Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Acta Orthop Belg ; 90(1): 46-50, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669648

RESUMO

Chronic pain and functional limitations caused by coxarthrosis are important factors in the onset of depression, as there are higher rates of depression in this group of patients than in the general population. Total hip arthroplasty (THA) has been shown to decrease pain and improve function in these patients, which may positively influence the patient's depressive symptoms. The objectives of the study are to evaluate the differences between patients with depression and patients without depression in the immediate postoperative period (pain and hospitalization time) and to evaluate functional outcomes one year after surgery. Therefore, we conducted a prospective cohort study in which all patients with indications for primary total hip arthroplasty during 2018 were included. Preoperatively, patients completed the PHQ-9 questionnaire, and were classified into patients with depression (if preoperative PHQ-9 > or = to 10) and patients without depression (pre PHQ-9 < to 10). During the hospital stay, postoperative pain was assessed by VAS, and the need for analgesic rescue with major opioids. One year after surgery, the PHQ-9 test was retaken, and functional outcomes were assessed. The results showed that both groups were comparable in terms of sex, age, BMI, and ASA. No differences were found in postoperative pain or hospitalization time. There were also no differences between the two groups of patients in functional outcomes one year after surgery. Therefore, we can conclude that patients with a diagnosis of depression do not present worse postoperative pain after THA. In addition, they show a significant improvement in their depressive symptoms one year after surgery.


Assuntos
Artroplastia de Quadril , Depressão , Dor Pós-Operatória , Humanos , Artroplastia de Quadril/efeitos adversos , Feminino , Masculino , Estudos Prospectivos , Depressão/etiologia , Dor Pós-Operatória/psicologia , Dor Pós-Operatória/etiologia , Idoso , Pessoa de Meia-Idade , Medição da Dor , Osteoartrite do Quadril/cirurgia , Tempo de Internação , Inquéritos e Questionários
2.
Rev Esp Cir Ortop Traumatol ; 66(3): 182-188, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35590435

RESUMO

INTRODUCTION: Hip resurfacing arthroplastys are a valid alternative for the treatment of degenerative hip disorders in young adults. Poor results and adverse soft tissue effects have been reported with high levels of chromium and cobalt, limiting its indications. Objective is to analyze clinical and functional survival results of the Durom system 10 years after its implementation in a public hospital. The hypothesis is that better results and survival are obtained in patients selected according to FDA criteria. MATERIAL AND METHODS: Retrospective cohort study of 83 patients, 91 hips in 76 men and 7 women operated between 2005 and 2013 with Durom-type prostheses. Demographic study, diagnosis, BMI, radiological study, serum chromium cobalt levels, functional assessment according to MPD and HSS, complications and survival at 10 years of follow-up. A cohort of active men under 65 years of age and heads over 48mm is selected. RESULTS: Follow-up time of 121 months with a range from 84 to 176 months. With a mean age of 52.78 years, with 4 deaths and loss of follow-up of 3 cases. There are 12 complications that require reoperation (14.45%) with 2 chronic infections, 4 femoral neck fractures, 4 acetabular loosening and 2 cases of pseudotumors. With an overall survival of 85.4% (71-91.9) and 87.85% (85.5-91.1) in the absence of infection. No statistical relationship between complications and neck narrowing and the angles of inclination of the components. In selected patients, 69 men and 73 hips, we obtained an overall survival of 91.82% and excluding infection of 93.18% at 10 years. CONCLUSIONS: The indication of the Durom system in the treatment of degenerative processes in selected active young patients presents better results and survival at 10 years, although somewhat lower than other highly indicated veneering models.

3.
Acta Ortop Mex ; 35(3): 266-270, 2021.
Artigo em Espanhol | MEDLINE | ID: mdl-34921536

RESUMO

Intraoperative acetabular fractures (IAF) is a rare complication with an incidence 2% - 5%. We present the review of a series of 13 cases, discussing diagnosis, treatment and results. MATERIAL AND METHODS: Between 2006 and 2018, we performed 4800 primary hip arthroplasties (THA) In our hospital, we identified 13 cases with FIA with a follow-up of 38.3 months. RESULTS: Two cases were stable with conservative management; 11 unstable cases: seven cases we placed trabecular metal, one case we increased acetabular diameter, one case acetabular replacement, one case revision with Ganz type ring and one case do not accept treatment. The use of trabecular metal is an implant that helps effectively and with good results in FIA. CONCLUSION: These fractures are rare, knowing the implant to use is mandatory because if the implants are oversized, with greater rigidity or hemispheric, patients have increased risk of suffering from this complication.


Las fracturas intraoperatorias acetabulares (FIA) son una complicación rara con incidencia de 2 a 5%. Presentamos la revisión de una serie de 13 casos, que aborda diagnóstico, tratamiento y resultados. Material y métodos: entre 2006 y 2018 realizamos 4,800 artroplastías primarias de cadera (ATC). En nuestro hospital identificamos 13 casos con FIA con un seguimiento de 38.3 meses. Resultados: Dos casos fueron estables con manejo conservador; 11 casos inestables: en siete casos colocamos trabecular metal, en un caso aumentamos diámetro acetabular, en un caso recambio de cotilo, en un caso revisión con anillo tipo Ganz y un caso no aceptó tratamiento. El uso de trabecular metal es un implante que ayuda eficazmente y con buenos resultados en FIA. Conclusión: Estas fracturas son raras, conocer el implante a utilizar es imperativo, ya que si los implantes están sobredimensionados, con mayor rigidez o hemisféricos, los pacientes tienen mayor riesgo de sufrir esta complicación.

4.
Acta ortop. mex ; 35(3): 266-270, may.-jun. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1374182

RESUMO

Resumen: Las fracturas intraoperatorias acetabulares (FIA) son una complicación rara con incidencia de 2 a 5%. Presentamos la revisión de una serie de 13 casos, que aborda diagnóstico, tratamiento y resultados. Material y métodos: entre 2006 y 2018 realizamos 4,800 artroplastías primarias de cadera (ATC). En nuestro hospital identificamos 13 casos con FIA con un seguimiento de 38.3 meses. Resultados: Dos casos fueron estables con manejo conservador; 11 casos inestables: en siete casos colocamos trabecular metal, en un caso aumentamos diámetro acetabular, en un caso recambio de cotilo, en un caso revisión con anillo tipo Ganz y un caso no aceptó tratamiento. El uso de trabecular metal es un implante que ayuda eficazmente y con buenos resultados en FIA. Conclusión: Estas fracturas son raras, conocer el implante a utilizar es imperativo, ya que si los implantes están sobredimensionados, con mayor rigidez o hemisféricos, los pacientes tienen mayor riesgo de sufrir esta complicación.


Abstract: Intraoperative acetabular fractures (IAF) is a rare complication with an incidence 2% - 5%. We present the review of a series of 13 cases, discussing diagnosis, treatment and results. Material and methods: Between 2006 and 2018, we performed 4800 primary hip arthroplasties (THA) In our hospital, we identified 13 cases with FIA with a follow-up of 38.3 months. Results: Two cases were stable with conservative management; 11 unstable cases: seven cases we placed trabecular metal, one case we increased acetabular diameter, one case acetabular replacement, one case revision with Ganz type ring and one case do not accept treatment. The use of trabecular metal is an implant that helps effectively and with good results in FIA. Conclusion: These fractures are rare, knowing the implant to use is mandatory because if the implants are oversized, with greater rigidity or hemispheric, patients have increased risk of suffering from this complication.

5.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33279444

RESUMO

INTRODUCTION: The correct closure of the surgical wound is an important step in the procedure of a total hip prosthesis implantation (total hip arthroplasty, THA), which aims to a correct healing of the wound and minimize the risk of complications. The objective of our study is to determine if the use of a bidirectional barbed suture decreases the closing time after THA, in the fascial and subcutaneous plane, when compared to the conventional suture polyglactin 910. The hypothesis is that there is no difference in closing time when comparing both sutures. MATERIAL AND METHOD: Prospective single blind randomized study comparing two groups: study group with the use of bidirectional continuous barbed suture (Quill™) (Gr. Q) and a control group (Gr. V) using discontinuous polyglactin 91 suture (Vicryl™). Closure was performed in two planes (fascial and subcutaneous) simultaneously by two surgeons. The exclusion criteria were: previous surgeries on the same hip, revision surgeries, major deformities and allergies to suture components. The variables under study were: 1) fascia closure time, subcutaneous and global; 2) surgical wound infection; and 3) dehiscence. RESULTS: 82 patients (39 Gr. Q, 43 Gr. V) were included. The global closing time was shorter in Gr. Q (5 min 59 sec) compared to Gr. V (7.01 min), (p < 0.04). They showed differences in subcutaneous closure: Gr. Q shorter time with a 37 seconds difference (p = 0.048). Differences in fascial plane were not observed. Superficial infection was observed in one Gr. Q patient and another in Gr. V; one case of deep infection in Gr. Q (p = 0.29). One patient presented dehiscence of the wound in Gr. Q (p = 0.3). However, these differences did not show statistical significance. CONCLUSIONS: The use of a barbed suture allows a shorter closing time compared to the conventional one. However, despite this decrease in time, no differences were found in terms of the appearance of infection or wound dehiscence.

6.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32800719

RESUMO

INTRODUCTION: Complex femoral defects with insufficient isthmus (Paprosky III and IV) and Vancouver B3 periprosthetic fractures determines the fixation of the revision stems. The objective is to evaluate the results of the modular revision stems with diaphyseal anchor and distal block (Revitan Zimmer Biomet GmbH, Winterthur, Switzerland). Our hypothesis is that this procedure offers a stable primary fixation in cases of alteration of the femoral isthmus. MATERIAL AND METHODS: Retrospective cohort study of 38 patients, minimum follow-up of 12 months (12-94) with severe femoral defects treated with Revitan stems distally blocked. An endofemoral or transfemoral approach was used. The subsidence was assessed according to Callahan's method and bone neoformation according to Nordin. Merle d'Aubigné-Postel was used and complications and reoperations were collected. A statistical analysis was performed with SPSS and a significance level p < 0.05 was considered. RESULTS: Between 2009 and 2017, 147 revisions were carried out with Revitan stem, 38 locked, 23 men and 15 women, with an average age of 74 years and an average follow-up of 64 months. The cause of the review was: 15 septic loosenings, 14 aseptic, two fractures and seven stable fibrous unions. Right fixation was obtained in 27 cases, there were four loosenings, three screw breakages, three infections, one of dislocation and one of femoral nerve injury. The MDP increased significantly from 11.26 to 14.98. CONCLUSIONS: Distally locked conical modular stems are a good alternative in femoral defects with isthmus involvement if proper canal filling and bicortical screw fixation are achieved.


Assuntos
Artroplastia de Quadril/métodos , Parafusos Ósseos , Prótese Ancorada no Osso , Osteotomia/métodos , Reoperação/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Diáfises/cirurgia , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur/anormalidades , Seguimentos , Fraturas Mal-Unidas/diagnóstico por imagem , Fraturas Mal-Unidas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Âncoras de Sutura
7.
Acta Ortop Mex ; 31(4): 202-205, 2017.
Artigo em Espanhol | MEDLINE | ID: mdl-29216697

RESUMO

We study, apropos of a case, a total hip arthroplasty in a patient with osteogenesis imperfecta. The characteristics of this disease, such as high risk of fracture and the presence of deformities, make this surgery a challenge for the orthopedic surgeon. In this manuscript, we review for the first time in this indication the preoperative planning and the selection of implants, with special emphasis on measures for the prevention of complications.


En este trabajo se ha estudiado, a propósito de un caso, la cirugía de artroplastía total de cadera en un paciente con osteogénesis imperfecta. Las características propias de esta enfermedad, como son el elevado riesgo de fractura y la presencia de deformidades, convierten esta cirugía en un reto para el cirujano ortopédico. En este manuscrito se revisa, de forma inédita para esta indicación, la planificación preoperatoria y la elección del tipo de implantes, con especial interés en las medidas para la prevención de complicaciones.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Osteogênese Imperfeita , Fraturas Ósseas/etiologia , Fraturas Ósseas/cirurgia , Humanos , Osteogênese Imperfeita/complicações , Osteogênese Imperfeita/cirurgia
8.
Acta ortop. mex ; 31(4): 202-205, jul.-ago. 2017. graf
Artigo em Espanhol | LILACS | ID: biblio-886566

RESUMO

Resumen: En este trabajo se ha estudiado, a propósito de un caso, la cirugía de artroplastía total de cadera en un paciente con osteogénesis imperfecta. Las características propias de esta enfermedad, como son el elevado riesgo de fractura y la presencia de deformidades, convierten esta cirugía en un reto para el cirujano ortopédico. En este manuscrito se revisa, de forma inédita para esta indicación, la planificación preoperatoria y la elección del tipo de implantes, con especial interés en las medidas para la prevención de complicaciones.


Abstract: We study, apropos of a case, a total hip arthroplasty in a patient with osteogenesis imperfecta. The characteristics of this disease, such as high risk of fracture and the presence of deformities, make this surgery a challenge for the orthopedic surgeon. In this manuscript, we review for the first time in this indication the preoperative planning and the selection of implants, with special emphasis on measures for the prevention of complications.


Assuntos
Humanos , Osteogênese Imperfeita/cirurgia , Osteogênese Imperfeita/complicações , Artroplastia de Quadril , Fraturas Ósseas/cirurgia , Fraturas Ósseas/etiologia
9.
Rev Esp Cir Ortop Traumatol ; 61(3): 193-199, 2017.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28385469

RESUMO

Subsidence is one of the potential complications in femoral stem revision total hip arthroplasty surgery, and can affect stability and osseointegration. A retrospective study was conducted on the outcomes at one year and 5 years (specifically subsidence and clinical relevance) of 40 consecutive femoral total hip arthroplasty revisions, comparing two modular cementless revision stems, Straight vs. Curved, with 20 patients in each group. No mechanical failure was observed, and there was an improvement in functional outcomes. Mean radiological subsidence was 9.9±4.9mm (straight=10.75mm vs. curved=9.03mm), with no statistically significant difference between groups (p=0,076). Fourteen patients (35%) had ≥10mm of subsidence, up to a maximum of 22mm. The subsidence found in this study is similar to published series, with no short-term clinical manifestations, or an increased number of complications or stem loosening in either the Straight or Curved group. No differences in subsidence were observed at one year and 5 years after surgery between the 2 types of stems.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Falha de Prótese/etiologia , Reoperação/instrumentação , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Reoperação/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA