Resultados 1 - 20 de 56
Filtrar
1.
Health Phys ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38394479

RESUMO

ABSTRACT: The exponential diffusion of wearable medical devices (WMD) in recent years has involved people of all ages, including workers. Workers who use WMDs should be considered at a particular risk from electromagnetic fields, and in accordance with EU Directive 2013/35/EU, they require an individual risk assessment. Currently, there is no international standard that provides specific guidance on how to perform such a risk assessment. This paper focuses on the effects of electromagnetic fields on WMDs and does not consider the direct effects on human body tissues. It aims to offer practical recommendations to employers and/or health physicists for the risk assessment of workers with WMDs. Focusing on EU countries, we first describe the requirements outlined by the technical standard for the electromagnetic compatibility (EMC) of medical electrical equipment EN 60601-1-2. Then, some general guidelines on how to perform the risk assessment are provided. The assessment can be conducted by comparing the field values measured in the workplace with the immunity test levels specified in the technical standards of medical electrical equipment. If the measured values are lower than the immunity test levels indicated in the standard and the distance from the electromagnetic source is greater than the distance used by the manufacturer during the EMC (electromagnetic compatibility) tests (typically 30 cm), the risk for the worker may be considered acceptable. However, if the measured values exceed the immunity test levels or the distance criteria, a specific evaluation based on a case-by-case analysis is required.

2.
Diagnostics (Basel) ; 13(18)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37761231

RESUMO

A 50-year-old Caucasian man arrived at the emergency department presenting paucisymptomatic atrial fibrillation. Once discharged after the appropriate treatments, the patient continued to have paucisymptomatic episodes. For this reason, he was provided with the Cardionica device which made it possible to better investigate the type of arrhythmic episodes, in order to tailor his therapy and to finally restore a normal sinus rhythm in the patient.

3.
Health Phys ; 125(3): 202-206, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37195187

RESUMO

ABSTRACT: Pacemakers (PM) and implantable cardioverter defibrillators (ICD) are active implantable medical devices (AIMD) needed in case of cardiac arrhythmias. Given their potentially life-sustaining nature, the interaction between any source of electromagnetic field and these AIMDs is an ongoing concern of patients, industry, and regulators. According to the current regulatory framework, the required immunity of PM and ICD provides a reasonable unperturbed behavior in the presence of cell phones and base stations that use pre-5G technologies. PM/ICD international standards do not consider some peculiar characteristics of 5G technology and some of the 5G technology frequency bands (those above 3 GHz), since these frequencies are considered not to add risks to the AIMD functioning. Here we analyze the theoretical issues about the interference between 5G technology and PM/ICD and propose an experimental approach to perform a measurement campaign.


Assuntos
Telefone Celular , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Campos Eletromagnéticos/efeitos adversos , Arritmias Cardíacas/terapia
4.
bioRxiv ; 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37034577

RESUMO

Cis-regulatory elements control gene expression and are dynamic in their structure, reflecting changes to the composition of diverse effector proteins over time1-3. Here we sought to connect the structural changes at cis-regulatory elements to alterations in cellular fate and function. To do this we developed PRINT, a computational method that uses deep learning to correct sequence bias in chromatin accessibility data and identifies multi-scale footprints of DNA-protein interactions. We find that multi-scale footprints enable more accurate inference of TF and nucleosome binding. Using PRINT with single-cell multi-omics, we discover wide-spread changes to the structure and function of candidate cis-regulatory elements (cCREs) across hematopoiesis, wherein nucleosomes slide, expose DNA for TF binding, and promote gene expression. Activity segmentation using the co-variance across cell states identifies "sub-cCREs" as modular cCRE subunits of regulatory DNA. We apply this single-cell and PRINT approach to characterize the age-associated alterations to cCREs within hematopoietic stem cells (HSCs). Remarkably, we find a spectrum of aging alterations among HSCs corresponding to a global gain of sub-cCRE activity while preserving cCRE accessibility. Collectively, we reveal the functional importance of cCRE structure across cell states, highlighting changes to gene regulation at single-cell and single-base-pair resolution.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36901531

RESUMO

Rapidly growing worldwide, 5G service is expected to deeply change the way we communicate, connect and share data. It encompasses the whole spectrum of new technology, infrastructure and mobile connectivity, and will touch not only every sector in the industry, but also many aspects of our everyday life. Although the compliance with international regulations provides reasonable protection to public health and safety, there might be specific issues not fully covered by the current technical standards. Among the aspects that shall be carefully considered, there is the potential interference that can be induced on medical devices, and in particular on implantable medical devices that are critical for the patient's life, such as pacemakers and implantable defibrillators. This study aims to assess the actual risk that 5G communication systems pose to pacemakers and implantable defibrillators. The setup proposed by the ISO 14117 standard was adapted to include 5G characteristic frequencies of 700 MHz and 3.6 GHz. A total number of 384 tests were conducted. Among them, 43 EMI events were observed. Collected results reveal that RF hand-held transmitters operating in these two frequency bands do not pose additional risk compared to pre-5G bands and that the safety distance of 15 cm typically indicted by the PM/ICD manufacturer is still able to guarantee the patient's safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
7.
Arch Public Health ; 80(1): 23, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35012667

RESUMO

BACKGROUND: Research networks offer multidisciplinary expertise and promote information exchange between researchers across Europe. They are essential for the European Union's (EU) health information system as providers of health information and data. The aim of this mapping exercise was to identify and analyze EU research networks in terms of health data collection methods, quality assessment, availability and accessibility procedures. METHODS: A web-based search was performed to identify EU research networks that are not part of international organizations (e.g., WHO-Europe, OECD) and are involved in collection of data for health monitoring or health system performance assessment. General characteristics of the research networks (e.g., data sources, representativeness), quality assessment procedures, availability and accessibility of health data were collected through an ad hoc extraction form. RESULTS: Fifty-seven research networks, representative at national, international or regional level, were identified. In these networks, data are mainly collected through administrative sources, health surveys and cohort studies. Over 70% of networks provide information on quality assessment of their data collection procedures. Most networks share macrodata through articles and reports, while microdata are available from ten networks. A request for data access is required by 14 networks, of which three apply a financial charge. Few networks share data with other research networks (8/49) or specify the metadata-reporting standards used for data description (9/49). CONCLUSIONS: Improving health information and availability of high quality data is a priority in Europe. Research networks could play a major role in tackling health data and information inequalities by enhancing quality, availability, and accessibility of health data and data sharing across European networks.

8.
Arch Public Health ; 80(1): 17, 2022 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-34986889

RESUMO

BACKGROUND: Health-related data are collected from a variety of sources for different purposes, including secondary use for population health monitoring (HM) and health system performance assessment (HSPA). Most of these data sources are not included in databases of international organizations (e.g., WHO, OECD, Eurostat), limiting their use for research activities and policy making. This study aims at identifying and describing collection methods, quality assessment procedures, availability and accessibility of health data across EU Member States (MS) for HM and HSPA. METHODS: A structured questionnaire was developed and administered through an online platform to partners of the InfAct consortium form EU MS to investigate data collections applied in HM and HSPA projects, as well as their methods and procedures. A descriptive analysis of the questionnaire results was performed. RESULTS: Information on 91 projects from 18 EU MS was collected. In these projects, data were mainly collected through administrative sources, population health interview or health examination surveys and from electronic medical records. Tools and methods used for data collection were mostly mandatory reports, self-administered questionnaires, or record linkage of various data sources. One-third of the projects shared data with EU research networks and less than one-third performed quality assessment of their data collection procedures using international standardized criteria. Macrodata were accessible via open access and reusable in 22 projects. Microdata were accessible upon specific request and reusable in 15 projects based on data usage licenses. Metadata was available for the majority of the projects, but followed reporting standards only in 29 projects. Overall, compliance to FAIR Data principles (Findable, Accessible, Interoperable, and Reusable) was not optimal across the EU projects. CONCLUSIONS: Data collection and exchange procedures differ across EU MS and research data are not always available, accessible, comparable or reusable for further research and evidence-based policy making. There is a need for an EU-level health information infrastructure and governance to promote and facilitate sharing and dissemination of standardized and comparable health data, following FAIR Data principles, across the EU.

9.
Pacing Clin Electrophysiol ; 45(3): 410-417, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35076120

RESUMO

BACKGROUND: Pacemaker (PM) and implantable cardioverter defibrillators (ICD) are equipped with a magnetic sensor activated by external application of magnets to easily manage some functions of these devices. If activated inadvertently or outside a controlled environment and without the supervision of clinical personnel, this magnetic mode introduces a potential risk. In reality, the possibility of a static magnetic field affecting a PM or ICD is remote. However, the presence of the magnet in the iPhone 12 made the possibility of inadvertently activating the magnetic switch of PM and ICD less remote. OBJECTIVE: This study investigates the effects of magnetic interference of the iPhone 12 on a large set of cardiac implantable devices representative of the current market and proposes adequate rules of conduct. METHODS: We investigated the risk of the magnetic interference of the iPhone 12 and its MagSafe accessories on a comprehensive set of PMs and ICDs, including the subcutaneous ICD. For the first time, the magnetic interference phenomena were correlated with the magnetic field levels measured all around iPhone 12. RESULTS: We discovered that the magnets inside iPhone 12 trigger the magnetic mode in the 12 tested devices up to a distance of 1 cm. CONCLUSIONS: Considering the implications related to the activation of the magnetic switch, to date, it is advisable to follow Apple's indications relating to the safety distance of 15 cm, which is widely compatible with the results obtained from this paper and in line with the indications provided by the implantable cardiac device manufacturers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Coração , Humanos , Imãs , Tecnologia
10.
Expert Rev Med Devices ; 18(12): 1203-1208, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34854774

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are widely used according to consensus guidelines in various patient categories. The longevity of CIED is a major determinant of the frequency with which patients require device replacement. Given the mismatch between the useful life of the devices and patient survival, device replacement is often needed. There is a great variability in the criteria used by manufacturers to determine the longevity of pacemakers (PM), implantable defibrillators (ICDs), and devices for cardiac resynchronization therapy (CRT). Thus, a fair comparison and an effective device evaluation is often difficult. METHODS: The objective of this paper is to provide standardized criteria based on typical clinical settings for estimating the longevity of single and dual chamber ICDs, cardiac resynchronization defibrillators (CRT-D), single and dual chamber PMs, and cardiac resynchronization PMs (CRT- P) to be used in health technology assessment for an appropriate comparison among different devices. RESULTS: The proposed parameters, if applied to the current marketed devices, provide longevity values in the range 5-17.2 years. CONCLUSION: The values of longevity with the non-standardized criteria used by the manufacturers result in higher maximum values respect to the proposed standardized criteria for CRT-D, CRTD-MPP, CRT-P, and Dual-chamber PM.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Dispositivos de Terapia de Ressincronização Cardíaca , Cardioversão Elétrica , Eletrônica , Humanos
11.
Artigo em Inglês | MEDLINE | ID: mdl-34574648

RESUMO

Workers with cardiac active implantable medical devices (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), are considered by the occupational health and safety regulation framework as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we first describe the general methodology that shall be followed for the risk assessment of employees with a cardiac AIMD exposed to EMF, according to the EU regulation, and in particular to the EN 50527-2-1:2016 and 50527-2-2:2018 standards. Then, three case studies related to specific EMF sources are presented, to better describe how the initial analysis of the risk assessment can be performed in practice, and to understand if a further specific risk assessment analysis is required or not.


Assuntos
Desfibriladores Implantáveis , Saúde Ocupacional , Marca-Passo Artificial , Campos Eletromagnéticos/efeitos adversos , Humanos , Medição de Risco
12.
MAGMA ; 34(4): 619-630, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33555489

RESUMO

OBJECTIVE: To propose and validate a variation of the classic techniques for the estimation of the transfer function (TF) of a real pacemaker (PM) lead. METHODS: The TF of three commercially available PM leads was measured by combining data from experimental measurements and numerical simulations generated by three sources: a) the experimental local SAR at the tip of the PM lead (single measurement point) exposed to a 64 MHz birdcage body coil; b) the experimental current distribution along the PM lead, obtained by directly injecting a 64 MHz signal inside the lead; c) the electric field (E-field) simulated with a computational model of the 64 MHz birdcage body coil adopted in the experimental measurement performed in a). The effect of the lead trajectory on the estimation of the TF was also estimated. RESULTS: The proposed methodology was validated by comparing the SAR obtained from the PM lead TF with experimental measurements: a maximum difference of 2.2 dB was observed. It was also shown that the estimation of the TF cannot be considered independent with the lead trajectory: a variation of the SAR estimation up to 3.4 dB was observed. CONCLUSION: For the three PM lead tested, the error in the SAR estimation is within the uncertainty level of SAR measurements (± 2 dB). Additionally, the estimation of the TF using the reciprocity principle is influenced by the particular lead trajectory adopted, even if the consequent variability in the SAR estimation is still close to the uncertainty level of SAR measurements.


Assuntos
Calefação , Marca-Passo Artificial , Temperatura Alta , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ondas de Rádio
13.
Health Phys ; 120(3): 344-349, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33086265

RESUMO

ABSTRACT: In 2017, the Italian National Institute of Health conducted a study to evaluate the potential risks of Conducted Electrical Weapons (CEW, AKA "stun guns") for users bearing a pacemaker (PM) or an implantable cardioverter defibrillator (ICD). The study addressed two specific models of stun guns: the TASER model X2 and AXON model X26P. In 2019, the same experimental protocol and testing procedure was adopted to evaluate the risk for another model of stun gun, the MAGEN model 5 (MAGEN, Israel). The MAGEN 5 differs from the previous stun guns tested in terms of peak voltage generated, duration of the shock, and trigger modality for repeated shocks. This note is an update of the previous study results, including the measurements on the MAGEN 5 stun gun. Despite the differences between the stun gun models, the effects on the PM/ICD behavior were the same as previously observed for the TASER stun guns.


Assuntos
Desfibriladores Implantáveis , Terapia por Estimulação Elétrica , Marca-Passo Artificial , Humanos
14.
G Ital Med Lav Ergon ; 41(4): 280-284, 2019 12.
Artigo em Italiano | MEDLINE | ID: mdl-32126594

RESUMO

SUMMARY: Purpose. The work illustrates useful elements for the risk assessment for workers exposed to electromagnetic fields, also in reference to sensitive subjects such as those with active implantable medical devices (AIMD). Methods. The approach introduced by Legislative Decree 81/08 for risk assessment does not explicitly include operational criteria and specific measures for the protection of sensitive subjects. In the case of workers with DMIA, the employer may refer to relevant harmonized technical standards. Results. They are shown the results of in vitro tests performed on pacemakers following the indications of the technical reference standard and employing sources of electromagnetic fields that, due to the type of signal emitted, do not allow to exclude an a priori influence on the operation of the device. Conclusions. Workers at particular risk are generally protected if the requirements established for the population are respected. This measure may, under certain conditions, not be sufficient,making it necessary to carry out more in-depth and individual assessments. However, the cases illustrated here for AIMD showed interference phenomena only in limited experimental configurations despite the levels of the electric and magnetic fields generated by the sources exceeding the limits for the general population.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Exposição Ocupacional/prevenção & controle , Medição de Risco/métodos , Falha de Equipamento , Humanos , Saúde Ocupacional , Marca-Passo Artificial , Próteses e Implantes
15.
Health Phys ; 116(1): 18-26, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30489364

RESUMO

The aim of the study is to investigate systematically the possible interactions between two types of stun guns and last-generation pacemakers and implantable defibrillators. Experimental measurements were performed on pacemakers and implantable defibrillators from five leading manufacturers, considering the effect of stun gun dart positioning, sensing modality, stun gun shock duration, and defibrillation energy level. More than 300 measurements were collected. No damage or permanent malfunction was observed in either pacemakers or implantable defibrillators. During the stun gun shock, most of the pacemakers entered into the noise reversion mode. However, complete inhibition of the pacing activity was also observed in some of the pacemakers and in all the implantable defibrillators. In implantable defibrillators, standard stun gun shock (duration 5 s) caused the detection of a shockable rhythm and the start of a charging cycle. Prolonged stun gun shocks (10-15 s) triggered the inappropriate delivery of defibrillation therapy in all the implantable defibrillators tested. Also in this case, no damage or permanent malfunction was observed. For pacemakers, in most cases, the stun guns caused them either to switch to the noise reversion mode or to exhibit partial or total pacing inhibition. For implantable defibrillators, in all cases, the stun guns triggered a ventricular fibrillation event detection. No risks resulted when the stun gun was used by a person wearing a pacemaker or an implantable defibrillator. This work provides novel and up-to-date evidence useful for the evaluation of risks to pacemaker/implantable defibrillator wearers due to stun guns.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Humanos
16.
Mol Cell ; 73(2): 291-303.e6, 2019 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-30527661

RESUMO

In Drosophila, 23-30 nt long PIWI-interacting RNAs (piRNAs) direct the protein Piwi to silence germline transposon transcription. Most germline piRNAs derive from dual-strand piRNA clusters, heterochromatic transposon graveyards that are transcribed from both genomic strands. These piRNA sources are marked by the heterochromatin protein 1 homolog Rhino (Rhi), which facilitates their promoter-independent transcription, suppresses splicing, and inhibits transcriptional termination. Here, we report that the protein Maelstrom (Mael) represses canonical, promoter-dependent transcription in dual-strand clusters, allowing Rhi to initiate piRNA precursor transcription. Mael also represses promoter-dependent transcription at sites outside clusters. At some loci, Mael repression requires the piRNA pathway, while at others, piRNAs play no role. We propose that by repressing canonical transcription of individual transposon mRNAs, Mael helps Rhi drive non-canonical transcription of piRNA precursors without generating mRNAs encoding transposon proteins.


Assuntos
Elementos de DNA Transponíveis , Proteínas de Drosophila/metabolismo , Drosophila melanogaster/enzimologia , RNA Polimerase II/metabolismo , RNA Guia de Cinetoplastídeos/biossíntese , RNA Mensageiro/biossíntese , RNA Interferente Pequeno/biossíntese , Transcrição Gênica , Animais , Proteínas Argonautas/genética , Proteínas Argonautas/metabolismo , Sítios de Ligação , Proteínas Cromossômicas não Histona/genética , Proteínas Cromossômicas não Histona/metabolismo , Proteínas de Drosophila/genética , Drosophila melanogaster/genética , Regulação da Expressão Gênica , Regiões Promotoras Genéticas , Ligação Proteica , RNA Helicases/genética , RNA Helicases/metabolismo , RNA Polimerase II/genética , RNA Guia de Cinetoplastídeos/genética , RNA Mensageiro/genética , RNA Interferente Pequeno/genética
17.
Science ; 362(6420)2018 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-30545857

RESUMO

Despite progress in defining genetic risk for psychiatric disorders, their molecular mechanisms remain elusive. Addressing this, the PsychENCODE Consortium has generated a comprehensive online resource for the adult brain across 1866 individuals. The PsychENCODE resource contains ~79,000 brain-active enhancers, sets of Hi-C linkages, and topologically associating domains; single-cell expression profiles for many cell types; expression quantitative-trait loci (QTLs); and further QTLs associated with chromatin, splicing, and cell-type proportions. Integration shows that varying cell-type proportions largely account for the cross-population variation in expression (with >88% reconstruction accuracy). It also allows building of a gene regulatory network, linking genome-wide association study variants to genes (e.g., 321 for schizophrenia). We embed this network into an interpretable deep-learning model, which improves disease prediction by ~6-fold versus polygenic risk scores and identifies key genes and pathways in psychiatric disorders.


Assuntos
Encéfalo/metabolismo , Regulação da Expressão Gênica , Transtornos Mentais/genética , Conjuntos de Dados como Assunto , Aprendizado Profundo , Elementos Facilitadores Genéticos , Epigênese Genética , Epigenômica , Redes Reguladoras de Genes , Estudo de Associação Genômica Ampla , Humanos , Locos de Características Quantitativas , Análise de Célula Única , Transcriptoma
18.
Nat Neurosci ; 21(8): 1126-1136, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30038276

RESUMO

Risk variants for schizophrenia affect more than 100 genomic loci, yet cell- and tissue-specific roles underlying disease liability remain poorly characterized. We have generated for two cortical areas implicated in psychosis, the dorsolateral prefrontal cortex and anterior cingulate cortex, 157 reference maps from neuronal, neuron-depleted and bulk tissue chromatin for two histone marks associated with active promoters and enhancers, H3-trimethyl-Lys4 (H3K4me3) and H3-acetyl-Lys27 (H3K27ac). Differences between neuronal and neuron-depleted chromatin states were the major axis of variation in histone modification profiles, followed by substantial variability across subjects and cortical areas. Thousands of significant histone quantitative trait loci were identified in neuronal and neuron-depleted samples. Risk variants for schizophrenia, depressive symptoms and neuroticism were significantly over-represented in neuronal H3K4me3 and H3K27ac landscapes. Our Resource, sponsored by PsychENCODE and CommonMind, highlights the critical role of cell-type-specific signatures at regulatory and disease-associated noncoding sequences in the human frontal lobe.


Assuntos
Epigênese Genética/genética , Lobo Frontal/metabolismo , Lobo Frontal/patologia , Histonas/genética , Esquizofrenia/genética , Esquizofrenia/metabolismo , Doença de Alzheimer/genética , Mapeamento Encefálico , Cromatina/genética , Depressão/genética , Depressão/patologia , Escolaridade , Predisposição Genética para Doença/genética , Variação Genética , Estudo de Associação Genômica Ampla , Giro do Cíngulo/patologia , Humanos , Transtornos Neuróticos/genética , Transtornos Neuróticos/patologia , Córtex Pré-Frontal/patologia , Risco
19.
Psychosom Med ; 80(9): 845-852, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29595708

RESUMO

OBJECTIVE: High blood pressure (BP) is associated with reduced pain sensitivity, known as BP-related hypoalgesia. The underlying neural mechanisms remain uncertain, yet arterial baroreceptor signaling, occurring at cardiac systole, is implicated. We examined normotensives using functional neuroimaging and pain stimulation during distinct phases of the cardiac cycle to test the hypothesized neural mediation of baroreceptor-induced attenuation of pain. METHODS: Eighteen participants (10 women; 32.7 (6.5) years) underwent BP monitoring for 1 week at home, and individual pain thresholds were determined in the laboratory. Subsequently, participants were administered unpredictable painful and nonpainful electrocutaneous shocks (stimulus type), timed to occur either at systole or at diastole (cardiac phase) in an event-related design. After each trial, participants evaluated their subjective experience. RESULTS: Subjective pain was lower for painful stimuli administered at systole compared with diastole, F(1, 2283) = 4.82, p = 0.03. Individuals with higher baseline BP demonstrated overall lower pain perception, F(1, 2164) = 10.47, p < .0001. Within the brain, painful stimulation activated somatosensory areas, prefrontal cortex, cingulate cortex, posterior insula, amygdala, and the thalamus. Stimuli delivered during systole (concurrent with baroreceptor discharge) activated areas associated with heightened parasympathetic drive. No stimulus type by cardiac phase interaction emerged except for a small cluster located in the right parietal cortex. CONCLUSIONS: We confirm the negative associations between BP and pain, highlighting the antinociceptive impact of baroreceptor discharge. Neural substrates associated with baroreceptor/BP-related hypoalgesia include superior parietal lobule, precentral, and lingual gyrus, regions typically involved in the cognitive aspects of pain experience.


Assuntos
Pressão Sanguínea/fisiologia , Encéfalo/fisiologia , Diástole/fisiologia , Percepção da Dor/fisiologia , Pressorreceptores/fisiologia , Sístole/fisiologia , Adulto , Encéfalo/diagnóstico por imagem , Estimulação Elétrica , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Adulto Jovem
20.
Cortex ; 99: 200-212, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29253783

RESUMO

Information processing, particularly of salient emotional stimuli, is influenced by cardiovascular afferent signals. Carotid baroreceptors signal the state of cardiovascular arousal to the brain, controlling blood pressure and heart rate via the baroreflex. Animal studies suggest a lateralization of this effect: Experimental stimulation of the right carotid sinus has a greater impact on heart rate when compared to left-sided stimulation. We tested, in humans, whether the processing of emotional information from faces was differentially affected by right versus left carotid afferents. To achieve so, we used an automated neck suction device to stimulate the carotid mechanoreceptors in the carotid sinus (parasympathetic pathway) synchronously with functional magnetic resonance imaging (fMRI) acquisition whilst participants were engaged in an emotional rating task of fearful and neutral faces. We showed that both right and left carotid stimulation (CS) influenced brain activity within opercular regions, although a stronger activation was observed within left insula during right stimulation compared to left stimulation. As regards the processing of fearful faces, right, but not left carotid stimulation attenuated the perceived intensity of fear, and (albeit to a lesser extent) enhanced intensity ratings of neutral faces. Mirroring the behavioural effects, there was a significant expression-by-stimulation interaction for right carotid stimulation only, when bilateral amygdala responses were attenuated to fear faces and amplified to neutral faces. Individual differences in basal heart rate variability (HRV) predicted the extent to which right carotid stimulation attenuated amygdala responses during fear processing. Our study provides unique evidence for lateralized viscerosensory effects on brain systems supporting emotional processing.


Assuntos
Tonsila do Cerebelo/fisiologia , Seio Carotídeo , Córtex Cerebral/fisiologia , Medo/fisiologia , Pressorreceptores/fisiologia , Adulto , Tonsila do Cerebelo/diagnóstico por imagem , Barorreflexo , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Córtex Cerebral/diagnóstico por imagem , Emoções/fisiologia , Feminino , Lateralidade Funcional , Neuroimagem Funcional , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Adulto Jovem