RESUMO
One of the main issues in the fluorescent lamp recycling sector is the mercury contamination of output fractions and occupational exposure associated with recycling operations. The aim of this study is to carry out effective mercury mass balance determinations and improve mercury recovery by finding the optimal levels for the recycling process parameters. These optimizations will allow upstream mercury emissions to be reduced, which will help to avoid mercury exposure among WEEE recycling workers. Firstly, the distribution of mercury was assessed in new and spent lamps. For new fluorescent tubes, the mean percentage of mercury in the solid phase is lower in new fluorescent tubes (19.5% with 5.5% in glass, 9.7% in end caps and 4.3% in luminescent powder) than in spent tubes (33.3% with 8.3% in glass, 12.9% in end caps and 12.1% in luminescent powder). The parametric study also shows that the finer the grains of glass, the higher the concentration of mercury (1.2⯵g Hg/g for glass size particle >1000⯵m and 152.0⯵g Hg/g for glass size particle <100⯵m); the crushing time required for the optimal removal of mercury from spent tubes is 24â¯h; on average 71% of the mercury is desorbed at a temperature of 400⯰C. The effects of air flow rate, rotation speed and number of balls could not be determined due to wide variations in the results. It is recommended that recycling companies employ processes combining as heating and mixing techniques for the recovery of mercury from lamps in order to both (i) remove as much of the mercury as possible in vapor form and (ii) avoid adsorption of the mercury at new sites created during the crushing process.