Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Atherosclerosis ; : 117549, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38679562

RESUMO

BACKGROUND AND AIMS: This study investigated the additional prognostic value of epicardial adipose tissue (EAT) volume for major adverse cardiovascular events (MACE) in patients undergoing stress cardiac magnetic resonance (CMR) imaging. METHODS: 730 consecutive patients [mean age: 63 ± 10 years; 616 men] who underwent stress CMR for known or suspected coronary artery disease were randomly divided into derivation (n = 365) and validation (n = 365) cohorts. MACE was defined as non-fatal myocardial infarction and cardiac deaths. A deep learning algorithm was developed and trained to quantify EAT volume from CMR. EAT volume was adjusted for height (EAT volume index). A composite CMR-based risk score by Cox analysis of the risk of MACE was created. RESULTS: In the derivation cohort, 32 patients (8.7 %) developed MACE during a follow-up of 2103 days. Left ventricular ejection fraction (LVEF) < 35 % (HR 4.407 [95 % CI 1.903-10.202]; p<0.001), stress perfusion defect (HR 3.550 [95 % CI 1.765-7.138]; p<0.001), late gadolinium enhancement (LGE) (HR 4.428 [95%CI 1.822-10.759]; p = 0.001) and EAT volume index (HR 1.082 [95 % CI 1.045-1.120]; p<0.001) were independent predictors of MACE. In a multivariate Cox regression analysis, adding EAT volume index to a composite risk score including LVEF, stress perfusion defect and LGE provided additional value in MACE prediction, with a net reclassification improvement of 0.683 (95%CI, 0.336-1.03; p<0.001). The combined evaluation of risk score and EAT volume index showed a higher Harrel C statistic as compared to risk score (0.85 vs. 0.76; p<0.001) and EAT volume index alone (0.85 vs.0.74; p<0.001). These findings were confirmed in the validation cohort. CONCLUSIONS: In patients with clinically indicated stress CMR, fully automated EAT volume measured by deep learning can provide additional prognostic information on top of standard clinical and imaging parameters.

2.
Cardiovasc Diabetol ; 23(1): 107, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553774

RESUMO

BACKGROUND: Diabetes-induced trained immunity contributes to the development of atherosclerosis and its complications. This study aimed to investigate in humans whether epigenetic signals involved in immune cell activation and inflammation are initiated in hematopoietic stem/progenitor cells (HSPCs) and transferred to differentiated progeny. METHODS AND RESULTS: High glucose (HG)-exposure of cord blood (CB)-derived HSPCs induced a senescent-associated secretory phenotype (SASP) characterized by cell proliferation lowering, ROS production, telomere shortening, up-regulation of p21 and p27genes, upregulation of NFkB-p65 transcription factor and increased secretion of the inflammatory cytokines TNFα and IL6. Chromatin immunoprecipitation assay (ChIP) of p65 promoter revealed that H3K4me1 histone mark accumulation and methyltransferase SetD7 recruitment, along with the reduction of repressive H3K9me3 histone modification, were involved in NFkB-p65 upregulation of HG-HSPCs, as confirmed by increased RNA polymerase II engagement at gene level. The differentiation of HG-HSPCs into myeloid cells generated highly responsive monocytes, mainly composed of intermediate subsets (CD14hiCD16+), that like the cells from which they derive, were characterized by SASP features and similar epigenetic patterns at the p65 promoter. The clinical relevance of our findings was confirmed in sternal BM-derived HSPCs of T2DM patients. In line with our in vitro model, T2DM HSPCs were characterized by SASP profile and SETD7 upregulation. Additionally, they generated, after myeloid differentiation, senescent monocytes mainly composed of proinflammatory intermediates (CD14hiCD16+) characterized by H3K4me1 accumulation at NFkB-p65 promoter. CONCLUSIONS: Hyperglycemia induces marked chromatin modifications in HSPCs, which, once transmitted to the cell progeny, contributes to persistent and pathogenic changes in immune cell function and composition.


Assuntos
Diabetes Mellitus Tipo 2 , Imunidade Treinada , Humanos , Fenótipo Secretor Associado à Senescência , Células-Tronco Hematopoéticas/metabolismo , Antígenos CD34/metabolismo , Epigênese Genética , Diabetes Mellitus Tipo 2/metabolismo , Histona-Lisina N-Metiltransferase/genética , Histona-Lisina N-Metiltransferase/metabolismo
3.
Comput Biol Med ; 171: 108123, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38354498

RESUMO

Aortic valve disease is often treated with bioprosthetic valves. An alternative treatment is aortic valve neocuspidization which is a relatively new reparative procedure whereby the three aortic cusps are replaced with patient pericardium or bovine tissues. Recent research indicates that aortic blood flow is disturbed, and turbulence effects have yet to be evaluated in either bioprosthetic or aortic valve neocuspidization valve types in patient-specific settings. The aim of this study is to better understand turbulence production in the aorta and evaluate its effects on laminar and turbulent wall shear stress. Four patients with aortic valve disease were treated with either bioprosthetic valves (n=2) or aortic valve neocuspidization valvular repair (n=2). Aortic geometries were segmented from magnetic resonance images (MRI), and 4D flow MRI was used to derive physiological inlet and outlet boundary conditions. Pulsatile large-eddy simulations were performed to capture the full range of laminar, transitional and turbulence characteristics in the aorta. Turbulence was produced in all aortas with highest levels occurring during systolic deceleration. In the ascending aorta, turbulence production is attributed to a combination of valvular skew, valvular eccentricity, and ascending aortic dilation. In the proximal descending thoracic aorta, turbulence production is dependent on the type of arch-descending aorta connection (e.g., a narrowing or sharp bend) which induces flow separation. Laminar and turbulent wall shear stresses are of similar magnitude throughout late systolic deceleration and diastole, although turbulent wall shear stress magnitudes exceed laminar wall shear stresses between 27.3% and 61.1% of the cardiac cycle. This emphasises the significance of including turbulent wall shear stress to improve our comprehension of progressive arterial wall diseases. The findings of this study recommend that aortic valve treatments should prioritise minimising valvular eccentricity and skew in order to mitigate turbulence generation.


Assuntos
Valvopatia Aórtica , Valva Aórtica , Humanos , Animais , Bovinos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo/fisiologia , Hemodinâmica/fisiologia , Aorta , Estresse Mecânico
4.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37656941

RESUMO

OBJECTIVES: Aortic valve neocuspidalization aims to replace the 3 aortic cusps with autologous pericardium pre-treated with glutaraldehyde, and it is a surgical alternative to the classical aortic valve replacement (AVR). Image-based patient-specific computational fluid dynamics allows the derivation of shear stress on the aortic wall [wall shear stress (WSS)]. Previous studies support a potential link between increased WSS and histological alterations of the aortic wall. The aim of this study is to compare the WSS of the ascending aorta in patients undergoing aortic valve neocuspidalization versus AVR with biological prostheses. METHODS: This is a prospective nonrandomized clinical trial. Each patient underwent a 4D-flow cardiac magnetic resonance scan after surgery, which informed patient-specific computational fluid dynamics models to evaluate WSS at the ascending aortic wall. The adjusted variables were calculated by summing the residuals obtained from a multivariate linear model (with ejection fraction and left ventricle outflow tract-aorta angle as covariates) to the mean of the variables. RESULTS: Ten patients treated with aortic valve neocuspidalization were enrolled and compared with 10 AVR patients. The aortic valve neocuspidalization group showed a significantly lower WSS in the outer curvature segments of the proximal and distal ascending aorta as compared to AVR patients (P = 0.0179 and 0.0412, respectively). WSS levels remained significantly lower along the outer curvature of the proximal aorta in the aortic valve neocuspidalization population, even after adjusting the WSS for the ejection fraction and the left ventricle outflow tract-aorta angle [2.44 Pa (2.17-3.01) vs 1.94 Pa (1.72-2.01), P = 0.02]. CONCLUSIONS: Aortic valve neocuspidalization hemodynamical features are potentially associated with a lower WSS in the ascending aorta as compared to commercially available bioprosthetic valves.


Assuntos
Aorta , Valva Aórtica , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Aorta/diagnóstico por imagem , Aorta/cirurgia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Hemodinâmica , Estresse Mecânico , Velocidade do Fluxo Sanguíneo
5.
Braz J Cardiovasc Surg ; 37(4): 595-598, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35976212

RESUMO

Iatrogenic acute aortic dissections during percutaneous coronary interventions are an extremely rare but potentially life-threatening complication, occurring in less than 0.02% of transcatheter procedures. We report three patients with different characteristics suffering from iatrogenic aortic dissection during percutaneous coronary intervention successfully treated with an emergency open-heart surgery. A conservative strategy should be pursuit only in small, localized lesions.


Assuntos
Dissecção Aórtica , Intervenção Coronária Percutânea , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Vasos Coronários/cirurgia , Humanos , Doença Iatrogênica , Intervenção Coronária Percutânea/efeitos adversos
6.
Innovations (Phila) ; 17(4): 310-316, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35997682

RESUMO

Objective: Endoscopic vessel harvest (EVH) is evolving as the standard of care for coronary artery bypass grafting. However, the increase in upfront equipment-related costs has resulted in reluctance of uptake globally. We investigated the costs involving a non-sealed technique for EVH versus open vessel harvesting techniques (OVH) for both the greater saphenous vein and radial artery with a 6-month follow-up. Methods: From September 2016 to December 2018, 226 patients underwent OVH while 251 patients underwent EVH using a reusable non-sealed system and a single-use radiofrequency sealing system. Cumulative costs for OVH versus EVH were calculated as a summation of total operative and in-hospital stay costs. Costs related to harvest site complication management were also analyzed for up to 6 months. Results: Total operative costs were greater in the EVH group (Can$2,283.70 [Can$1,377.60 to $4,183.50] vs Can$1,742.40 [Can$998.50 to $3,628.10], P < 0.001). Total length of stay was significantly shorter for the EVH group (5.9 [4 to 43] days vs 6.8 [4 to 55] days, P = 0.018). Cumulative costs were comparable at the end of the hospitalization period (EVH, Can$6,534.70 [Can$2,076.50 to $33,087.70] vs OVH, Can$6,112.50 [Can$3,322.30 to $45,503.50], P = 0.06). After discharge, harvest site-related complications occurred more frequently in the OVH group (27% vs 4.4%, P < 0.001), resulting in increased use of antibiotics (2.2% vs 0.8%, P = 0.02) as well as more frequent requirement for home nursing assistance in the OVH group (5.7% vs 0.8%, P = 0.002) at 6 months of follow-up. Conclusions: Cumulative costs did not show a statistical difference between OVH and EVH, with higher intraoperative costs for EVH being offset by higher harvest site management costs in the OVH group.


Assuntos
Ponte de Artéria Coronária , Coleta de Tecidos e Órgãos , Custos e Análise de Custo , Endoscopia/métodos , Humanos , Veia Safena/transplante
7.
Rev. bras. cir. cardiovasc ; 37(4): 595-598, Jul.-Aug. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1394733

RESUMO

ABSTRACT Iatrogenic acute aortic dissections during percutaneous coronary interventions are an extremely rare but potentially life-threatening complication, occurring in less than 0.02% of transcatheter procedures. We report three patients with different characteristics suffering from iatrogenic aortic dissection during percutaneous coronary intervention successfully treated with an emergency open-heart surgery. A conservative strategy should be pursuit only in small, localized lesions.

8.
Rev. bras. cir. cardiovasc ; 37(3): 412-416, May-June 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1376536

RESUMO

Abstract Introduction: Lymphomas arising from cardiac myxomas represent a particularly rare pathology, with only few cases reported in the literature. Case presentation: We report a complete excision of a malignant lymphoma arising from a cardiac myxoma in a 44-year-old female patient. The myxoma presented like a floating mass within the left atrium with a maximum diameter of 3.5 cm. The clinical post-operative period was uneventful and the patient was dismissed on the 6th post-operative day. Conclusion: This case reinforces the concept of radical excision of cardiac neoplasms.

9.
J Card Surg ; 37(7): 1887-1893, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35249231

RESUMO

AIMS: In the clinical practice a noteworthy proportion of severe symptomatic aortic stenosis patients presents with low-flow low-gradients features, these having reported a less favorable prognosis even when surgically or transcatheter treated. METHODS AND RESULTS: We retrospectively analyzed the prospectively collected data on 1051 consecutive patients undergone balloon-expandable transcatheter aortic valve replacement at our Institution from January 2008 to January 2020. We divided the population according with a mean aortic gradient (MAG) < or ≥40 mmHg and we performed a propensity-matched analysis based on the Society of Thoracic Surgery Score and age, obtaining two homogeneous groups of 314 patients each (Groups A and B, respectively). We then analyzed the outcomes of the two groups by implementing adjusted Cox models adjusted for significant clinical differences between the two groups, such as sex, ejection fraction, comorbidities and other variables not included in the propensity-matched analysis. The only variable associated with both cardiovascular and all-cause events was an ejection fraction ≤35%. Finally, a sensitivity analysis found that an ejection fraction ≤35% was associated with an increase cardiovascular and all-cause mortality only in patients with an indexed end-diastolic volume >97 ml/m2 (p = .0438 and .3363, respectively). CONCLUSIONS: In our series a MAG <40 mmHg was not found to be per se an independent risk factor for cardiac and all-cause mortality after transcatheter aortic valve replacement. The ejection fraction was found to be an independent risk factor only in the context of enlarged left ventricular dimensions.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular Esquerda
10.
Ann Thorac Surg ; 114(6): 2400, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35182518
11.
J Card Surg ; 37(4): 1094-1097, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35043478

RESUMO

During Ozaki procedure, relocating a valvular commissure could be technically demanding. This novel technique provides an easy tool to achieve valvular symmetry avoiding commissure shifting.


Assuntos
Valva Aórtica , Catéteres , Valva Aórtica/cirurgia , Humanos
12.
Braz J Cardiovasc Surg ; 37(3)2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35072410

RESUMO

INTRODUCTION: Lymphomas arising from cardiac myxomas represent a particularly rare pathology, with only few cases reported in the literature.Case presentation: We report a complete excision of a malignant lymphoma arising from a cardiac myxoma in a 44-year-old female patient. The myxoma presented like a floating mass within the left atrium with a maximum diameter of 3.5 cm. The clinical post-operative period was uneventful and the patient was dismissed on the 6th post-operative day. CONCLUSION: This case reinforces the concept of radical excision of cardiac neoplasms.


Assuntos
Neoplasias Cardíacas , Linfoma , Mixoma , Adulto , Feminino , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/patologia , Neoplasias Cardíacas/cirurgia , Humanos , Linfoma/diagnóstico por imagem , Linfoma/patologia , Linfoma/cirurgia , Mixoma/diagnóstico por imagem , Mixoma/patologia , Mixoma/cirurgia
13.
J Cardiothorac Vasc Anesth ; 36(4): 1073-1080, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34629238

RESUMO

OBJECTIVES: Right ventricular (RV) dysfunction is a significant cause of morbidity and mortality after cardiac surgery. Minimally invasive mitral valve surgery (MIMVS) increasingly is being performed. The authors aim was to evaluate postoperative RV function in patients who underwent MIMVS versus traditional mitral valve surgery. DESIGN: Six hundred seventy-five patients who underwent elective isolated mitral valve surgery at Centro Cardiologico Monzino from January 2016 to December 2019 were analyzed. After 1:1 propensity score matching, 60 patients were identified in the MIMVS (study group A) and 58 patients in the median sternotomy (control group B) and compared. SETTING: A university-affiliated scientific institute, monocentric. PARTICIPANTS: Patients. INTERVENTIONS: Mitral valve surgery. MEASUREMENTS AND MAIN RESULTS: No in-hospital deaths occurred. Aortic cross-clamp time (102 [87.5-119] v 83 [61-109] minutes, p = 0.0001), cardiopulmonary bypass duration (161.5 [142.5-181] v 105.5 [74-134] minutes, p < 0.0001) and intensive care unit stay (47 [44-72] v 45 [40-47] hours, p = 0.0015) were significantly longer in group A. The tricuspid annular plane systolic excursion was not different between group A and group B neither postoperatively (15 ± 3 v 14 ± 4 mm, p = 0.1) nor at three-month follow-up (18 ± 4 v 15 ± 3 mm, p = 0.3). No differences in peak postoperative lactates, inotropic score, central venous pressure, and pulmonary artery pulsatility index were observed. The length of hospital stay was significantly shorter in the minimally invasive group (ten [eight-13] v 12 [ten-17], p = 0.006). CONCLUSION: The authors study showed that the surgical strategy had no significant impact on postoperative RV function after mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Tempo de Internação , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Esternotomia/efeitos adversos , Resultado do Tratamento , Função Ventricular Direita
14.
Eur J Cardiothorac Surg ; 64(3)2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37669150

RESUMO

OBJECTIVES: The European System for Cardiac Operation Risk Evaluation II (EuroSCORE II) is the most common tool used to evaluate the perioperative risk of mortality after cardiac surgery in Europe, and its use is currently recommended by the relevant guidelines. However, recently, its role has been questioned: Several papers have suggested that these algorithms may no longer be adequate for risk prediction due to an overestimation of adult cardiac surgical risk. Our goal was to validate the EuroSCORE II in the prediction of 30-day in-hospital mortality in patients undergoing open cardiac surgery in a high-volume hospital. METHODS: In this retrospective cohort study, we included all patients who underwent cardiac surgery from January 2016 to May 2022 within the departments of cardiac surgery of the Monzino Cardiology Centre in Milan, Italy. We evaluated the discrimination power of the EuroSCORE II by using the receiver operating characteristic curve and the corresponding area under the curve. We performed calibration plots to assess the concordance between the model's prediction and the observed outcomes. RESULTS: A total of 4,034 patients were included (mean age = 65.1 years; 68% males), of which 674 (16.7%) underwent isolated coronary artery bypass grafting. The EuroSCORE II showed a good discrimination power in predicting 30-day in-hospital mortality (area under the curve = 0.834). However, for interventions performed in an elective setting, very low values of the EuroSCORE II overestimated the observed mortality, whereas for interventions performed in an emergency setting, EuroSCORE II values above 10 extensively underestimated the observed mortality. CONCLUSIONS: Our study suggests that the EuroSCORE II seems not to be a reliable score in estimating the true risk of death, especially in high-risk patients.

16.
J Cardiovasc Comput Tomogr ; 16(1): 51-53, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34610886

RESUMO

BACKGROUND: The aortic valve neocuspidalization (AVNeo) is an innovative surgical technique aiming at the reconstruction of the aortic valve using autologous pericardium. One of the main criticisms to AVNeo is the longer duration of the aortic clamping time (ACT) as compared to standard aortic valve replacement due to the sizing of the valve neocusps. METHODS: We retrospectively enrolled 30 consecutives patients underwent AVNeo. For each patient we developed a 3D aortic root model (ARM) based on CT-scan datasets. We retrospectively compared the leaflets measurements performed during surgery with those obtained on the corresponding ARMs. RESULTS: In 100% of cases no difference between the in vitro and in vivo measurements exceeded the acceptable error limit of 2 â€‹mm. The correlation of each single in vitro versus in vivo measurements demonstrates a strong coincidence between the two different methods of sizing (r â€‹> â€‹0,9, p â€‹< â€‹.0001). By analyzing the data considering the annulus perimeter and not the single cusp size, the perfect coincidence was to be found in 89.9% with a slight acceptable discrepancy (2 â€‹mm on total) in the remaining 10.1%. CONCLUSIONS: 3D-ARMs, printed from CT-scan, represent a reproducible process to obtain overlapping cusp sizes compared to those measured in-vivo, possibly reducing the ACT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
17.
Cell Tissue Bank ; 22(4): 675-683, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34523044

RESUMO

The worldwide pandemic outbreak due to severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) has created unprecedented challenges for public health services. Lombardy, region of the Northern Italy, has been the first area in the Western world whose organs and tissues procurement programs have had to face the virus pandemic emergency. We retrospectively collected and analyzed data about cardiovascular tissues (CT) in 2019 and in 2020. We aimed to describe the rapid evolution of SARS-CoV-2 regulation laws for tissue donor's selection and harvesting from February 2020 until January 2021. As expected the number of CT donors in 2020 was significantly lower than those of 2019 (66 vs. 99, p value 0.02). The total number of CT collected from donors have been 254 in 2019 and 206 in 2020 (p 0.28). Femoral arteries were the most required vascular tissues (55.5% in 2019 and 40% in 2020). Fifty-five and forty-eight pulmonary valves were implanted in 2019 and 2020, respectively. No differences were found for the types of CT requests between the 2 years. The median age of receivers of vascular tissues was 69.6 ± 14.6 years in the 2019 and 63.3 ± 14.9 years in 2020 (p < 0.01). The median age of receivers of pulmonary and aortic valves did not differ between the 2 years (9.32 ± 11.49 vs. 8.36 ± 10.66 and 48.67 ± 27.19 vs. 37.14 ± 31.97 respectively). Despite the dramatically reduction of donors, the number of CT collected has not decreased significantly and so far the CT distribution rate is comparable to those of 2019.


Assuntos
COVID-19 , Pandemias , Idoso , Idoso de 80 Anos ou mais , Pré-Escolar , Humanos , Itália/epidemiologia , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2 , Bancos de Tecidos , Estados Unidos
18.
J Clin Med ; 10(5)2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33669044

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an established technique to treat severe symptomatic aortic stenosis patients with a wide range of surgical risk. Currently, the common femoral artery is the first choice as the main access route for the procedure. The objective of this observational study is to report our experience on percutaneous and surgical cut-down transfemoral TAVRs comparing the two approaches. METHODS: From January 2014 to January 2019, five hundred eleven consecutive patients underwent TAVR for severe symptomatic aortic stenosis. We analyzed only elective transfemoral procedures. After propensity score-matching based on age, sex, EuroSCORE II, mean aortic gradient, and left ventricular ejection fraction, we obtained two homogeneous populations: surgical cut-down (n = 119) and percutaneous (n = 225), which were labeled Group 1 and Group 2, respectively. RESULTS: The main findings were that there were no significant procedural outcome differences between the two groups, but Group 2 patients had a shorter length of hospital stay and were more frequently discharged home. At follow-up, Group 1 patients had lower survival rates. CONCLUSIONS: An accurate preoperative assessment of the femoral access is mandatory to achieve satisfactory outcomes with transfemoral TAVRs. Nevertheless, the percutaneous approach allows shorter in-hospital stay and the need for rehabilitation, thus potentially decreasing the costs of the procedure.

20.
Ann Thorac Surg ; 111(6): 1937-1943, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33597118

RESUMO

BACKGROUND: The Ozaki procedure is an innovative surgical technique aiming at the reconstruction of the aortic valve with autologous pericardium to overcome the limitations of commercially available prostheses. METHODS: We retrospectively analyzed 71 patients who underwent the Ozaki operation at our center between October 2014 and February 2020. RESULTS: No in-hospital death occurred. Freedom from major adverse valve-related events was 97%. The aortic gradients and transvalvular velocity were significantly lower at the 3-month echocardiographic control than at the predischarge echocardiography (10.93 ± 5.38, P < .01 vs 16.24 ± 7.67, P < .01, respectively). The median follow-up period was 20.7 months (range, 2 to 47). Four patients showed mild/moderate aortic insufficiency (5.6%), and none showed severe aortic valve insufficiency. No patients underwent reoperation. CONCLUSIONS: Midterm outcome follow-up of the Ozaki procedure showed optimal results in terms of mortality, transaortic valve gradients, freedom from major adverse valve-related events, and recurrence of aortic valve insufficiency.


Assuntos
Valvopatia Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Pericárdio/transplante , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Transplante Autólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA