1.
Sensors (Basel) ; 24(6)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38544164

RESUMO

Millimeter-wave (mmWave) radars attain high resolution without compromising privacy while being unaffected by environmental factors such as rain, dust, and fog. This study explores the challenges of using mmWave radars for the simultaneous detection of people and small animals, a critical concern in applications like indoor wireless energy transfer systems. This work proposes innovative methodologies for enhancing detection accuracy and overcoming the inherent difficulties posed by differences in target size and volume. In particular, we explore two distinct positioning scenarios that involve up to four mmWave radars in an indoor environment to detect and track both humans and small animals. We compare the outcomes achieved through the implementation of three distinct data-fusion methods. It was shown that using a single radar without the application of a tracking algorithm resulted in a sensitivity of 46.1%. However, this sensitivity significantly increased to 97.10% upon utilizing four radars using with the optimal fusion method and tracking. This improvement highlights the effectiveness of employing multiple radars together with data fusion techniques, significantly enhancing sensitivity and reliability in target detection.


Assuntos
Algoritmos , Privacidade , Animais , Humanos , Reprodutibilidade dos Testes , Transferência de Energia , Radar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA