Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 266
Filtrar
3.
Ophthalmologica ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857572

RESUMO

INTRODUCTION: To examine the association between retinal thickness (RT) fluctuations and best-corrected visual acuity (BCVA) in eyes with neovascular AMD, macular edema secondary to RVO, and DME treated with anti-VEGF therapy. METHODS: A systematic search of Ovid MEDLINE, EMBASE, and the Cochrane Library was performed from January 2006 to March 2024. Studies comparing visual or anatomic outcomes of patients treated with anti-VEGF therapy, stratified by magnitudes of RT fluctuation, were included. ROBINS-I and Cochrane RoB 2 tools were used to assess risk of bias, and certainty of evidence was evaluated with GRADE criteria. Meta-analysis was performed with a random effects model. Primary outcomes were final BCVA and change in BCVA relative to baseline. RESULTS: 15725 articles were screened; 15 studies were identified in the systematic review and 5 studies were included in the meta-analysis. Final ETDRS VA was significantly worse in eyes with the highest level of RT fluctuation (weighted mean difference (WMD) = 7.86 letters; 95% CI, 4.97, 10.74; p < 0.00001; I² = 81%; 3136 eyes). RT at last observation was significantly greater in eyes with high RT fluctuations (WMD = -27.35 µm; 95% CI, -0.04, 54.75; p = 0.05; I2 = 88%; 962 eyes). CONCLUSIONS: Final visual outcome is associated with magnitude of RT fluctuation over the course of therapy. It is unclear whether minimizing RT fluctuations would help to optimize visual outcomes in patients treated with anti-VEGF therapy. These findings are limited by a small set of studies, risk of bias, and considerable heterogeneity.

4.
Ophthalmic Epidemiol ; : 1-8, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833629

RESUMO

PURPOSE: To elicit associations between vision difficulties and physical or psychosocial challenges in children in the United States. METHODS: Children aged 2-17 years old from the 2021 National Health Interview Survey with data pertaining to vision difficulty were included in our retrospective, population-based analysis. Our primary aim was investigating physical and psychosocial challenges as predictors of vision difficulty. Logistic regression models were performed on Stata version 17.0 (StataCorp LLC, College Station, Texas). Analyses were accompanied by an odds ratio (OR) and 95% confidence interval (CI). RESULTS: A total of 7,373 children had data pertaining to their level of vision difficulty and were included in our sample. In our multivariable analysis, children with a good/fair (OR = 1.84, 95% CI = [1.31, 2.60], p < 0.01), or poor (OR = 5.08, 95% CI = [1.61, 16.04], p < 0.01) general health status had higher odds of vision difficulty relative to children with an excellent/very good health status. Furthermore, children with difficulties hearing (OR = 8.67, 95% CI = [5.25, 14.31], p < 0.01), communicating (OR = 1.96, 95% CI = [1.18, 3.25], p < 0.01), learning (OR = 1.93, 95% CI = [1.27, 2.93], p < 0.01), and making friends (OR = 1.94, 95% CI = [1.12, 3.36], p = 0.02) had higher odds of vision difficulty. Nonetheless, the following factors were only predictors of vision difficulty in our univariable analysis: requiring equipment for mobility (p < 0.01), experiencing anxiety (p < 0.01), and experiencing depression (p < 0.01). CONCLUSION: Several factors pertaining to physical and psychosocial challenges in children are associated with vision difficulty. Future research should further explore potential causal links between vision difficulty and physical or psychosocial factors to aid in coordinating public health efforts dedicated to vision health equity.

5.
Ophthalmology ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38878904

RESUMO

OBJECTIVE: Complications associated with intravitreal anti-vascular endothelial growth factor (VEGF) therapies are inconsistently reported in the literature, thus limiting an accurate evaluation and comparison of safety between studies. This study aimed to develop a standardized classification system for anti-VEGF ocular complications using the Delphi consensus process. DESIGN: Systematic review and Delphi consensus process. PARTICIPANTS: 25 international retinal specialists participated in the Delphi consensus survey. METHODS: A systematic literature search was conducted to identify complications of intravitreal anti-VEGF agent administration based on randomized controlled trials (RCTs) of anti-VEGF therapy. A comprehensive list of complications was derived from these studies, and this list was subjected to iterative Delphi consensus surveys involving international retinal specialists that voted on inclusion, exclusion, rephrasing, and addition of complications. As well, surveys determined specifiers for the selected complications. This iterative process helped refine the final classification system. MAIN OUTCOME MEASURES: The proportion of retinal specialists who choose to include or exclude complications associated with anti-VEGF administration. RESULTS: After screening 18,229 articles, 130 complications were initially categorized from 145 included RCTs. Participant consensus via the Delphi method resulted in the inclusion of 91 (70%) complications after three rounds. After incorporating further modifications made based on participant suggestions, such as rewording certain phrases and combining similar terms, 24 redundant complications were removed, leaving a total of 67 (52%) complications in the final list. A total of 14 (11%) complications met exclusion thresholds and were eliminated by participants across both rounds. All other remaining complications not meeting inclusion or exclusion thresholds were also excluded from the final classification system after the Delphi process terminated. In addition, 47 out of 75 (63%) proposed complication specifiers were included based on participant agreement. CONCLUSION: Using the Delphi consensus process, a comprehensive, standardized classification system consisting of 67 ocular complications and 47 unique specifiers was established for intravitreal anti-VEGF agents in clinical trials. The adoption of this system in future trials could improve consistency and quality of adverse event reporting, potentially facilitating more accurate risk-benefit analyses.

6.
Ophthalmologica ; : 1-9, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38723611

RESUMO

INTRODUCTION: This study aimed to investigate the incidence of and risk factors for epiretinal membrane (ERM) formation following primary rhegmatogenous retinal detachment (RRD) repair. METHODS: This comparative, retrospective, single-center cohort study included eyes with primary RRD treated between 2011 and 2023 at Massachusetts Eye and Ear, Boston, Massachusetts, with pars plana vitrectomy (PPV), scleral buckle (SB), PPV+SB, or pneumatic retinopexy (PnR). Demographic, clinical, and surgical parameters were collected from medical records. The primary outcome was the risk of ERM formation, while the secondary outcome was the risk of ERM requiring surgery. Univariable and multivariable Cox regression were performed, and a hazard ratio (HR) and 95% confidence interval (95% CI) were reported. RESULTS: Overall, 394 eyes were included. The mean age was 58.49 ± 12.8 years, and most patients were male. There was a significantly lower risk of ERM formation following SB compared to PPV in the univariable analysis (HR = 0.2, 95% CI = 0.08-0.60, p = 0.003); however, there was no significant association between treatment modality and ERM formation on multivariable Cox regression controlling for confounding factors (p = 0.24). ERM formation was found more commonly in patients who were older (HR = 1.0 per 1 year increase in age, 95% CI = 1.01-1.04, p = 0.001), those with worse baseline visual acuity (HR = 1.3, 95% CI = 1.09-1.71, p = 0.008), and those with macula-off RRDs (HR = 2.1, 95% CI = 1.41-3.32, p < 0.001). CONCLUSION: Surgical modality does not have a significant impact on the risk of ERM following retinal detachment repair. However, age, baseline visual acuity, and macular status are important predictors of ERM formation after RRD repair.

7.
Am J Ophthalmol ; 266: 144-155, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38815844

RESUMO

PURPOSE: To compare the efficacy and safety of pars plana vitrectomy (PPV) with silicone oil compared to gas tamponade for uncomplicated rhegmatogenous retinal detachment (RRD). DESIGN: Systematic review and meta-analysis. METHODS: A systematic literature search was conducted on Ovid MEDLINE, Embase, and the Cochrane Library from January 2000 to September 2023 for comparative studies evaluating the efficacy and safety of PPV with either silicone oil or gas tamponade in the setting of uncomplicated RRD. Our primary outcome was best-corrected visual acuity at the last study observation. Secondary outcomes included the rates of retinal reattachment, retinal thickness, and the incidence of adverse events. We performed a meta-analysis using a random-effects model. RESULTS: Nine observational studies reporting on 491 RRD eyes were included. The mean best-corrected visual acuity at the last study observation was significantly better in the gas tamponade group than in the silicone oil group (weighted mean difference [WMD] = 0.17 logMAR, 95% confidence interval [CI] = [0.06, 0.27], P = .002). Rates of primary retinal reattachment were similar between the silicone oil and gas tamponade groups (P = .89). The ganglion cell layer was significantly thinner in the silicone oil group compared to the gas tamponade group (WMD =-3.70 µm, 95% CI = [-5.87, -1.53, P = .0008), as was the inner plexiform layer (WMD = -2.45, 95% CI = [-4.50, -0.40], P = .02) and outer nuclear layer (WMD = -11.74 µm, 95% CI = [-18.39, -5.10], P = .0005). CONCLUSIONS: PPV with gas tamponade was associated with better functional outcomes compared to PPV with silicone oil, although both tamponades yielded comparable primary reattachment rates. The absence of randomized trials and the potential for selection bias underscore the importance of further investigation in diverse patient populations.

8.
Angew Chem Int Ed Engl ; : e202407147, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742485

RESUMO

Coinage metals Cu, Ag, and Au are essential for modern electronics and their recycling from waste materials is becoming increasingly important to guarantee the security of their supply. Designing new sustainable and selective procedures that would substitute currently used processes is crucial. Here, we describe an unprecedented approach for the sequential dissolution of single metals from Cu, Ag, and Au mixtures using biomass-derived ionic solvents and green oxidants. First, Cu can be selectively dissolved in the presence of Ag and Au with a choline chloride/urea/H2O2 mixture, followed by the dissolution of Ag in lactic acid/H2O2. Finally, the metallic Au, which is not soluble in either solution above, is dissolved in choline chloride/urea/Oxone. Subsequently, the metals were simply and quantitatively recovered from dissolutions, and the solvents were recycled and reused. The applicability of the developed approach was demonstrated by recovering metals from electronic waste substrates such as printed circuit boards, gold fingers, and solar panels. The dissolution reactions and selectivity were explored with different analytical techniques and DFT calculations. We anticipate our approach will pave a new way for the contemporary and sustainable recycling of multi-metal waste substrates.

9.
Eye (Lond) ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615098

RESUMO

PURPOSE: With the popularization of ChatGPT (Open AI, San Francisco, California, United States) in recent months, understanding the potential of artificial intelligence (AI) chatbots in a medical context is important. Our study aims to evaluate Google Gemini and Bard's (Google, Mountain View, California, United States) knowledge in ophthalmology. METHODS: In this study, we evaluated Google Gemini and Bard's performance on EyeQuiz, a platform containing ophthalmology board certification examination practice questions, when used from the United States (US). Accuracy, response length, response time, and provision of explanations were evaluated. Subspecialty-specific performance was noted. A secondary analysis was conducted using Bard from Vietnam, and Gemini from Vietnam, Brazil, and the Netherlands. RESULTS: Overall, Google Gemini and Bard both had accuracies of 71% across 150 text-based multiple-choice questions. The secondary analysis revealed an accuracy of 67% using Bard from Vietnam, with 32 questions (21%) answered differently than when using Bard from the US. Moreover, the Vietnam version of Gemini achieved an accuracy of 74%, with 23 (15%) answered differently than the US version of Gemini. While the Brazil (68%) and Netherlands (65%) versions of Gemini performed slightly worse than the US version, differences in performance across the various country-specific versions of Bard and Gemini were not statistically significant. CONCLUSION: Google Gemini and Bard had an acceptable performance in responding to ophthalmology board examination practice questions. Subtle variability was noted in the performance of the chatbots across different countries. The chatbots also tended to provide a confident explanation even when providing an incorrect answer.

10.
World J Psychiatry ; 14(4): 582-599, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38659600

RESUMO

BACKGROUND: Women with a history of serious psychotic disorders are at increased risk of disease relapse during pregnancy. Long-acting injectable (LAI) antipsychotics have been widely used to improve adherence and prevent relapse in patients with various severe psychotic disorders, but there is a lack of high-quality data from previous research on the safety of LAI antipsychotics during pregnancy. AIM: To summarize relevant data on maternal, pregnancy, neonatal, and developmental outcomes from published cases of LAI antipsychotic use in pregnancy. METHODS: A literature search was performed through November 11, 2023, using three online databases: PubMed/MEDLINE, Scopus, and Web of Science. Case reports or case series that reported information about the outcomes of pregnancy in women who used LAI antipsychotics at any point in pregnancy, with available full texts, were included. Descriptive statistics, narrative summation, and tabulation of the extracted data were performed. RESULTS: A total of 19 publications satisfied the inclusion criteria: 3 case series, 15 case reports, and 1 conference abstract. They reported the outcomes of LAI antipsychotic use in 74 women and 77 pregnancies. The use of second-generation LAI antipsychotics was reported in the majority (n = 47; 61.0%) of pregnancies. First-generation LAI antipsychotics were administered during 30 pregnancies (39.0%). Most of the women (approximately 64%) had either satisfactory control of symptoms or no information about relapse, while approximately 12% of them had developed gestational diabetes mellitus. A minority of cases reported adverse outcomes such as stillbirth, spontaneous abortion, preterm birth, low birth weight, congenital anomalies, and neurological manifestations in newborns. However, there were no reports of negative long-term developmental outcomes. CONCLUSION: Currently available data seem reassuring, but further well-designed studies are required to properly evaluate the risks and benefits of LAI antipsychotic use during pregnancy.

13.
Ophthalmic Surg Lasers Imaging Retina ; 55(7): 400-407, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38531020

RESUMO

BACKGROUND AND OBJECTIVE: This review consolidates findings from studies that used a preoperative visual acuity (VA) threshold as an indication for epiretinal membrane (ERM) surgery. METHODS: The literature was systematically searched using Ovid MEDLINE, EMBASE, and Cochrane Library from January 2000 to October 2022 to select studies reporting on pars plana vitrectomy (PPV) for ERM that used a preoperative VA threshold as an inclusion criterion. Primary outcomes were final best-corrected visual acuity (BCVA) and change in BCVA relative to baseline. Secondary outcomes included risk of intra- and postoperative complications. RESULTS: A total of 639 eyes from seven studies were included. The most liberal preoperative VA threshold was 20/28.5 or worse, whereas the most conservative threshold was worse than 20/60. The mean preoperative BCVA was 0.55 logarithm of the minimum angle of resolution (logMAR) (∼20/70), and the mean postoperative BCVA was 0.35 logMAR (∼20/45). Generally, VA improved relative to baseline, regardless of the preoperative VA threshold. The smallest improvement in VA was observed in a study where the pre-operative VA to consider surgery was liberal (20/30 or worse), whereas the greatest VA improvement was observed in a study that used a conservative preoperative VA threshold (worse than 20/60). CONCLUSIONS: The greatest improvement in BCVA was observed in studies where a conservative pre-operative VA threshold was used. The decision to operate should involve a patient-centered approach with a thorough discussion of the risks and benefits of PPV, regardless of the preoperative VA threshold used. [Ophthalmic Surg Lasers Imaging Retina 2024;55:400-407.].


Assuntos
Membrana Epirretiniana , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Acuidade Visual/fisiologia , Membrana Epirretiniana/cirurgia , Membrana Epirretiniana/fisiopatologia , Período Pré-Operatório
14.
Opt Lett ; 49(5): 1153-1156, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426961

RESUMO

In this Letter, we theoretically investigate the application of a bistable Fabry-Perot semiconductor laser under optical injection as an all-optical activation unit for multilayer perceptron optical neural networks. The proposed device is programmed to provide reconfigurable sigmoid-like activation functions with adjustable thresholds and saturation points and benchmarked on machine learning image recognition problems. Due to the reconfigurability of the activation unit, the accuracy can be increased by up to 2% simply by adjusting the control parameter of the activation unit to suit the specific problem. For a simple two-layer perceptron neural network, we achieve inference accuracies of up to 95% and 85%, for the MNIST and Fashion-MNIST datasets, respectively.

15.
J Chem Phys ; 160(9)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38450733

RESUMO

We review the GPAW open-source Python package for electronic structure calculations. GPAW is based on the projector-augmented wave method and can solve the self-consistent density functional theory (DFT) equations using three different wave-function representations, namely real-space grids, plane waves, and numerical atomic orbitals. The three representations are complementary and mutually independent and can be connected by transformations via the real-space grid. This multi-basis feature renders GPAW highly versatile and unique among similar codes. By virtue of its modular structure, the GPAW code constitutes an ideal platform for the implementation of new features and methodologies. Moreover, it is well integrated with the Atomic Simulation Environment (ASE), providing a flexible and dynamic user interface. In addition to ground-state DFT calculations, GPAW supports many-body GW band structures, optical excitations from the Bethe-Salpeter Equation, variational calculations of excited states in molecules and solids via direct optimization, and real-time propagation of the Kohn-Sham equations within time-dependent DFT. A range of more advanced methods to describe magnetic excitations and non-collinear magnetism in solids are also now available. In addition, GPAW can calculate non-linear optical tensors of solids, charged crystal point defects, and much more. Recently, support for graphics processing unit (GPU) acceleration has been achieved with minor modifications to the GPAW code thanks to the CuPy library. We end the review with an outlook, describing some future plans for GPAW.

17.
Retina ; 44(5): 747-755, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437843

RESUMO

PURPOSE: To assess efficacy and safety outcomes of subretinal fluid drainage methods during pars plana vitrectomy for rhegmatogenous retinal detachment. METHODS: A systematic search strategy was conducted for studies published between January 2000 and October 2022. Included studies reported on either the safety or efficacy of two or more drainage methods during pars plana vitrectomy for patients with rhegmatogenous retinal detachment. RESULTS: Two randomized and five observational studies consisting of 1,524 eyes were included. Best-corrected visual acuity at the last study observation and primary reattachment rates were similar across groups. A significantly lower risk of epiretinal membrane formation was associated with draining subretinal fluid through preexisting retinal breaks (risk ratio = 0.70, 95% confidence interval = [0.60, 0.83], P = <0.01, I 2 = 0%) or with perfluorocarbon liquid (risk ratios = 0.70, 95% confidence interval = [0.59, 0.83], P = <0.01, I 2 = 0%) compared with posterior retinotomy. The risk of an abnormal foveal contour was significantly greater in perfluorocarbon liquid-treated eyes relative to posterior retinotomy (risk ratios = 1.56, 95% confidence interval = [1.13, 2.17], P = <0.01, I 2 = 0%). CONCLUSION: No significant differences were observed in the final best-corrected visual acuity at the last study observation and primary reattachment rates across different drainage methods. There remains limited information on the topic, so future research is warranted.


Assuntos
Drenagem , Descolamento Retiniano , Vitrectomia , Humanos , Drenagem/métodos , Descolamento Retiniano/cirurgia , Líquido Sub-Retiniano , Acuidade Visual/fisiologia , Vitrectomia/métodos
19.
Retina ; 44(7): 1115-1123, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38478760

RESUMO

PURPOSE: To investigate the correlation between diabetic retinopathy (DR) severity and microscopic retinal and vascular alterations using adaptive optics imaging. METHODS: In this single-center, prospective cohort study, adult participants with healthy eyes or DR underwent adaptive optics imaging. Participants were classified into control/mild nonproliferative DR, moderate/severe nonproliferative DR, and proliferative DR. Adaptive optics imaging using the RTX1 camera was obtained from 48 participants (87 eyes) for photoreceptor data and from 36 participants (62 eyes) for vascular data. RESULTS: Photoreceptor parameters significantly differed between DR groups at 2° and 4° of retinal eccentricity. Wall-to-lumen ratio varied significantly at 2° eccentricity, while other vascular parameters remained nonsignificant. Cone density and dispersion were the strongest predictors for DR severity ( P < 0.001) in multivariable generalized estimating equation modeling, while other vascular parameters remained nonsignificant between DR severity groups. All photoreceptor parameters showed significant correlations with visual acuity overall and across most DR severity groups. CONCLUSION: To date, this is one of the largest studies evaluating the use of adaptive optics imaging in DR. Adaptive optics imaging was demonstrated to differentiate between various levels of disease severity in DR. These results support the potential role in diagnostic and therapeutic microstructural evaluation in research and clinical practice.


Assuntos
Retinopatia Diabética , Acuidade Visual , Humanos , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/fisiopatologia , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Adulto , Idoso , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia
20.
JAMA Ophthalmol ; 142(4): 321-326, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38421670

RESUMO

Importance: Ophthalmology is reliant on effective interpretation of multimodal imaging to ensure diagnostic accuracy. The new ability of ChatGPT-4 (OpenAI) to interpret ophthalmic images has not yet been explored. Objective: To evaluate the performance of the novel release of an artificial intelligence chatbot that is capable of processing imaging data. Design, Setting, and Participants: This cross-sectional study used a publicly available dataset of ophthalmic cases from OCTCases, a medical education platform based out of the Department of Ophthalmology and Vision Sciences at the University of Toronto, with accompanying clinical multimodal imaging and multiple-choice questions. Across 137 available cases, 136 contained multiple-choice questions (99%). Exposures: The chatbot answered questions requiring multimodal input from October 16 to October 23, 2023. Main Outcomes and Measures: The primary outcome was the accuracy of the chatbot in answering multiple-choice questions pertaining to image recognition in ophthalmic cases, measured as the proportion of correct responses. χ2 Tests were conducted to compare the proportion of correct responses across different ophthalmic subspecialties. Results: A total of 429 multiple-choice questions from 136 ophthalmic cases and 448 images were included in the analysis. The chatbot answered 299 of multiple-choice questions correctly across all cases (70%). The chatbot's performance was better on retina questions than neuro-ophthalmology questions (77% vs 58%; difference = 18%; 95% CI, 7.5%-29.4%; χ21 = 11.4; P < .001). The chatbot achieved a better performance on nonimage-based questions compared with image-based questions (82% vs 65%; difference = 17%; 95% CI, 7.8%-25.1%; χ21 = 12.2; P < .001).The chatbot performed best on questions in the retina category (77% correct) and poorest in the neuro-ophthalmology category (58% correct). The chatbot demonstrated intermediate performance on questions from the ocular oncology (72% correct), pediatric ophthalmology (68% correct), uveitis (67% correct), and glaucoma (61% correct) categories. Conclusions and Relevance: In this study, the recent version of the chatbot accurately responded to approximately two-thirds of multiple-choice questions pertaining to ophthalmic cases based on imaging interpretation. The multimodal chatbot performed better on questions that did not rely on the interpretation of imaging modalities. As the use of multimodal chatbots becomes increasingly widespread, it is imperative to stress their appropriate integration within medical contexts.


Assuntos
Glaucoma , Oftalmologia , Criança , Humanos , Inteligência Artificial , Estudos Transversais , Retina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA