Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Interv Neuroradiol ; 28(2): 201-212, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34078155

RESUMO

BACKGROUND: The Silk Vista Baby (SVB) flow diverter (FDS) is the only FDS deliverable via a 0.017 inch microcatheter and is specifically designed for the distal vasculature. We sought to evaluate the safety and efficacy of the SVB. MATERIALS AND METHODS: We performed a retrospective review to identify SVB cases at 4 tertiary neurosurgical centres within the U.K. Clinical, procedural, angiographic and follow-up data were collected. RESULTS: We identified 60 patients (35 female, 58%) of average age 54 ± 10.5 (range 30-72) with 61 aneurysms, 50 (81.9%) located in the anterior circulation. The majority of the aneurysms treated were unruptured (46, 75.4%) and saccular (46, 75.4%). Dome size was 6.2 ± 6.2 mm (range 1-36mm) and parent vessel diameter was 2.3 ± 0.4 mm (range 1.2-3.3 mm).An average number of 1.07 devices were implanted. Coils or other devices were implanted in 14 aneurysms (23.3%). At last angiographic follow-up (n = 55), 7.5 ± 4.2 months post-procedure, 32 aneurysms (57.1%) were graded as RRC I, 7 (12.5%) RRC II, and 17 RRC III (30.4%).Clinical complications, excluding death, were seen in 4 patients (6.8%) including 1 delayed aneurysm rupture and 3 symptomatic ischaemic events. Only one patient had permanent morbidity (mRS 1). 3 patients died during follow-up (5.1%); 2 deaths were related to the aneurysms (3.4%) - one ruptured dissecting MCA aneurysm, and one giant partially thrombosed posterior circulation aneurysm. 93% of patients were mRS ≤ 2 at last follow-up. CONCLUSION: The SVB has high rates of technical success and an acceptable safety profile. Distal aneurysms may occlude slower due to relative oversizing of the devices.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Adulto , Procedimentos Endovasculares/métodos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/etiologia , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Seda , Stents/efeitos adversos , Resultado do Tratamento , Reino Unido
2.
Interv Neuroradiol ; 26(4): 494-500, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32393085

RESUMO

BACKGROUND: Balloon and stent-assisted coiling of aneurysms have increased the number of aneurysms available for endovascular treatment. Newer devices that allow flow within the parent vessel but coverage at the neck have recently entered the market. The Cascade is a new non-occlusive fully retrievable neck-bridging support device that has been designed to provide temporary support during coil embolisation of intracranial aneurysms. METHODS: Using a silicone aneurysm model three different aneurysms were catheterised with the coiling microcatheter placed in three different positions within each aneurysm - at the neck, centrally, and looped within the aneurysm. Multiple different coils were then deployed within each aneurysm with the Cascade device deployed across the neck to provide protection. In total 480 attempted coilings were performed. Aneurysm flow was used to calculate the change in intra-aneurysmal flow with the Cascade device deployed across the neck of the aneurysm. RESULTS: We did not observe a single episode of coil protrusion through the Cascade mesh nor did we observe any coil protrusion into the parent vessel when the Cascade was deployed across the neck. There was an average flow velocity reduction of 23% with the Cascade device deployed across the neck of the aneurysm. CONCLUSION: The Cascade device offers robust protection of the aneurysmal neck and parent vessel as well as inducing significant intra-aneurysmal flow velocity reduction.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Stents , Desenho de Equipamento , Humanos , Técnicas In Vitro
3.
Interv Neuroradiol ; 26(6): 779-784, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32443960

RESUMO

We present a patient with a ruptured basilar tip aneurysm treated under conscious sedation via a right radial approach using the Woven EndoBridge device. We discuss the technical aspects of the case as the well as the available literature on the treatment of ruptured aneurysms treated without general anaesthesia. We discuss the potential benefits of the Woven EndoBridge device in such situations.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Sedação Consciente , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Resultado do Tratamento
4.
Interv Neuroradiol ; 26(1): 68-73, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31451027

RESUMO

We present the first case using a novel flow diverter, the Silk Vista Baby (Balt, Montmorency, France), in combination with a low-profile braided stent, the Baby Leo (Balt, Montmorency, France), in a T configuration that we term Flow-T. We describe the technical characteristics of the case as well as the early follow-up results. We believe that this combination may provide an alternative to standard T-stenting and alternative to treat bifurcation aneurysms.


Assuntos
Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Procedimentos Neurocirúrgicos/métodos , Stents , Adulto , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Seda , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA