Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38697283

RESUMO

INTRODUCTION AND OBJECTIVES: The multiparametric implantable cardioverter-defibrillator HeartLogic index has proven to be a sensitive and timely predictor of impending heart failure (HF) decompensation. We evaluated the impact of a standardized follow-up protocol implemented by nursing staff and based on remote management of alerts. METHODS: The algorithm was activated in HF patients at 19 Spanish centers. Transmitted data were analyzed remotely, and patients were contacted by telephone if alerts were issued. Clinical actions were implemented remotely or through outpatient visits. The primary endpoint consisted of HF hospitalizations or death. Secondary endpoints were HF outpatient visits. We compared the 12-month periods before and after the adoption of the protocol. RESULTS: We analyzed 392 patients (aged 69±10 years, 76% male, 50% ischemic cardiomyopathy) with implantable cardioverter-defibrillators (20%) or cardiac resynchronization therapy defibrillators (80%). The primary endpoint occurred 151 times in 86 (22%) patients during the 12 months before the adoption of the protocol, and 69 times in 45 (11%) patients (P<.001) during the 12 months after its adoption. The mean number of hospitalizations per patient was 0.39±0.89 pre- and 0.18±0.57 postadoption (P<.001). There were 185 outpatient visits for HF in 96 (24%) patients before adoption and 64 in 48 (12%) patients after adoption (P<.001). The mean number of visits per patient was 0.47±1.11 pre- and 0.16±0.51 postadoption (P<.001). CONCLUSIONS: A standardized follow-up protocol based on remote management of HeartLogic alerts enabled effective remote management of HF patients. After its adoption, we observed a significant reduction in HF hospitalizations and outpatient visits.

3.
Rev Esp Cardiol (Engl Ed) ; 75(9): 709-716, 2022 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34896031

RESUMO

INTRODUCTION AND OBJECTIVES: HeartLogic is a multiparametric algorithm incorporated into implantable cardioverter-defibrillators (ICD). The associated alerts predict impending heart failure (HF) decompensations. Our objective was to analyze the association between alerts and clinical events and to describe the implementation of a protocol for remote management in a multicenter registry. METHODS: We evaluated study phase 1 (the investigators were blinded to the alert state) and phases 2 and 3 (after HeartLogic activation, managed as per local practice and with a standardized protocol, respectively). RESULTS: We included 288 patients from 15 centers. In phase 1, the median observation period was 10 months and there were 73 alerts (0.72 alerts/patient-y), with 8 hospitalizations and 2 emergency room admissions for HF (0.10 events/patient-y). There were no HF hospitalizations outside the alert period. In the active phases, the median follow-up was 16 (95%CI, 15-22) months and there were 277 alerts (0.89 alerts/patient-y); 33 were associated with HF hospitalizations or HF death (n=6), 46 with minor decompensations, and 78 with other events. The unexplained alert rate was 0.39 alerts/patient-y. Outside the alert state, there was only 1 HF hospitalization and 1 minor HF decompensation. Most alerts (82% in phase 2 and 81% in phase 3; P=.861) were remotely managed. The median NT-proBNP value was higher within than outside the alert state (7378 vs 1210 pg/mL; P <.001). CONCLUSIONS: The HeartLogic index was frequently associated with HF-related events and other clinically relevant situations, with a low rate of unexplained events. A standardized protocol allowed alerts to be safely and remotely detected and appropriate action to be taken on them.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Algoritmos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Sistema de Registros
5.
Echocardiography ; 34(6): 876-880, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28370416

RESUMO

INTRODUCTION: Dextro-transposition of the great arteries (d-TGA) patients is at high risk of developing right ventricular dysfunction and tricuspid regurgitation in adulthood. Determining the relation between echocardiographic parameters, N-terminal pro-brain natriuretic peptide (NT-pro-BNP) levels and the New York Heart Association (NYHA) functional class may help determining the best time to operate them. METHODS: Patients with simple d-TGA operated in infancy with an atrial switch procedure (Mustard or Senning operation) were followed up in our Adult Congenital Heart Disease Unit. Analytical, echocardiographic, and clinical parameters were determined to evaluate the correlation between right echocardiographic ventricular function, NT-pro-BNP levels, and NYHA functional class. RESULTS: Twenty-four patients with d-TGA were operated in infancy of whom 17 alive patients had simple d-TGA. Nine patients had NT-pro-BNP levels lower than 200 pg/mL and eight patients were above 200 pg/mL. Patients with lower hemoglobin concentration, higher right ventricular diameter or under diuretic treatment showed significant higher NT-pro-BNP levels (above 200 pg/dL). The Spearman test showed a positive correlation between basal right ventricular diameter and tricuspid regurgitation with pro NT BNP levels (correlation coefficient of .624; P=.017 and .490; P=.046, respectively) and a negative correlation with the right ventricle fractional area change (-.508, P=.045). No correlation was seen between NT-pro-BNP levels and the rest of echocardiographic parameters or the NYHA functional class. CONCLUSION: NT-pro-BNP levels showed a positive correlation with basal right ventricular diameter and tricuspid regurgitation but not with NYHA association functional class in d-TGA patients.


Assuntos
Ecocardiografia/métodos , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Transposição dos Grandes Vasos/sangue , Transposição dos Grandes Vasos/complicações , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Transposição dos Grandes Vasos/diagnóstico por imagem
6.
Int J Endocrinol Metab ; 11(4): e8755, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24719633

RESUMO

INTRODUCTION: Anabolic-androgenic steroids (AAS), a synthetic derivate of testosterone, have become a popular drug among athletes and bodybuilders to enhance muscle mass and improve the athletic performance. Many pathological effects such as hepatic and endocrine dysfunction, behavioural changes and cardiovascular complications have been reported. CASE REPORT: Within these ast ones, we find an increase in left ventricular muscle mass, concentric myocardial hypertrophy, left ventricular diastolic dysfunction, arterial hypertension, prothrombotic effects, changes in the concentration of cholesterol levels, particularly a reduction in HDL cholesterol concentration, myocardial infarctions in relation to endothelial dysfunction, vasospasms or thrombosis and sudden cardiac death. DISCUSSION: We report the case of a 32-year-old patient with a history of arterial hypertension, depressive syndrome and consumption of cocaine, amphetamines and AAS who developed severe left ventricular systolic dysfunction and myocardial hypertrophy with signs of heart failure and peripheral arterial embolism.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA