Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 376
Filtrar
1.
Public Health ; 232: 114-120, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38772199

RESUMO

OBJECTIVE: To set up and evaluate a new surveillance system for severe acute respiratory infection (SARI) in Scotland. STUDY DESIGN: Cross-sectional study and evaluation of surveillance system. METHODS: The SARI case definition comprised patients aged 16 years or over with an acute respiratory illness presentation requiring testing for influenza and SARS-CoV-2 and hospital admission. Data were collected from SARI cases by research nurses in one tertiary teaching hospital using a bespoke data collection tool from November 2021 to May 2022. Descriptive analyses of SARI cases were carried out. The following attributes of the surveillance system were evaluated according to Centers for Disease Control and Prevention (CDC) guidelines: stability, data quality, timeliness, positive predictive value, representativeness, simplicity, acceptability and flexibility. RESULTS: The final surveillance dataset comprised 1163 records, with cases peaking in ISO week 50 (week ending 19/12/2021). The system produced a stable stream of surveillance data, with the proportion of SARI records with sufficient information for effective surveillance increasing from 65.4% during the first month to 87.0% over time. Similarly, the proportion where data collection was completed promptly was low initially, but increased to 50%-65% during later periods. CONCLUSION: SARI surveillance was successfully established in one hospital, but for a national system, additional sentinel hospital sites across Scotland, with flexibility to ensure consistently high data completeness and timeliness are needed. Data collection should be automated where possible, and demands on clinicians minimised. SARI surveillance should be embedded and resourced as part of a national respiratory surveillance strategy.


Assuntos
COVID-19 , Centros de Atenção Terciária , Humanos , Escócia/epidemiologia , Estudos Transversais , Feminino , COVID-19/epidemiologia , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Adolescente , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/diagnóstico , SARS-CoV-2 , Adulto Jovem , Influenza Humana/epidemiologia , Influenza Humana/diagnóstico , Vigilância da População/métodos
2.
Accid Anal Prev ; 159: 106225, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34130056

RESUMO

During the COVID-19 stay-at-home period there were observed increases in both the percentage of cars engaged in extreme speeding, and the percentage of cars traveling below the speed limit. These changes have been attributed to unusually low traffic volume during the stay-at-home period. We develop a novel theoretical account, based on existing empirical research, of perceptual and psychological processes that may account for changes in speeding behavior under low traffic volume conditions. These include impaired ability to accurately perceive and control speed due to change in visual information, decreased salience of certain norms about socially appropriate speeds, lower perceived risk of speeding, and increased boredom leading to risk-taking behaviors. Further, we consider that individual attitude functions may account for the observed split in speeding behavior.


Assuntos
Condução de Veículo , COVID-19 , Acidentes de Trânsito , Humanos , Pandemias , Assunção de Riscos , SARS-CoV-2
3.
Sci Adv ; 5(9): eaax4489, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31579826

RESUMO

Most studies on human immunity to malaria have focused on the roles of immunoglobulin G (IgG), whereas the roles of IgM remain undefined. Analyzing multiple human cohorts to assess the dynamics of malaria-specific IgM during experimentally induced and naturally acquired malaria, we identified IgM activity against blood-stage parasites. We found that merozoite-specific IgM appears rapidly in Plasmodium falciparum infection and is prominent during malaria in children and adults with lifetime exposure, together with IgG. Unexpectedly, IgM persisted for extended periods of time; we found no difference in decay of merozoite-specific IgM over time compared to that of IgG. IgM blocked merozoite invasion of red blood cells in a complement-dependent manner. IgM was also associated with significantly reduced risk of clinical malaria in a longitudinal cohort of children. These findings suggest that merozoite-specific IgM is an important functional and long-lived antibody response targeting blood-stage malaria parasites that contributes to malaria immunity.


Assuntos
Anticorpos Antiprotozoários/imunologia , Interações Hospedeiro-Parasita/imunologia , Imunidade , Imunoglobulina M/imunologia , Malária Falciparum/imunologia , Malária Falciparum/parasitologia , Plasmodium falciparum/imunologia , Adolescente , Adulto , Formação de Anticorpos/imunologia , Especificidade de Anticorpos/imunologia , Antígenos de Protozoários/imunologia , Feminino , Humanos , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180184, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31230576

RESUMO

This paper discusses the properties of electron beams formed in plasma wakefield accelerators through ionization injection. In particular, the potential for generating a beam composed of co-located multi-colour beamlets is demonstrated in the case where the ionization is initiated by the evolving charge field of the drive beam itself. The physics of the processes of ionization and injection are explored through OSIRIS simulations. Experimental evidence showing similar features are presented from the data obtained in the E217 experiment at the FACET facility of the SLAC National Laboratory. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

5.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180173, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31230577

RESUMO

Beam-driven plasma wakefield acceleration (PWFA) has demonstrated significant progress during the past two decades of research. The new Facility for Advanced Accelerator Experimental Tests (FACET) II, currently under construction, will provide 10 GeV electron beams with unprecedented parameters for the next generation of PWFA experiments. In the context of the FACET II facility, we present simulation results on expected betatron radiation and its potential application to diagnose emittance preservation and hosing instability in the upcoming PWFA experiments. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

6.
Rev Sci Instrum ; 90(3): 033503, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927775

RESUMO

A versatile set of methods for analyzing x-ray energy spectra and photon flux has been developed for laser plasma accelerator experiments driven by picosecond lasers. Forward fit provides extrapolated broad energy spectrum measurements, while Ross pair and differential average transmission analysis provide directly measured data points using a particular diagnostic. Combining these methods allows the measurement of x-ray energy spectra with improved confidence. We apply the methods to three diagnostics (filter wheel, stacked image plate spectrometer, and step wedge), each sensitive to a different region of x-ray energies (<40 keV, 35-100 keV, and 60-1000 keV, respectively), to characterize the analysis methods using laser-driven bremsstrahlung x-rays. We then apply the methods to measure three x-ray mechanisms, betatron, inverse Compton scattering, and bremsstrahlung, driven by a laser plasma accelerator. The analysis results in the measurement of x-ray energy spectra ranging from 10 keV to 1 MeV with peak flux greater than 1010 photons/keV/Sr. The combined analysis methods provide a robust tool to accurately measure broadband x-ray sources (keV to MeV) driven by laser plasma acceleration with picosecond, kilojoule-class lasers.

7.
Phys Rev Lett ; 120(12): 124802, 2018 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-29694092

RESUMO

Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.

8.
Sci Rep ; 7(1): 14180, 2017 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-29079817

RESUMO

High gradients of energy gain and high energy efficiency are necessary parameters for compact, cost-efficient and high-energy particle colliders. Plasma Wakefield Accelerators (PWFA) offer both, making them attractive candidates for next-generation colliders. In these devices, a charge-density plasma wave is excited by an ultra-relativistic bunch of charged particles (the drive bunch). The energy in the wave can be extracted by a second bunch (the trailing bunch), as this bunch propagates in the wake of the drive bunch. While a trailing electron bunch was accelerated in a plasma with more than a gigaelectronvolt of energy gain, accelerating a trailing positron bunch in a plasma is much more challenging as the plasma response can be asymmetric for positrons and electrons. We report the demonstration of the energy gain by a distinct trailing positron bunch in a plasma wakefield accelerator, spanning nonlinear to quasi-linear regimes, and unveil the beam loading process underlying the accelerator energy efficiency. A positron bunch is used to drive the plasma wake in the experiment, though the quasi-linear wake structure could as easily be formed by an electron bunch or a laser driver. The results thus mark the first acceleration of a distinct positron bunch in plasma-based particle accelerators.

9.
Phys Rev Lett ; 118(13): 134801, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28409970

RESUMO

We investigate a new regime for betatron x-ray emission that utilizes kilojoule-class picosecond lasers to drive wakes in plasmas. When such laser pulses with intensities of ∼5×10^{18} W/cm^{2} are focused into plasmas with electron densities of ∼1×10^{19} cm^{-3}, they undergo self-modulation and channeling, which accelerates electrons up to 200 MeV energies and causes those electrons to emit x rays. The measured x-ray spectra are fit with a synchrotron spectrum with a critical energy of 10-20 keV, and 2D particle-in-cell simulations were used to model the acceleration and radiation of the electrons in our experimental conditions.

10.
Phys Rev Lett ; 118(6): 064801, 2017 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-28234524

RESUMO

We show the first experimental demonstration that electrons being accelerated in a laser wakefield accelerator operating in the forced or blowout regimes gain significant energy from both the direct laser acceleration (DLA) and the laser wakefield acceleration mechanisms. Supporting full-scale 3D particle-in-cell simulations elucidate the role of the DLA of electrons in a laser wakefield accelerator when ionization injection of electrons is employed. An explanation is given for how electrons can maintain the DLA resonance condition in a laser wakefield accelerator despite the evolving properties of both the drive laser and the electrons. The produced electron beams exhibit characteristic features that are indicative of DLA as an additional acceleration mechanism.

11.
Astron Astrophys ; 6072017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-31844331

RESUMO

We present far-infrared observations of Monoceros R2 (a giant molecular cloud at approximately 830 pc distance, containing several sites of active star formation), as observed at 70 µm, 160 µm, 250 µm, 350 µm, and 500 µm by the Photodetector Array Camera and Spectrometer (PACS) and Spectral and Photometric Imaging Receiver (SPIRE) instruments on the Herschel Space Observatory as part of the Herschel imaging survey of OB young stellar objects (HOBYS) Key programme. The Herschel data are complemented by SCUBA-2 data in the submillimetre range, and WISE and Spitzer data in the mid-infrared. In addition, C18O data from the IRAM 30-m Telescope are presented, and used for kinematic information. Sources were extracted from the maps with getsources, and from the fluxes measured, spectral energy distributions were constructed, allowing measurements of source mass and dust temperature. Of 177 Herschel sources robustly detected in the region (a detection with high signal-to-noise and low axis ratio at multiple wavelengths), including protostars and starless cores, 29 are found in a filamentary hub at the centre of the region (a little over 1% of the observed area). These objects are on average smaller, more massive, and more luminous than those in the surrounding regions (which together suggest that they are at a later stage of evolution), a result that cannot be explained entirely by selection effects. These results suggest a picture in which the hub may have begun star formation at a point significantly earlier than the outer regions, possibly forming as a result of feedback from earlier star formation. Furthermore, the hub may be sustaining its star formation by accreting material from the surrounding filaments.

12.
Epidemiol Infect ; 145(5): 925-941, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28004622

RESUMO

In 2011 the Incidence Assay Critical Path Working Group reviewed the current state of HIV incidence assays and helped to determine a critical path to the introduction of an HIV incidence assay. At that time the Consortium for Evaluation and Performance of HIV Incidence Assays (CEPHIA) was formed to spur progress and raise standards among assay developers, scientists and laboratories involved in HIV incidence measurement and to structure and conduct a direct independent comparative evaluation of the performance of 10 existing HIV incidence assays, to be considered singly and in combinations as recent infection test algorithms. In this paper we report on a new framework for HIV incidence assay evaluation that has emerged from this effort over the past 5 years, which includes a preliminary target product profile for an incidence assay, a consensus around key performance metrics along with analytical tools and deployment of a standardized approach for incidence assay evaluation. The specimen panels for this evaluation have been collected in large volumes, characterized using a novel approach for infection dating rules and assembled into panels designed to assess the impact of important sources of measurement error with incidence assays such as viral subtype, elite host control of viraemia and antiretroviral treatment. We present the specific rationale for several of these innovations, and discuss important resources for assay developers and researchers that have recently become available. Finally, we summarize the key remaining steps on the path to development and implementation of reliable assays for monitoring HIV incidence at a population level.


Assuntos
Métodos Epidemiológicos , Infecções por HIV/epidemiologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/virologia , Recursos em Saúde , Humanos , Incidência
13.
Nat Commun ; 7: 12483, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27527569

RESUMO

The preservation of emittance of the accelerating beam is the next challenge for plasma-based accelerators envisioned for future light sources and colliders. The field structure of a highly nonlinear plasma wake is potentially suitable for this purpose but has not been yet measured. Here we show that the longitudinal variation of the fields in a nonlinear plasma wakefield accelerator cavity produced by a relativistic electron bunch can be mapped using the bunch itself as a probe. We find that, for much of the cavity that is devoid of plasma electrons, the transverse force is constant longitudinally to within ±3% (r.m.s.). Moreover, comparison of experimental data and simulations has resulted in mapping of the longitudinal electric field of the unloaded wake up to 83 GV m(-1) to a similar degree of accuracy. These results bode well for high-gradient, high-efficiency acceleration of electron bunches while preserving their emittance in such a cavity.

14.
Nat Commun ; 7: 11898, 2016 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-27312720

RESUMO

Plasma accelerators driven by particle beams are a very promising future accelerator technology as they can sustain high accelerating fields over long distances with high energy efficiency. They rely on the excitation of a plasma wave in the wake of a drive beam. To generate the plasma, a neutral gas can be field-ionized by the head of the drive beam, in which case the distance of acceleration and energy gain can be strongly limited by head erosion. Here we overcome this limit and demonstrate that electrons in the tail of a drive beam can be accelerated by up to 27 GeV in a high-ionization-potential gas (argon), boosting their initial 20.35 GeV energy by 130%. Particle-in-cell simulations show that the argon plasma is sustaining very high electric fields, of ∼150 GV m(-1), over ∼20 cm. The results open new possibilities for the design of particle beam drivers and plasma sources.

15.
N Engl J Med ; 373(21): 2025-2037, 2015 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-26488565

RESUMO

BACKGROUND: The RTS,S/AS01 vaccine targets the circumsporozoite protein of Plasmodium falciparum and has partial protective efficacy against clinical and severe malaria disease in infants and children. We investigated whether the vaccine efficacy was specific to certain parasite genotypes at the circumsporozoite protein locus. METHODS: We used polymerase chain reaction-based next-generation sequencing of DNA extracted from samples from 4985 participants to survey circumsporozoite protein polymorphisms. We evaluated the effect that polymorphic positions and haplotypic regions within the circumsporozoite protein had on vaccine efficacy against first episodes of clinical malaria within 1 year after vaccination. RESULTS: In the per-protocol group of 4577 RTS,S/AS01-vaccinated participants and 2335 control-vaccinated participants who were 5 to 17 months of age, the 1-year cumulative vaccine efficacy was 50.3% (95% confidence interval [CI], 34.6 to 62.3) against clinical malaria in which parasites matched the vaccine in the entire circumsporozoite protein C-terminal (139 infections), as compared with 33.4% (95% CI, 29.3 to 37.2) against mismatched malaria (1951 infections) (P=0.04 for differential vaccine efficacy). The vaccine efficacy based on the hazard ratio was 62.7% (95% CI, 51.6 to 71.3) against matched infections versus 54.2% (95% CI, 49.9 to 58.1) against mismatched infections (P=0.06). In the group of infants 6 to 12 weeks of age, there was no evidence of differential allele-specific vaccine efficacy. CONCLUSIONS: These results suggest that among children 5 to 17 months of age, the RTS,S vaccine has greater activity against malaria parasites with the matched circumsporozoite protein allele than against mismatched malaria. The overall vaccine efficacy in this age category will depend on the proportion of matched alleles in the local parasite population; in this trial, less than 10% of parasites had matched alleles. (Funded by the National Institutes of Health and others.).


Assuntos
Vacinas Antimaláricas/imunologia , Malária Falciparum/prevenção & controle , Plasmodium falciparum/genética , África , Feminino , Variação Genética , Humanos , Lactente , Malária Falciparum/imunologia , Malária Falciparum/parasitologia , Masculino , Resultado do Tratamento
16.
Phys Rev Lett ; 115(5): 055004, 2015 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-26274427

RESUMO

Ultrarelativistic-energy electron ring structures have been observed from laser-wakefield acceleration experiments in the blowout regime. These electron rings had 170-280 MeV energies with 5%-25% energy spread and ∼10 pC of charge and were observed over a range of plasma densities and compositions. Three-dimensional particle-in-cell simulations show that laser intensity enhancement in the wake leads to sheath splitting and the formation of a hollow toroidal pocket in the electron density around the wake behind the first wake period. If the laser propagates over a distance greater than the ideal dephasing length, some of the dephasing electrons in the second period can become trapped within the pocket and form an ultrarelativistic electron ring that propagates in free space over a meter-scale distance upon exiting the plasma. Such a structure acts as a relativistic potential well, which has applications for accelerating positively charged particles such as positrons.

17.
Nature ; 524(7566): 442-5, 2015 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-26310764

RESUMO

Electrical breakdown sets a limit on the kinetic energy that particles in a conventional radio-frequency accelerator can reach. New accelerator concepts must be developed to achieve higher energies and to make future particle colliders more compact and affordable. The plasma wakefield accelerator (PWFA) embodies one such concept, in which the electric field of a plasma wake excited by a bunch of charged particles (such as electrons) is used to accelerate a trailing bunch of particles. To apply plasma acceleration to electron-positron colliders, it is imperative that both the electrons and their antimatter counterpart, the positrons, are efficiently accelerated at high fields using plasmas. Although substantial progress has recently been reported on high-field, high-efficiency acceleration of electrons in a PWFA powered by an electron bunch, such an electron-driven wake is unsuitable for the acceleration and focusing of a positron bunch. Here we demonstrate a new regime of PWFAs where particles in the front of a single positron bunch transfer their energy to a substantial number of those in the rear of the same bunch by exciting a wakefield in the plasma. In the process, the accelerating field is altered--'self-loaded'--so that about a billion positrons gain five gigaelectronvolts of energy with a narrow energy spread over a distance of just 1.3 metres. They extract about 30 per cent of the wake's energy and form a spectrally distinct bunch with a root-mean-square energy spread as low as 1.8 per cent. This ability to transfer energy efficiently from the front to the rear within a single positron bunch makes the PWFA scheme very attractive as an energy booster to an electron-positron collider.

18.
Environ Sci Technol ; 49(9): 5484-92, 2015 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-25811739

RESUMO

In many environmental scenarios, the fate and impact of polymer nanocomposites (PNCs) that contain carbon nanotubes (CNT/PNCs) will be influenced by their interactions with microorganisms, with implications for antimicrobial properties and the long-term persistence of PNCs. Using oxidized single-wall (O-SWCNTs) and multi-wall CNTs (O-MWCNTs), we explored the influence that CNT loading (mass fraction≤0.1%-10%) and type have on the initial interactions of Pseudomonas aeruginosa with O-CNT/poly(vinyl alcohol) (PVOH) nanocomposites containing well-dispersed O-CNTs. LIVE/DEAD staining revealed that, despite oxidation, the inclusion of O-SWCNTs or O-MWCNTs caused PNC surfaces to exhibit antimicrobial properties. The fraction of living cells deposited on both O-SWCNT and O-MWCNT/PNC surfaces decreased exponentially with increasing CNT loading, with O-SWCNTs being approximately three times more cytotoxic on a % w/w basis. Although not every contact event between attached microorganisms and CNTs led to cell death, the cytotoxicity of the CNT/PNC surfaces scaled with the total contact area that existed between the microorganisms and CNTs. However, because the antimicrobial properties of CNT/PNC surfaces require direct CNT-microbe contact, dead cells were able to shield living cells from the cytotoxic effects of CNTs, allowing biofilm formation to occur on CNT/PNCs exposed to Pseudomonas aeruginosa for longer time periods.


Assuntos
Nanotubos de Carbono/microbiologia , Pseudomonas aeruginosa/fisiologia , Anti-Infecciosos/química , Biofilmes , Meio Ambiente , Nanocompostos , Oxirredução
19.
Int J STD AIDS ; 26(7): 504-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25080291

RESUMO

Previous studies have highlighted disparities in care and outcomes in HIV-positive prisoners compared to HIV-positive individuals in the population. We audited clinical outcomes of HIV-positive prisoners accessing care in 2011. Public Health England were notified of 161 prisoners with HIV in the time period studied. Audit proformas were sent to clinics reporting prisoners to the genitourinary medicine clinic activity dataset in 2011. Thirty-two clinics responded. Data for 151 HIV-positive prisoners were reported by 12 clinics, with the other clinics not reporting any prisoners. Outcomes were compared to a previous audit, British HIV Association (BHIVA) and the National AIDS Trust guidelines. Initial CD4 counts were available for 101 patients, of which 42/101 had CD4 <350 cells/mm(3). At reception, viral load data were available for 95 patients, of which 74 were on antiretroviral therapy. Of these, 50/74 (68%) had VL <40 copies/ml. Fifty-one per cent of those on highly active antiretroviral therapy were seen in a specialist clinic less than four weeks after reception. Urgency of referral to a specialist HIV clinic was not related to CD4 or viral load. Twenty-two per cent had hepatitis C co-infection. Clinical outcomes have improved since the last audit but further opportunities exist to optimise care in prisons.


Assuntos
Antirretrovirais/uso terapêutico , Infecções por HIV/tratamento farmacológico , Prisioneiros , Prisões , Adulto , Terapia Antirretroviral de Alta Atividade , Contagem de Linfócito CD4 , Inglaterra , Feminino , HIV-1 , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Resultado do Tratamento
20.
Chem Commun (Camb) ; 51(1): 187-90, 2015 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-25388621

RESUMO

A simple method is presented for exfoliating and suspending hexagonal boron nitride using a co-solvent approach. A 60 w/w% concentration of tert-butanol in water is very effective at exfoliating boron nitride especially when compared to the individual components alone as indicated by UV-vis and transmission electron microscopy. Molecular weight and surface tension are found to play inverse roles in the exfoliation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA