Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
2.
Front Cardiovasc Med ; 10: 1112561, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36873407

RESUMO

Background: There is no clear guidance on how to implement opportunistic atrial fibrillation (AF) screening in daily clinical practice. Objectives: This study evaluated the perception of general practitioners (GPs) about value and practicalities of implementing screening for AF, focusing on opportunistic single-time point screening with a single-lead electrocardiogram (ECG) device. Methods: A descriptive cross-sectional study was conducted with a survey developed to assess overall perception concerning AF screening, feasibility of opportunistic single-lead ECG screening and implementation requirements and barriers. Results: A total of 659 responses were collected (36.1% Eastern, 33.4% Western, 12.1% Southern, 10.0% Northern Europe, 8.3% United Kingdom & Ireland). The perceived need for standardized AF screening was rated as 82.7 on a scale from 0 to 100. The vast majority (88.0%) indicated no AF screening program is established in their region. Three out of four GPs (72.1%, lowest in Eastern and Southern Europe) were equipped with a 12-lead ECG, while a single-lead ECG was less common (10.8%, highest in United Kingdom & Ireland). Three in five GPs (59.3%) feel confident ruling out AF on a single-lead ECG strip. Assistance through more education (28.7%) and a tele-healthcare service offering advice on ambiguous tracings (25.2%) would be helpful. Preferred strategies to overcome barriers like insufficient (qualified) staff, included integrating AF screening with other healthcare programs (24.9%) and algorithms to identify patients most suitable for AF screening (24.3%). Conclusion: GPs perceive a strong need for a standardized AF screening approach. Additional resources may be required to have it widely adopted into clinical practice.

3.
J Geriatr Cardiol ; 20(1): 23-31, 2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36875166

RESUMO

OBJECTIVE: Implantable cardiac defibrillators (ICD) implantation in the very elderly remains controversial. We aimed to describe the experience and outcome of patients over 80 years old implanted with an ICD in Belgium. METHODS: Data were extracted from the national QERMID-ICD registry. All implantations performed in octogenarians between February 2010 and March 2019 were analysed. Data on baseline patient characteristics, type of prevention, device configuration and all-cause mortality were available. To determine predictors of mortality, multivariable Cox proportional hazard regression modelling was performed. RESULTS: Nationwide, 704 primo ICD implantations were performed in octogenarians (median age 82, IQR 81-83 years; 83% male and 45% secondary prevention). During a mean follow-up of 3.1 ± 2.3 years, 249 (35%) patients died, of which 76 (11%) within the first year after implantation. In multivariable Cox regression analysis age (HR = 1.15, P = 0.004), oncological history (HR = 2.43, P = 0.027) and secondary prevention (HR = 2.23, P = 0.001) were independently associated with 1-year mortality. A better preserved left ventricular ejection fraction (LVEF) was associated with a better outcome (HR = 0.97, P = 0.002). Regarding overall mortality multivariable analysis withheld age, history of atrial fibrillation, centre volume and oncological history as significant predictors. Higher LVEF was again protective (HR = 0.99, P = 0.008). CONCLUSIONS: Primary ICD implantation in octogenarians is not often performed in Belgium. Among this population, 11% died within the first year after ICD implantation. Advanced age, oncological history, secondary prevention and a lower LVEF were associated with an increased one-year mortality. Age, low LVEF, atrial fibrillation, centre volume and oncological history were indicative of higher overall mortality.

5.
Int J Cardiol Heart Vasc ; 41: 101075, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35782706

RESUMO

Background: The impact of sex on ICD implantation practice and survival remain a topic of controversy. To assess sex-specific differences in ICD implantation practice we compared clinical characteristics and survival in women and men. Methods: From a nationwide registry, all new ICD implantations performed between 01/02/2010 and 31/01/2019 in Belgian patients were analyzed retrospectively. Baseline characteristics and survival rates were compared between sexes. To identify predictors of mortality, multivariable Cox regression was performed. Results: Only 3096 (20.9%) of 14,787 ICD implantations were performed in women. Within each type of underlying cardiomyopathy, the proportion women were lower than men. The main indication in men was ischemic vs dilated cardiomyopathy in women. Women were overall younger (59.1 ± 15.1 vs 62.6 ± 13.1 years; p < 0.001) and had less comorbidities except for oncological disease. More women functioned in NYHA-class III (33.6% vs 27.9%; p < 0.001) and had a QRS > 150 ms (29.4% vs 24.3%; p < 0.001), consistent with a higher use of CRT-D devices (31.7% vs 25.1%; p < 0.001). Women had more complications, reflected by the need to more re-interventions within 1 year (4.3% vs 2.7%, p < 0.001). After correction for covariates, sex-category was not a significant predictor of mortality (p = 0.055). Conclusion: There is a significant sex-disparity in ICD implantation rates, not fully explained by epidemiological differences in the prevalence of cardiomyopathies, which could imply an undertreatment of women. Women differ from men in baseline characteristics at implantation suggesting a selection bias. Further research is necessary to evaluate if women receive equal sudden cardiac death prevention.

6.
Circulation ; 145(5): 392-409, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35100023

RESUMO

Growing evidence suggests a consistent association between atrial fibrillation (AF) and cognitive impairment and dementia that is independent of clinical stroke. This report from the AF-SCREEN International Collaboration summarizes the evidence linking AF to cognitive impairment and dementia. It provides guidance on the investigation and management of dementia in patients with AF on the basis of best available evidence. The document also addresses suspected pathophysiologic mechanisms and identifies knowledge gaps for future research. Whereas AF and dementia share numerous risk factors, the association appears to be independent of these variables. Nevertheless, the evidence remains inconclusive regarding a direct causal effect. Several pathophysiologic mechanisms have been proposed, some of which are potentially amenable to early intervention, including cerebral microinfarction, AF-related cerebral hypoperfusion, inflammation, microhemorrhage, brain atrophy, and systemic atherosclerotic vascular disease. The mitigating role of oral anticoagulation in specific subgroups (eg, low stroke risk, short duration or silent AF, after successful AF ablation, or atrial cardiopathy) and the effect of rhythm versus rate control strategies remain unknown. Likewise, screening for AF (in cognitively normal or cognitively impaired patients) and screening for cognitive impairment in patients with AF are debated. The pathophysiology of dementia and therapeutic strategies to reduce cognitive impairment warrant further investigation in individuals with AF. Cognition should be evaluated in future AF studies and integrated with patient-specific outcome priorities and patient preferences. Further large-scale prospective studies and randomized trials are needed to establish whether AF is a risk factor for cognitive impairment, to investigate strategies to prevent dementia, and to determine whether screening for unknown AF followed by targeted therapy might prevent or reduce cognitive impairment and dementia.


Assuntos
Fibrilação Atrial/fisiopatologia , Demência/fisiopatologia , Humanos , Fatores de Risco
8.
Europace ; 23(7): 983-1008, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33878762

RESUMO

With the global increase in device implantations, there is a growing need to train physicians to implant pacemakers and implantable cardioverter-defibrillators. Although there are international recommendations for device indications and programming, there is no consensus to date regarding implantation technique. This document is founded on a systematic literature search and review, and on consensus from an international task force. It aims to fill the gap by setting standards for device implantation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Ásia , Consenso , Humanos , Estados Unidos
10.
Acta Cardiol ; 76(4): 431-439, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33406996

RESUMO

BACKGROUND: Studies on the use of non-vitamin K antagonist oral anticoagulants in unselected patients with atrial fibrillation (AF) show that clinical characteristics and dosing practices differ per region, but lack data on edoxaban. METHODS: With data from Edoxaban Treatment in routiNe clinical prActice for patients with AF in Europe (ETNA-AF-Europe), a large prospective observational study, we compared clinical characteristics (including the dose reduction criteria for edoxaban: creatinine clearance 15-50 mL/min, weight ≤60 kg, and/or use of strong p-glycoprotein inhibitors) of patients from Belgium and the Netherlands (BeNe) with those from other European countries (OEC). RESULTS: Of all 13,639 patients in ETNA-AF-Europe, 2579 were from BeNe. BeNe patients were younger than OEC patients (mean age: 72.3 vs 73.9 years), and had lower CHA2DS2-VASc (mean: 2.8 vs 3.2) and HAS-BLED scores (mean: 2.4 vs 2.6). Patients from BeNe less often had hypertension (61.6% vs 80.4%), and/or diabetes mellitus (17.3% vs 23.1%) than patients from OEC. Moreover, relatively fewer patients in BeNe were prescribed the reduced dose of 30 mg edoxaban (14.8%) than in OEC (25.4%). Overall, edoxaban was dosed according to label in 83.1% of patients. Yet, 30 mg edoxaban was prescribed in the absence of any dose reduction criteria in 36.9% of 30 mg users (5.5% of all patients) in BeNe compared with 35.5% (9.0% of all patients) in OEC. CONCLUSION: There were several notable differences between BeNe and OEC regarding clinical characteristics and dosing practices in patients prescribed edoxaban, which are relevant for the local implementation of dose evaluation and optimisation. TRIAL REGISTRATION: NCT02944019; Date of registration: October 24, 2016.


Assuntos
Fibrilação Atrial , Inibidores do Fator Xa/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Idoso , Anticoagulantes , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Bélgica/epidemiologia , Europa (Continente)/epidemiologia , Humanos , Países Baixos/epidemiologia , Estudos Prospectivos , Resultado do Tratamento
11.
J Thromb Haemost ; 18(12): 3280-3288, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32886853

RESUMO

BACKGROUND: The uptake rate of non-vitamin K oral anticoagulants (NOAC) for the treatment of non-valvular atrial fibrillation (AF) was far lower in the Netherlands (NL) compared to Belgium (BE). Also, patients on VKA in NL were treated with a higher target international normalized ratio (INR) range of 2.5 to 3.5. OBJECTIVES: To explore the effect of these differences on thromboembolism (TE) and bleeding. METHODS: Data from the GARFIELD-AF registry was used. Patients with new-onset AF and ≥1 investigator-determined risk factor for stroke were included between 2010 and 2016. Event rates from 2 years of follow-up were used. RESULTS: In NL and BE, 1186 and 1705 patients were included, respectively. Female sex (42.3% vs 42.2%), mean age (70.7 vs 71.3 years), CHA2 DS2 -VASc (3.1 vs 3.1), and HAS-BLED score (1.4 vs 1.5) were comparable between NL and BE. At diagnosis in NL vs BE, 72.1% vs 14.6% received vitamin K antagonists (VKA) and 17.8% vs 65.5% NOACs, varying greatly across cohorts. Mean INR was 2.9 (±1.0) and 2.4 (±1.0) in NL and BE, respectively. Event rates per 100 patient-years in NL and BE, respectively, of all-cause mortality (3.38 vs 3.90; hazard ratio [HR] 0.86, 95% confidence interval [CI] 0.65-1.15), ischemic stroke/TE (0.82 vs 0.72; HR 1.14, 95% CI 0.62-2.11), and major bleeding (2.06 vs 1.54; HR 1.33, 95% CI 0.89-1.99) did not differ significantly. CONCLUSIONS: In GARFIELD-AF, despite similar characteristics, patients on anticoagulants were treated differently in NL and BE. Although the rate of major bleeding was 33% higher in NL, variations in bleeding, mortality, and TE rates were not statistically significant.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Bélgica , Feminino , Humanos , Países Baixos , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Vitamina K/uso terapêutico
12.
Circulation ; 140(22): 1834-1850, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31765261

RESUMO

Cardiac thromboembolism attributed to atrial fibrillation (AF) is responsible for up to one-third of ischemic strokes. Stroke may be the first manifestation of previously undetected AF. Given the efficacy of oral anticoagulants in preventing AF-related ischemic strokes, strategies of searching for AF after a stroke using ECG monitoring followed by oral anticoagulation (OAC) treatment have been proposed to prevent recurrent cardioembolic strokes. This white paper by experts from the AF-SCREEN International Collaboration summarizes existing evidence and knowledge gaps on searching for AF after a stroke by using ECG monitoring. New AF can be detected by routine plus intensive ECG monitoring in approximately one-quarter of patients with ischemic stroke. It may be causal, a bystander, or neurogenically induced by the stroke. AF after a stroke is a risk factor for thromboembolism and a strong marker for atrial myopathy. After acute ischemic stroke, patients should undergo 72 hours of electrocardiographic monitoring to detect AF. The diagnosis requires an ECG of sufficient quality for confirmation by a health professional with ECG rhythm expertise. AF detection rate is a function of monitoring duration and quality of analysis, AF episode definition, interval from stroke to monitoring commencement, and patient characteristics including old age, certain ECG alterations, and stroke type. Markers of atrial myopathy (eg, imaging, atrial ectopy, natriuretic peptides) may increase AF yield from monitoring and could be used to guide patient selection for more intensive/prolonged poststroke ECG monitoring. Atrial myopathy without detected AF is not currently sufficient to initiate OAC. The concept of embolic stroke of unknown source is not proven to identify patients who have had a stroke benefitting from empiric OAC treatment. However, some embolic stroke of unknown source subgroups (eg, advanced age, atrial enlargement) might benefit more from non-vitamin K-dependent OAC therapy than aspirin. Fulfilling embolic stroke of unknown source criteria is an indication neither for empiric non-vitamin K-dependent OAC treatment nor for withholding prolonged ECG monitoring for AF. Clinically diagnosed AF after a stroke or a transient ischemic attack is associated with significantly increased risk of recurrent stroke or systemic embolism, in particular, with additional stroke risk factors, and requires OAC rather than antiplatelet therapy. The minimum subclinical AF duration required on ECG monitoring poststroke/transient ischemic attack to recommend OAC therapy is debated.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Eletrocardiografia , Acidente Vascular Cerebral , Tromboembolia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Isquemia Encefálica/complicações , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatologia , Feminino , Humanos , Masculino , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Tromboembolia/diagnóstico , Tromboembolia/fisiopatologia
13.
PLoS Med ; 16(9): e1002903, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31553733

RESUMO

BACKGROUND: The precise age distribution and calculated stroke risk of screen-detected atrial fibrillation (AF) is not known. Therefore, it is not possible to determine the number needed to screen (NNS) to identify one treatable new AF case (NNS-Rx) (i.e., Class-1 oral anticoagulation [OAC] treatment recommendation) in each age stratum. If the NNS-Rx is known for each age stratum, precise cost-effectiveness and sensitivity simulations can be performed based on the age distribution of the population/region to be screened. Such calculations are required by national authorities and organisations responsible for health system budgets to determine the best age cutoffs for screening programs and decide whether programs of screening should be funded. Therefore, we aimed to determine the exact yield and calculated stroke-risk profile of screen-detected AF and NNS-Rx in 5-year age strata. METHODS AND FINDINGS: A systematic review of Medline, Pubmed, and Embase was performed (January 2007 to February 2018), and AF-SCREEN international collaboration members were contacted to identify additional studies. Twenty-four eligible studies were identified that performed a single time point screen for AF in a general ambulant population, including people ≥65 years. Authors from eligible studies were invited to collaborate and share patient-level data. Statistical analysis was performed using random effects logistic regression for AF detection rate, and Poisson regression modelling for CHA2DS2-VASc scores. Nineteen studies (14 countries from a mix of low- to middle- and high-income countries) collaborated, with 141,220 participants screened and 1,539 new AF cases. Pooled yield of screening was greater in males across all age strata. The age/sex-adjusted detection rate for screen-detected AF in ≥65-year-olds was 1.44% (95% CI, 1.13%-1.82%) and 0.41% (95% CI, 0.31%-0.53%) for <65-year-olds. New AF detection rate increased progressively with age from 0.34% (<60 years) to 2.73% (≥85 years). Neither the choice of screening methodology or device, the geographical region, nor the screening setting influenced the detection rate of AF. Mean CHA2DS2-VASc scores (n = 1,369) increased with age from 1.1 (<60 years) to 3.9 (≥85 years); 72% of ≥65 years had ≥1 additional stroke risk factor other than age/sex. All new AF ≥75 years and 66% between 65 and 74 years had a Class-1 OAC recommendation. The NNS-Rx is 83 for ≥65 years, 926 for 60-64 years; and 1,089 for <60 years. The main limitation of this study is there are insufficient data on sociodemographic variables of the populations and possible ascertainment biases to explain the variance in the samples. CONCLUSIONS: People with screen-detected AF are at elevated calculated stroke risk: above age 65, the majority have a Class-1 OAC recommendation for stroke prevention, and >70% have ≥1 additional stroke risk factor other than age/sex. Our data, based on the largest number of screen-detected AF collected to date, show the precise relationship between yield and estimated stroke risk profile with age, and strong dependence for NNS-RX on the age distribution of the population to be screened: essential information for precise cost-effectiveness calculations.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia , Programas de Rastreamento/métodos , Acidente Vascular Cerebral/etiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Fatores Sexuais , Adulto Jovem
14.
Europace ; 21(10): 1603-1604, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31353412

RESUMO

Despite major therapeutic advances over the last decades, complex supraventricular and ventricular arrhythmias (VAs), particularly in the emergency setting or during revascularization for acute myocardial infarction (AMI), remain an important clinical problem. Although the incidence of VAs has declined in the hospital phase of acute coronary syndromes (ACS), mainly due to prompt revascularization and optimal medical therapy, still up to 6% patients with ACS develop ventricular tachycardia and/or ventricular fibrillation within the first hours of ACS symptoms. Despite sustained VAs being perceived predictors of worse in-hospital outcomes, specific associations between the type of VAs, arrhythmia timing, applied treatment strategies and long-term prognosis in AMI are vague. Atrial fibrillation (AF) is the most common supraventricular tachyarrhythmia that may be asymptomatic and/or may be associated with rapid haemodynamic deterioration requiring immediate treatment. It is estimated that over 20% AMI patients may have a history of AF, whereas the new-onset arrhythmia may occur in 5% patients with ST elevation myocardial infarction. Importantly, patients who were treated with primary percutaneous coronary intervention for AMI and developed AF have higher rates of adverse events and mortality compared with subjects free of arrhythmia. The scope of this position document is to cover the clinical implications and pharmacological/non-pharmacological management of arrhythmias in emergency presentations and during revascularization. Current evidence for clinical relevance of specific types of VAs complicating AMI in relation to arrhythmia timing has been discussed.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Terapia de Ressincronização Cardíaca/normas , Cardiologia , Consenso , Intervenção Coronária Percutânea/normas , Sociedades Médicas , Taquicardia Ventricular/terapia , Síndrome Coronariana Aguda/complicações , Europa (Continente) , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Prognóstico , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
15.
Eur J Prev Cardiol ; 26(9): 964-972, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30935219

RESUMO

AIMS: Overall, 40% of patients with atrial fibrillation are asymptomatic. The usefulness and cost-effectiveness of atrial fibrillation screening programmes are debated. We evaluated whether an atrial fibrillation screening programme with a handheld electrocardiogram (ECG) machine in a population-wide cohort has a high screening yield and is cost-effective. METHODS: We used a Markov-model based modelling analysis on 1000 hypothetical individuals who matched the Belgian Heart Rhythm Week screening programme. Subgroup analyses of subjects ≥65 and ≥75 years old were performed. Screening was performed with one-lead ECG handheld machine Omron® HeartScan HCG-801. RESULTS: In both overall population and subgroups, the use of the screening procedure diagnosed a consistently higher number of diagnosed atrial fibrillation than not screening. In the base-case scenario, the screening procedure resulted in 106.6 more atrial fibrillation patient-years, resulting in three fewer strokes, 10 more life years and five more quality-adjusted life years (QALYs). The number needed-to-screen (NNS) to avoid one stroke was 361. In subjects ≥65 years old, we found 80.8 more atrial fibrillation patient-years, resulting in three fewer strokes, four more life-years and five more QALYs. The NNS to avoid one stroke was 354. Similar results were obtained in subjects ≥75 years old, with a NNS to avoid one stroke of 371. In the overall population, the incremental cost-effectiveness ratio for any gained QALY showed that the screening procedure was cost-effective in all groups. CONCLUSIONS: In a population-wide screening cohort, the use of a handheld ECG machine to identify subjects with newly diagnosed atrial fibrillation was cost-effective in the general population, as well as in subjects ≥65 and subjects ≥75 years old.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Eletrocardiografia/economia , Custos de Cuidados de Saúde , Programas de Rastreamento/economia , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/mortalidade , Bélgica/epidemiologia , Análise Custo-Benefício , Eletrocardiografia/instrumentação , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Cadeias de Markov , Programas de Rastreamento/instrumentação , Pessoa de Meia-Idade , Modelos Econômicos , Valor Preditivo dos Testes , Prevalência , Prognóstico , Fatores de Tempo
16.
Europace ; 21(6): 844­845, 2019 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-30882141

RESUMO

Asymptomatic arrhythmias are frequently encountered in clinical practice. Although studies specifically dedicated to these asymptomatic arrhythmias are lacking, many arrhythmias still require proper diagnostic and prognostic evaluation and treatment to avoid severe consequences, such as stroke or systemic emboli, heart failure, or sudden cardiac death. The present document reviews the evidence, where available, and attempts to reach a consensus, where evidence is insufficient or conflicting.

17.
Eur J Prev Cardiol ; 26(7): 764-775, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30813818

RESUMO

BACKGROUND: In the ICD Sports Safety Registry, death, arrhythmia- or shock-related physical injury did not occur in athletes who continue competitive sports after implantable cardioverter-defibrillator (ICD) implantation. However, data from non-competitive ICD recipients is lacking. This report describes arrhythmic events and lead performance in intensive recreational athletes with ICDs enrolled in the European recreational arm of the Registry, and compares their outcome with those of the competitive athletes in the Registry. METHODS: The Registry recruited 317 competitive athletes ≥ 18 years old, receiving an ICD for primary or secondary prevention (234 US; 83 non-US). In Europe, Israel and Australia only, an additional cohort of 80 'auto-competitive' recreational athletes was also included, engaged in intense physical activity on a regular basis (≥2×/week and/or ≥ 2 h/week) with the explicit aim to improve their physical performance limits. Athletes were followed for a median of 44 and 49 months, respectively. ICD shock data and clinical outcomes were adjudicated by three electrophysiologists. RESULTS: Compared with competitive athletes, recreational athletes were older (median 44 vs. 37 years; p = 0.0004), more frequently men (79% vs. 68%; p = 0.06), with less idiopathic ventricular fibrillation or catecholaminergic polymorphic ventricular tachycardia (1.3% vs. 15.4%), less congenital heart disease (1.3% vs. 6.9%) and more arrhythmogenic right ventricular cardiomyopathy (23.8% vs. 13.6%) ( p < 0.001). They more often had a prophylactic ICD implant (51.4% vs. 26.9%; p < 0.0001) or were given a beta-blocker (95% vs. 65%; p < 0.0001). Left ventricular ejection fraction, ICD rate cut-off and time from implant were similar. Recreational athletes performed fewer hours of sports per week (median 4.5 vs. 6 h; p = 0.0004) and fewer participated in sports with burst-performances ( vs. endurance) as their main sports: 4% vs. 65% ( p < 0.0001). None of the athletes in either group died, required external resuscitation or was injured due to arrhythmia or shock. Freedom from definite or probable lead malfunction was similar (5-year 97% vs. 96%; 10-year 93% vs. 91%). Recreational athletes received fewer total shocks (13.8% vs. 26.5%, p = 0.01) due to fewer inappropriate shocks (2.5% vs. 12%; p = 0.01). The proportion receiving appropriate shocks was similar (12.5% vs. 15.5%, p = 0.51). Recreational athletes received fewer total (6.3% vs. 20.2%; p = 0.003), appropriate (3.8% vs. 11.4%; p = 0.06) and inappropriate (2.5% vs. 9.5%; p = 0.04) shocks during physical activity. Ventricular tachycardia/fibrillation storms during physical activity occurred in 0/80 recreational vs. 7/317 competitive athletes. Appropriate shocks during physical activity were related to underlying disease ( p = 0.004) and competitive versus recreational sports ( p = 0.004), but there was no relation with age, gender, type of indication, beta-blocker use or burst/endurance sports. The proportion of athletes who stopped sports due to shocks was similar (3.8% vs. 7.5%, p = 0.32). CONCLUSIONS: Participants in recreational sports had less frequent appropriate and inappropriate shocks during physical activity than participants in competitive sports. Shocks did not cause death or injury. Recreational athletes with ICDs can engage in sports without severe adverse outcomes unless other reasons preclude continuation.


Assuntos
Arritmias Cardíacas/terapia , Atletas , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica , Esforço Físico , Esportes , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Comportamento Competitivo , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Prevenção Primária , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Prevenção Secundária , Resultado do Tratamento , Adulto Jovem
18.
Acta Cardiol ; 74(1): 46-51, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29463193

RESUMO

This report presents and discusses, on behalf of the Belgian College of Cardiology, the evolution of the peer review process in arrhythmology, focussing on pacemaker implantation. Data from the last 22 years are compared. The national annual increase in implants is around 1%, clinical patient characteristics remained stable over the years while dual chamber pacing was proportionally increasing. Analyses of the normalised sick sinus and complete atrioventricular block ratios revealed a quite homogenous practice between centres and patient district with the only exception of the two more crowded districts. Battery longevity and infection rate were also assessed. With an incidence of 1/1000 device-years follow-up, Belgium remains below accepted European levels.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/normas , Cardiologia , Marca-Passo Artificial/estatística & dados numéricos , Revisão por Pares/métodos , Garantia da Qualidade dos Cuidados de Saúde , Sociedades Médicas , Idoso , Bélgica , Bases de Dados Factuais , Feminino , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA