Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Pharm ; 631: 122469, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36509223

RESUMO

Pharmaceutical product development guided by Quality by Design (QbD) is based on a complete understanding of the critical process parameters (CPPs) that are important for achieving the desired product critical quality attributes (CQAs). The effect of process settings, such as the screw speed, the throughput, the barrel temperature, and the screw configuration, is a well-known factor in the setup of pharmaceutical hot melt extrusion (HME) processes. A CPP that has not yet been extensively researched is the type of cross-section geometry of the screw elements. Typically, pharmaceutical extruders have double-flighted screw cross-sections, with some elements having a single- or triple-flighted element section. The exception is a NANO16 extruder from Leistritz, with all screw elements having a triple-flighted screw geometry. We investigated the process setup and scale-up to a double-flighted extruder experimentally and in silico via a digital twin. Two formulations were processed on a NANO16 extruder and virtually transferred to a ZSE18 double-flighted co-rotating twin-screw extruder. Detailed smoothed particle hydrodynamics simulations of all screw elements available from both extruders were performed, and their efficiency in conveying, pressure build-up, and power consumption were studied. Reduced-order 1D HME simulations, which were carried out to investigate the process space and scalability of both extruders, were experimentally validated.


Assuntos
Tecnologia de Extrusão por Fusão a Quente , Temperatura Alta , Composição de Medicamentos , Temperatura , Preparações Farmacêuticas , Tecnologia Farmacêutica
2.
Pharmaceutics ; 14(12)2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36559111

RESUMO

The aim of this study was to develop a continuous pilot-scale solidification and characterization of self-emulsifying drug delivery systems (SEDDSs) via hot melt extrusion (HME) using Soluplus® and Kollidon® VA-64. First, an oil-binding capacity study was performed to estimate the maximal amount of SEDDSs that the polymers could bind. Then, HME was conducted using a Coperion 18 mm ZSK18 pilot plant-scale extruder with split-feeding of polymer and SEDDS in 10, 20, and 30% w/w SEDDSs was conducted. The prepared extrudates were characterized depending on appearance, differential scanning calorimetry, wide-angle X-ray scattering, emulsification time, droplet size, polydispersity index, and cloud point. The oil-binding studies showed that the polymers were able to bind up to 50% w/w of liquid SEDDSs. The polymers were processed via HME in a temperature range between 110 and 160 °C, where a plasticizing effect of the SEDDSs was observed. The extrudates were found to be stable in the amorphous state and self-emulsified in demineralized water at 37 °C with mean droplet sizes between 50 and 300 nm. A cloud point and phase inversion were evident in the Soluplus® samples. In conclusion, processing SEDDSs with HME could be considered a promising alternative to the established solidification techniques as well as classic amorphous solid dispersions for drug delivery.

3.
Int J Pharm X ; 3: 100084, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34159312

RESUMO

Following our study on the impact of hot melt extrusion (HME) process conditions on the product quality, we expanded our investigation to assessing the effect of scale-up on the product quality. To this end, we studied the influence of process settings and different scale-up variants on the active pharmaceutical ingredient (API) degradation in a pilot plant scale extruder. Six scale-up variants were investigated and none of them could replicate the product quality from the original process setup on a lab-scale extruder. By analyzing several process-dependent and -independent variables and cross referencing them to the experiments in the lab-scale extruder, we identified certain patterns. The results of the reduced order mechanistic 1D HME simulation of various process states made it possible to establish a correlation between the achieved API degradation and the local melt temperature and the exposure time in specific zones along the screw configuration. Since the same melt temperature and exposure time correlations were also valid for the lab scale-extruder, such an approach could be used in the future to predict the product quality as a function of processing conditions fully in silico prior to the first extrusion trials.

4.
Int J Pharm X ; 2: 100062, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33299982

RESUMO

In product development, it is crucial to choose the appropriate drug manufacturing route accurately and timely and to ensure that the technique selected is suitable for achieving the desired product quality. Guided by the QbD principles, the pharmaceutical industry is currently transitioning from batch to continuous manufacturing. In this context, process understanding and prediction are becoming even more important. With regard to hot melt extrusion, the process setup, optimization and scale-up in early stages of product development are particularly challenging due to poor process understanding, complex product-process relationship and a small amount of premix available for extensive experimental studies. Hence, automated, quick and reliable process setup and scale-up requires simulation tools that are accurate enough to capture the process and determine the product-process relationships. To this end, the effect of process settings on the degradation of the active pharmaceutical ingredient (API) in a lab-scale Leistritz ZSE12 extruder was investigated. As part of the presented study, the limitations of traditional process analysis using integral process values were investigated, together with the potential that simulations may have in predicting the process performance and the product quality. The results of our investigation indicate that the average melt temperatures and the exposure times in specific zones along the screw configuration correlate well with the API degradation values and can be used as potent process design criteria to simplify the process development.

5.
Pharmaceutics ; 12(6)2020 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-32599822

RESUMO

To avoid any type of cross-contamination, residue-free production equipment is of utmost importance in the pharmaceutical industry. The equipment cleaning for continuous processes such as hot melt extrusion (HME), which has recently gained popularity in pharmaceutical applications, necessitates extensive manual labour and costs. The present work tackles the HME cleaning issue by investigating two cleaning strategies following the extrusion of polymeric formulations of a hormonal drug and for a sustained release formulation of a poorly soluble drug. First, an in-line quantification by means of UV-Vis spectroscopy was successfully implemented to assess very low active pharmaceutical ingredient (API) concentrations in the extrudates during a cleaning procedure for the first time. Secondly, a novel in-situ solvent-based cleaning approach was developed and its usability was evaluated and compared to a polymer-based cleaning sequence. Comparing the in-line data to typical swab and rinse tests of the process equipment indicated that inaccessible parts of the equipment were still contaminated after the polymer-based cleaning procedure, although no API was detected in the extrudate. Nevertheless, the novel solvent-based cleaning approach proved to be suitable for removing API residue from the majority of problematic equipment parts and can potentially enable a full API cleaning-in-place of a pharmaceutical extruder for the first time.

6.
AAPS PharmSciTech ; 21(5): 176, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32572701

RESUMO

This paper presents a rational workflow for developing enabling formulations, such as amorphous solid dispersions, via hot-melt extrusion in less than a year. First, our approach to an integrated product and process development framework is described, including state-of-the-art theoretical concepts, modeling, and experimental characterization described in the literature and developed by us. Next, lab-scale extruder setups are designed (processing conditions and screw design) based on a rational, model-based framework that takes into account the thermal load required, the mixing capabilities, and the thermo-mechanical degradation. The predicted optimal process setup can be validated quickly in the pilot plant. Lastly, a transfer of the process to any GMP-certified manufacturing site can be performed in silico for any extruder based on our validated computational framework. In summary, the proposed workflow massively reduces the risk in product and process development and shortens the drug-to-market time for enabling formulations.


Assuntos
Química Farmacêutica , Temperatura Alta , Composição de Medicamentos , Modelos Químicos , Solubilidade
7.
Int J Pharm ; 506(1-2): 35-45, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27090153

RESUMO

Previously, we introduced a one-step nano-extrusion (NANEX) process for transferring aqueous nano-suspensions into solid formulations directly in the liquid phase. Nano-suspensions were fed into molten polymers via a side-feeding device and excess water was eliminated via devolatilization. However, the drug content in nano-suspensions is restricted to 30 % (w/w), and obtaining sufficiently high drug loadings in the final formulation requires the processing of high water amounts and thus a fundamental process understanding. To this end, we investigated four polymers with different physicochemical characteristics (Kollidon(®) VA64, Eudragit(®) E PO, HPMCAS and PEG 20000) in terms of their maximum water uptake/removal capacity. Process parameters as throughput and screw speed were adapted and their effect on the mean residence time and filling degree was studied. Additionally, one-dimensional discretization modeling was performed to examine the complex interactions between the screw geometry and the process parameters during water addition/removal. It was established that polymers with a certain water miscibility/solubility can be manufactured via NANEX. Long residence times of the molten polymer in the extruder and low filling degrees in the degassing zone favored the addition/removal of significant amounts of water. The residual moisture content in the final extrudates was comparable to that of extrudates manufactured without water.


Assuntos
Composição de Medicamentos/métodos , Nanopartículas/química , Suspensões/química , Química Farmacêutica/métodos , Metilcelulose/análogos & derivados , Metilcelulose/química , Metilmetacrilatos/química , Polietilenoglicóis/química , Polímeros/química , Pirrolidinas/química , Compostos de Vinila/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA