Artigo em Japonês | MEDLINE | ID: mdl-39384373

RESUMO

PURPOSE: The effects of scanning parameters such as CT system performance, CT bed geometry, and upper limb position on effective diameter (ED) and water equivalent diameter (WED) have not been assessed. The purpose of this study was to compare both ED and WED obtained with various CT systems with theoretical values and to assess their accuracy. METHODS: Jaszczak cylindrical phantom (Data Spectrum, Durham, NC, USA), NEMA IEC body phantom (AcroBio, Tokyo), and thoracic bone phantom were used in this study with and without upper limb phantom. The ED, WED, and size-specific dose estimate (SSDE) obtained using 8 types of CT systems were computed using radiation dose control software. RESULTS: The EDs had <5% error for all systems, but the error increased as the aspect ratio of the phantom increased. The accuracy of WED varied depending on the CT systems, with a maximum difference of 3.57 cm between systems. The influence of the upper limb depended on the shape of the bed of the CT systems, which affected the correlation between ED as well as WED and SSDE. CONCLUSION: Although the ED did not show any dependence on the CT system, the accuracy of WED for fusion CT was low. We found that there are issues in the management of scanning data, including the upper limb.

2.
Radiol Phys Technol ; 2024 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-39419861

RESUMO

To visualize the X-ray fields, overlaps, and over-beaming on the skin surface during spiral head CT scanning. The measured pitch factors were determined by measuring 3 rotation times, 11 table-feed speeds, and an X-ray beam width. The X-ray fields, overlaps, and over-beaming on the skin surface were calculated via computer-aided design-based X-ray beam modeling, and the values obtained using the nominal pitch and measured pitch factors were compared. The X-ray fields with measured pitch factors exceeded those with nominal pitch factors. The overlaps increased with a decrease in the nominal pitch and measured pitch factors and were observed even at a nominal pitch factor of 1.0. The most stretched over-beaming field was observed with the measured pitch factor of 0.670. The technique can show the overlaps of the X-ray fields and may determine the adequate start angle to prevent overlaps to the eye lens.

3.
J Radiol Prot ; 44(2)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38722292

RESUMO

According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr-1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant's lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant's lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: 'assisted ventilation,' 'head holding,' 'body holding,' and 'raising patient's arm.' The air kerma of lens position was not significantly different for each assistance type (p< 0.05, Kruskal-Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. 'Raising patient's arm' and 'head holding' exhibited stronger correlations, which required less table movement during the CT scan than 'assisted ventilation' and 'body holding'.


Assuntos
Cristalino , Exposição Ocupacional , Doses de Radiação , Tomografia Computadorizada por Raios X , Cristalino/efeitos da radiação , Humanos , Exposição Ocupacional/análise , Proteção Radiológica , Exposição à Radiação/análise
4.
J Radiol Prot ; 44(2)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38507786

RESUMO

Vision badge is an eye lens dosimeter to measureHp(3). This study aimed to evaluate the basic characteristics of the Vision badge and its performance as an eye lens dosimeter for endoscopists by phantom study. Energy dependence was evaluated by changing the tube voltage to 50 kV (effective energy of 27.9 keV), 80 kV (32.2 keV), and 120 kV (38.7 keV). Dose linearity was evaluated by changing the number of irradiation to 1, 5, and 40 times, which corresponded to 0.53, 5.32, and 21.4 mGy. Batch uniformity was evaluated by calculating the coefficient of variation ofHp(3) obtained from 10 Vision badges. Angular dependence was evaluated at 0° (perpendicular to the incident direction of x-rays), 30°, 60°, 75°, and 90°. The Vision badge and optically stimulated luminescence (OSL) dosimeter were attached to the inside of the radioprotective glasses, worn on the endoscopist phantom, and theHp(3) obtained from both dosimeters were compared. TheHp(3) obtained from the Vision badge with 38.7 keV was 3.8% higher than that with 27.9 keV. The Vision badge showed excellent linearity (R2= 1.00) with the air kerma up to 21.4 mGy. The coefficient of variation of theHp(3) for 10 Vision badges was 3.47%. The relative dose of the Vision badge decreased as the angle increased up to 75°, but increased at 90°. TheHp(3) obtained by the OSL dosimeter and the Vision badge were decreased as the endoscopist phantom was turned away from the patient phantom. TheHp(3) that was obtained by the Vision badge was 35.5%-55.0% less than that obtained by the nanoDot. In conclusion, the Vision badge showed specific angular dependence due to its shape, but satisfactory basic properties were exhibited for all characteristics. In phantom study, the Vision badge showed generally similar trends with the OSL dosimeter.


Assuntos
Cristalino , Dosímetros de Radiação , Humanos , Radiografia , Raios X , Imagens de Fantasmas , Cristalino/efeitos da radiação
5.
Phys Eng Sci Med ; 47(2): 691-701, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38483784

RESUMO

Sufficient dose reduction may not be achieved if radioprotective curtains are folded. This study aimed to evaluate the scattered dose rate distribution and physician eye lens dose at different curtain lengths. Using an over-couch fluoroscopy system, dH*(10)/dt was measured using a survey meter 150 cm from the floor at 29 positions in the examination room when the curtain lengths were 0% (no curtain), 50%, 75%, and 100%. The absorbed dose rates in the air at the positions of endoscopist and assistant were calculated using a Monte Carlo simulation by varying the curtain length from 0 to 100%. The air kerma was measured by 10 min fluoroscopy using optically stimulated luminescence dosimeters at the eye surfaces of the endoscopist phantom and the outside and inside of the radioprotective goggles. At curtain lengths of 50%, 75%, and 100%, the ratios of dH*(10)/dt relative to 0% ranged from 80.8 to 104.1%, 10.5 to 61.0%, and 11.8 to 24.8%, respectively. In the simulation, the absorbed dose rates at the endoscopist's and assistant's positions changed rapidly between 55 and 75% and 65% and 80% of the curtain length, respectively. At the 0%, 50%, 75%, and 100% curtain lengths, the air kerma at the left eye surface of the endoscopist phantom was 237 ± 29, 271 ± 30, 37.7 ± 7.5, and 33.5 ± 6.1 µGy, respectively. Therefore, a curtain length of 75% or greater is required to achieve a sufficient eye lens dose reduction effect at the position of the endoscopist.


Assuntos
Cristalino , Método de Monte Carlo , Doses de Radiação , Proteção Radiológica , Espalhamento de Radiação , Fluoroscopia , Humanos , Imagens de Fantasmas , Relação Dose-Resposta à Radiação
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(4): 374-384, 2024 Apr 20.
Artigo em Japonês | MEDLINE | ID: mdl-38417899

RESUMO

PURPOSE: This study aimed to compare the dose evaluation methods by constructing simulation models using the Monte Carlo calculation code and propose an evaluation method for cone beam CT (CBCT) that ensures accuracy and practicality. METHODS: The Particle and Heavy Ion Transport code System (PHITS) ver. 3.26 was used as the Monte Carlo calculation code. CBCT doses were measured by CB dose index (CBDI) and American Association of Physicists in Medicine task group 111 (TG111) methods. The CBDI was compared with the equilibrium doses obtained by the TG111 method. RESULTS: Although CBDI was lower than equilibrium doses obtained by the TG111 method, its practicality was ensured because it can be measured using the dosimeter and phantom that are commonly used. In contrast, the TG111 method guarantees accuracy, but it is difficult to prepare a long phantom to obtain the equilibrium dose. The TG111 method with a phantom length of 15 cm underestimated the equilibrium dose by 20% compared to that with a phantom length of 45 cm that satisfies the dose equilibrium. Therefore, the equilibrium dose obtained by the TG111 method with a phantom length of 15 cm is multiplied by 1.20 to obtain the equilibrium dose equivalent to that with a phantom length of 45 cm. CONCLUSION: This study has proposed the dose evaluation method that combines guarantees accuracy and practicality in CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos
7.
Radiol Phys Technol ; 17(1): 207-218, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38127219

RESUMO

Solid-state detectors (SSDs) may be used along with a lead collimator for half-value layer (HVL) measurement using computed tomography (CT) with or without a tin filter. We aimed to compare HVL measurements obtained using three SSDs (AGMS-DM+ , X2 R/F sensor, and Black Piranha) with those obtained using the single-rotation technique with lead apertures (SRTLA). HVL measurements were performed using spiral CT at tube voltages of 70-140 kV without a tin filter and 100-140 kV (Sn 100-140 kV) with a tin filter in increments of 10 kV. For SRTLA, a 0.6-cc ionization chamber was suspended at the isocenter to measure the free-in-air kerma rate ( K ˙ air ) values. Five apertures were made on the gantry cover using lead sheets, and four aluminum plates were placed on these apertures. HVLs in SRTLA were obtained from K ˙ air decline curves. Subsequently, SSDs inserted into the lead collimator were placed on the gantry cover and used to measure HVLs. Maximum HVL differences of AGMS-DM+ , X2 R/F sensor, and Black Piranha with respect to SRTLA without/with a tin filter were - 0.09/0.6 (only two Sn 100-110 kV) mm, - 0.50/ - 0.6 mm, and - 0.17/(no data available) mm, respectively. These values were within the specification limit. SSDs inserted into the lead collimator could be used to measure HVL using spiral CT without a tin filter. HVLs could be measured with a tin filter using only the X2 R/F sensor, and further improvement of its calibration accuracy with respect to other SSDs is warranted.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada Espiral , Imagens de Fantasmas , Calibragem
10.
Radiat Prot Dosimetry ; 199(11): 1166-1173, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37227144

RESUMO

This study aimed to develop an energy-based Hp(3) measurement method using a solid-state detector (SSD). Incident and entrance surface air kerma were measured using an ionization chamber placed free-in-air and in front of an anthropomorphic or slab phantom. Subsequently, three SSDs were placed free-in-air, and half-value layer and readings were obtained. After measurements, an X-ray beam quality correction factor $\left ({{k}}_{{Q},{{Q}}_{\mathbf{0}}}^{{SSD}}\right)$, backscatter factor (BSF) and conversion factor from incident air kerma to Hp(3) (C3) were determined. Then, the incident air kerma by SSD $\left ({{K}}_{{a},{i}}^{{SSD}}\right )$, Hp(3) and Hp(3)/${{K}}_{{a},{i}}^{{SSD}}$ were calculated. The ${{k}}_{{Q},{{Q}}_{\mathbf{0}}}^{{SSD}}$ was almost consistent for all SSDs. The C3 and BSF were found to increase as tube potential increased. The Hp(3)/${{K}}_{{a},{i}}^{{SSD}}$ calculated with the anthropomorphic and slab phantoms were consistent within 2.1% and 2.6% for all SSDs, respectively. This method improves the energy dependence of Hp(3) measurement and can estimate the Hp(3) measurement error for dedicated Hp(3) dosemeters.


Assuntos
Radiometria , Radiografia , Raios X , Imagens de Fantasmas , Radiometria/métodos , Método de Monte Carlo
11.
Radiol Phys Technol ; 16(3): 355-365, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37204682

RESUMO

This study aimed to discover the associations between the number of computed tomography (CT) scanners and the population, as well as number of medical resources to identify regional disparities in Japan. The number of CT scanners was tabulated for each detector row of CT scanners for hospitals and clinics in each prefecture. The number of CT scanners, patients, medical doctors, radiological technologists, facilities, and beds per 100,000 population was compared. Additionally, the number of hospitals with ≥ 200 beds and multidetector-row CT scanners with ≥ 64 rows were tabulated, and their ratios were calculated. Medical institutions in Japan have installed 14,595 scanners. CT scanners per 100,000 population were the highest in Kochi Prefecture, although the number of CT scanners in hospitals was the highest in Tokyo Prefecture. Multivariate analysis revealed the number of radiological technologists (ß coefficient: 0.49; P = 0.03), facilities (ß coefficient: 0.12; P < 0.01) and beds (ß coefficient: 0.46; P < 0.01) as independent factors for the number of CT scanners. Prefectures with a high proportion of hospitals with ≥ 200 beds also had a relatively high proportion of CT scanners with ≥ 64 rows (P < 0.01). Our survey revealed an association between regional disparities in the number of CT scanners in Japan, the population, and number of medical resources. A positive correlation was found between hospital size and number of CT scanners with ≥ 64 rows.


Assuntos
Tomografia , Humanos , Japão , Tomógrafos Computadorizados
12.
J Radiol Prot ; 43(2)2023 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-37023744

RESUMO

Medical staff sometimes assists patients in the examination room during computed tomography (CT) scans for several purposes. This study aimed to investigate the dose reduction effects of four radioprotective glasses with different lead equivalents and lens shapes. A medical staff phantom was positioned assuming body movement restraint of the patient during chest CT, and Hp(3) at the eye surfaces of the medical staff phantom and inside the lens of the four types of radioprotective glasses were measured by changing the distance of the staff phantom from the gantry, eye height, and width of the nose pad. The Hp(3) at the right eye surface with glasses of 0.50-0.75 mmPb and 0.07 mmPb was approximately 83.5% and 58.0%, respectively, lower than that without radioprotective glasses. The dose reduction rates at left eye surface increased with over-glass type glasses by 14%-28% by increasing the distance from the CT gantry to the staff phantom from 25 to 65 cm. The dose reduction rates at the left eye surface decreased with over-glass type glasses by 26%-31% by increasing the height of the eye lens for the medical staff phantom from 130 to 170 cm. The Hp(3) on the left eye surface decreased by 46.9% with the widest nose pad width compared to the narrowest nose pad width for the glasses with adjustable nose pad width. The radioprotective glasses for staff assisting patients during CT examinations should have a high lead equivalent and no gap around the nose and under the front lens.


Assuntos
Cristalino , Exposição Ocupacional , Proteção Radiológica , Humanos , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Corpo Clínico , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise
13.
Br J Radiol ; 96(1146): 20230086, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37086068

RESUMO

OBJECTIVE: We aimed to examine the factors contributing to radiation exposure exceeding the DRL of the transnasal ileus tube placement in this post hoc analysis from the cohort of the REX-GI study. METHODS: Patients with transnasal ileus tubes were enrolled in the rex-gi study from may 2019 to december 2020. We investigated the endoscope insertion time (min), procedure time (min), tube insertion length (cm), fluoroscopy time (FT: min), air kerma at the patient entrance reference point (Ka.r: mGy), and air kerma-area product (PKA: Gycm2). The third quartile value of the PKA value was calculated as the diagnostic reference level (DRL) value. We explored the factors associated with radiation exposure exceeding the DRL. RESULTS: In the REX-GI study, 496 patients who underwent transnasal ileus tube placement were enrolled. The median age of the patients was 71 years. The median endoscopy insertion time, procedure time, and tube insertion length were 6 min, 20 min, and 170 cm, respectively. The third quartile/median FT, Ka.r, and PKA were 18/11.9 min, 99.2/54.4 mGy, and 46.9/28 Gycm2, respectively. The third quartile value of PKA (47 Gycm2) was set as the DRL value. There were differences in distribution by the hospital. Compared with procedures under the DRL, the FT (19 vs 10 min), procedure time (25 vs 18 min), and tube insertion length (185 vs 165 cm) were significantly longer for procedures above the DRL. CONCLUSION: We report the DRL for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance. ADVANCES IN KNOWLEDGE: Transnasal ileus tube placement under fluoroscopy guidance is a standard clinical procedure for bowel obstruction. However, the appropriate radiation dose level has not yet been established.We report the (DRL) for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance.


Assuntos
Íleus , Obstrução Intestinal , Humanos , Idoso , Níveis de Referência de Diagnóstico , Endoscopia , Fluoroscopia , Doses de Radiação , Íleus/diagnóstico por imagem
15.
Phys Eng Sci Med ; 46(1): 141-150, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36508073

RESUMO

We aimed to verify whether the image quality of large low-contrast objects can be improved using visual model-based iterative reconstruction (VMR) while maintaining the visibility of conventional filtered back projection (FBP) and reducing radiation dose through physical and visual evaluation. A 64-row multi-slice CT system with SCENARIA View (FUJIFILM healthcare Corp. Tokyo, Japan) was used. The noise power spectrum (NPS), task-based transfer function (TTF), and signal-to-noise ratio (SNR) were physically evaluated. A low contrast object as a substitute for a liver mass was visually evaluated. In the noise measurement, STD1 showed an 18% lower noise compared to FBP. STR4 was able to reduce noise by 58% compared to FBP. The NPS of VMR was similar to those of FBP from low to high spatial frequency. The NPS of VMR reconstructions showed a similar variation with frequency as FBP reconstructions. STD1 showed the highest 10% TTF, and higher 10% TTF was observed with lower VMR level. The SNR of VMR was close to that of FBP, and higher SNR was observed with higher VMR level. In the results of the visual evaluation, there was no significant difference in visual evaluation between STD1 and FBP (p = 0.99) and between STD2 and FBP (p = 0.56). We found that the NPS of VMR images was similar to that of FBP images, and it can reduce noise and radiation dose by 25% and 50%, respectively, without decreasing the visual image quality compared to FBP.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Exame Neurológico , Imagens de Fantasmas
17.
J Appl Clin Med Phys ; 23(12): e13851, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36448537

RESUMO

This study aims to investigate the effects of the position correction of size-specific dose estimates (SSDE) on patient dose estimation in cone beam computed tomography (CBCT). The relationship between the phantom position and absorbed dose in the right breast was studied using optically stimulated luminescence dosimeters and a simulated human body phantom. The effect of position correction for CT dose index (CTDI) on SSDE was investigated in 51 patients who underwent right breast irradiation by comparing the SSDE with position correction and SSDE without position correction. The absorbed dose in the right breast tended to decrease by 10.2% as the phantom was placed away from the center of CBCT. The mean and standard deviation of SSDE were 2.54 ± 0.29 and 2.92 ± 0.30 mGy with and without position correction, respectively. The SSDE with position correction was 13.1% lower than that without position correction (p < 0.05). SSDE was different when the patient's torso center was located at the isocenter of CBCT, and when it was not. The same tendency was seen in the case of the breast. Therefore, if the center of the patient is not at the acquisition center of the CT scanner, position correction is required when estimating SSDE.


Assuntos
Mama , Tomografia Computadorizada de Feixe Cônico , Humanos , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Tomógrafos Computadorizados , Imagens de Fantasmas
19.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(11): 1349-1357, 2022 Nov 20.
Artigo em Japonês | MEDLINE | ID: mdl-36328484

RESUMO

PURPOSE: The purpose of this study was to evaluate the accuracy of incident air kerma (Ka,r) and air kerma-area product (PKA) displayed on over-couch-type X-ray fluoroscopic systems by comparing them with the measured values. METHODS: An ionizing chamber was placed at the patient entrance reference point to measure the Ka,r. The PKA was calculated by multiplying the Ka,r by the irradiation area. These measured values were compared with the displayed values. RESULTS: The differences between measured and displayed Ka,r and PKA were less than ±35%, which was the criteria of the Japanese Industrial Standards (JIS). However, the accuracy of the displayed values differed depending on the manufacturer and the device. CONCLUSION: Although no error exceeding the JIS criteria was observed, it is necessary to understand the characteristics of the X-ray fluoroscopic systems related to displayed dose and to manage the systems by performing dose measurements periodically.


Assuntos
Indústrias , Humanos , Raios X
20.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(10): 1176-1186, 2022 Oct 20.
Artigo em Japonês | MEDLINE | ID: mdl-36058849

RESUMO

PURPOSE: The purpose of this study was to evaluate the differences in the organ doses and the effective doses using three types of automated organ dose estimation software for low-dose computed tomography (CT) screening for lung cancer and to evaluate the correlations between each dose and size-specific dose estimates (SSDEs). METHODS: Seventy-two adults who underwent low-dose CT screening for lung cancer were included, and the organ doses and the effective doses were calculated using each of automated organ dose estimation software. We evaluated differences between software for the organ doses and the effective doses and the correlations between each dose and SSDEs. RESULTS: Differences in organ doses and effective doses were observed among the software. The organ doses showed a strong correlation (r=0.833-0.995) with SSDEs for organs within the scan range. The effective doses showed a strong correlation (r=0.830-0.970) with SSDEs, although there were significant differences among the software. CONCLUSION: Although the organ doses and the effective doses differed between software, it may be possible to estimate them from SSDEs by using linear regression equations.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Adulto , Humanos , Doses de Radiação , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Software , Automação , Imagens de Fantasmas , Método de Monte Carlo