range, 63-81%) with a restrictive filling pattern, compensating for the reduction in both early and booster functions. Similar results were obtained in patients with severe aortic stenosis. The pulmonary artery systolic pressure increased in a near-linear fashion when the conduit contribution to stroke volume increased above 60%. Maximal conduit flow rate strongly correlated with mitral E-wave velocity (r=0.71; P<0.0001), indicating that the increase in mitral E wave in diastolic dysfunction represents the increased conduit flow. CONCLUSIONS: An increase in conduit volume contribution to stroke volume represents a compensatory mechanism to maintain LV filling in advanced diastolic dysfunction. The increase in conduit volume despite increasing LV diastolic pressures is accomplished by an increase in pulmonary venous pressure.


Assuntos
Estenose da Valva Aórtica , Função do Átrio Esquerdo , Diástole , Volume Sistólico , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Função do Átrio Esquerdo/fisiologia , Idoso , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Volume Sistólico/fisiologia , Índice de Gravidade de Doença , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA