Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Sci Total Environ ; 933: 173164, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38735317

RESUMO

The emergence of the SARS-CoV-2 variant BA.2.86.1 raised a considerable concern, due to the large number of potentially virulent mutations. In this study, we developed a novel assay that specifically detects variant BA.2.86.1, and used it to screen environmental samples from wastewater treatment sites across Israel. By using a multiplex assay that included a general SARS-CoV-2 reaction, together with the BA.2.86.1-specific reaction and a control reaction, we quantified the absolute number of viral copies in each sample and its relative abundance, compared with the total copy number of circulating SARS-CoV-2. Evaluation of the new reactions showed that they are both sensitive and specific, detecting down to four copies per reaction, and maintain specificity in the presence of Omicron variants BA.1, 2 and 4 RNA. Examination of 279 samples from 30 wastewater collection sites during August-September 2023 showed that 35 samples (12.5 %) were positive, from 18 sites. Quantitative analysis of the samples showed that the relative abundance of variant BA.2.86.1 with respect to the total viral load of SARS-CoV-2 was very low and consisted between 0.01 % and 0.6 % of the total SARS-CoV-2 circulation. This study demonstrates the importance of combining wastewater surveillance with the development of specialized diagnostic assays, when clinical testing is insufficient. This approach may be useful for timely response by public health authorities in future outbreaks.


Assuntos
COVID-19 , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2 , Águas Residuárias , Águas Residuárias/virologia , Israel , SARS-CoV-2/genética , COVID-19/epidemiologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Humanos , Monitoramento Ambiental/métodos
2.
Microbiol Spectr ; 11(3): e0022523, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37140382

RESUMO

In this report, we describe the first national scale multi-laboratory evaluation of monkeypox virus (MPXV) DNA commercial PCR kits. The objective of this study was to evaluate 2 kits by different diagnostic laboratories across Israel. Ten standardized samples were tested simultaneously using the Novaplex (15 laboratories) and Bio-Speedy (seven laboratories) kits. An in-house assay based on previously published reactions was used as reference. Comparison of the results showed high intra-assay agreement between laboratories, with small variations for most samples. The in-house assay had an analytical detection limit of less than 10 copies per reaction. While the 2 commercial kits were able to detect specimens with low viral loads similarly to the in-house assay, significant differences were observed, in the Cq values and relative fluorescence (RF), between the assays. The RF signal of the in-house and Bio-Speedy assays ranged between 5,000 and 10,000 RFU, while the signal in the Novaplex assay was less than 600 RFU. Due to the kit measurement protocol, the Cq values of the Bio-Speedy kit were 5 to 7.5 cycles lower than those of the in-house assay. On the contrary, the Cq values of the Novaplex kit were significantly higher than those of the in-house assay, with differences of 3 to 5 cycles per sample. Our results suggest that while all assays were similar in their overall sensitivity, direct comparison of Cq values between them may be misleading. To our knowledge, this is the first methodical evaluation of commercial MPX test kits. We therefore anticipate that this study would help diagnostic laboratories in choosing a specific MPX detection assay. IMPORTANCE To the best of our knowledge, this study is the first methodical evaluation of commercial kits designed for Monkeypox virus detection. This was done by performing the same tests using the same sample set in multiple laboratories, simultaneously, on a national scale. It therefore provides important and unique information on the performance of such kits and provides a guideline for choosing the assay of choice for monkeypox virus diagnosis in a standard diagnostic laboratory. It also demonstrates potential complications when trying to compare the results of different assays, even when testing exactly the same samples, under identical conditions.


Assuntos
Laboratórios , Monkeypox virus , Monkeypox virus/genética , Sensibilidade e Especificidade , Reação em Cadeia da Polimerase , Carga Viral/métodos
3.
Viruses ; 14(6)2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35746700

RESUMO

In this report, we describe a national-scale monitoring of the SARS-CoV-2 (SC-2) variant dynamics in Israel, using multiple-time sampling of 13 wastewater treatment plants. We used a combination of inclusive and selective quantitative PCR assays that specifically identify variants A19/A20 or B.1.1.7 and tested each sample for the presence and relative viral RNA load of each variant. We show that between December 2020 and March 2021, a complete shift in the SC-2 variant circulation was observed, where the B.1.1.7 replaced the A19 in all examined test points. We further show that the normalized viral load (NVL) values and the average new cases per week reached a peak in January 2021 and then decreased gradually in almost all test points, in parallel with the progression of the national vaccination campaign, during February-March 2021. This study demonstrates the importance of monitoring SC-2 variant by using a combination of inclusive and selective PCR tests on a national scale through wastewater sampling, which is far more amendable for high-throughput monitoring compared with sequencing. This approach may be useful for real-time dynamics surveillance of current and future variants, such as the Omicron (BA.1, BA.2) and other variants.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/epidemiologia , Humanos , Israel/epidemiologia , SARS-CoV-2/genética , Águas Residuárias
4.
Microbiol Spectr ; 10(2): e0217621, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35285705

RESUMO

In this report, we describe the development of a reverse transcription-quantitative PCR (RT-qPCR) assay, termed Alpha-Delta assay, which can detect all severe acute respiratory syndrome coronavirus 2 (SC-2) variants and distinguish between the Alpha (B.1.1.7) and Delta (B.1.617.2) variants. The Alpha- and Delta-specific reactions in the assay target mutations that are strongly linked to the target variant. The Alpha reaction targets the D3L substitution in the N gene, and the Delta reaction targets the spike gene 156 to 158 mutations. Additionally, we describe a second Delta-specific assay that we use as a confirmatory test for the Alpha-Delta assay that targets the 119 to 120 deletion in the Orf8 gene. Both reactions have similar sensitivities of 15 to 25 copies per reaction, similar to the sensitivity of commercial SC-2 detection tests. The Alpha-Delta assay and the Orf8119del assay were successfully used to classify clinical samples that were subsequently analyzed by whole-genome sequencing. Lastly, the capability of the Alpha-Delta assay and Orf8119del assay to identify correctly the presence of Delta RNA in wastewater samples was demonstrated. This study provides a rapid, sensitive, and cost-effective tool for detecting and classifying two worldwide dominant SC-2 variants. It also highlights the importance of a timely diagnostic response to the emergence of new SC-2 variants with significant consequences on global health. IMPORTANCE The new assays described herein enable rapid, straightforward, and cost-effective detection of severe acute respiratory syndrome coronavirus 2 (SC-2) with immediate classification of the examined sample as Alpha, Delta, non-Alpha, or non-Delta variant. This is highly important for two main reasons: (i) it provides the scientific and medical community with a novel diagnostic tool to rapidly detect and classify any SC-2 sample of interest as Alpha, Delta, or none and can be applied to both clinical and environmental samples, and (ii) it demonstrates how to respond to the emergence of new variants of concern by developing a variant-specific assay. Such assays should improve our preparedness and adjust the diagnostic capacity to serve clinical, epidemiological, and research needs.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2/genética , Sequenciamento Completo do Genoma
5.
Microbiol Spectr ; 9(2): e0050621, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-34612692

RESUMO

Emerging SARS-CoV-2 (SC-2) variants with increased infectivity and vaccine resistance are of major concern. Rapid identification of such variants is important for the public health decision making and to provide valuable data for epidemiological and policy decision making. We developed a multiplex reverse transcriptase quantitative PCR (RT-qPCR) assay that can specifically identify and differentiate between the emerging B.1.1.7 and B.1.351 SC-2 variants. In a single assay, we combined four reactions-one that detects SC-2 RNA independently of the strain, one that detects the D3L mutation, which is specific to variant B.1.1.7, one that detects the 242 to 244 deletion, which is specific to variant B.1.351, and the fourth reaction, which identifies the human RNAseP gene, serving as an endogenous control for RNA extraction integrity. We show that the strain-specific reactions target mutations that are strongly associated with the target variants and not with other major known variants. The assay's specificity was tested against a panel of respiratory pathogens (n = 16), showing high specificity toward SC-2 RNA. The assay's sensitivity was assessed using both in vitro transcribed RNA and clinical samples and was determined to be between 20 and 40 viral RNA copies per reaction. The assay performance was corroborated with Sanger and whole-genome sequencing, showing complete agreement with the sequencing results. The new assay is currently implemented in the routine diagnostic work at the Central Virology Laboratory, and may be used in other laboratories to facilitate the diagnosis of these major worldwide-circulating SC-2 variants. IMPORTANCE This study describes the design and utilization of a multiplex reverse transcriptase quantitative PCR (RT-qPCR) to identify SARS-COV-2 (SC2) RNA in general and, specifically, to detect whether it is of lineage B.1.1.7 or B.1.351. Implementation of this method in diagnostic and research laboratories worldwide may help the efforts to contain the COVID-19 pandemic. The method can be easily scaled up and be used in high-throughput laboratories, as well as small ones. In addition to immediate help in diagnostic efforts, this method may also help in epidemiological studies focused on the spread of emerging SC-2 lineages.


Assuntos
COVID-19/diagnóstico , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Ensaios de Triagem em Larga Escala/métodos , SARS-CoV-2/classificação , SARS-CoV-2/genética , COVID-19/epidemiologia , COVID-19/virologia , Genoma Viral/genética , Humanos , Israel/epidemiologia , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Sequenciamento Completo do Genoma
6.
Chemosphere ; 283: 131194, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34467943

RESUMO

The COVID-19 pandemic created a global crisis impacting not only healthcare systems, but also economics and society. Therefore, it is important to find novel methods for monitoring disease activity. Recent data have indicated that fecal shedding of SARS-CoV-2 is common, and that viral RNA can be detected in wastewater. This suggests that wastewater monitoring is a potentially efficient tool for both epidemiological surveillance, and early warning for SARS-CoV-2 circulation at the population level. In this study we sampled an urban wastewater infrastructure in the city of Ashkelon (Ì´ 150,000 population), Israel, during the end of the first COVID-19 wave in May 2020 when the number of infections seemed to be waning. We were able to show varying presence of SARS-CoV-2 RNA in wastewater from several locations in the city during two sampling periods, before the resurgence was clinically apparent. This was expressed with a new index, Normalized Viral Load (NVL) which can be used in different area scales to define levels of virus activity such as red (high) or green (no), and to follow morbidity in the population at the tested area. The rise in viral load between the two sampling periods (one week apart) indicated an increase in morbidity that was evident two weeks to a month later in the population. Thus, this methodology may provide an early indication for SARS-CoV-2 infection outbreak in a population before an outbreak is clinically apparent.


Assuntos
COVID-19 , Esgotos , Humanos , Pandemias , RNA Viral , SARS-CoV-2 , Águas Residuárias
7.
Front Public Health ; 9: 561710, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047467

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an RNA virus, a member of the coronavirus family of respiratory viruses that includes severe acute respiratory syndrome coronavirus 1 (SARS-CoV-1) and the Middle East respiratory syndrome (MERS). It has had an acute and dramatic impact on health care systems, economies, and societies of affected countries during the past 8 months. Widespread testing and tracing efforts are being employed in many countries in attempts to contain and mitigate this pandemic. Recent data has indicated that fecal shedding of SARS-CoV-2 is common and that the virus RNA can be detected in wastewater. This indicates that wastewater monitoring may provide a potentially efficient tool for the epidemiological surveillance of SARS-CoV-2 infection in large populations at relevant scales. In particular, this provides important means of (i) estimating the extent of outbreaks and their spatial distributions, based primarily on in-sewer measurements, (ii) managing the early-warning system quantitatively and efficiently, and (iii) verifying disease elimination. Here we report different virus concentration methods using polyethylene glycol (PEG), alum, or filtration techniques as well as different RNA extraction methodologies, providing important insights regarding the detection of SARS-CoV-2 RNA in sewage. Virus RNA particles were detected in wastewater in several geographic locations in Israel. In addition, a correlation of virus RNA concentration to morbidity was detected in Bnei-Barak city during April 2020. This study presents a proof of concept for the use of direct raw sewage-associated virus data, during the pandemic in the country as a potential epidemiological tool.


Assuntos
COVID-19 , Esgotos , Monitoramento Ambiental , Humanos , RNA Viral/genética , SARS-CoV-2
8.
PLoS One ; 14(2): e0211079, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30779757

RESUMO

Respiratory viral infections constitute the majority of samples tested in the clinical virology laboratory during the winter season, and are mainly diagnosed using molecular assays, namely real-time PCR (qPCR). Therefore, a high-quality extraction process is critical for successful, reliable and sensitive qPCR results. Here we aimed to evaluate the performance of the newly launched eMAG compared to the fully automated MagNA PURE 96 (Roche, Germany) and to the semi-automated easyMAG (bioMerieux, France) extraction platforms. For this analysis, we assessed and compared the analytic and clinical performance of the three platforms, using 262 archived respiratory samples positive or negative to common viruses regularly examined in our laboratory (influenza A, B, H1N1pdm, Respiratory Syncytial Virus (RSV), human Metapneumovirus (hMPV), parainfluenza-3, adenovirus and negative samples). In addition, quantitated virus controls were used to determine the limit of detection of each extraction method. In all categories tested, eMAG results were comparable to those of the easyMAG and MagNa PURE 96, highly sensitive for all viruses and over 98% clinical specificity and sensitivity for all viruses tested. Together with its high level of automation, the bioMerieux eMAG is a high-quality extraction platform enabling effective molecular analysis and is mostly suitable for medium-sized laboratories.


Assuntos
Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/virologia , Automação , DNA Viral/análise , DNA Viral/genética , Humanos , Israel , Laboratórios , Limite de Detecção , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/instrumentação
9.
Isr Med Assoc J ; 20(5): 295-299, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29761675

RESUMO

BACKGROUND: Shortened telomeres were found in patients with cirrhosis, probably reflecting chronic liver injury, continuous regeneration, and destruction of hepatic nodules. OBJECTIVES: To test whether telomere shortening is a general marker of cirrhosis, independent of disease etiology. METHODS: We evaluated telomere length in patients with cryptogenic cirrhosis (largely a late sequela of steatohepatitis) compared to patients with cirrhosis caused by chronic hepatitis B and C (HBV/HCV). We also evaluated telomere aggregates, a sensitive parameter of telomere dysfunction and genetic instability. We analyzed peripheral lymphocytes from 25 patients with cryptogenic cirrhosis, 15 patients with cirrhosis due to chronic viral hepatitis, and 20 age-matched controls. Telomere length was analyzed using quantitative fluorescence in situ hybridization. Aggregate size was divided into three fusion groups of 2-5, 6-10, and 11-15 telomeres, relative to the size of a single telomere. RESULTS: Shorter telomere length was found in patients with cirrhosis from all three etiologies (mean 121.3 ± 24.1) compared to controls (mean 63.5 ± 23.5). In contrast, there was significantly more fusion of > 5 telomeres only in the HBV/HCV cirrhosis group compared to healthy controls (P = 0.023), but not in the cryptogenic cirrhosis group. CONCLUSIONS: While shortened telomeres in peripheral lymphocytes are a general marker of liver cirrhosis, telomere aggregates may signify a more sensitive genetic instability parameter for the diverse, etiology-based malignant potential of cirrhosis. This finding is in agreement with the well-known higher tendency toward developing hepatocellular carcinoma with cirrhosis caused by chronic hepatitis relative to steatohepatitis.


Assuntos
Cirrose Hepática/diagnóstico , Cirrose Hepática/patologia , Telômero/patologia , Feminino , Humanos , Hibridização in Situ Fluorescente , Israel , Fígado/metabolismo , Fígado/patologia , Cirrose Hepática/metabolismo , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Telômero/metabolismo
10.
Emerg Infect Dis ; 23(10): 1699-1702, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28930008

RESUMO

We identified Usutu virus (USUV) RNA in 6 pools of mosquitoes trapped in northern Israel during 2014-2015. These Israeli strains were most similar to strains identified in Senegal and Germany, which further elucidates common ancestry and evolutionary dynamics of USUV. Our findings suggest that human infection with USUV might occur in Israel.


Assuntos
Culex/virologia , Flavivirus/genética , Insetos Vetores/virologia , RNA Viral/genética , Proteínas não Estruturais Virais/genética , Animais , Flavivirus/classificação , Flavivirus/isolamento & purificação , Infecções por Flavivirus/epidemiologia , Infecções por Flavivirus/transmissão , Alemanha/epidemiologia , Humanos , Israel/epidemiologia , Filogenia , Filogeografia , Senegal/epidemiologia
11.
PLoS One ; 12(6): e0179774, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28622360

RESUMO

West Nile Virus (WNV) is endemic in Israel, affecting yearly 40-160 individuals. Israel is located on a central migratory path between Africa and Eurasia and most West Nile Fever (WNF) cases reported in recent years were among residents of the coastal plain. The aim of the study was to evaluate the seroprevalence of WNV among the Israeli population and to assess correlates for WNV infection. A cross-sectional nationwide serologic survey was conducted using 3,145 serum samples collected by the national Israeli serum bank during 2011-2014, representing all age and population groups in Israel. Prevalence rates of WNV IgG antibodies were determined. Logistic regressions models were applied to assess the associations between demographic characteristics and WNV seropositivity. 350 samples were positive to WNV (11.1%; 95%CI: 10.0-12.3%). In the multivariable analysis, there was a significant association between seropositivity and the Arab population group vs. Jews and others (OR = 1.86, 95%CI: 1.37-2.52), the time lived in Israel [50-59 years vs. 0-9 years; OR = 10.80 (95%CI: 1.03-113.46) and ≥60 years vs. 0-9 years; OR = 14.00 (1.32-148.31)] residence area] Coastal Plain, Inland Plain (Shfela) and Great Rift Valley vs. Upper Galilee; OR = 2.24 (95%CI: 1.37-3.65), OR = 2.18 (95%CI: 1.18-4.03), OR = 1.90 (95%CI: 1.10-3.30), respectively [and rural vs. urban settlement (OR = 1.65, 95%CI: 1.26-2.16). People, who reside in the Coastal Plain, Inland Plain and Great Rift Valley, should be aware of the risk of contracting WNV and reduce exposure to mosquito bites, using insect repellents, and wearing protective clothing. The Ministry of Environmental Protection should be active in reducing the mosquito population by eliminating sources of standing water, a breeding ground for mosquitoes.


Assuntos
Modelos Biológicos , Febre do Nilo Ocidental/epidemiologia , Febre do Nilo Ocidental/transmissão , Vírus do Nilo Ocidental , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Recém-Nascido , Israel , Masculino , Pessoa de Meia-Idade , Estudos Soroepidemiológicos , Febre do Nilo Ocidental/sangue
12.
J Clin Microbiol ; 54(9): 2294-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27335150

RESUMO

The current diagnosis of West Nile virus (WNV) infection is primarily based on serology, since molecular identification of WNV RNA is unreliable due to the short viremia and absence of detectable virus in cerebrospinal fluid (CSF). Recent studies have shown that WNV RNA can be detected in urine for a longer period and at higher concentrations than in plasma. In this study, we examined the presence of WNV RNA in serum, plasma, whole-blood, CSF, and urine samples obtained from patients diagnosed with acute WNV infection during an outbreak which occurred in Israel in 2015. Our results demonstrate that 33 of 38 WNV patients had detectable WNV RNA in whole blood at the time of diagnosis, a higher rate than in any of the other sample types tested. Overall, whole blood was superior to all other samples, with 86.8% sensitivity, 100% specificity, 100% positive predictive value, and 83.9% negative predictive value. Interestingly, WNV viral load in urine was higher than in whole blood, CSF, serum, and plasma despite the lower sensitivity than that of whole blood. This study establishes the utility of whole blood in the routine diagnosis of acute WNV infection and suggests that it may provide the highest sensitivity for WNV RNA detection in suspected cases.


Assuntos
Sangue/virologia , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/isolamento & purificação , Manejo de Espécimes/métodos , Febre do Nilo Ocidental/diagnóstico , Vírus do Nilo Ocidental/isolamento & purificação , Líquido Cefalorraquidiano/virologia , Humanos , Israel , Valor Preditivo dos Testes , RNA Viral/genética , Sensibilidade e Especificidade , Urina/virologia , Vírus do Nilo Ocidental/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA