RESUMO
BACKGROUND: Systemic amyloidosis is a disease with heterogeneous clinical manifestations. Diagnosis depends on clinical suspicion combined with specific complementary methods. OBJECTIVE: To describe the clinical, laboratory, electrocardiographic, and imaging profile in patients with systemic amyloidosis with cardiac involvement. METHODS: This study was conducted with a convenience sample, analyzing clinical, laboratory, electrocardiographic, echocardiographic, nuclear medicine, and magnetic resonance data. Statistical significance was set at p < 0.05. RESULTS: A total of 105 patients were evaluated (median age of 66 years), 62 of whom were male. Of all patients, 83 had transthyretin (ATTR) amyloidosis, and 22 had light chain (AL) amyloidosis. With respect to ATTR cases, 68.7% were the hereditary form (ATTRh), and 31.3% were wild type (ATTRw). The most prevalent mutations were Val142Ile (45.6%) and Val50Met (40.3%). Time from onset of symptoms to diagnosis was 0.54 and 2.15 years, in the AL and ATTR forms, respectively (p < 0.001). Cardiac involvement was observed in 77.9% of patients with ATTR and in 90.9% of those with AL. Alterations were observed in atrioventricular and intraventricular conduction in 20% and 27.6% of patients, respectively, with 33.7% in ATTR and 4.5% in AL (p = 0.006). In the ATTRw form, there were more atrial arrhythmias than in ATTRh (61.5% versus 22.8%; p = 0.001). On echocardiogram, median septum thickness in ATTRw, ATTRh, and AL was 15 mm, 12 mm, and 11 mm, respectively (p = 0.193). Elevated BNP was observed in 89.5% of patients (median 249, ICR 597.7), and elevated troponin was observed in 43.2%. CONCLUSION: In this setting, it was possible to characterize cardiac involvement in systemic amyloidosis in its different subtypes by means of clinical history and the diagnostic methods described.
FUNDAMENTO: Amiloidose sistêmica é uma doença com manifestações clínicas diversas. O diagnóstico envolve suspeita clínica, aliada a métodos complementares. OBJETIVO: Descrever o perfil clínico, laboratorial, eletrocardiográfico e de imagem no acometimento cardíaco da amiloidose sistêmica. MÉTODOS: Estudo de uma amostra de conveniência, analisando dados clínicos, laboratoriais, eletrocardiográficos, ecocardiográficos, medicina nuclear e ressonância magnética. Considerou-se significância estatística quando p < 0,05. RESULTADOS: Avaliaram-se 105 pacientes (com mediana de idade de 66 anos), sendo 62 homens, dos quais 83 indivíduos apresentavam amiloidose por transtirretina (ATTR) e 22 amiloidose por cadeia leve (AL). Na ATTR, 68,7% eram de caráter hereditário (ATTRh) e 31,3% do tipo selvagem (ATTRw). As mutações mais prevalentes foram Val142Ile (45,6%) e Val50Met (40,3%). O tempo de início dos sintomas ao diagnóstico foi 0,54 e 2,15 anos nas formas AL e ATTR (p < 0,001), respectivamente. O acometimento cardíaco foi observado em 77,9% dos ATTR e 90,9% dos AL. Observaram-se alterações de condução atrioventricular em 20% e intraventricular em 27,6% dos pacientes, sendo 33,7 % na ATTR e 4,5% das AL (p = 0,006). A forma ATTRw apresentou mais arritmias atriais que os ATTRh (61,5% x 22,8%; p = 0,001). Ao ecocardiograma a mediana da espessura do septo na ATTRw x ATTRh x AL foi de 15 mm x 12 mm x 11 mm (p = 0,193). Observou-se BNP elevado em 89,5% dos indivíduos (mediana 249 ng/mL, IQR 597,7) e elevação da troponina em 43,2%. CONCLUSÃO: Foi possível caracterizar, em nosso meio, o acometimento cardíaco na amiloidose sistêmica, em seus diferentes subtipos, através da história clínica e dos métodos diagnósticos descritos.
Assuntos
Neuropatias Amiloides Familiares , Amiloidose , Cardiologia , Cardiomiopatias , Idoso , Neuropatias Amiloides Familiares/diagnóstico por imagem , Amiloidose/diagnóstico por imagem , Brasil , Cardiomiopatias/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Pré-Albumina/genética , Encaminhamento e ConsultaRESUMO
BACKGROUND: We aimed to identify, among Chronic Chagas Cardiomyopathy (CCC) patients with left ventricular dysfunction (LVD) and non-left bundle branch block (non-LBBB), subgroups with different functional and mechanical patterns of global longitudinal strain (GLS) and intraventricular dyssynchrony (IVD) at rest and after exercise stress test, and reclassify them using a new echocardiographic approach. METHODOLOGY: In this single-center cross-sectional study, 40 patients with CCC, left ventricular ejection fraction (LVEF) ≤ 35% and non-LBBB underwent rest echocardiography and then treadmill exercise stress echocardiography with GLS and IVD analysis. The sample was divided into four groups, based on GLS and IVD significant variation between rest and exercise: GLS + IVD+ (9 patients); GLS + IVD- (9 patients); GLS-IVD+ (10 patients); GLS-IVD- (10 patients). RESULTS: At rest, median LVEF was 28% (21.3%-33%) and GLS (-7% (-5%/-9.3%), were not different among groups. The average response of GLS was an increase of 0.74% over rest values, and the average response of IVD was a decrease of 6.9 ms. Group GLS-IVD+ presented more dyssynchrony at rest (p = 0.01). Left atrial (LA) volume (higher in GLS-IVD-) (p = 0.022) and TAPSE (higher in GLS + IVD+) (p = 0.015) were also different among groups at baseline. Of the 40 patients evaluated, 27 (67.5%) had very severe LVD (GLS < -8%). In addition, among these patients, 11 patients had contractile reserve after undergoing stress echocardiography. CONCLUSIONS: In patients with CCC, severe LVD and non-LBBB, the evaluation of GLS and IVD between rest and exercise was able to reclassify myocardial function and to identify subgroups with contractile reserve and significant dyssynchronopathy.
Assuntos
Cardiomiopatia Chagásica , Disfunção Ventricular Esquerda , Cardiomiopatia Chagásica/diagnóstico por imagem , Estudos Transversais , Ecocardiografia , Humanos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Função Ventricular EsquerdaRESUMO
Resumo Fundamento Amiloidose sistêmica é uma doença com manifestações clínicas diversas. O diagnóstico envolve suspeita clínica, aliada a métodos complementares. Objetivo Descrever o perfil clínico, laboratorial, eletrocardiográfico e de imagem no acometimento cardíaco da amiloidose sistêmica. Métodos Estudo de uma amostra de conveniência, analisando dados clínicos, laboratoriais, eletrocardiográficos, ecocardiográficos, medicina nuclear e ressonância magnética. Considerou-se significância estatística quando p < 0,05. Resultados Avaliaram-se 105 pacientes (com mediana de idade de 66 anos), sendo 62 homens, dos quais 83 indivíduos apresentavam amiloidose por transtirretina (ATTR) e 22 amiloidose por cadeia leve (AL). Na ATTR, 68,7% eram de caráter hereditário (ATTRh) e 31,3% do tipo selvagem (ATTRw). As mutações mais prevalentes foram Val142Ile (45,6%) e Val50Met (40,3%). O tempo de início dos sintomas ao diagnóstico foi 0,54 e 2,15 anos nas formas AL e ATTR (p < 0,001), respectivamente. O acometimento cardíaco foi observado em 77,9% dos ATTR e 90,9% dos AL. Observaram-se alterações de condução atrioventricular em 20% e intraventricular em 27,6% dos pacientes, sendo 33,7 % na ATTR e 4,5% das AL (p = 0,006). A forma ATTRw apresentou mais arritmias atriais que os ATTRh (61,5% x 22,8%; p = 0,001). Ao ecocardiograma a mediana da espessura do septo na ATTRw x ATTRh x AL foi de 15 mm x 12 mm x 11 mm (p = 0,193). Observou-se BNP elevado em 89,5% dos indivíduos (mediana 249 ng/mL, IQR 597,7) e elevação da troponina em 43,2%. Conclusão Foi possível caracterizar, em nosso meio, o acometimento cardíaco na amiloidose sistêmica, em seus diferentes subtipos, através da história clínica e dos métodos diagnósticos descritos.
Abstract Background Systemic amyloidosis is a disease with heterogeneous clinical manifestations. Diagnosis depends on clinical suspicion combined with specific complementary methods. Objective To describe the clinical, laboratory, electrocardiographic, and imaging profile in patients with systemic amyloidosis with cardiac involvement. Methods This study was conducted with a convenience sample, analyzing clinical, laboratory, electrocardiographic, echocardiographic, nuclear medicine, and magnetic resonance data. Statistical significance was set at p < 0.05. Results A total of 105 patients were evaluated (median age of 66 years), 62 of whom were male. Of all patients, 83 had transthyretin (ATTR) amyloidosis, and 22 had light chain (AL) amyloidosis. With respect to ATTR cases, 68.7% were the hereditary form (ATTRh), and 31.3% were wild type (ATTRw). The most prevalent mutations were Val142Ile (45.6%) and Val50Met (40.3%). Time from onset of symptoms to diagnosis was 0.54 and 2.15 years, in the AL and ATTR forms, respectively (p < 0.001). Cardiac involvement was observed in 77.9% of patients with ATTR and in 90.9% of those with AL. Alterations were observed in atrioventricular and intraventricular conduction in 20% and 27.6% of patients, respectively, with 33.7% in ATTR and 4.5% in AL (p = 0.006). In the ATTRw form, there were more atrial arrhythmias than in ATTRh (61.5% versus 22.8%; p = 0.001). On echocardiogram, median septum thickness in ATTRw, ATTRh, and AL was 15 mm, 12 mm, and 11 mm, respectively (p = 0.193). Elevated BNP was observed in 89.5% of patients (median 249, ICR 597.7), and elevated troponin was observed in 43.2%. Conclusion In this setting, it was possible to characterize cardiac involvement in systemic amyloidosis in its different subtypes by means of clinical history and the diagnostic methods described.
Assuntos
Humanos , Masculino , Feminino , Adulto , Cardiologia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Encaminhamento e Consulta , Brasil , Pré-Albumina/genética , EcocardiografiaRESUMO
AIMS: We tested the hypothesis that the effects of combined inspiratory muscle training and aerobic exercise training (IMT + AET) on muscle sympathetic nerve activity (MSNA) and forearm blood flow in patients with heart failure with reduced ejection fraction are more pronounced than the effects of AET alone. METHODS AND RESULTS: Patients aged 30-70 years, New York Heart Association Functional Class II-III, and left ventricular ejection fraction ≤40% were randomly assigned to four groups: IMT (n = 11), AET (n = 12), IMT + AET (n = 9), and non-training (NT; n = 10). MSNA was recorded using microneurography. Forearm blood flow was measured by venous occlusion plethysmography and inspiratory muscle strength by maximal inspiratory pressure. IMT consisted of 30 min sessions, five times a week, for 4 months. Moderate AET consisted of 60 min sessions, three times a week for 4 months. AET (-10 ± 2 bursts/min, P = 0.03) and IMT + AET (-13 ± 4 bursts/min, P = 0.007) reduced MSNA. These responses in MSNA were not different between AET and IMT + AET groups. IMT (0.22 ± 0.08 mL/min/100 mL, P = 0.03), AET (0.27 ± 0.09 mL/min/100 mL, P = 0.01), and IMT + AET (0.35 ± 0.12 mL/min/100 mL, P = 0.008) increased forearm blood flow. No differences were found between groups. AET (3 ± 1 mL/kg/min, P = 0.006) and IMT + AET (4 ± 1 mL/kg/min, P = 0.001) increased peak oxygen consumption. These responses were similar between these groups. IMT (20 ± 3 cmH2 O, P = 0.005) and IMT + AET (18 ± 3 cmH2 O, P = 0.01) increased maximal inspiratory pressure. No significant changes were observed in the NT group. CONCLUSIONS: IMT + AET causes no additive effects on neurovascular control in patients with heart failure with reduced ejection fraction compared with AET alone. These findings may be, in part, because few patients had inspiratory muscle weakness.
Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Exercício Físico , Insuficiência Cardíaca/terapia , Humanos , Músculos , Volume SistólicoRESUMO
Abstract Background: Estimative of left ventricular ejection fraction (LVEF) is a major indication for echocardiography. Speckle tracking echocardiography (STE) allows analysis of LV contraction mechanics which includes global longitudinal strain (GLS) and twist/torsion, both the most widely used. Direct comparison of correlations between these novel parameters and LVEF has never been done before. Objective: This study aims to check which one has the highest correlation with LVEF. Methods: Patients with normal LVEF (> 0,55) and systolic dysfunction (LVEF <0,55) were prospectively enrolled, and underwent echocardiogram with STE analysis. Correlation of variables was performed by linear regression analysis. In addition, correlation among levels of LV systolic impairment was also tested. Results: A total of 131 patients were included (mean age, 46 ± 14y; 43%, men). LVEF and GLS showed a strong correlation (r = 0.95; r2 = 0.89; p < 0.001), more evident in groups with LV systolic dysfunction than those with preserved LVEF. Good correlation was also found with global longitudinal strain rate (r = 0.85; r2 = 0.73; p < 0.001). Comparing to GLS, correlation of LVEF and torsional mechanics was weaker: twist (r = 0.78; r2 = 0.60; p < 0.001); torsion (r = 0.75; r2 = 0.56; p < 0.001). Conclusion: GLS of the left ventricle have highly strong positive correlation with the classical parameter of ejection fraction, especially in cases with LV systolic impairment. Longitudinal strain rate also demonstrated a good correlation. GLS increments analysis of LV systolic function. On the other hand, although being a cornerstone of LV mechanics, twist and torsion have a weaker correlation with LV ejection, comparing to GLS.
Resumo Fundamento: A estimativa da fração de ejeção do ventrículo esquerdo (FEVE) é uma das pincipais indicações para a ecocardiografia. Speckle tracking (ST) permite a análise da mecânica de contração do VE que inclui a deformação (strain) longitudinal global (SLG) e o twist / torção, sendo ambos os mais utilizados. A comparação direta de correlações entre esses novos parâmetros e a FEVE nunca foi feita antes. Objetivo: Verificar qual delas tem a maior correlação com a FEVE. Métodos: Pacientes com FEVE normal (> 0,55) e disfunção sistólica (FEVE < 0,55) foram prospectivamente inscritos e submetidos a ecocardiograma com análise do ST. A correlação das variáveis foi realizada por análise de regressão linear. Além disso, também foi testada a correlação entre os níveis de comprometimento sistólico do VE. Resultados: Foram incluídos 131 pacientes (média de idade de 46 ± 14 anos e 43% de homens). A FEVE e SLG apresentaram forte correlação (r = 0,95; r2 = 0,89; p < 0,001), mais evidente em grupos com disfunção sistólica do VE do que naqueles com FEVE preservada. Também foi encontrada boa correlação com a taxa de deformação (strain rate) longitudinal (SRL) global (r = 0,85; r2 = 0,73; p < 0,001). Comparando-a à SLG, a correlação entre FEVE e mecânica de torção foi mais fraca: twist (r = 0,78; r2 = 0,60; p < 0,001); Torção (r = 0,75, r2 = 0,56, p < 0,001). Conclusão: A SLG do ventrículo esquerdo apresenta alta correlação positiva com o parâmetro clássico de fração de ejeção, principalmente nos casos de comprometimento sistólico do VE. O SRL também demonstrou uma boa correlação. A SLG incrementa a análise da função sistólica do VE. Por outro lado, apesar de ser a pedra angular da mecânica do VE, o twist e a torção têm uma correlação mais fraca com a ejeção do VE, quando comparados ao SLG.
Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Anormalidade Torcional/diagnóstico por imagem , Função Ventricular Esquerda , Cardiopatias/diagnóstico por imagem , Ecocardiografia , Variações Dependentes do Observador , Estudos Prospectivos , Cardiopatias/fisiopatologiaAssuntos
Humanos , Feminino , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana/métodos , Cardiopatias Congênitas/terapia , Toracotomia , Diagnóstico Precoce , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Ventrículos do CoraçãoRESUMO
Fundamento: Microbolhas intravenosas (MB) e ultrassom (US) têm sido utilizados para recanalizar vasos epicárdicos em modelos animais de infarto agudo do miocárdio com supradesnivelamento do segmento ST (IAM-SST). Nenhum estudo prévio demonstrando o valor dessa técnica foi realizado em humanos. Objetivo: Estudo piloto realizado com o objetivo de avaliar a eficácia da utilização de MB e US (sonotrombólise) sobre as taxas iniciais de recanalização de artérias coronarianas em pacientes com IAM-SST. Método: Estudamos 24 pacientes (18 homens, média etária de 58 ± 9 anos) que deram entrada no serviço de emergência com IAM-SST. Pacientes foram randomizados em um dos três grupos: MB + US especificamente desenvolvido para este protocolo, com duração de pulso 4-20 useg e índice mecânico (IM) >1.0 (n = 7), MB + US com impulsos repetitivos de alto IM (1.0), com duração de pulso < 2 useg (n = 8), ou grupo controle (n = 9) que recebeu MB + US apenas paraanalisar a perfusão dentro da área de risco. As MB utilizadas no estudo consistiam em solução de Definity 3%. Todos os pacientes foram submetidos a intervenção coronariana percutânea (ICP). Resultados: As médias dos tempos porta-balão foram 76 ± 35 minutos no grupo MB + US 4-20 useg, 70 ± 20 minutos no grupo MB + US impulsos repetitivos e 81 ± 13 minutos no grupo controle (p = NS). Recanalização angiográfica antes da angioplastia foi observada em 75% dos pacientes tratados com MB + US impulsos repetitivos, em 43% nogrupo tratado com MB + US 4-20 useg e em 11% do grupo controle (p = < 0,05). Conclusão: Utilização de MB e US com impulsos repetitivos pode ser um método para recanalização precoce de artérias epicárdicas em pacientes com IAM-SST.
Background: Intravenous microbubbles (MB) and transthoracic ultrasound (US) have been utilized to recanalize epicardial vessels in animalmodels of ST segment elevation myocardial infarction (STEMI). The feasibility of such an ultrasound-guided approach in humans with STEMIhave not been studied. Objective: Pilot study with the aim to evaluate the efficacy of MB plus US on coronary artery recanalization rate in patients with STEMI. Methods: Twenty-four patients (18 men, mean age 58 ± 9 years) admitted to the emergency room with STEMI were randomized into 3 groups. Patients either received MB plus custom designed high mechanical index (MI) impulses at 4-20 usec pulse duration (n = 7), MB plus diagnostichigh MI (MI = 1.0) with multiple impulses < 2 usec pulse duration (n = 8) or MB plus limited diagnostic high MI impulses (< 5) just to analyzemyocardial perfusion, control group (n = 9). MB utilized in the study consisted of a solution of Definity 3%. All randomized groups underwent emergent PCI.Results: The mean door-to-balloon time were 76 ± 35 minutes in group US 4-20 usec, 70 ± 20 minutes in group US multiple impulses and 81 ± 13 minutes in control group (p = NS). Angiographic recanalization before PCI was observed in 75% of patients treated with US multiple impulses, in 43% for US 4-20 usec and 11% in control (p = <0.05).Conclusion: Utilization of MB and diagnostic US with multiple impulses may be a method of achieving early recanalization in acute STEMI.