Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 63: 1-7, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38423848

RESUMO

PURPOSE: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS). METHODS: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up. RESULTS: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %). CONCLUSIONS: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Idoso , Índia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Fatores de Risco , Recuperação de Função Fisiológica , Complicações Pós-Operatórias , Estudos Retrospectivos , Hemodinâmica
3.
Heart Asia ; 6(1): 159-62, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27326196

RESUMO

BACKGROUND: Resistance to antiplatelet drugs is a well-known entity. However, data for aspirin and clopidogrel resistance, and its clinical significance, in Indian patients are meagre. AIMS AND OBJECTIVES: We sought to determine the prevalence of resistance to aspirin and clopidogrel in Indian patients with stable coronary heart disease (CHD), using the cone and plate(let) analyser (CPA) technology. SETTING AND DESIGN: A single centre prospective study in a cohort of patients with stable CHD on chronic aspirin and clopidogrel therapy attending the cardiology outpatient clinic of a tertiary care hospital in Southern India. METHODS: Platelet function was measured using the Impact-R device (DiaMed, Cressier, Switzerland). Resistance to aspirin and clopidogrel was measured in a cohort of 100 patients with stable documented CHD. Relation of antiplatelet resistance to various clinical comorbidities was also assessed. RESULTS: Of the 100 patients, 85% were men, and 15% were above 65 years of age. 47% patients had diabetes, 29% of patients were hypertensive and 16% were smokers. Using the CPA, 12 patients (12%) were found to be resistant to aspirin and 19 patients (19%) were clopidogrel resistant. In addition, 10 patients (10%) were resistant to both aspirin and clopidogrel. There was no significant correlation between the presence of antiplatelet resistance and several baseline clinical variables, including age, sex, diabetes, hypertension and smoking. CONCLUSIONS: Resistance to aspirin and clopidogrel and dual antiplatelet resistance are prevalent in Indian patients, comparable with the prevalence worldwide. The CPA is a feasible assay to determine antiplatelet resistance.

4.
Catheter Cardiovasc Interv ; 57(3): 353-62, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12410514

RESUMO

Ten patients who had anatomic alterations that cause impediments to successful completion of conventional transfemoral balloon mitral valvuloplasty (BMV) underwent transjugular BMV. They included six patients in whom conventional BMV could not be completed due to cardiac anatomic distortion; two patients with dextrocardia (one with visceroatrial situs solitus and the other with situs inversus); two patients with venous abnormalities (one with azygous continuation of the inferior vena cava and the other with bilateral iliac/femoral vein occlusion). Transjugular BMV was successful in all 10 patients (mean mitral valve area increasing from 0.68 +/- 0.17 to 1.92 +/- 0.40 cm(2); range, 1.56-2.76 cm(2)); it was quick (mean total fluoroscopy time, 10.5 +/- 2.7 min; range, 7.3-15.2 min); and it was safe (no major or minor complications except one patient who developed severe mitral regurgitation that only required medical therapy). The jugular approach to BMV overcomes many of the technical problems caused by anatomic changes that are encountered in transfemoral BMV and complements the latter approach.


Assuntos
Cateterismo , Veias Jugulares/patologia , Veias Jugulares/cirurgia , Estenose da Valva Mitral/terapia , Valva Mitral/patologia , Valva Mitral/cirurgia , Cardiopatia Reumática/terapia , Adolescente , Adulto , Cateterismo/métodos , Dextrocardia/complicações , Dextrocardia/terapia , Feminino , Veia Femoral/patologia , Veia Femoral/cirurgia , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Septos Cardíacos/patologia , Septos Cardíacos/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/complicações , Complicações Pós-Operatórias/etiologia , Cardiopatia Reumática/complicações , Resultado do Tratamento , Veia Cava Inferior/patologia , Veia Cava Inferior/cirurgia , Veia Cava Superior/patologia , Veia Cava Superior/cirurgia
5.
Catheter Cardiovasc Interv ; 55(2): 245-9, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11835658

RESUMO

A 21-year-old female developed severe unremitting intravascular hemolysis following closure of a large patent ductus arteriosus using an Amplatzer duct occluder. Percutaneous deployment of fibered platinum coils within the nitinol wire cage of the Amplatzer duct occluder abolished the residual shunt through the device and resulted in cessation of intravascular hemolysis and reversal of its adverse sequelae.


Assuntos
Cateteres de Demora/efeitos adversos , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/cirurgia , Hemólise , Adulto , Falha de Equipamento , Feminino , Humanos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA