Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 974
Filtrar
1.
Radiologia (Engl Ed) ; 66(2): 107-113, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38614527

RESUMO

INTRODUCTION AND OBJECTIVES: To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. MATERIALS AND METHODS: Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. RESULTS: The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00 µGy at newborn, and 10.00 and 0.00µGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00 µGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). CONCLUSIONS: No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.


Assuntos
Gônadas , Lactente , Recém-Nascido , Humanos , Criança , Radiografia
2.
Radiography (Lond) ; 30(1): 408-415, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38176131

RESUMO

INTRODUCTION: This study aimed to compare the vascular enhancement and radiation dose in preoperative transcatheter aortic valve implantation (TAVI) computed tomography (CT) with a reduced contrast medium (CM) using volume scans in 256-multidetector row CT (MDCT) with a standard CM using 64-MDCT. METHODS: This study included 78 patients with preoperative TAVI CT with either 64- or 256-MDCT. The CM was injected at 1.5 mL/kg in the 64-MDCT group and 1.0 mL/kg in the 256-MDCT group. We compared vascular enhancement of the aortic root and access routes, image quality (IQ) scores, and radiation dose in both groups. RESULTS: Despite the reduced CM (by 33 %) in the 256-MDCT group, the mean vascular enhancement of the right and left subclavian arteries was significantly higher than that in the 64-MDCT group [284 and 267 Hounsfield units (HU) vs. 376 and 359 HU; p < 0.05]; however, no significant differences in the mean vascular enhancement in the ascending aorta, abdominal aorta at the celiac level, and bilateral common femoral arteries were observed between the two groups (p > 0.05 for all). The median IQ scores at the aortic root were higher in the 256-MDCT group than in the 64-MDCT group (3 vs. 4; p < 0.05), and those at the femoral access routes were comparable (4 vs. 4; p = 0.33). The mean effective dose was significantly reduced by 30 % in the 256-MDCT group (23.6 vs. 16.3 mSv; p < 0.05). CONCLUSION: In preoperative TAVI CT, volume scans using 256-MDCT provide comparable or better vascular enhancement and IQ with a 30 % reduction in CM and radiation dose than those using 64-MDCT. IMPLICATIONS FOR PRACTICE: Volume scan using 256-MDCT for preoperative TAVI CT may reduce CM and radiation dose in TAVI patients with renal dysfunction.


Assuntos
Estenose da Valva Aórtica , Iodo , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Tomografia Computadorizada Multidetectores , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doses de Radiação , Aorta Abdominal
3.
Radiography (Lond) ; 30(1): 382-387, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38150883

RESUMO

INTRODUCTION: To compare CT (computed tomography) values for enhancement of the abdominal aorta and liver parenchyma during dynamic contrast enhancement (CE) CT in cirrhotic patients with and without splenomegaly (SM). METHODS: We considered 258 patients (83 males and 46 females for the splenomegaly group, and 83 males and 46 females for the control group) for this retrospective study. We measured CT values in the abdominal aorta and hepatic parenchyma during the hepatic arterial (HAP) and portal venous (PVP) phases. The aortic CE at HAP and the hepatic parenchymal CE at PVP were compared between the two groups. For success rate of scans, we also calculated the optimal CE rates (>280 HU in the abdominal aorta and >50 HU in the hepatic parenchyma) for each group. RESULTS: In the SM group, the CE for abdominal aorta was decreased during the aortic phase for a dynamic CE-CT (p < 0.05). When evaluating the success rates, they were found to be 65.1 % and 58.9 % in the SM group and 81.4 % and 72.3 % in the non-SM group (p < 0.05). CONCLUSION: The success rate of scans and CE for the abdominal aorta during the aortic phase exhibited a significant decrease during dynamic CE-CT scans on patients with SM. Patients with SM may have reduced diagnostic ability with typical contrast injection protocols. IMPLICATIONS FOR PRACTICE: It may be necessary to change the injection rates and contrast medium volume during CE-CT depending on the presence or absence of SM.


Assuntos
Meios de Contraste , Esplenomegalia , Masculino , Feminino , Humanos , Estudos Retrospectivos , Esplenomegalia/diagnóstico por imagem , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
6.
Radiologia (Engl Ed) ; 64(6): 525-532, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36402538

RESUMO

INTRODUCTION AND OBJECTIVES: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. PATIENTS OR MATERIALS AND METHODS: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (n = 58) and leg (n = 58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast-noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. RESULTS: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. CONCLUSIONS: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.


Assuntos
Meios de Contraste , Veia Cava Superior , Humanos , Lactente , Recém-Nascido , Braço/diagnóstico por imagem , Perna (Membro) , Tomografia Computadorizada por Raios X/métodos
7.
Radiography (Lond) ; 28(4): 906-911, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35785641

RESUMO

INTRODUCTION: This study aims to predict endoleak after endovascular aneurysm repair (EVAR) using machine learning (ML) integration of patient characteristics, stent-graft configuration, and a selection of vessel lengths, diameters and angles measured using pre-operative computed tomography angiography (CTA). METHODS: We evaluated 1-year follow-up CT scans (arterial and delayed phases) in patients who underwent EVAR for the presence or absence of an endoleak. We also obtained data on the patient characteristics, stent-graft selection, and preoperative CT vessel morphology (diameter, length, and angle). The extreme gradient boosting (XGBoost) for the ML system was trained on 30 patients with endoleaks and 81 patients without. We evaluated 5217 items in 111 patients with abdominal aortic aneurysms, including the patient characteristics, stent-graft configuration and vascular morphology acquired using pre-EVAR abdominal CTA. We calculated the area under the curve (AUC) of our receiver operating characteristic analysis using the ML method. RESULTS: The AUC, accuracy, 95% confidence interval (CI), sensitivity, and specificity were 0.88, 0.88, 0.79-0.97, 0.85, and 0.91 for ML applying XGBoost, respectively. CONCLUSIONS: The diagnostic performance of the ML method was useful when factors such as the patient characteristics, stent-graft configuration and vessel length, diameter and angle of the vessels were considered from pre-EVAR CTA. IMPLICATIONS FOR PRACTICE: Based on our findings, we suggest that this is a potential application of ML for the interpretation of abdominal CTA scans in patients with abdominal aortic aneurysms scheduled for EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Algoritmos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Prótese Vascular , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/cirurgia , Humanos , Aprendizado de Máquina , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Radiography (Lond) ; 28(3): 766-771, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35428572

RESUMO

INTRODUCTION: The purpose of this study was to demonstrate that dose reduction does not compromise image quality when combining high helical pitch (HP) and the ECG-Edit function during low HP retrospectively gated computed tomography angiography (CTA). METHODS: This study made use of a pulsating cardiac phantom (ALPHA 1 VTPC). The heart rate (HR) of the cardiac phantom was changed in five intervals, every 5 beats per minute (bpm), from 40 to 60 bpm. Evaluation of a range of HR was important because data loss might occur when combining a low HR and high HP. We performed retrospectively gated CTA scans five times using a low HP (0.16) and high HP (0.24), for each of the five HR intervals, using a 64-detector row CT scanner. The CT volume dose index (CTDIvol) was recorded from the CT console of each scan. For the images with data loss, data were repaired using the ECG-Edit function. We compared the CTDIvol, estimated cardiac phantom volume, and the visualization of the coronary ladder phantom between HP 0.16, with or without repaired HP 0.24, using the ECG-Edit function. RESULTS: Data loss occurred with a HR of 40 bpm and 45 bpm when using HP 0.24. The CTDIvol was reduced by approximately 33% with HP 0.24 when compared with HP 0.16. There were no significant differences in the mean cardiac motion phantom volume and visualization scores between HP 0.16 and with and without repaired HP 0.24 using the ECG-Edit function (p < 0.05). CONCLUSION: The ECG-Edit function is potential useful for repairing the lost data in patients with a low HR, and when combined with a high HP, it is possible to reduce the radiation dose by approximately 33%. IMPLICATIONS FOR PRACTICE: The ECG-Edit function and high HP may be a viable option in pediatric CTA studies.


Assuntos
Angiografia por Tomografia Computadorizada , Eletrocardiografia , Criança , Angiografia Coronária/métodos , Redução da Medicação , Eletrocardiografia/métodos , Humanos , Doses de Radiação , Estudos Retrospectivos
10.
Radiography (Lond) ; 28(2): 440-446, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34844859

RESUMO

INTRODUCTION: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. METHODS: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. RESULTS: In group 1, median CT number and ranges was 345 (211-591) HU in the AAO, 324 (213-567) HU in the PA, and 62 (1-70) HU in the SVC. These values were 465 (308-669) HU, 467 (295-638) HU, and 234 (67-443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). CONCLUSION: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. IMPLICATIONS FOR PRACTICE: In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations.


Assuntos
Angiografia por Tomografia Computadorizada , Veia Cava Superior , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Lactente , Recém-Nascido , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Veia Cava Superior/diagnóstico por imagem
11.
Radiography (Lond) ; 28(1): 61-67, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34404578

RESUMO

INTRODUCTION: Deep learning approaches have shown high diagnostic performance in image classifications, such as differentiation of malignant tumors and calcified coronary plaque. However, it is unknown whether deep learning is useful for characterizing coronary plaques without the presence of calcification using coronary computed tomography angiography (CCTA). The purpose of this study was to compare the diagnostic performance of deep learning with a convolutional neural network (CNN) with that of radiologists in the estimation of coronary plaques. METHODS: We retrospectively enrolled 178 patients (191 coronary plaques) who had undergone CCTA and integrated backscatter intravascular ultrasonography (IB-IVUS) studies. IB-IVUS diagnosed 81 fibrous and 110 fatty or fibro-fatty plaques. We manually captured vascular short-axis images of the coronary plaques as Portable Network Graphics (PNG) images (150 × 150 pixels). The display window level and width were 100 and 700 Hounsfield units (HU), respectively. The deep-learning system (CNN; GoogleNet Inception v3) was trained on 153 plaques; its performance was tested on 38 plaques. The area under the curve (AUC) obtained by receiver operating characteristic analysis of the deep learning system and by two board-certified radiologists was compared. RESULTS: With the CNN, the AUC and the 95% confidence interval were 0.83 and 0.69-0.96, respectively; for radiologist 1 they were 0.61 and 0.42-0.80; for radiologist 2 they were 0.68 and 0.51-0.86, respectively. The AUC for CNN was significantly higher than for radiologists 1 (p = 0.04); for radiologist 2 it was not significantly different (p = 0.22). CONCLUSION: DL-CNN performed comparably to radiologists for discrimination between fatty and fibro-fatty plaque on CCTA images. IMPLICATIONS FOR PRACTICE: The diagnostic performance of the CNN and of two radiologists in the assessment of 191 ROIs on CT images of coronary plaques whose type corresponded with their IB-IVUS characterization was comparable.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Redes Neurais de Computação , Placa Aterosclerótica/diagnóstico por imagem , Estudos Retrospectivos
12.
Radiography (Lond) ; 28(2): 420-425, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702665

RESUMO

INTRODUCTION: To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula. METHODS: In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups. RESULTS: There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than those in the T-tube group (p < 0.05). CONCLUSION: The spiral-tube proved to be beneficial in improving the CT number for the AAO and PA, CNR, and visualisation score compared with the conventional T-tube during paediatric CCTA. IMPLICATIONS FOR PRACTICE: The spiral-tube may allow the visualisation of smaller blood vessels than those visualised by the conventional T-tube for paediatric patients in CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Criança , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Coração , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
13.
Radiography (Lond) ; 28(2): 412-419, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702666

RESUMO

INTRODUCTION: This study aimed to compare the correlation between the computed tomography (CT) enhancement rate of the venous to portal venous phase (VP-ER) and the extracellular volume (ECV) fraction with shear-wave ultrasound elastography (USE) findings in patients with liver fibrosis. METHODS: We included 450 patients with clinically suspected liver cirrhosis who underwent triphasic dynamic CT studies and USE. We compared the USE results with the unenhanced CT phase, with enhancement in the hepatic artery phase (HAP), portal venous phase (PVP), and venous phase (VP), and with the ECV fraction and the VP-ER. We also compared the area under the curve (AUC) of the receiver operating characteristic (ROC) curve of the ECV fraction and VP-ER with that of the values obtained with USE. RESULTS: The VP-ER was the most highly correlated with the liver stiffness value determined with USE (Pearson's correlation coefficient: r = 0.37), followed by enhancement in the PVP (r = -0.25), CT number on unenhanced CT scans (r = -0.22), the ECV fraction (r = 0.19), enhancement in the VP (r = 0.059), and enhancement in the HAP (r = -0.023) (all p < 0.01). The VP-ER showed a significantly higher AUC than the ECV fraction (0.75 vs 0.62) when the liver stiffness was >15 kPa in USE studies (p = 0.04). CONCLUSION: Compared to the ECV fraction, the VP-ER is more useful for predicting all degrees of liver fibrosis on routine triphasic dynamic CT images. IMPLICATIONS FOR PRACTICE: Although improvement is needed, the VP-ER has a higher diagnostic ability for liver fibrosis than the ECV fraction in clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Humanos , Cirrose Hepática/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Curva ROC , Tomografia Computadorizada por Raios X
14.
Radiography (Lond) ; 28(2): 447-453, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34774411

RESUMO

INTRODUCTION: The aim of this study was to generate virtual Magnetic resonance (MR) from computed tomography (CT) using conditional generative adversarial networks (cGAN). METHODS: We selected examinations from 22 adults who obtained their CT and MR lumbar spine examinations. Overall, 4 examinations were used as test data, and 18 examinations were used as training data. A cGAN was trained to generate virtual MR images from the CT images using the corresponding MR images as targets. After training, the generated virtual MR images from test data in epochs 1, 10, 50, 100, 500, and 1000 were compared with the original ones using the mean square error (MSE) and structural similarity index (SSIM). Additionally, two radiologists also performed qualitative assessments. RESULTS: The MSE of the virtual MR images decreased as the epoch of the cGANs increased from the original CT images: 8876.7 ± 1192.9 (original CT), 1567.5 ± 433.9 (Epoch 1), 1242.4 ± 442.0 (Epoch 10), 1065.8 ± 478.1 (Epoch 50), 1276.1 ± 718.9 (Epoch 100), 1046.7 ± 488.2 (Epoch 500), and 1031.7 ± 400.0 (Epoch 1000). No considerable differences were observed in the qualitative evaluation between the virtual MR images and the original ones, except in the structure of the spinal canal. CONCLUSION: Virtual MR lumbar spine images using cGANs could be a feasible technique to generate near-MR images from CT without MR examinations for evaluation of the vertebral body and intervertebral disc. IMPLICATIONS FOR PRACTICE: Virtual MR lumbar spine images using cGANs can offer virtual CT images with sufficient quality for attenuation correction for PET or dose planning in radiotherapy.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Tomografia Computadorizada por Raios X/métodos
16.
Radiography (Lond) ; 27(3): 888-896, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33820690

RESUMO

INTRODUCTION: With intra-arterial digital subtraction angiography (DSA) considered as the gold standard, we compared the diagnostic value of computed tomography angiography (CTA) and computed tomography-digital subtraction angiography (CT-DSA in hemodialysis (HD) patients suspected of having lower limb peripheral artery disease (PAD). METHODS: In this retrospective study, we enrolled 220 HD patients with suspected PAD. CT-DSA images were obtained by subtracting unenhanced images from enhanced images. The research team calculated the area under the curve (AUC), sensitivity, specificity, positive and negative predictive value (PPV, NPV), and recorded the diagnostic accuracy between the CTA and CT-DSA images using the DSA as gold standard. Visual evaluation of calcifications in the peripheral arteries were also compared between CTA and CT-DSA images. RESULTS: At the above-knee level, the CTA AUC [95% confidence interval (CI)] was 0.68 (CI 0.64-0.72), sensitivity and specificity were 60 and 81%, PPV and NPV were 85 and 53%, and accuracy was 67%. Below the knee, these values were 0.66 (CI 0.62-0.70), 71 and 79%, 79 and 47%, and 66%. For CT-DSA, above-knee, the AUC [95% CI] was 0.88 (CI 0.85-0.91), sensitivity and specificity were 84 and 92%, PPV and NPV were 89 and 97%, and accuracy was 93%. Below the knee, these values were 0.95 (CI 0.93-0.97), 95 and 93%, 96 and 83%, and 93%. The scores for the visualization of calcification in the peripheral arteries was significantly higher for CT-DSA than CTA (p < 0.05). CONCLUSIONS: CT-DSA helps to assess stenotic PAD with high calcification in the lower extremities of HD patients. IMPLICATIONS FOR PRACTICE: On CT-DSA images, the severity of vascular calcification can be assessed for HD patients suspected of PAD of the lower extremities.


Assuntos
Doença Arterial Periférica , Angiografia Digital , Humanos , Extremidade Inferior/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Diálise Renal , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
17.
Phys Rev Lett ; 126(12): 121801, 2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33834796

RESUMO

The rare decay K_{L}→π^{0}νν[over ¯] was studied with the dataset taken at the J-PARC KOTO experiment in 2016, 2017, and 2018. With a single event sensitivity of (7.20±0.05_{stat}±0.66_{syst})×10^{-10}, three candidate events were observed in the signal region. After unveiling them, contaminations from K^{±} and scattered K_{L} decays were studied, and the total number of background events was estimated to be 1.22±0.26. We conclude that the number of observed events is statistically consistent with the background expectation. For this dataset, we set an upper limit of 4.9×10^{-9} on the branching fraction of K_{L}→π^{0}νν[over ¯] at the 90% confidence level.

18.
Radiography (Lond) ; 27(3): 920-926, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33762147

RESUMO

INTRODUCTION: We compared the diagnostic performance of morphological methods such as the major axis, the minor axis, the volume and sphericity and of machine learning with texture analysis in the identification of lymph node metastasis in patients with thyroid cancer who had undergone contrast-enhanced CT studies. METHODS: We sampled 772 lymph nodes with histology defined tissue types (84 metastatic and 688 benign lymph nodes) that were visualised on CT images of 117 patients. A support vector machine (SVM), free programming software (Python), and the scikit-learn machine learning library were used to discriminate metastatic-from benign lymph nodes. We assessed 96 texture and 4 morphological features (major axis, minor axis, volume, sphericity) that were reported useful for the differentiation between metastatic and benign lymph nodes on CT images. The area under the curve (AUC) obtained by receiver operating characteristic analysis of univariate logistic regression and SVM classifiers were calculated for the training and testing datasets. RESULTS: The AUC for all classifiers in training and testing datasets was 0.96 and 0.86, at the SVM for machine learning. When we applied conventional methods to the training and testing datasets, the AUCs were 0.63 and 0.48 for the major axis, 0.70 and 0.44 for the minor axis, 0.66 and 0.43 for the volume, and 0.69 and 0.54 for sphericity, respectively. The SVM using texture features yielded significantly higher AUCs than univariate logistic regression models using morphological features (p = 0.001). CONCLUSION: For the identification of metastatic lymph nodes from thyroid cancer on contrast-enhanced CT images, machine learning combined with texture analysis was superior to conventional diagnostic methods with the morphological parameters. IMPLICATIONS FOR PRACTICE: Our findings suggest that in patients with thyroid cancer and suspected lymph node metastasis who undergo contrast-enhanced CT studies, machine learning using texture analysis is high diagnostic value for the identification of metastatic lymph nodes.


Assuntos
Neoplasias da Glândula Tireoide , Tomografia Computadorizada por Raios X , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Aprendizado de Máquina , Neoplasias da Glândula Tireoide/diagnóstico por imagem
19.
Radiography (Lond) ; 27(3): 840-846, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33549491

RESUMO

INTRODUCTION: To compare the radiation dose, diagnostic accuracy, and the resultant ablation procedures using 80 and 120-kVp cardiac computed tomography angiography (CCTA) protocols with the same contrast-to-noise ratio in patients scheduled for atrial fibrillation (AF) ablation. METHODS: This retrospective study was performed following institutional review board approval. We divided 140 consecutive patients who had undergone CCTA using a 64-MDCT scanner into two equal groups. Standard deviation (SD) of the CT number was set at 25 Hounsfield units (HU) for the 120-kVp protocol. To facilitate a reduction in radiation dose it was set at 40 HU for the 80 kVp protocol. We compared the two protocols with respect to the radiation dose, the diagnostic accuracy for detecting left atrial appendage (LAA) thrombi, matching for surface registration, and the resultant ablation procedures. RESULTS: At 120 kVp, the dose length product (DLP) was 2.2 times that at 80 kVp (1269.0 vs 559.0 mGy cm, p < 0.01). The diagnostic accuracy for thrombus detection was 100% using both protocols. There was no difference between the two protocols with respect to matching for surface registration. The protocols did not differ with respect to the subsequent time required for the ablation procedures and the ablation fluoroscopy time, and the radiation dose (p = 0.54, 0.33, and 0.32, respectively). CONCLUSION: For the same CNR, the DLP at 80 kVp (559.0 mGy cm) was 56% of that delivered at 120 kVp (1269.0 mGy cm). There was no reduction in diagnostic accuracy. IMPLICATIONS FOR PRACTICE: Maintaining CNR allows for a reduction in the radiation dose without reducing the image quality.


Assuntos
Fibrilação Atrial , Exposição à Radiação , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
20.
Sci Rep ; 10(1): 15311, 2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32943710

RESUMO

CeTe3 is a unique platform to investigate the itinerant magnetism in a van der Waals (vdW) coupled metal. Despite chemical pressure being a promising route to boost quantum fluctuation in this system, a systematic study on the chemical pressure effect on Ce3+(4f1) states is absent. Here, we report on the successful growth of a series of Se doped single crystals of CeTe3. We found a fluctuation driven exotic magnetic rotation from the usual easy-axis ordering to an unusual hard-axis ordering. Unlike in localized magnetic systems, near-critical magnetism can increase itinerancy hand-in-hand with enhancing fluctuation of magnetism. Thus, seemingly unstable hard-axis ordering emerges through kinetic energy gain, with the self-consistent observation of enhanced magnetic fluctuation (disorder). As far as we recognize, this order-by-disorder process in fermionic system is observed for the first time within vdW materials. Our finding opens a unique experimental platform for direct visualization of the rich quasiparticle Fermi surface deformation associated with the Fermionic order-by-disorder process. Also, the search for emergent exotic phases by further tuning of quantum fluctuation is suggested as a promising future challenge.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA