1.
J Biomech ; 173: 112236, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39084063

RESUMO

Normal biomechanics of the upper cervical spine, particularly at the atlantooccipital joint, remain poorly characterized. The purpose of this study was to determine the intervertebral kinematics of the atlantooccipital joint (occiput-C1) during three-dimensional in vivo physiologic movements. Twenty healthy young adults performed dynamic flexion/extension, axial rotation, and lateral bending while biplane radiographs were collected at 30 images per second. Motion at occiput-C1 was tracked using a validated volumetric model-based tracking process that matched subject-specific CT-based bone models to the radiographs. The occiput-C1 total range of motion (ROM) and helical axis of motion (HAM) was calculated for each movement. During flexion/extension, the occiput-C1 moved almost exclusively in-plane (ROM: 17.9 ± 6.9°) with high variability in kinematic waveforms (6.3°) compared to the in-plane variability during axial rotation (1.4°) and lateral bending (0.9°) movements. During axial rotation, there was small in-plane motion (ROM: 4.2 ± 2.5°) compared to out-of-plane flexion/extension (ROM: 12.7 ± 5.4°). During lateral bending, motion occurred in-plane (ROM: 9.0 ± 3.1°) and in the plane of flexion/extension (ROM: 7.3 ± 2.7°). The average occiput-C1 axis of rotation intersected the sagittal and coronal planes 7 mm to 18 mm superior to the occipital condyles. The occiput-C1 axis of rotation pointed 60° from the sagittal plane during axial rotation but only 10° from the sagittal plane during head lateral bending. These novel results are foundational for future work on upper cervical spine kinematics.


Assuntos
Articulação Atlantoccipital , Amplitude de Movimento Articular , Humanos , Amplitude de Movimento Articular/fisiologia , Masculino , Articulação Atlantoccipital/fisiologia , Articulação Atlantoccipital/diagnóstico por imagem , Fenômenos Biomecânicos , Feminino , Adulto , Movimento/fisiologia , Rotação , Adulto Jovem , Imageamento Tridimensional , Vértebras Cervicais/fisiologia , Vértebras Cervicais/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
Spine (Phila Pa 1976) ; 48(22): 1561-1567, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37339257

RESUMO

STUDY DESIGN: Prospective Cohort. OBJECTIVE: Quantify and compare the effectiveness of cervical orthoses in restricting intervertebral kinematics during multiplanar motions. SUMMARY OF BACKGROUND DATA: Previous studies evaluating the efficacy of cervical orthoses measured global head motion and did not evaluate individual cervical motion segment mobility. Prior studies focused only on the flexion/extension motion. METHODS: Twenty adults without neck pain participated. Vertebral motion from the occiput through T1 was imaged using dynamic biplane radiography. Intervertebral motion was measured using an automated registration process with validated accuracy better than 1 degree. Participants performed independent trials of maximal flexion/extension, axial rotation, and lateral bending in a randomized order of unbraced, soft collar (foam), hard collar (Aspen), and cervical thoracic orthosis (CTO) (Aspen) conditions. Repeated-measures ANOVA was used to identify differences in the range of motion (ROM) among brace conditions for each motion. RESULTS: Compared with no collar, the soft collar reduced flexion/extension ROM from occiput/C1 through C4/C5, and reduced axial rotation ROM at C1/C2 and from C3/C4 through C5/C6. The soft collar did not reduce motion at any motion segment during lateral bending. Compared with the soft collar, the hard collar reduced intervertebral motion at every motion segment during all motions, except for occiput/C1 during axial rotation and C1/C2 during lateral bending. The CTO reduced motion compared with the hard collar only at C6/C7 during flexion/extension and lateral bending. CONCLUSIONS: The soft collar was ineffective as a restraint to intervertebral motion during lateral bending, but it did reduce intervertebral motion during flexion/extension and axial rotation. The hard collar reduced intervertebral motion compared with the soft collar across all motion directions. The CTO provided a minimal reduction in intervertebral motion compared with the hard collar. The utility in using a CTO rather than a hard collar is questionable, given the cost and little or no additional motion restriction.


Assuntos
Vértebras Cervicais , Aparelhos Ortopédicos , Adulto , Humanos , Estudos Prospectivos , Vértebras Cervicais/diagnóstico por imagem , Rotação , Fenômenos Biomecânicos , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA