Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Pak J Pharm Sci ; 28(6): 1979-84, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26639475

RESUMO

A high-pressure liquid chromatography (HPLC-UV) based simple and specific method for simultaneous quantitative determination of Ofloxacin, Fexofenadine HCl and Diclofenac Potassium has been developed and validated according to ICH guidelines. Chromatographic separation of the three drugs was carried out on 4.6 x 250 mm x 5 µ Licrospher RP Select B Column, using mobile phase constituted of methanol and phosphate buffer pH 3.5 (650: 350), pH adjusted to 3.5 ± 0.05 with dilute ortho-phosphoric acid and delivered at a flow rate of 1 ml/min. The eluents were detected at UV wavelength of 220 nm and the retention times for Ofloxacin, Fexofenadine HCl and Diclofenac Potassium were 2.5 minutes, 4 minutes and 11.5 minutes, respectively. This method is suitable and specific for the three drugs and was found to be linear (R² > 0.996), accurate, specific, reproducible and robust over a concentration range of 0.05 to 0.15 mg/ml for Ofloxacin, 0.015 to 0.045 mg/ml for Fexofenadine HCl and 0.0125 to 0.0375 mg/ml for Diclofenac Potassium. The proposed method is simple and convenient, hence easily utilized for the characterization and quantitation of the three drugs in a single formulation for combination therapy of rheumatoid arthritis, sepsis, infection with fever and flu.


Assuntos
Antibacterianos/análise , Anti-Inflamatórios não Esteroides/análise , Cromatografia Líquida de Alta Pressão , Diclofenaco/análise , Antagonistas não Sedativos dos Receptores H1 da Histamina/análise , Ofloxacino/análise , Espectrofotometria Ultravioleta , Terfenadina/análogos & derivados , Química Farmacêutica , Combinação de Medicamentos , Reprodutibilidade dos Testes , Terfenadina/análise
2.
Pak J Pharm Sci ; 27(5 Spec no): 1553-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25176250

RESUMO

A high-pressure liquid chromatography (HPLC-UV) based simple and specific method for simultaneous quantitative determination of aspirin, amlodipine besylate and simvastatin in a capsule formulation has been developed and validated according to ICH guidelines. Chromatographic separation of the three drugs was carried out by aSpherisorbODS2 reverse phase column (4.6 x 250 mm; 5 µm) using amobile phase, which consisted of 70: 30 (v/v) mixture of acetonitrile and triethylamine phosphate buffer (pH 3; 0.015 M) with final pH adjusted to 2.5 using dilute ortho-phosphoric acid, at a flow rate of 1mL/min. The eluents were detected at UV wavelength of 237 nm and the retention times for aspirin, amlodipine besylate and simvastatin were ~2.7 mins, ~6.1 mins and ~10.5mins, respectively. This method is suitable and specific for the three drugs and was found to be linear (R2>0.995), accurate, specific, reproducible and robust in the concentration range of 375 to 1125mcg/ml for aspirin, 25 to 75mcg/ml for amlodipine besylate and 50 to 150mcg/ml for simvastatin. This simple and convenient method could be easily utilized for the characterization and quantitation of the three drugs in a single formulation for combination therapy of cardiovascular diseases.


Assuntos
Anlodipino/análise , Aspirina/análise , Fármacos Cardiovasculares/análise , Cromatografia Líquida de Alta Pressão , Sinvastatina/análise , Espectrofotometria Ultravioleta , Tecnologia Farmacêutica/métodos , Química Farmacêutica , Cromatografia de Fase Reversa , Combinação de Medicamentos , Limite de Detecção , Reprodutibilidade dos Testes , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA