Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
J Am Heart Assoc ; 13(5): e030975, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390813

RESUMO

BACKGROUND: The effects of pharmacological therapy on cardiogenic shock (CS) survivors have not been extensively studied. Thus, this study investigated the association between guideline-directed heart failure (HF) medical therapy (GDMT) and one-year survival rate in patients who are post-CS. METHODS AND RESULTS: FRENSHOCK (French Observatory on the Management of Cardiogenic Shock in 2016) registry was a prospective multicenter observational survey, conducted in metropolitan French intensive care units and intensive cardiac care units. Of 772 patients, 535 patients were enrolled in the present analysis following the exclusion of 217 in-hospital deaths and 20 patients with missing medical records. Patients with triple GDMT (beta-blockers, renin-angiotensin system inhibitors, and mineralocorticoid receptor antagonists) at discharge (n=112) were likely to have lower left ventricular ejection fraction on admission and at discharge compared with those without triple GDMT (n=423) (22% versus 28%, P<0.001 and 29% versus 37%, P<0.001, respectively). In the overall cohort, the one-year mortality rate was 23%. Triple GDMT prescription was significantly associated with a lower one-year all-cause mortality compared with non-triple GDMT (adjusted hazard ratio 0.44 [95% CI, 0.19-0.80]; P=0.007). Similarly, 2:1 propensity score matching and inverse probability treatment weighting based on the propensity score demonstrated a lower incidence of one-year mortality in the triple GDMT group. As the number of HF drugs increased, a stepwise decrease in mortality was observed (log rank; P<0.001). CONCLUSIONS: In survivors of CS, the one-year mortality rate was significantly lower in those with triple GDMT. Therefore, this study suggests that intensive HF therapy should be considered in patients following CS.


Assuntos
Insuficiência Cardíaca , Choque Cardiogênico , Humanos , Antagonistas Adrenérgicos beta/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Estudos Prospectivos , Sistema de Registros , Volume Sistólico , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto
2.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38234123

RESUMO

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Humanos , Estudos de Coortes , Volume Sistólico , Estudos Prospectivos , Bancos de Espécimes Biológicos , Função Ventricular Esquerda , Algoritmos
3.
Arch Cardiovasc Dis ; 117(2): 160-166, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38092576

RESUMO

Heart failure is a chronic condition that affects millions of people worldwide and is associated with high morbidity and mortality. Remote monitoring, which includes the use of non-invasive connected devices, cardiac implantable electronic devices and haemodynamic monitoring systems, has the potential to improve outcomes for patients with heart failure. Despite the conceptual and clinical advantages, there are still limitations in the widespread use of these technologies. Moreover, a significant proportion of studies evaluating the benefit of remote monitoring in heart failure have focused on the limited area of prevention of rehospitalization after an episode of acute heart failure. A group of experts in the fields of heart failure and digital health worked on this topic in order to provide a practical paper for the use of remote monitoring in clinical practice at the different stages of the heart failure syndrome: (1) discovery of heart failure; (2) acute decompensation of chronic heart failure; (3) heart failure in stable period; and (4) advanced heart failure. A careful and critical analysis of the available literature was performed with the aim of providing caregivers with some recommendations on when and how to use remote monitoring in these different situations, specifying which variables are essential, optional or useless.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Monitorização Fisiológica , Doença Crônica , Arritmias Cardíacas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
4.
JACC Clin Electrophysiol ; 9(12): 2550-2557, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37804261

RESUMO

BACKGROUND: In a preliminary study in patients hospitalized for catheter ablation of atrial fibrillation (AF), the atrial thrombus exclusion (ATE) score (stroke, hypertension, heart failure, and D-dimers >270 ng/mL) was developed to rule out the diagnosis of intra-atrial thrombus, with a negative predictive value (NPV) of 100%, and to avoid performing transesophageal echocardiography (TEE). OBJECTIVES: The present study was designed to prospectively confirm the NPV of the ATE score in an independent population. METHODS: Consecutive patients hospitalized for catheter ablation of AF or left atrial tachycardia (LAT) were prospectively enrolled in a multicenter study. D-dimer levels were measured within 48 hours before ablation. An ATE score of 0 was considered predictive of no thrombus. TEE was routinely performed at the beginning or just before the ablation procedure. The primary endpoint was the presence of atrial thrombus diagnosed by TEE. RESULTS: The analysis included 3,072 patients (53.3% paroxysmal AF, 36.7% persistent AF, and 10% LAT). A thrombus was detected in 29 patients (0.94%; 95% CI: 0.63%-1.35%), all on appropriate anticoagulant therapy. An ATE score of 0 was observed in 818 patients (26.6%), and the sensitivity, specificity, positive predictive value, and NPV were 93.1%, 26.8%, 1.2%, and 99.8%, respectively. Follow-up of the 2 false negative patients revealed the persistence of chronic organized thrombi. CONCLUSIONS: In patients hospitalized for catheter ablation of AF or LAT, the ATE score identifies a population at very low risk for atrial thrombus. In consultation with the patient, the cardiologist may consider not performing a preoperative TEE in case of an ATE score of 0.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Trombose , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Cardiopatias/diagnóstico , Trombose/epidemiologia
5.
Am J Cardiol ; 206: 89-97, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37690150

RESUMO

Idiopathic dilated cardiomyopathy (IDCM) is one of the most common forms of nonischemic cardiomyopathy worldwide, possibly leading to cardiogenic shock (CS). Despite this heavy burden, the outcomes of CS in IDCM are poorly reported. Based on a large registry of unselected CS, our aim was to shed light on the 1-year outcomes after CS in patients with and without IDCM. FRENSHOCK was a prospective registry including 772 patients with CS from 49 centers. The 1-year outcomes (rehospitalizations, mortality, heart transplantation [HTx], ventricular assist devices [VAD]) were analyzed and adjusted on independent predictive factors. Within 772 CS included, 78 occurred in IDCM (10.1%). Patients with IDCM had more frequent history of chronic kidney failure and implantable cardioverter-defibrillator implantation. No difference was found in 1-month all-cause mortality between groups (28.2 vs 25.8%for IDCM and others, respectively; adjusted hazard ratio 1.14 [0.73 to 1.77], p = 0.57). Patients without IDCM were more frequently treated with noninvasive ventilation and intra-aortic balloon pump. At 1 year, IDCM led to higher rates of death or cardiovascular rehospitalizations (adjusted odds ratio 4.77 [95% confidence interval 1.13 to 20.1], p = 0.03) and higher rates of HTx or VAD for patients aged <65 years (adjusted odds ratio 2.68 [1.21 to 5.91], p = 0.02). In conclusion, CS in IDCM is a very common scenario and is associated with a higher rate of 1-year death or cardiovascular rehospitalizations and a more frequent recourse to HTx or VAD for patients aged <65 years, encouraging the consideration of it as a red flag for myocardial decline and urging for a closer follow-up and earlier evaluation for advanced heart failure therapies.

6.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208302

RESUMO

AIMS: Hyperbaric oxygen therapy (HBOT) is the standard adjuvant treatment for life-threatening or disabling pathologies. Currently, mechanical and electronic variations of implantable cardioverter-defibrillators (ICD) in hyperbaric conditions have not been evaluated. As a result, many patients eligible for HBOT but ICD recipients cannot undergo this therapy, even in emergency situations. METHODS AND RESULTS: Twenty-two explanted ICD of various brands and models were randomized in two groups: single hyperbaric exposure at an absolute pressure of 4000 hPa and 30 iterative hyperbaric exposures at an absolute pressure of 4000 hPa. Mechanical and electronic parameters of these ICD were blindly assessed before, during, and after hyperbaric exposures. Regardless of the hyperbaric exposure, we could not find any mechanical distortion, inappropriate occurrence of anti-tachycardia therapies, dysfunction of tachyarrhythmia therapeutic programming, or dysfunction of programmed pacing parameters. CONCLUSION: Dry hyperbaric exposure seems harmless on ICD tested ex vivo. This result may lead to a reconsideration of the absolute contraindication of emergency HBOT to ICD recipients. A real-life study in these patients with an indication to HBOT should be performed to assess their tolerance to the treatment.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos
7.
Front Cardiovasc Med ; 10: 1148052, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025684

RESUMO

Background: Fat layers in obese patients can impair R-wave detection and diagnostic performance of a subcutaneous insertable cardiac monitor (ICM). We compared safety and ICM sensing quality between obese patients [body mass index (BMI) ≥ 30 kg/m2] and normal-weight controls (BMI <30 kg/m2) in terms of R-wave amplitude and time in noise mode (noise burden) detected by a long-sensing-vector ICM. Materials and methods: Patients from two multicentre, non-randomized clinical registries are included in the present analysis on January 31, 2022 (data freeze), if the follow-up period was at least 90 days after ICM insertion, including daily remote monitoring. The R-wave amplitudes and daily noise burden averaged intraindividually for days 61-90 and days 1-90, respectively, were compared between obese patients (n = 104) and unmatched (n = 268) and a nearest-neighbour propensity score (PS) matched (n = 69) normal-weight controls. Results: The average R-wave amplitude was significantly lower in obese (median 0.46 mV) than in normal-weight unmatched (0.70 mV, P < 0.0001) or PS-matched (0.60 mV, P = 0.003) patients. The median noise burden was 1.0% in obese patients, which was not significantly higher than in unmatched (0.7%; P = 0.056) or PS-matched (0.8%; P = 0.133) controls. The rate of adverse device effects during the first 90 days did not differ significantly between groups. Conclusion: Although increased BMI was associated with reduced signal amplitude, also in obese patients the median R-wave amplitude was >0.3 mV, a value which is generally accepted as the minimum level for adequate R-wave detection. The noise burden and adverse event rates did not differ significantly between obese and normal-weight patients.Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04075084 and NCT04198220.

8.
Heart Rhythm O2 ; 4(2): 97-102, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873314

RESUMO

Background: Insertable cardiac monitors (ICMs) are increasingly used for cardiac rhythm diagnosis with expanding indications. Little has been reported about their use and efficacy. Objective: The study sought to evaluate the clinical utility of a novel ICM (Biotronik BIOMONITOR III) including the time to diagnosis in unselected patients with different ICM indications. Methods: Patients from 2 prospective clinical studies were included to determine the diagnostic yield of the ICM. The primary endpoint was time to clinical diagnosis per implant indication or to the first change in atrial fibrillation (AF) therapy. Results: A total of 632 patients were included with a mean follow-up of 233 ± 168 days. Of 384 patients with (pre)syncope, 34.2% had a diagnosis at 1 year. The most frequent therapy was permanent pacemaker implantation. Of 133 patients with cryptogenic stroke, 16.6% had an AF diagnosis at 1 year, resulting in oral anticoagulation. Of 49 patients with an indication for AF monitoring, 41.0% had a relevant change in AF therapy based on ICM data at 1 year. Of 66 patients with other indications, 35.4% received a rhythm diagnosis at 1 year. Moreover, 6.5% of the cohort had additional diagnoses: 26 of 384 patients with syncope, 8 of 133 patients with cryptogenic stroke, and 7 of 49 patients with AF monitoring. Conclusion: In a large unselected patient population with heterogeneous ICM indications, the primary endpoint of rhythm diagnosis was achieved in ∼1 in 4, and additional clinically relevant findings was achieved in 6.5% of patients at short-term follow-up.

9.
J Am Heart Assoc ; 12(6): e025368, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36926933

RESUMO

Background Cardiac adrenergic receptor gene polymorphisms have the potential to influence risk of developing ventricular fibrillation (VF) during ST-segment-elevation myocardial infarction, but no previous study has comprehensively investigated those most likely to alter norepinephrine release, signal transduction, or biased signaling. Methods and Results In a case-control study, we recruited 953 patients with ST-segment-elevation myocardial infarction without previous cardiac history, 477 with primary VF, and 476 controls without VF, and genotyped them for ADRB1 Arg389Gly and Ser49Gly, ADRB2 Gln27Glu and Gly16Arg, and ADRA2C Ins322-325Del. Within each minor allele-containing genotype, haplotype, or 2-genotype combination, patients with incident VF were compared with non-VF controls by odds ratios (OR) of variant frequencies referenced against major allele homozygotes. Of 156 investigated genetic constructs, 19 (12.2%) exhibited significantly (P<0.05) reduced association with incident VF, and none was associated with increased VF risk except for ADRB1 Gly389 homozygotes in the subset of patients not receiving ß-blockers. ADRB1 Gly49 carriers (prevalence 23.0%) had an OR (95% CI) of 0.70 (0.49-0.98), and the ADRA2C 322-325 deletion (Del) carriers (prevalence 13.5%) had an OR of 0.61 (0.39-0.94). When present in genotype combinations (8 each), both ADRB1 Gly49 carriers (OR, 0.67 [0.56-0.80]) and ADRA2C Del carriers (OR, 0.57 [0.45- 0.71]) were associated with reduced VF risk. Conclusions In ST-segment-elevation myocardial infarction, the adrenergic receptor minor alleles ADRB1 Gly49, whose encoded receptor undergoes enhanced agonist-mediated internalization and ß-arrestin interactions leading to cardioprotective biased signaling, and ADRA2C Del322-325, whose receptor causes disinhibition of norepinephrine release, are associated with a lower incidence of VF. Registration URL: https://clinicaltrials.gov; Unique identifier: NCT00859300.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Fibrilação Ventricular , Humanos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/genética , Estudos de Casos e Controles , Polimorfismo Genético , Receptores Adrenérgicos/genética , Norepinefrina
10.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
11.
Heart Rhythm ; 20(5): 699-706, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36646235

RESUMO

BACKGROUND: New-onset left bundle branch block (LBBB) is one of the most frequent complications after transcatheter aortic valve implantation (TAVI) and is associated with delayed high degree atrioventricular (AV) block. OBJECTIVES: The objectives of this study were to determine the incidence of AV block in such a population and to assess the performance and safety of a risk stratification algorithm on the basis of electrophysiology study (EPS) followed by implantation of a pacemaker or implantable loop recorder (ILR). METHODS: This was a prospective open-label study with 12-month follow-up. From June 8, 2015, to November 8, 2018, 183 TAVI recipients (mean age 82.3 ± 5.9 years) were included at 10 centers. New-onset LBBB after TAVI persisting for >24 hours was assessed by electrophysiology study during initial hospitalization. High-risk patients (His-ventricle interval ≥70 ms) were implanted with a dual-chamber pacemaker recording AV conduction disturbance episodes. Patients at lower risk were implanted with an ILR with automatic remote monitoring. RESULTS: A high-grade AV conduction disorder was identified in 56 patients (30.6%) at 12 months. Four subjects were symptomatic, all in the ILR group. No complications were associated with the stratification procedure. Patients with His-ventricle interval ≥70 ms displayed more high-grade AV conduction disorders (53.2% [25 of 47] vs 22.8% [31 of 136]; P < .001). In a multivariate analysis, His-ventricle interval ≥70 ms was independently associated with the occurrence of a high-grade conduction disorder (subdistribution hazard ratio 2.4; 95% confidence interval 1.2-4.8; P = .010). CONCLUSION: New-onset LBBB after TAVI was associated with high rates of high-grade AV conduction disturbances. The stratification algorithm provided safe and valuable aid to management decisions and reliable guidance on pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Incidência , Estudos Prospectivos , Eletrocardiografia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/etiologia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
12.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36309156

RESUMO

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Volume Sistólico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Seguimentos , Função Ventricular Direita , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular
13.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266008

RESUMO

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Tetralogia de Fallot , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Tetralogia de Fallot/complicações , Estudos de Coortes , Caracteres Sexuais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Cardiopatias Congênitas/complicações
14.
Front Public Health ; 10: 937774, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36249234

RESUMO

Introduction: Welding fumes (WF) are a complex mixture of gas and particles. Action of occupational exposure to WF on cardiovascular system has been recently studied as for noise. Research question: The main objectives of our study are therefore to evaluate the impact of exposure to WF, noise, and combined WF and noise on autonomic nervous system as assessed by heart rate variability (HRV). Methods: The study groups were 16 welders and eight airport workers (as a control group). All the participants underwent ambulatory electrocardiogram, personal WF, and noise exposure monitoring, respectively, with dust track and calibrated noise dosimeter during workday. Atmospheric environmental assessments at workplaces have been also performed. HRV parameters were summarized for all the workday and hourly. Correlation tests were used to examine relation between HRV parameters and levels of noise exposure in the two population. Analysis of covariance (ANCOVA) was used for mean of each HRV parameters. Results: For HRV parameters, we found significant higher levels for mean range of high frequency (HF), standard deviation of normal-to-normal R-R interval (SDNN), and root mean square of successive heartbeat interval difference (RMSSD) in welders which suggested an imbalance between sympathetic and parasympathetic nervous system in this population. For relation between noise and HRV parameters, we noted that levels of low frequency (LF), HF, and SDNN were significantly correlated with mean noise levels for welders (respectively, r = 0.62, r = 0.357, r = 0.48), not in control group. Using ANCOVA, we found that working as a welder significantly increases mean of HF (p = 0.01) and RMSSD (p = 0.02) and decreases in LF/HF (p = 0.008). Indeed, the interaction between exposure to WF and mean noise levels for HF (p = 0.005), LF/HF (p = 0.01), and RMSSD (p = 0.007) was significant. Conclusion: This study shows an impact of WF and noise on ANS balance. One hypothesis is WF exposure could increase sensibility to noise exposure on autonomic nervous system or there is a synergic effect.


Assuntos
Exposição Ocupacional , Soldagem , Aeroportos , Misturas Complexas/farmacologia , Poeira , Frequência Cardíaca/fisiologia , Humanos , Ferreiros , Exposição Ocupacional/efeitos adversos
15.
Diabetes Metab ; 48(6): 101370, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35779852

RESUMO

Evidence shows that smoking increases the risk of pre-diabetes and diabetes in the general population. Among persons with diabetes, smoking has been found to increase the risk of all-cause mortality and aggravate chronic diabetic complications and glycemic control. The current paper, which is a joint position statement by the French-Speaking Society on Tobacco (Société Francophone de Tabacologie) and the French-Speaking Society of Diabetes (Société Francophone du Diabète), summarizes the data available on the association between smoking and diabetes and on the impact of smoking and smoking cessation among individuals with type 1, type 2, and gestational diabetes mellitus. It also provides evidence-based information about the pharmacological and behavioral strategies for smoking cessation in these patients.


Assuntos
Diabetes Mellitus , Humanos , Diabetes Mellitus/epidemiologia , Fumar/efeitos adversos , Fumar/epidemiologia
16.
Heart Rhythm O2 ; 3(2): 152-159, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35496450

RESUMO

Background: Insertable cardiac monitors (ICMs) require an invasive procedure and are used for purely diagnostic purposes. Therefore, simplicity of the insertion procedure, low complication rate, long-term patient acceptance, sensing quality, and reliable remote monitoring are of great importance. Objective: To evaluate a novel ICM (BIOMONITOR III) regarding all these aspects. Methods: BIOMONITOR III has a miniaturized profile, long sensing vector (≈70 mm), a fast insertion tool for pocket formation and ICM placement in 1 step, and daily automatic Home Monitoring (HM) function. We evaluated the insertion procedure, complication rate, patient acceptance, sensing quality, and HM performance in 653 patients with BIOMONITOR III inserted for any ICM indication within 2 ongoing studies involving 51 sites in 11 countries. Results: The median time from skin incision to wound closure was 4.0 minutes (interquartile range, 2.3-6.2 minutes). Median follow-up period was 274 days (interquartile range, 175-342 days). Serious adverse device-related events occurred in 6 patients (0.9%). No deep infections were reported in 334 patients without antibiotic prophylaxis. The wearing comfort was good or excellent in ≈95%. The mean R-wave amplitude (0.73 mV) and HM transmission rate (≈94% of days) were stable over 1.5 years. R-wave amplitudes were larger (mean 0.80 vs 0.62 mV, P < .001) and noise burden was lower (median 3.7 vs 14.5 minutes/day, P < .001) for ICM insertions parallel to the heart's long axis (54.2%) vs parasternal (41.3%). A gross visibility of P waves was 95.1%. Conclusion: The study demonstrated fast insertion times, low complication rate, high patient acceptance, and favorable long-term sensing and HM performance of the ICM.

17.
Heart Rhythm ; 19(8): 1306-1314, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35395407

RESUMO

BACKGROUND: Syncope in patients with an early repolarization (ER) pattern presents a challenge for clinicians as it has been identified as an indicator of a higher risk of life-threatening ventricular arrhythmias (VAs). OBJECTIVES: This study aimed to analyze the outcome of patients with an ER pattern and syncope and to evaluate the factors predictive of VAs. METHODS: Over a period of 5 years, we enrolled 143 patients with an ER pattern and syncope in a multicenter prospective registry. RESULTS: After the initial examinations, 97 patients (67.8%) were implanted with a device allowing electrocardiogram monitoring, including 84 (58.7%) with an implantable loop recorder. During a mean follow-up period of 68 ± 34 months, we documented 16 arrhythmias presumably responsible for syncope (5 VAs, 10 bradycardias, and 1 supraventricular tachycardia). Additionally, recurrent syncope not associated with electrocardiogram documentation occurred in 16 patients (11.2%). The cause of syncope was identified in 23 of 97 patients with a monitoring device (23.8%). The 5-year incidence of VAs and arrhythmic events presumably responsible for syncope was 4.9% and 11.0%, respectively. Patients who developed VAs showed no prodromes or specific triggers at the time of syncope. Neither the presence of a family history of sudden cardiac death nor the previously reported high-risk electrocardiographic parameters differed between patients with and without VAs. CONCLUSION: VAs occurred in 4.9% of patients with an ER pattern and syncope. Device implantation based on detailed history taking seems to be a reasonable strategy. Previously reported high-risk electrocardiographic patterns did not identify patients with VAs.


Assuntos
Eletrocardiografia Ambulatorial , Síncope , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Humanos , Síncope/diagnóstico , Síncope/etiologia
18.
Arch Cardiovasc Dis ; 115(5): 288-294, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35221255

RESUMO

BACKGROUND: The optimal right ventricular pacing site for patients requiring pacemaker implantation for permanent atrioventricular block is a matter of debate. Long-term right ventricular apical pacing has been associated with left ventricular ejection fraction impairment and heart failure. Right ventricular septal pacing has been proposed as an alternative. AIM: The aim of this randomized prospective multicentre trial was to compare left ventricular remodelling and outcomes between right ventricular apical and septal pacing after mid-term follow-up. METHODS: Patients requiring pacemaker implantation for high-degree atrioventricular block were enrolled and randomized in a 1:1 fashion to receive a right ventricular apical or septal lead. RESULTS: A total of 141 patients were included, 69 in the septal group and 72 in the apical group. Both groups exhibited similar left ventricular ejection fractions after 18 months of follow-up (septal 57.1±11.9% vs. apical 57.4±13.4%), and left ventricular ejection fraction variation was similar in the two groups at the end of follow-up (septal -1.5±13.2% vs. apical 0.3±13.3%). Additionally, left ventricular volume, quality of life and 6-minute walk distance were similar in the two groups. However, patients in the septal group were more likely to be asymptomatic, with a significantly lower concentration of N-terminal prohormone of brain natriuretic peptide. Lastly, lead position did not impact 18-month survival. CONCLUSION: Pacing from the right ventricular apex does not have any detrimental effect on left ventricular systolic function compared with septal pacing over an 18-month period.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Estudos Prospectivos , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
19.
J Cardiovasc Electrophysiol ; 33(4): 731-737, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35138039

RESUMO

INTRODUCTION: The aim of this study was to assess the safety and efficacy of the TightRail™ sheath for pacemaker/defibrillator transvenous lead extraction (TLE). METHODS: Multicenter observational study including patients who underwent a TLE with the TightRail™ sheath in five French university hospitals from September 2014 to January 2020. RESULTS: Two hundred and twenty-five patients (76% males, 71 ± 12 years) underwent a TLE procedure with the TightRail™. A total of 438 leads were extracted using the TightRail™, and the mean age of the extracted leads was 128 ± 85 months; of these, 344 (79%) were pacing leads and 94 (21%) were implantable cardioverter defibrillator leads. The overall clinical success of the extraction procedures was 93%. Overall, 410 of the 438 leads (95%) were extracted (complete or incomplete removal). After multilevel mixed-effects logistic regression model, we found that lead age (odds ratio [OR], 95% confidence interval [CI] for a 1 year increase: 1.11 [1.07-1.15], p < .001) and number of leads extracted (OR, 95% CI: 2.09 [1.50-2.96], p < .001) were the two independent factors associated with complete lead removal failure. Finally, there were 7 (3%) cases of major complications but no per-procedural death. CONCLUSION: This is the first large-scale survey assessing the efficacy and safety profile of the Tightrail™ mechanical sheath. The clinical success rate was 93%, and the lead removal failure was dependent on the age and number of leads. We show a satisfactory safety profile in this cohort of patients from primarily low-volume centers with older leads.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
20.
Eur Heart J Acute Cardiovasc Care ; 11(1): 2-9, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-34632490

RESUMO

AIMS: The role of diuretics in patients with intermediate-risk pulmonary embolism (PE) is controversial. In this multicentre, double-blind trial, we randomly assigned normotensive patients with intermediate-risk PE to receive either a single 80 mg bolus of furosemide or a placebo. METHODS AND RESULTS: Eligible patients had at least a simplified PE Severity Index (sPESI) ≥1 with right ventricular dysfunction. The primary efficacy endpoint assessed 24 h after randomization included (i) absence of oligo-anuria and (ii) normalization of all sPESI items. Safety outcomes were worsening renal function and major adverse outcomes at 48 hours defined by death, cardiac arrest, mechanical ventilation, or need of catecholamine. A total of 276 patients underwent randomization; 135 were assigned to receive the diuretic, and 141 to receive the placebo. The primary outcome occurred in 68/132 patients (51.5%) in the diuretic and in 49/132 (37.1%) in the placebo group (relative risk = 1.30, 95% confidence interval 1.04-1.61; P = 0.021). Major adverse outcome at 48 h occurred in 1 (0.8%) patients in the diuretic group and 4 patients (2.9%) in the placebo group (P = 0.19). Increase in serum creatinine level was greater in diuretic than placebo group [+4 µM/L (-2; 14) vs. -1 µM/L (-11; 6), P < 0.001]. CONCLUSION: In normotensive patients with intermediate-risk PE, a single bolus of furosemide improved the primary efficacy outcome at 24 h and maintained stable renal function. In the furosemide group, urine output increased, without a demonstrable improvement in heart rate, systolic blood pressure, or arterial oxygenation.ClinicalTrials.gov identifier NCT02268903.


Assuntos
Embolia Pulmonar , Disfunção Ventricular Direita , Doença Aguda , Diuréticos , Método Duplo-Cego , Furosemida , Humanos , Embolia Pulmonar/tratamento farmacológico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA