Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Int J Implant Dent ; 10(1): 24, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722448

RESUMO

PURPOSE: The objective of the present study was to ascertain the effect of immediate occlusal loading after implant placement on osseointegration and the micro/nanostructure of the surrounding bone. METHODS: After extraction of a rat maxillary right second molar, an implant was placed immediately with initial fixation (2 N< ). The implants were placed to avoid occlusal loading due to mastication, and in the loaded group, a superstructure was fabricated and subjected to occlusal loading. Bone morphometry, collagen fiber anisotropy, and biological apatite (BAp) crystallite alignment were quantitatively evaluated in both groups after extraction and fixation of the jaw bone at Days 7 and 21 after surgery. RESULTS: Osseointegration was observed in both groups. Bone morphometry showed significant differences in bone volume, trabecular number, trabecular thickness and bone mineral density (BMD) at Days 21 postoperatively (P < 0.05). A significant difference was also found in the trabecular separation at Days 7 postoperatively (P < 0.05). In the evaluation of collagen fiber anisotropy, collagen fiber bundles running differently from the existing bone were observed in both groups. In terms of BAp crystallite alignment, a specific structure was observed in the reconstructed new bone after implantation, and preferential orientation of BAp crystallite alignment was observed in the longitudinal direction of the implants in the Day 21 postoperative loaded group. CONCLUSION: When sufficient initial fixation is achieved at the time of dental implant placement, then the applied masticatory load may contribute to rapidly achieving not only bone volume, but also adequate bone quality after implant placement.


Assuntos
Carga Imediata em Implante Dentário , Osseointegração , Animais , Ratos , Osseointegração/efeitos dos fármacos , Masculino , Densidade Óssea/fisiologia , Implantes Dentários , Ratos Wistar , Maxila/cirurgia , Colágeno/metabolismo , Microtomografia por Raio-X
2.
J Funct Biomater ; 15(3)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38535249

RESUMO

The hyoid is the only bone in the human body that is completely independent, not forming a joint with any other bone; its position is maintained by the suprahyoid and infrahyoid muscles, as well as several ligaments. The purpose of this study was to ascertain the effect of the functional pressure arising from these muscles and ligaments on the hyoid body structure from its bone mineral density, bone quality, and histological observations. The area between the mesial-most part of each lesser horn and the center of the hyoid body was divided equally into four measurement regions. We conducted histological investigations at each measurement region and observed the entheses. To analyze bone mass and bone quality, we also measured bone mineral density (BMD) and analyzed biological apatite (BAp) crystallite orientation in the same regions. Histological observations identified periosteal insertions and fibrocartilaginous entheses. There was no significant difference in BMD between any of the measurement regions, but the preferential orientation of BAp crystallites was stronger in the infrahyoid muscles and ligaments, where fibrocartilaginous entheses are found, than in other places. This suggests that the functional pressure at these sites might exert a major effect not only on the morphological characteristics of the entheses but also on bone quality.

3.
Quant Imaging Med Surg ; 14(2): 1652-1659, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415165

RESUMO

Background: Sagittal split ramus osteotomy is an established procedure used in oral and maxillofacial surgery. Major bleeding is representative intraoperative complication involves vessels such as the inferior alveolar, facial, and maxillary arteries and accompanying veins, in particular the retromandibular vein (RMV). We previously described the RMV course patterns using embalmed cadavers. However, owing to the possible influence of formalin fixation and unclear skeletal classification of the jaws, the present study aimed to use contrast-enhanced computed tomography to confirm the RMV in patients with defined jaw deformities. Methods: Twenty patients with orthognathic jaw deformities (40 sides) were included. The RMV and the lateral and posterior views of the mandible were evaluated using contrast-enhanced computed tomography. Course patterns and RMV positions were classified as previously reported. Results: Three patterns were identified in the lateral view. Type A: RMV posterior to the posterior border of the ramus (n=25; 62.5%). Type B: adjoining the posterior border of the ramus (n=12; 30.0%). Type C: anterior to the posterior border of the ramus (n=3; 7.5%). Five course patterns were identified in the posterior view. Pattern I: rectilinear course running medial to the posterior border of the ramus (n=3; 7.5%). Pattern II: diagonal course running medially from immediately posterior to posterior border of the ramus (n=11; 27.5%). Pattern III: rectilinear course running immediately posterior to the posterior border of the ramus (n=12; 30.0%). Pattern IV: diagonal course running from lateral to medial relative to the posterior border of the ramus (n=8; 20.0%). Pattern V: diagonal course running from lateral to immediately posterior relative to the posterior border of the ramus (n=6; 15.0%). In the no-course pattern group, the RMV inferior to the lingula was lateral to its position and superior to that of the lingula. In half of the cases, the left and right sides exhibited different running patterns. We observed no correlation between the skeletal patterns of jaw deformities and the course of the RMV. Conclusions: Type B/Pattern II that runs in a straight line bordering the posterior margin of the ramus requires the most attention during surgery. These findings suggest the possibility of predicting intraoperative bleeding risk.

4.
J Prosthodont Res ; 68(2): 336-346, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37612075

RESUMO

PURPOSE: This study aims to develop a numerical prediction method for the average and standard deviation values of the largely varied fatigue life of additively manufactured commercially pure titanium (CPTi grade 2) clasps. Accordingly, the proposed method is validated by applying it to clasps of different shapes. METHODS: The Smith-Watson-Topper (SWT) equation and finite element analysis (FEA) were used to predict the average fatigue life. The variability was expressed by a 95% reliability range envelope based on the experimentally determined standard deviation. RESULTS: When predicting the average fatigue life, the previously determined fatigue parameters implemented in the SWT equation were found to be useful after conducting fatigue tests using a displacement-controlled fatigue testing machine. The standard deviation with respect to stroke and fatigue life was determined for each clasp type to predict variability. The proposed prediction method effectively covered the experimental data. Subsequently, the prediction method was applied to clasps of different shapes and validated through fatigue tests using 22 specimens. Finally, the fracture surface was observed using scanning electron microscopy (SEM). Many manufacturing process-induced defects were observed; however, only the surface defects where the maximum tensile stress occurred were crucial. CONCLUSIONS: It was confirmed that the fatigue life of additively manufactured pure titanium parts is predictable before the manufacturing process considering its variability by performing only static elasto-plastic FEA. This outcome contributes to the quality assurance of patient-specific clasps without any experimental investigation, reducing total costs and response time.


Assuntos
Ligas de Cromo , Prótese Parcial Removível , Humanos , Titânio , Reprodutibilidade dos Testes , Grampos Dentários , Teste de Materiais
5.
Anat Sci Int ; 99(1): 138-145, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37987921

RESUMO

Recently, it has become clear that peri-muscular tissues play a significant role in the deterioration of muscle function. Understanding the function and regeneration of muscle, as well as its surrounding tissues, is crucial to determining the causes of muscular illnesses. However, the regeneration process of the myotendinous junction (MTJ), the most closely related peri-muscular tissue, is still unknown. Therefore, we generated a mouse model of MTJ injury by collagenase injection and searched for the process of regeneration of the MTJ and its adjacent regions. The MTJ region was damaged by collagenase injection, which greatly increased the tendon cross sectional area. Collagenase injections increased the proportion of myofibers with a central nucleus, which is a characteristic of regenerating muscle. The collagenase injection group had myofibers with central nuclei and expressing MTJ markers. Additionally, we measured the length of MTJs using serial cross sections of the soleus muscle and discovered that MTJs at 2 weeks after collagenase injection were shorter compared to the control group, with a propensity to progressively recover their length over time. The results showed that MTJs undergo morphological regeneration even when severely damaged, and that this regeneration occurs in conjunction with muscle regeneration. We anticipate that these findings will be valuable in upcoming research on motor unit regeneration.


Assuntos
Tendão do Calcâneo , Camundongos , Animais , Junção Miotendínea , Músculo Esquelético , Regeneração
6.
J Clin Med ; 12(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38068460

RESUMO

Genioplasty is performed for the orthognathic surgical correction of dentofacial deformities. This article reports a safe and accurate method for genioplasty combining a novel three-dimensional (3D) device with mixed reality (MR)-assisted surgery using a registration marker and a head-mounted display. Four types of devices were designed based on the virtual operation: a surgical splint with a connector; an osteotomy device; a repositioning device; and a registration marker. Microsoft HoloLens 2 and Holoeyes MD were used to project holograms created using computed tomography (CT) data onto the surgical field to improve the accuracy of the computer-aided designed and manufactured (CAD/CAM) surgical guides. After making an incision on the oral vestibule, the splint was fitted on the teeth and the osteotomy device was mounted at the junction site, placed directly on the exposed mandible bone surface. Temporary screws were fixed into the screw hole. An ultrasonic cutting instrument was used for the osteotomy. After separating the bone, a repositioning device was connected to the splint junction and bone segment, and repositioning was performed. At the time of repositioning, the registration marker was connected to the splint junction, and mandible repositioning was confirmed three-dimensionally through HoloLens 2 into the position specified in the virtual surgery. The rate of overlay error between the preoperative virtual operation and one-month postoperative CT data within 2 mm was 100%. CAD/CAM combined with MR enabled accurate genioplasty.

7.
Int J Implant Dent ; 9(1): 49, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38066306

RESUMO

OBJECTIVES: The objective was to investigate the details of the attachments of the mylohyoid muscle to the mandible anterior to the hyoid and mylohyoid lines to understand the positional relationship between the sublingual space and the mylohyoid, knowledge that is essential for dental implant surgery in the incisal region, as well as the routes of communication between the sublingual space and other spaces. METHODS: While evaluating the presence or absence of an anterior mylohyoid muscle fiber attachment to the mandible, sublingual gland herniation, spaces between muscle fascicles were also recorded as sites of penetration. The mean muscle thickness in each of these areas was also calculated. RESULTS: In all specimens, the mylohyoid originated not only from the mylohyoid line but also from the lingual surface of the center of the mandibular body (the mandibular symphysis) below the mental spines. The mylohyoid muscle fascicles were thickest in the posterior region, and further anterior to this, they tended to become thinner. Sublingual gland herniations passing through the mylohyoid were noted in the anterior and central regions, but not in the posterior region. Penetration between the muscle fascicles was most common in the central region, and no such penetration was evident in the posterior region. CONCLUSIONS: These results suggest that the mylohyoid functions only incompletely as a septum, and that routes of communication from the sublingual space to the submandibular space may be present in both the anterior and central muscle fascicles of the mylohyoid. Therefore, bleeding complications during dental implant placement in the anterior mandible can be serious issues. There is a potential for sublingual hematoma that could compromise the airway by pressing the tongue against the soft palate into the pharynx.


Assuntos
Implantes Dentários , Soalho Bucal/cirurgia , Músculos do Pescoço , Glândula Sublingual/cirurgia , Língua/cirurgia
8.
Diagnostics (Basel) ; 13(20)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37892057

RESUMO

Arch forms in orthodontics are considered to affect occlusal stability. This study's subjects were 47 patients (Class III S group) who visited the Chiba Dental Center of Tokyo Dental College and were surgical orthodontic cases, and 60 patients with Class I malocclusion were selected as the control group. A mandibular model of each subject was plotted with each tooth on a digitizer. The clinical bracket points of each tooth were plotted, and intercanine and intermolar measurements were taken. The least squares method was used to fit a quartic equation, and the arch form was drawn. The Class IIIS group was divided by Wits appraisal and facial pattern into a dolichofacial or brachyfacial pattern, and arch forms were compared. The results show that the Class IIIS group had a significantly smaller intermolar width, canine depth, and molar depth and a significantly larger canine W/D ratio. In those with a dolichofacial pattern, the anterior curve of the arch form tended to be flat and the posterior curve narrower. This is because, in skeletal mandibular prognathism, the mandibular anterior shows lingual tipping, and the molars show palatal tipping due to dental compensation, and it was inferred that this tendency was higher in high-angle cases.

9.
J Funct Biomater ; 14(8)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37623679

RESUMO

The objective of this study is to clarify the effect of restoring the lowered masticatory muscle functional pressure and correcting bilateral differences in masticatory muscle functional pressure on jawbone growth during growth and development with a quantitative evaluation of the changes in the micro/nanostructural characteristics of entheses. Male Wistar rats aged 4 weeks were divided into an experimental group injected with a botulinum toxin serotype A (BoNT/A) formulation to reduce muscle function (BTX group) and a control group (CTRL group). They were euthanised after 6, 8, 10, 12, and 16 weeks after measuring the difference between the midline of the upper and lower incisors. The mandibles were harvested for histological examination, second harmonic generation imaging, and the quantitative evaluation of biological apatite (BAp) crystal alignment. The midline difference decreased with age in weeks. In rats from 6 weeks after BoNT/A administration to 12 weeks after administration, the collagen fibre bundle diameter was significantly smaller in the BTX group; the difference between the two groups decreased with increasing age. BAp crystal alignment was significantly different on the x-axis and the y-axis on the BTX group from 6 weeks after BoNT/A administration to 10 weeks after administration. Asymmetry of mandibular bone formation caused by load imbalance during growth could be corrected by the adjustment of the function of the masseter muscle on either side.

10.
J Funct Biomater ; 14(7)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37504851

RESUMO

A lateral load was applied to anchor screws that had undergone surface treatment, and the structure, cellular dynamics, and quality of the bone surrounding anchor screws were analyzed to investigate the effect of this surface treatment on the peri-implant jawbone. In addition, bone microstructural characteristics were quantitatively evaluated for each site of loading on the bone around the anchor screw. Rats were euthanized after observation on days 3, 5, or 7, and bone quality analyses were performed. Bone-implant contact rate increased more rapidly at an early stage in the treated surface group than in the untreated surface group. Bone lacuna morphometry showed that the measured values adjacent to the screw at the screw neck on the compressed side (A) and at the screw tip on the uncompressed side (D) were significantly lower than those at the screw tip on the compressed side (B) and at the screw neck on the uncompressed side (C). Collagen fiber bundle diameter showed that the measured values adjacent to regions A and D were significantly higher than those at regions B and C. Anchor screw surface activation facilitates initial bone contact of the screw, suggesting that early loading may be possible in clinical practice.

11.
Dent Mater J ; 42(5): 633-640, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37423721

RESUMO

Titanium is a biocompatible material commonly used for dental treatments. However, the detailed mechanism underlying the weak biological activity of titanium has not been elucidated. We investigated both the inflammatory responses and T cell activation induced by solid titanium in the gingiva in mice. Both titanium and nickel wire implantation promoted neutrophil infiltration into the gingiva on day 2. Nickel, but not titanium, wire implantation enhanced proinflammatory cytokine expression and dendritic cell activity in gingival tissue by day 2. Nickel wire implantation enhanced the activity of T cells in draining lymph nodes on day 5. Moreover, T cell and neutrophil infiltration and elevated proinflammatory cytokine expression in the gingival tissue were still observed on day 5. However, no such augmented biological responses were observed after titanium wire implantation. These findings suggest that, unlike nickel, solid titanium does not induce sufficient inflammatory responses leading to T cell activation in gingival tissue.


Assuntos
Níquel , Titânio , Camundongos , Animais , Gengiva , Materiais Biocompatíveis , Teste de Materiais
13.
Dent Mater J ; 42(4): 542-551, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37225459

RESUMO

The purpose of this study is to investigate the effect of orthodontic anchor screws (OASs) inserted into the femur of growth-phase or mature rats using histological observation and bone structure analysis. The experimental animals are growth-phase (6-week-old) or mature (25-week-old) male Wistar rats. OAS was placed into the point one-third of the femoral length from the proximal end of the femur, and the response of the surrounding bone was observed and measured. The results showed at the OAS bone interface, in growth-phase rats, bone mineral density (BMD) was reduced and the running angle of collagen fiber bundles varied significantly. In mature rats, more osteoid was observed and biological apatite (BAp) crystals showed a different orientation. It was suggested that after the insertion of OASs, bone volume and quality are decreased, but after a sufficient healing period, a new bone micro/nano structure, different from the original structure, are reconstructed.


Assuntos
Apatitas , Densidade Óssea , Ratos , Masculino , Animais , Densidade Óssea/fisiologia , Apatitas/análise , Ratos Wistar , Fêmur/cirurgia , Fêmur/química , Fêmur/fisiologia , Parafusos Ósseos , Colágeno/análise
14.
J Prosthodont Res ; 67(4): 626-632, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37032073

RESUMO

PURPOSE: In this study, the fatigue properties of additively manufactured titanium clasps were compared with those of commercially pure titanium (CPTi) and Ti-6Al-4V (Ti64), manufactured using laser powder-bed fusion. METHODS: Fourteen specimens of each material were tested under the cyclic condition at 1 Hz with applied maximum strokes ranging from 0.2 to 0.5 mm, using a small stroke fatigue testing machine. A numerical approach using finite element analysis (FEA) was also developed to predict the fatigue life of the clasps. RESULTS: The results showed that although no significant differences were observed between the two materials when a stroke larger than 0.35 mm was applied, CPTi had a better fatigue life under a stroke smaller than 0.33 mm. The distributions of the maximum principal stress in the FEA and the fractured position in the experiment were in good agreement. CONCLUSIONS: Using a design of the clasp of the present study, the advantage of the CPTi clasp in its fatigue life under a stroke smaller than 0.33 mm was revealed experimentally. Furthermore, the numerical approach using FEA employing calibrated parameters for the Smith-Watson-Topper method are presented. Under the limitations of the aforementioned clasp design, the establishment of a numerical method enabled us to predict the fatigue life and ensure the quality of the design phase before manufacturing.


Assuntos
Ligas , Acidente Vascular Cerebral , Humanos , Titânio , Pós , Grampos Dentários , Lasers , Teste de Materiais
15.
Sci Rep ; 13(1): 3442, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859576

RESUMO

The lineage of periodontal ligament (PDL) stem cells contributes to alveolar bone (AB) and cementum formation, which are essential for tooth-jawbone attachment. Leptin receptor (LepR), a skeletal stem cell marker, is expressed in PDL; however, the stem cell capacity of LepR+ PDL cells remains unclear. We used a Cre/LoxP-based approach and detected LepR-cre-labeled cells in the perivascular around the root apex; their number increased with age. In the juvenile stage, LepR+ PDL cells differentiated into AB-embedded osteocytes rather than cementocytes, but their contribution to both increased with age. The frequency of LepR+ PDL cell-derived lineages in hard tissue was < 20% per total cells at 1-year-old. Similarly, LepR+ PDL cells differentiated into osteocytes following tooth extraction, but their frequency was < 9%. Additionally, both LepR+ and LepR- PDL cells demonstrated spheroid-forming capacity, which is an indicator of self-renewal. These results indicate that both LepR+ and LepR- PDL populations contributed to hard tissue formation. LepR- PDL cells increased the expression of LepR during spheroid formation, suggesting that the LepR- PDL cells may hierarchically sit upstream of LepR+ PDL cells. Collectively, the origin of hard tissue-forming cells in the PDL is heterogeneous, some of which express LepR.


Assuntos
Ligamento Periodontal , Receptores para Leptina , Células-Tronco , Diferenciação Celular , Células do Tecido Conjuntivo
17.
Maxillofac Plast Reconstr Surg ; 45(1): 1, 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36602618

RESUMO

BACKGROUND: Mesiodentes are the most common supernumerary teeth. The cause is not fully understood, although proliferations of genetic factors and the dental lamina have been implicated. Mesiodentes can cause delayed or ectopic eruption of permanent incisors, which can further alter occlusion and appearance. Careful attention should be paid to the position and direction of the mesiodentes because of possible damage to adjacent roots in the permanent dentition period, errant extraction in the deciduous and mixed dentition periods, and damage to the permanent tooth embryo. To avoid these complications, we applied mixed reality (MR) technology using the HoloLens® (Microsoft, California). In this study, we report on three cases of mesiodentes extraction under general anesthesia using MR technology. RESULTS: The patients ranged in age from 6 to 11 years, all three were boys, and the direction of eruption was inverted in all cases. The extraction approach was palatal in two cases and labial in one case. The average operative time was 32 min, and bleeding was minimal in all cases. No intraoperative or postoperative complications occurred. An image was shared preoperatively with all the surgeons using an actual situation model. Three surgeons used Microsoft HoloLens® during surgery, shared MR, and operated while superimposing the application image in the surgical field. CONCLUSIONS: The procedure was performed safely; further development of MR surgery support systems in the future is suggested.

18.
J Prosthodont Res ; 67(3): 460-467, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36403960

RESUMO

PURPOSE: This study investigates the effects of hollow structures, added by selective laser sintering (SLS), on the mechanical properties of a Co-Cr alloy for providing an optimal structural property to the framework components of removable partial dentures (RPDs). METHODS: The specimens produced using the 3D data of the dumbbell-shaped cylinders were divided into four groups based on the manufacturing method: Cast, Mill, SLS-solid, and SLS-hollow. Tensile tests were performed to measure the mechanical properties of the specimens. The mechanical property values among the four groups were statistically compared using the Kruskal-Wallis test followed by the Steel-Dwass test (α = 0.05). RESULTS: The median elastic modulus was the largest in the Cast, followed by SLS-solid, Mill, and SLS-hollow, with no significant differences observed between all conditions. The median ultimate tensile strength was the largest in the order of SLS-solid, Mill, SLS-hollow, and Cast. The median 0.2% proof stress was the largest in SLS-solid, followed by SLS-hollow, Cast, and Mill. The median elongation was the highest in the order of Mill, SLS-solid, SLS-hollow, and Cast. CONCLUSIONS: With the addition of hollow structures, the elastic modulus decreased while the mechanical strength and proof stress remained high in SLS specimens. In addition, the ISO 22674 standard for dental metals was met, suggesting that SLS may be a possible method to design RPD frameworks with high strength and optimal structural properties.


Assuntos
Ligas de Cromo , Lasers , Ligas de Cromo/química , Ligas Metalo-Cerâmicas/química , Resistência à Tração , Módulo de Elasticidade , Propriedades de Superfície , Teste de Materiais
19.
Odontology ; 111(3): 630-639, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36460825

RESUMO

The purpose of this study was to investigate the process and derivation of the distribution of the sensory nerves that appear in the extraction socket and surrounding alveolar bone following tooth extraction. The right mandibular first molar of rats and periodontal ligament were extracted as a single mass, and the mandible was harvested after days 1, 3, 5, and 7 after extraction. Serial sections of 7 µm thickness were prepared for the proximal root (Section A), buccolingual root (Section B), and centrifugal root (Section C) of the first molar. H-E staining and immunohistochemical staining with anti-S100 antibody and anti-NF-L antibody were carried out. The presence of nerve fiber bundles in the blood clot was already evident on post-extraction day 3, and on post-extraction day 7. On day 3, the number of axons in Sections B and C had greatly decreased, indicating that, after extraction, the connection between peripheral nerve tissue and the trigeminal ganglion was temporarily markedly reduced in the region of the alveolar branch. Although the myelin sheaths were regenerating on day 5, the majority of the axons of the alveolar branches extending from the inferior alveolar nerve were seen to be extremely thin and scattered, despite their further regeneration. The above results suggest that the newly myelinated nerves are actually derived from the bone marrow to the extraction socket, so few nerves, rather than being derived from the alveolar branches that had innervated the extracted tooth.


Assuntos
Bainha de Mielina , Ligamento Periodontal , Animais , Ratos , Axônios , Nervo Mandibular , Dente Molar
20.
Diagnostics (Basel) ; 14(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38201333

RESUMO

Facial asymmetry is often seen in patients with skeletal mandibular prognathism and is associated with deformities in the maxillofacial and head regions. The maxillofacial deviation is three-dimensional and affects not only the lateral deviation of the mandible and midface, but also the cranium. This study conducted a three-dimensional morphological evaluation of the cranial base morphology of patients with skeletal mandibular prognathism (ANB < 0°, Wits < 0 mm) with the aim of examining the relationship between deformities of the head region and facial asymmetry. Data obtained from computed tomography conducted during the initial examination of patients with and without skeletal mandibular prognathism with facial asymmetry were used. Differences in the position of structures present in the cranial base were measured, and the association between cranial deformities and mandibular deviation was assessed. The middle cranial base area and the lateral deviation of the mandibular fossa were significantly larger in patients with facial asymmetry compared to those without facial asymmetry. In addition, a correlation between the amount of mandibular deviation and the area of the anterior cranial base was identified in patients with significant cranial deformity (p = 0.012). Given the identified association between the structure of the head region and facial asymmetry, further studies are needed to determine the factors implicated in the growth process.

SELEÇÃO DE REFERÊNCIAS