Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Front Cardiovasc Med ; 9: 997961, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312248

RESUMO

Introduction: In the last two decades, a more aggressive approach has been encouraged to treat patients with acute type A aortic dissection (ATAAD), extending the repair to the aortic arch and proximal descending thoracic aorta with the frozen elephant trunk (FET) implantation. Here, we report our single-centre experience with the FET technique for the systematic treatment of emergency type A aortic dissection. Materials and methods: Between December 2017 and January 2022, 69 consecutive patients were admitted with ATAAD; of those, 66 patients (62.9 ± 10.2 years of age, 81.8% men) underwent emergency hybrid aortic arch and FET repair with the multibranched Thoraflex hybrid graft and were enrolled in the study. Primary endpoints were 30 days- and in-hospital mortality. Secondary endpoints were postoperative morbidity and follow-up survival. To better clarify the impact of age on surgical outcomes, we have divided the study population into two groups: group A for patients <70 years of age (47 patients), and group B for patients ≥70 years (19 patients). Time-to-event analysis has been conducted using the Log-rank test and is displayed with Kaplan-Meier curves. A multiple Cox proportional Hazard model was developed to identify predictors of long-term survival with a stepwise backward/forward selection process. Results: 30-days- and in-hospital mortality were 10.6 and 13.6%, respectively. Stroke occurred in three (4.5%) patients. Two (3.0%) patients experienced spinal cord ischemia. We did not find any statistically significant difference between the two groups in terms of main post-operative outcomes. The multivariable Cox proportional hazard model showed left ventricular ejection fraction (HR: 0.83, 95% CI: 0.79-0.92, p < 0.01), peripheral vascular disease (HR: 15.8, 95% CI: 3.9-62.9, p < 0.01), coronary malperfusion (HR: 0.10, 95% CI: 0.01-0.77, p =0.03), lower limbs malperfusion (HR: 5.1, 95% CI: 1.10-23.4, p = 0.04), and cardiopulmonary bypass time (HR: 1.02, 95% CI: 1-1.04, p = 0.01) as independent predictors of long term mortality. Conclusions: Frozen elephant trunk repair to treat emergency type A aortic dissection appears to be associated with good early and mid-term clinical outcomes even in the elderly.

2.
Cardiovasc Diagn Ther ; 12(4): 516-520, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36033221

RESUMO

The frozen elephant trunk (FET) technique is an increasingly common procedure to treat complex extensive aortic disease both in elective and emergency setting. In a contemporary era, several prostheses are available to be used by surgeons performing such procedures, merging the advantages of endovascular and conventional surgery and preparing a more useful landing zone for second-stage downstream endovascular or open repair. Thoraflex hybrid (Terumo Aortic, Scotland) is a largely used hybrid vascular device merging a conventional surgical vascular graft made of gelatin-sealed woven polyester graft with a nitinol self-expanding stent graft. Since its release in 2012, this prosthesis has gained a large consensus, mainly for the plexus version, which allows for single reimplantation of the epiaortic vessels. In the last few years, new devices have come out to offer new specific weapons to be used by the surgical team in different clinical scenarios. In this context, the need of making the supra-aortic vessel debranching easier and more functional to our surgical technique has pushed our demand for a customization of a conventional Thoraflex hybrid. Here we report a modification to its standard design, the concept beyond the "Custom device" and its potential advantages with regards to our peculiar implantation technique and intraoperative cerebral perfusion during circulatory arrest time.

4.
Thorac Cardiovasc Surg ; 70(6): 458-466, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35817063

RESUMO

OBJECTIVES: Cardiac support systems are being used increasingly more due to the growing prevalence of heart failure and cardiogenic shock. Reducing cardiac afterload, intracardiac pressure, and flow support are important factors. Extracorporeal membrane oxygenation (ECMO) and intracardiac microaxial pump systems (Impella) as non-permanent MCS (mechanical circulatory support) are being used increasingly. METHODS: We reviewed the recent literature and developed an international European registry for non-permanent MCS. RESULTS: Life-threatening conditions that are observed preoperatively often include reduced left ventricular function, systemic hypoperfusion, myocardial infarction, acute and chronic heart failure, myocarditis, and valve vitia. Postoperative complications that are commonly observed include severe systemic inflammatory response, ischemia-reperfusion injury, trauma-related disorders, which ultimately may lead to low cardiac output (CO) syndrome and organ dysfunctions, which necessitates a prolonged ICU stay. Choosing the appropriate device for support is critical. The management strategies and complications differ by system. The "heart-team" approach is inevitably needed.However despite previous efforts to elucidate these topics, it remains largely unclear which patients benefit from certain systems, when is the right time to initiate (MCS), which support system is appropriate, what is the optimal level and type of support, which therapeutic additive and supportive strategies should be considered and ultimately, what are the future prospects and therapeutic developments. CONCLUSION: The European cardiac surgical register ImCarS has been established as an IIT with the overall aim to evaluate data received from the daily clinical practice in cardiac surgery. Interested colleagues are cordially invited to join the register. CLINICAL REGISTRATION NUMBER: DRKS00024560. POSITIVE ETHICS VOTE: AZ 246/20 Faculty of Medicine, Justus-Liebig-University-Gießen.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
5.
J Card Surg ; 37(1): 107-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34662451

RESUMO

BACKGROUND AND AIM OF THE STUDY: To report early clinical outcomes of the frozen elephant trunk (FET) technique for the treatment of complex aortic diseases after transition from conventional elephant trunk. METHODS: A single-center, retrospective study of patients who underwent hybrid aortic arch and FET repair for aortic arch and/or proximal descending aortic aneurysms, acute and chronic Stanford type A aortic dissection with arch and/or proximal descending involvement, Stanford type B acute and chronic aortic dissections with retrograde aortic arch involvement. RESULTS: Between December 2017 and May 2020, 70 consecutive patients (62.7 ± 10.6 years, 59 male) were treated: 41 (58.6%) for emergent conditions and 29 (41.4%) for elective. Technical success was 100%. In-hospital mortality was 14.2% (n = 12, 17.1% emergent vs. 10.3% elective, P = NS); 2 (2.9%) major strokes; 1 (1.4%) spinal cord injury. Mean follow-up was 12.5 months (interquartile range, 3.7-22.3). Overall survival at 3, 6, 12, and 24 months was 90% (95% confidence interval [CI], 83.2-97.3), 85.6% (95% CI, 77.7-94.3), 79.1% (95% CI, 69.9-89.5), 75.6% (95% CI, 65.8-86.9) and 73.5% (95% CI, 63.3-85.3). There were no aortic re-interventions and no distal stent graft-induced new entry (dSINE); 5 patients with residual type B dissection underwent TEVAR completion. CONCLUSIONS: In a real-world setting, FET with Thoraflex Hybrid demonstrated feasibility and good clinical outcomes, even in emergent setting. Our implant technique optimize cerebral perfusion reporting good results in terms of neurological complications. Techniques to perfect the procedure and to reduce remaining risks, and consensus on considerations such as standardized cerebral protection need to be reported.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos , Masculino , Estudos Retrospectivos
6.
Medicina (Kaunas) ; 57(9)2021 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-34577818

RESUMO

Acute type A aortic dissection (ATAAD) is an indisputable emergency with very poor outcomes without surgical treatment. Although the aortic arch is often involved in the aortic dissection, its optimal management during surgical therapy remains uncertain. A conservative tear-oriented approach has traditionally been adopted, limiting the procedure to the ascending aorta (or hemiarch) replacement. However, dilation of the residual dissected aorta and subsequent rupture may occur, requiring further intervention in the future. In the last two decades, the frozen elephant trunk (FET) technique has become a valid and attractive option to treat aortic disease when the arch and the thoracic aorta are involved, both in elective and in emergency settings. Here, we report a review of the contemporary literature regarding the short- and long-term outcomes of the FET technique in ATAAD repair.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos
7.
Clin Case Rep ; 9(9): e04688, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34484752

RESUMO

Difficult diagnosis is due to rarity of the case. TT or TE echocardiography is sufficient to make a correct diagnosis. The risk of embolism or coronary ostia occlusion should guide the decision for surgery.

8.
JACC Case Rep ; 3(6): 884-887, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34317647

RESUMO

We report a unique case of a Starr-Edwards prosthesis (model 6310, cloth covered) implanted in the mitral position by Christian Barnard that was successfully explanted and replaced after 50 years, the longest period free from valve dysfunction ever reported. Reoperation also included replacement of the native aortic valve combined with tricuspid valve annuloplasty. (Level of Difficulty: Beginner.).

9.
Gen Thorac Cardiovasc Surg ; 69(5): 877-881, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33400196

RESUMO

Short-term mechanical circulatory support (MCS) devices are designed to provide hemodynamic support for a wide range of clinical conditions such as high-risk cardiac surgery or interventional procedures, post-cardiotomy cardiogenic shock, acute decompensated heart failure. Electrical storm (defined as three or more sustained episodes of ventricular fibrillation-VF- in a 24-h period) is a rare but critical complication following revascularization in patients with ischemic heart disease and it is associated with a very high mortality (80-90%) both during the incident alone and during further observation. Here we report the case of a 38-year-old patient affected by coronary artery disease with moderate to severe left ventricular systolic dysfunction (EF 30-35%) who underwent emergency coronary artery bypass grafting (CABG) complicated by electrical storm and severe haemodynamic instability, successfully managed with a novel approach of biventricular mechanical circulatory support with extracorporeal life support (ECLS) in first instance, subsequently switched to Impella CP and ProtekDuo.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Adulto , Humanos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
10.
J Card Surg ; 36(1): 371-373, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33225461

RESUMO

Reimplantation of the supra-aortic vessels can be challenging with Thoraflex Hybrid. A device modification made the vessel lengths more appropriate and the position of the neo-vessels in the chest avoided malpositioning and kinking and facilitated sternum closure; this may improve operating times as well as allowing complete and continuous cerebral trivascular perfusion and corrects positioning of the intrathoracic vessels.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Anastomose Cirúrgica , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos
11.
Aorta (Stamford) ; 8(4): 111-115, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33307592

RESUMO

Type A aortic dissection, according to Stanford classification, is a surgical emergency with high morbidity and carries 56% of in-hospital mortality when surgical intervention is not performed. The surgical mortality at 30 days is 10 to 20%. The therapeutic goals are to replace the diseased ascending aorta and to treat or to monitor the distal aortic patent false lumen. When the dissection involves the aortic root and the architecture of aortic valve is normal, the surgical techniques used could be multiple: reinforce the aortic root and spare the native aortic valve or replace the aortic valve and the aortic root. The Florida sleeve technique has been developed to treat the aortic aneurysm, sparing the aortic valve in patients with connective tissue disease. Some case reports have described the use of this technique to treat an acute aortic dissection. In the following case, we present a single stage repair of the ascending aorta, aortic arch, and proximal intrathoracic aorta in a patient with Type A aortic dissection through the contemporaneous use of two techniques: Florida sleeve and Vascutek "Thoraflex" hybrid prosthesis. The use of these two techniques allows the repair/replacement of the proximal intrathoracic aorta, the sparing of the native aortic valve, the employment of a hybrid prosthesis to replace the supraortic vessels, and the creation of a descending aortic landing zone for later, distal intervention.

12.
J Card Surg ; 35(11): 3157-3159, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32720389

RESUMO

BACKGROUND: Displacement of Impella 5.0 secondary to patient movement or transportation is a well-known complication. Typically, repositioning of an Impella across the aortic valve is attempted over a guidewire. We present the first case, to our knowledge, of repositioning a dislodged Impella 5.0 without a guidewire under transesophageal echocardiography (TEE) guidance, by inducing rapid ventricular pacing to cross the aortic valve. CASE PRESENTATION: A 70-year-old man with low left ventricular ejection fraction underwent off-pump coronary artery bypass grafting. On 2nd postoperative day a low cardiac output state developed with increasing lactate levels and consequently the patient was taken to the cardiac catheterization laboratory for insertion of an Impella 5.0. Suddenly the Impella system failed with a rapid hemodynamic deterioration and it was successfully bedside repositioned inducing rapid ventricular pacing. CONCLUSIONS: In case of accidental Impella dislodgement and fast deterioration of the patient's hemodynamic status, rapid pacing may be an option to "open" the aortic valve thus aiding quick replacement of Impella 5.0 through the aortic valve into the left ventricle under TEE guidance.


Assuntos
Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial/métodos , Coração Auxiliar/efeitos adversos , Falha de Prótese , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Ponte de Artéria Coronária sem Circulação Extracorpórea , Ecocardiografia Transesofagiana , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Masculino , Reoperação
13.
Pharmacogenomics J ; 20(3): 451-461, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31801992

RESUMO

We assessed the predictive accuracy of the Warfarin Pharmacogenetics Consortium (IWPC) algorithm in a prospective cohort of 376 high-risk elderly patients (≥65 years) who required new treatment with warfarin for either medical (non valvular atrial fibrillation) or surgical conditions (heart valve replacement), had ≥1 comorbid conditions, and regularly used ≥2 other drugs. Follow-up visits were performed according to clinical practice and lasted for a maximum of 1 year. Two hundred and eighty-three (75%) patients achieved a stable maintenance dose. Warfarin maintenance doses were low on average (median 20.3 mg/week, interquartile range, 14.1-27.7 mg/week) and were substantially overestimated by the IWPC algorithm. Overall the percentage of patients whose predicted dose of warfarin was within 20% of the actual stable dose was equal to 37.5%, (95% CI 32.0-43.3%). IWPC algorithm explained only 31% of the actual warfarin dose variability. Modifications of the IWPC algorithm are needed in high-risk elderly people.


Assuntos
Algoritmos , Anticoagulantes/administração & dosagem , Internacionalidade , Farmacogenética/normas , Varfarina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/genética , Estudos de Coortes , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Doenças das Valvas Cardíacas/tratamento farmacológico , Doenças das Valvas Cardíacas/genética , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Varfarina/efeitos adversos
14.
JACC Case Rep ; 1(2): 116-117, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34316763

RESUMO

The authors report the case of an 87-year-old man undergoing transcatheter aortic valve replacement via transfemoral approach who developed a life-threatening complication, i.e., fistulization between the aortic root and the left atrium, which was successfully treated by surgery. At 6-month follow-up, the clinical course was uneventful. (Level of Difficulty: Beginner.).

15.
Eur Heart J Acute Cardiovasc Care ; 6(7): 666-669, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26566773

RESUMO

Spontaneous coronary artery rupture is a rare disorder that may develop early into a sudden death due to the abrupt evolution of the associated cardiac tamponade. In some cases the rupture is contained and a false aneurysm develops with slower evolution of clinical signs. The correct diagnosis of spontaneous coronary artery rupture deserves a high level of suspicion; frequently it may be missed because the time window of its evolution seems to be very short or signs of acute coronary syndrome sometimes can prevail, leading to delays in diagnosis or to misdiagnosis. We report the case of a patient presenting a giant pseudoaneurysm of the right coronary artery due to spontaneous coronary artery rupture without any underlying disease. Moreover we present a review of the few cases in the literature, offering a pathophysiological hypothesis linking the site of rupture and clinical presentation.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Falso Aneurisma/complicações , Tamponamento Cardíaco/complicações , Aneurisma Coronário/complicações , Vasos Coronários/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/cirurgia , Adulto , Falso Aneurisma/diagnóstico , Procedimentos Cirúrgicos Cardíacos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Angiografia por Tomografia Computadorizada , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/cirurgia , Angiografia Coronária , Ecocardiografia Transesofagiana , Eletrocardiografia , Humanos , Masculino , Ruptura Espontânea
16.
Monaldi Arch Chest Dis ; 76(1): 47-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21751738

RESUMO

We report a case of type A intramural aortic hematoma (IMH) occurred in a 78 years old female. The clinical scenario (medical history of hypertension, severe substernal chest pain, early diastolic decrescendo murmur as for aortic insufficiency), the laboratory results (no significant troponin level), ECG and transthoracic echocardiography findings (no signs of myocardial ischemia) shifted the initial diagnostic suspicion from acute coronary syndrome to the acute aortic syndrome (AAS) and triggered further imaging tests. Computed tomography revealed an aneurismatic dilatation with thickening of the wall of the ascending aorta without intimal flap. No particular "warning message" for evidence of AAS was sent to the clinician on call. Subsequently, due to the persisting high clinical suspicion transesophageal echocardiography (TEE) was performed. TEE confirmed the aneurysm of the ascending aorta and highlighted an extended and marked aortic wall thickness, consisting with the diagnosis of type A IMH. Patient underwent urgent cardiac surgery that confirmed the diagnosis.


Assuntos
Doenças da Aorta/diagnóstico , Hematoma/diagnóstico , Idoso , Doenças da Aorta/cirurgia , Ecocardiografia , Ecocardiografia Transesofagiana , Eletrocardiografia , Feminino , Hematoma/cirurgia , Humanos
19.
Cardiovasc Surg ; 10(4): 333-8, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12359403

RESUMO

BACKGROUND: the theoretical advantages of mini-invasive cardiac surgery are shorter hospitalisation, better surgical results and costs reduction. In November 1997 we started a non-coronary mini-invasive surgery program using a partial upper median sternotomy. This study has been conceived to retrospectively compare two groups of patients who underwent isolate aortic valve replacement using the conventional and the mini-invasive technique. MATERIAL AND METHODS: in Group A 100 patients (mean age 62+/-12 years; 58 male) underwent isolated aortic valve replacement through a partial upper median sternotomy. Group B was composed by the last 100 patients (mean age 63+/-8 years; 56 male) who underwent the same operation through a conventional median sternotomy. For both groups we recorded the ECC and ischaemic times, postoperative intubation time, total postoperative bleeding, intensive care unit length of stay and total hospitalisation time. Major and minor complications were reported. RESULTS: operating times, were significantly longer in Group A (p<0.001). Mechanical ventilation time, ICU and total hospital stay, and total postoperative bleeding showed no significant difference. Adjunctive statistical evidenced the absence of learning curve. Mortality and other complications failed to reveal any significant difference between the two groups. CONCLUSIONS: in our experience, partial upper median sternotomy does not increase surgical risks but failed to demonstrate clear advantages. Apart for an increase in operating times, the surgical results are similar to those of a conventional median sternotomy with only improvement in the aesthetical aspect. In our opinion, this supports the conviction that this approach can be proposed to selected patients, to obtain a better cosmethical result for the same given risk.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Esterno/cirurgia , Idoso , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Período Intraoperatório , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA