Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 68(807): 225-47, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7735761

RESUMO

Contrast enhanced magnetic resonance imaging (MRI) is a very versatile and effective technique for detecting and characterizing lesions, for identifying a variety of patho-physiological abnormalities, and for providing perfusion and functional information. The application of contrast enhanced MRI to many clinical and research indications has emerged because of the rapid evolution in imaging techniques, improved methodology, and the development of efficient and specific contrast agents. Problems related to optimizing parameters and dosage have been due to complex interplay of relaxation times, biophysical mechanisms and acquisition parameters. A knowledge of basic biophysical aspects is therefore essential for a full understanding of the results obtained for different organs under different conditions, and for optimizing the image parameters and dosage of contrast agents. This article underlines the biophysical basis of the effects of contrast agents in MRI, identifies the problems involved in optimizing the parameters for maximum efficiency, and presents a general overview of the clinical studies and research applications in the central nervous system, perfusion abnormalities, hepatobiliary system, musculoskeletal system and the gastrointestinal tract. The section on perfusion studies includes a discussion of quantitative analysis and kinetic models describing the effects of contrast agents. Finally, a critical evaluation of the scope and limitations of contrast enhanced MRI is presented.


Assuntos
Doenças do Sistema Nervoso Central/diagnóstico , Sistema Nervoso Central , Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Fenômenos Biofísicos , Biofísica , Meios de Contraste/efeitos adversos , Meios de Contraste/farmacocinética , Sistema Digestório/patologia , Feminino , Humanos , Hepatopatias/diagnóstico , Neoplasias/diagnóstico , Perfusão
2.
Magn Reson Imaging ; 13(1): 169-76, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7898276

RESUMO

In this paper the results are presented of a joint European quantitative data-analysis study on a series of in vivo NMR time-domain test signals. The purpose of this study was to investigate, whether the quantitative MRS results from the various European biomedical research-centres can be made more comparable and reproducible. From the results of the study it can be concluded that in case of heavily overlapping NMR lines the quantifications should be done by some form of model function fitting and that, whenever possible, prior knowledge on the quantitative parameters should be incorporated into the quantification algorithms.


Assuntos
Espectroscopia de Ressonância Magnética , Controle de Qualidade
3.
Magn Reson Imaging ; 8(6): 691-8, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2266794

RESUMO

The relaxation time T1 values and nuclear Overhauser enhancement factor for 31P signal were determined in model solutions of metabolites ATP, PCr and Pi, and AMP at two frequencies and in H2O and 2H2O solutions. The data were analyzed to resolve the contribution of different relaxation mechanisms. A knowledge of NOE is important in the light of recent applications of double resonance methods to enhance the sensitivity of in vivo 31P spectroscopy. The results show that chemical shift anisotropy is the dominant mechanism for 31P in ATP at the high field, whereas the dipolar interaction mechanism is the main feature for the 31P relaxation of PCr and Pi. The dipolar mechanism responsible for NOE originates from interactions of solvent water with 31P moiety. Implications for in vivo spectroscopy are indicated.


Assuntos
Espectroscopia de Ressonância Magnética , Fósforo , Trifosfato de Adenosina , Fosfocreatina , Soluções
4.
Magn Reson Imaging ; 6(2): 185-94, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3374292

RESUMO

The EEC Protocol for in vitro measurement of T1 and T2 presented in paper II of this series was tested in 15 centers on a variety of instruments. This article discusses the results of this protocol trial using biological samples (rat liver and thigh muscle) and two reference gel samples. Each reference gel was prepared as a single batch, dispensed into appropriate sample tubes and sent to all participants. Details of instrument types and operating conditions are given, along with measurement frequencies and temperatures and the results of precision testing. The relaxation time measurements from the gels for the trial are compared with temperature and frequency effects examined in independent centers under similar conditions. The relaxation time values for biological tissues are examined in the light of the scatter of such values in the general literature. To check the effects of data analysis methods on relaxation times, full relaxation data for one reference sample was provided by each group. This was re-analyzed in three centers using different methods; these results are compared with the values calculated by each group using its own method. In general, the results from different groups show good consistency with the reference values. The use of this Protocol has helped reduce scatter in results from biological samples and has provided information for improvement of individual operating conditions and improvement of the protocol to its final form.


Assuntos
União Europeia , Espectroscopia de Ressonância Magnética , Projetos de Pesquisa/normas , Animais , Técnicas In Vitro , Espectroscopia de Ressonância Magnética/instrumentação , Ratos , Padrões de Referência
5.
Magn Reson Imaging ; 6(2): 215-22, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3374295

RESUMO

A standard method has been developed for the production of reference materials for NMR relaxation time measurement. These are based on agarose gels doped with gadolinium. The reproducibility and temporal stability of the gels have been found to be excellent. Electron microscope studies have shown good homogeneity. The relaxation behavior of such gels has been mathematically modeled with good agreement with experiment.


Assuntos
União Europeia , Espectroscopia de Ressonância Magnética , Sefarose , Gadolínio , Géis , Padrões de Referência
8.
Magn Reson Med ; 2(2): 176-9, 1985 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3831685

RESUMO

The relaxation properties of agar gels render it a potentially useful basic reference material for calibrating the NMR equipment. The T1 and T2 values are close to the values observed for most biological tissues; they are stable and can be varied by controlling the concentration of MnCl2. The temperature, concentration, and volume dependence of T1 and T2 were studied.


Assuntos
Espectroscopia de Ressonância Magnética , Ágar , Calibragem
11.
Biosci Rep ; 3(7): 599-608, 1983 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-6313089

RESUMO

We have examined the n.m.r. relaxation times T1 and T2 of water protons for liver (mouse, human) and brain (mouse) at different temperatures and subjected to various conditions of conservation and degeneration. After tissue degeneration, T1 and T2 behave differently and their variations are characteristic of each tissue type. The results show that the initial values at +4 degrees C are consistent when the experimental protocol formulated in this study is followed.


Assuntos
Água Corporal/análise , Química Encefálica , Fígado/análise , Espectroscopia de Ressonância Magnética , Animais , Biópsia , Feminino , Humanos , Camundongos , Prótons , Manejo de Espécimes , Temperatura , Preservação de Tecido
15.
Radiat Environ Biophys ; 14(4): 311-5, 1977 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-594316

RESUMO

The effects of gamma-irradiation and changes in the macromolecular structure on the water proton resonance spectra observed in frozen and liwuid solutions have been compared for the DNA and polynucleotide solutions, using H2O or mixed H2O/D2O solvents. The results indicate that in order to obtain information concerning the role of hydration water in mediating the overall radiation damage, the NMR studies must be performed in the frozen state.


Assuntos
DNA/efeitos da radiação , Polirribonucleotídeos/efeitos da radiação , Temperatura Baixa , Raios gama , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA