RESUMO
PURPOSE: Unstructured, free-text dictation (FT), the current standard in breast magnetic resonance imaging (MRI) reporting, is considered time-consuming and prone to error. The purpose of this study is to assess the usability and performance of a novel, software-based guided reporting (GR) strategy in breast MRI. METHODS: Eighty examinations previously evaluated for a clinical indication (e.g., mass and focus/non-mass enhancement) with FT were reevaluated by three specialized radiologists using GR. Each radiologist had a different number of cases (R1, n = 24; R2, n = 20; R3, n = 36). Usability was assessed by subjective feedback, and quality was assessed by comparing the completeness of automatically generated GR reports with that of their FT counterparts. Errors in GR were categorized and analyzed for debugging with a final software version. Combined reading and reporting times and learning curves were analyzed. RESULTS: Usability was rated high by all readers. No non-sense, omission/commission, or translational errors were detected with the GR method. Spelling and grammar errors were observed in 3/80 patient reports (3.8%) with GR (exclusively in the discussion section) and in 36/80 patient reports (45%) with FT. Between FT and GR, 41 patient reports revealed no content differences, 33 revealed minor differences, and 6 revealed major differences that resulted in changes in treatment. The errors in all patient reports with major content differences were categorized as content omission errors caused by improper software operation (n = 2) or by missing content in software v. 0.8 displayable with v. 1.7 (n = 4). The mean combined reading and reporting time was 576 s (standard deviation: 327 s; min: 155 s; max: 1,517 s). The mean times for each reader were 485, 557, and 754 s, and the respective learning curves evaluated by regression models revealed statistically significant slopes (P = 0.002; P = 0.0002; P < 0.0001). Overall times were shorter compared with external references that used FT. The mean combined reading and reporting time of MRI examinations using FT was 1,043 s and decreased by 44.8% with GR. CONCLUSION: GR allows for complete reporting with minimized error rates and reduced combined reading and reporting times. The streamlining of the process (evidenced by lower reading times) for the readers in this study proves that GR can be learned quickly. Reducing reporting errors leads to fewer therapeutic faults and lawsuits against radiologists. It is known that delays in radiology reporting hinder early treatment and lead to poorer patient outcomes. CLINICAL SIGNIFICANCE: While the number of scans and images per examination is continuously rising, staff shortages create a bottleneck in radiology departments. The IT-based GR method can be a major boon, improving radiologist efficiency, report quality, and the quality of simultaneously generated data.
RESUMO
The Operationalized Psychodynamic Diagnostic of Children and Adolescents (OPD-KJ-2) in Everyday Clinical Practice with the Plämobox: Applicability and Interrater Reliability Abstract: Objective: The OPD-CA2 manual for assessing psychodynamic aspects in children and adolescents is well established in clinical practice. However, publications regarding its reliability and validity are limited to (1) adolescents, (2) the structure of the first version of the manual and not to the comprehensive revision of the OPD-CA2, (3) the axes "structure" and (partly) "conflict" but not the axis "relationship," and (4) missing applicability in everyday clinical practice. Methodology: The present study comprised 42 children aged 6-12 years (age level 2 of the OPD-CA2), with and without mental illness, and assessed them using two randomly assigned raters. We assessed them using a low-structured diagnostic symbol game with miniature figurines and objects based on videotapes. We also tested the interrater reliability of the OPD-CA2 axes. Results: The overall assessment of structure and the assessment of the four subdimensions succeeded with good to very good agreement. We could also determine the presence of relevant conflict dynamics with very high agreement, while not recognizing specific conflicts in the clinical sample. Our assessment of the items of the relationship axis shows a low level of agreement. Conclusions: Overall, we can confirm the reliability of the OPD-CA2 for everyday clinical assessment in the younger age groups. Finally, we discuss which factors contribute to the heterogeneous picture.
Assuntos
Transtornos Mentais , Variações Dependentes do Observador , Psicometria , Humanos , Criança , Masculino , Feminino , Reprodutibilidade dos Testes , Psicometria/estatística & dados numéricos , Transtornos Mentais/diagnóstico , Transtornos Mentais/psicologia , Adolescente , Manuais como Assunto , Determinação da Personalidade/estatística & dados numéricos , Conflito Psicológico , Terapia PsicanalíticaRESUMO
Background & Aims: Spontaneous portosystemic shunts (SPSS) develop frequently in cirrhosis. Changes over time and the effect of aetiological interventions on SPSS are unknown, so we aimed to explore the effect of these variables on SPSS evolution. Methods: Patients with cirrhosis from the Baveno VI-SPSS cohort were selected provided a follow-up abdominal CT or MRI scan was available. Clinical and laboratory data were collected at baseline and follow-up. Imaging tests were reviewed to evaluate changes in the presence and size of SPSS (large (L)-SPSS was ≥8 mm) over time. Regarding alcohol- or HCV-related cirrhosis, two populations were defined: cured patients (abstinent from alcohol or successful HCV therapy), and non-cured patients. Results: A total of 617 patients were included. At baseline SPSS distribution was 22% L-SPSS, 30% small (S)-SPSS, and 48% without (W)-SPSS. During follow-up (median follow-up of 63 months), SPSS distribution worsened: L-SPSS 26%, S-SPSS 32%, and W-SPSS 42% (p <0.001). Patients with worse liver function during follow-up showed a simultaneous aggravation in SPSS distribution. Non-cured patients (n = 191) experienced a significant worsening in liver function, more episodes of liver decompensation and lower transplant-free survival compared to cured patients (n = 191). However, no differences were observed regarding SPSS distribution at inclusion and at follow-up, with both groups showing a trend to worsening. Total shunt diameter increased more in non-cured (52%) than in cured patients (28%). However, total shunt area (TSA) significantly increased only in non-cured patients (74 to 122 mm2, p <0.001). Conclusions: The presence of SPSS in cirrhosis increases over time and parallels liver function deterioration. Aetiological intervention in these patients reduces liver-related complications, but SPSS persist although progression is decreased. Impact and implications: There is no information regarding the evolution of spontaneous portosystemic shunts (SPSS) during the course of cirrhosis, and especially after disease regression with aetiological interventions, such as HCV treatment with direct-acting antivirals or alcohol abstinence. These results are relevant for clinicians dealing with patients with cirrhosis and portal hypertension because they have important implications for the management of cirrhosis with SPSS after disease regression. From a practical point of view, physicians should be aware that in advanced cirrhosis with portal hypertension, after aetiological intervention, SPSS mostly persist despite liver function improvement, and complications related to SPSS may still develop.
RESUMO
INTRODUCTION: Recurrence after curative resection of hepatic alveolar echinococcosis remains a clinical challenge. The current study tested if assessment of anti-recEm18 allows for postsurgical patient surveillance. METHODS: A retrospective study with patients undergoing liver resection for alveolar echinococcosis (n = 88) at the University Hospital Bern from 2002 to 2020 and at the University Hospital and Medical Center Ulm from 2011 to 2017 was performed. Analysis was directed to determine a potential association of pre- and postoperative values of anti-recEm18 with clinical outcomes. RESULTS: Anti-recEm18 had a linear correlation to the maximum lesion diameter (R2 = 0.558). Three trajectories of anti-recEm18 were identified based on a threshold of 10 AU/ml: "Em18-low" (n = 31), "responders" (n = 53) and "residual disease" (n = 4). The decline of anti-recEm18 in "responders" reached a plateau after 10.9 months at which levels decreased by 90%. The only patient with recurrence in the entire population was also the only patient with a secondary increase of anti-recEm18. CONCLUSION: In patients with preoperative elevated values, anti-recEm18 confirms curative surgery at 12 months follow-up and allows for long-term surveillance.
Assuntos
Equinococose Hepática , Equinococose , Humanos , Equinococose Hepática/cirurgia , Estudos Retrospectivos , Seguimentos , Equinococose/cirurgia , Hepatectomia/efeitos adversosRESUMO
PURPOSE: To obtain initial data on sentinel lymph node (SLN) visualisation by pre-operative magnetic resonance imaging (MRI) and intra-operative bimodal SLN identification using a new magnetic fluorescent hybrid tracer in prostate cancer (PCa) patients. METHODS: Ten patients at > 5% risk for lymph node (LN) invasion were included. The day before surgery, a magnetic fluorescent hybrid tracer consisting of superparamagnetic iron oxide nanoparticles (SPION) and indocyanine green was transrectally injected into the prostate. Five hours after injection, transversal pelvic MRI scans were recorded and T2*-weighed images were screened for pelvic LNs with SPION uptake. Intra-operatively, magnetically active and/or fluorescent SLNs were detected by a handheld magnetometer and near-infrared fluorescence imaging (FI). Extended pelvic lymph node dissection (PLND) and radical prostatectomy completed the surgery. All resected specimens were checked ex situ for magnetic activity and fluorescence and were histopathologically examined. RESULTS: Pre-operative MRI identified 145 pelvic LNs with SPION uptake. In total, 75 (median 6, range 3â13) magnetically active SLNs were resected, including 14 SLNs not seen on MRI. FI identified 89 fluorescent LNs (median 8.5, range 4â13) of which 15 LNs were not magnetically active. Concordance of the different techniques was 70% for pre-operative MRI vs. magnetometer-guided PLND and 88% for magnetic vs. fluorescent SLN detection. CONCLUSION: These are the first promising results of bimodal, magnetic fluorescent SLN detection in PCa patients. Our magnetic fluorescent hybrid approach provides the surgeon a pre-operative lymphatic roadmap by using MRI and intra-operative visual guidance through the application of a fluorescent lymphatic agent. The diagnostic accuracy of our new hybrid approach has to be evaluated in further studies. TRIAL REGISTRATION: DRKS00032808. Registered 04 October 2023, retrospectively registered.
RESUMO
Background: Transarterial chemoembolization (TACE) is the accepted therapy for intermediate hepatocellular carcinoma (HCC). Although recent data suggests that bland transarterial embolization (TAE) is equally effective in intermediate HCC, not much is known about the efficacy in very early and early HCC not amenable for ablation or resection. We aimed to compare the outcome of patients with very early and early HCC treated by drug-eluting beads TACE (DEB-TACE), a specific technique of TACE using DC beads, and TAE using microparticles with a size of 100 µm up to 700 µm. Methods: Clinical data of totally 95 patients with very early and early HCC not amenable for surgery or ablation, treated between 2009 and 2019 at the Department of Visceral Surgery and Medicine and the Interdisciplinary Center of Vascular Interventions, University Hospital Bern, Switzerland, were retrospectively analyzed (52 patients in DEB-TACE and 42 patients in TAE group, respectively). All images were assessed using the modified Response Evaluation Criteria in Solid Tumors (mRECIST). Primary endpoint was overall survival (OS). Secondary endpoints were local response rate and time to local progression. Results: Most patients presented with Child-Pugh A. Thrombocytes were significantly lower in patients treated by TAE. Minor side effects occurred equally in both groups. No differences were detected in terms of OS, local tumor recurrence and response rate. Conclusions: Compared with DEB-TACE, TAE is an equally effective and save therapy for very early and early HCC not amenable for resection or ablation without differences in local tumor control and OS.
RESUMO
BACKGROUND AND AIMS: Frailty is frequent in cirrhosis and associated with skeletal muscle abnormalities and worse prognosis. 2D shear-wave elastography (2D-SWE) could mirror biomechanical properties of skeletal muscle reflecting muscle quality. However, there is no data on 2D-SWE on skeletal muscle stiffness assessment in cirrhosis and on frailty. METHODS: Outpatients with cirrhosis were prospectively included in a single center. Skeletal muscle stiffness was studied at the rectus femoris by 2D-SWE. Ileo-psoas area and index (area/height2), and antero-posterior diameter of rectus femoris (RF) was measured on ultrasound. RESULTS: We included 44 patients (24 male, age 59 [IQR 49-66]) with a median liver frailty index (LFI) of 3.7 (IQR 3.2-4.0). Measurement of RF muscle stiffness (RFMS) was feasible in all with high inter-measurement reproducibility. RFMS did not correlate with LFI, liver function and skeletal muscle diameters. Ileo-psoas index was lower in frail patients (1.7 vs 1.0 cm2/m2, p = 0.024). RF antero-posterior diameter inversely correlated with LFI (r -0.578: p<0.001). CONCLUSION: RFMS by 2D-SWE is feasible and reproducible in cirrhosis and is independent of liver function and LFI, and warrants further studies in this setting. RF antero-posterior diameter could be reported as an objective parameter mirroring sarcopenia and frailty.
Assuntos
Técnicas de Imagem por Elasticidade , Fragilidade , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Músculo Quadríceps , Reprodutibilidade dos Testes , Estudos de Viabilidade , Cirrose Hepática/complicações , Fígado/patologiaRESUMO
Introduction: Liver grafts with limited steatosis are currently used for liver transplantation, but the natural history of graft steatosis is not well known. Project Aims or Questions: This program evaluation aimed at assessing changes of steatosis after liver transplantation. Design: A retrospective chart review was performed assessing presence and severity of steatosis in the liver explant and in time zero donor graft biopsies carried out at the time-point of liver transplantation on histopathology and on imaging one year thereafter in 30 well characterized patients. Results: Ten patients (33%) showed steatosis on explant. Time zero biopsy revealed steatosis in 18 grafts (60%) and no steatosis in 12 (40%). One year after transplantation, 8 patients (27%) had steatosis and 22 patients (63%) had none. Fourteen patients (47%) showed changes in steatosis: 12 showed resolution and 2 showed de novo steatosis. Explant macrovesicular steatosis was associated with presence of steatosis 1 year after transplantation (binary logistic regression model, p = 0.014), but not macrovesicular steatosis in the donor graft at time-point of transplantation. Conclusion: Resolution of graft steatosis was frequent. Presence of steatosis in the recipient's liver, but not graft steatosis, was a risk factor for steatosis 1 year after transplantation. Factors related to the recipient seem to prevail over donor-related factors in determining the persistence or de novo appearance of steatosis after liver transplantation.
Assuntos
Fígado Gorduroso , Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Estudos Retrospectivos , Fígado Gorduroso/patologia , Fígado/diagnóstico por imagem , Doadores de Tecidos , Biópsia , Sobrevivência de EnxertoRESUMO
We report the finding of two copy number variants (CNVs) in a 12-year-old boy presenting both with autism spectrum disorder (ASD) and attention deficit/hyperactivity disorder (ADHD). Clinical features included aggressive behavior, mood instability, suicidal statements, repetitive and restrictive behavior, sensitivity to noise, learning problems and dyslexia, though no intellectual disability was present. Using array-based comparative genomic hybridization (array-CGH), we identified two CNVs, both triplex duplications of 324 kb on 3p26.3, and 284 kb on 4q13.1, respectively. One of the CNVs is located on chromosome 4q13.1 in the region of the gene encoding for adhesion G protein-coupled receptor L3 (ADGRL3, former name: latrophilin-3, LPHN3), the other on chromosome 3p26.3 in the region of the two pseudogenes AC090043.1 and RPL23AP39. The patient described in the present study showed increased symptoms under methylphenidate treatment but responded positively to 3 mg per day of the atypical neuroleptic drug aripiprazole. To our knowledge, this is the first report of a CNV in the ADGRL3 gene and its first association with ASD in humans.
RESUMO
OBJECTIVE: The aim of the study was to use a software application to analyze the examination times and changeover times of two clinically highly applied MRI scanners at a university hospital for radiology and to evaluate whether this could result in optimization potential for examination planning in the daily clinical routine of MRI diagnostics. MATERIALS AND METHODS: Based on the newly developed software application "Teamplay Usage" (Siemens Healthineers, Germany), the examinations carried out on two MRI scanners (1.5âT and 3âT) were investigated within an analysis period of 12 months with regard to the type of examination and its duration. In addition, compliance with the previously defined planning time (30, 45, 60âmin.) was checked and deviations were analyzed. In addition, the changeover times between the examinations were determined and a possible influence due to the exchange of MRI coils was investigated for a selection of change combinations. RESULTS: For the total of 7184 (1.5âT: 3740; 3âT: 3444) examinations included in the study, the median examination time was 43:02 minutes (1.5âT: 43:17âmin.; 3âT: 42:45âmin.). The ten most frequent types of examinations per MRI scanner were completed within the predefined plan time of 54.5â% (1.5âT) and 51.9â% (3âT), taking into account a previously defined preparation and post-processing time of 9 minutes per examination. Overall, more time was spent on examinations with a planned time of 30 minutes, whereas the majority of the examinations planned with 45 minutes were also completed within this time. Examinations with a planned time of 60 minutes usually took less time. A comparison between the planned time and the determined examination duration of the most common types of examinations showed overall a slight potential for optimization. Coil exchanges between two examinations had a small, but statistically not significant effect on the median changeover time (pâ=â0.062). CONCLUSION: Utilizing a software-based analysis, a detailed overview of the type of examination, examination duration, and changeover times of frequently used clinical MRI scanners could be obtained. In the clinic examined, there was little potential for optimization of examination planning. An exchange of MRI coils necessary for different types of examination only had a small effect on the changeover times. KEY POINTS: · The use of the "Teamplay Usage" software application enables a comprehensive overview of the type of examination, examination duration, and changeover times for MRI scanners.. · Adjustments to examination planning for MRI diagnostics show optimization potential, which, however, is to be assessed as low in the clinic examined.. · Necessary replacements of MRI coils only have a small effect on the changeover times.. CITATION FORMAT: · Meyl TP, Berghöfer A, Blatter T etâal. Software-Based Evaluation of Optimization Potential for Clinical MRI Scanners in Radiology. Fortschr Röntgenstr 2022; 194: 391â-â399.
Assuntos
Imageamento por Ressonância Magnética , Radiologia , Hospitais Universitários , Humanos , Radiografia , SoftwareRESUMO
The photoelectron circular dichroism (PECD) of the O 1s-photoelectrons of trifluoromethyloxirane (TFMOx) is studied experimentally and theoretically for different photoelectron kinetic energies. The experiments were performed employing circularly polarized synchrotron radiation and coincident electron and fragment ion detection using cold target recoil ion momentum spectroscopy. The corresponding calculations were performed by means of the single center method within the relaxed-core Hartree-Fock approximation. We concentrate on the energy dependence of the differential PECD of uniaxially oriented TFMOx molecules, which is accessible through the employed coincident detection. We also compare the results for the differential PECD of TFMOx to those obtained for the equivalent fragmentation channel and similar photoelectron kinetic energy of methyloxirane (MOx), studied in our previous work. Thereby, we investigate the influence of the substitution of the methyl group by the trifluoromethyl group at the chiral center on the molecular chiral response. Finally, the presently obtained angular distribution parameters are compared to those available in the literature.
RESUMO
ABSTRACT: A 70-year-old man presented with unspecific abdominal symptoms and weight loss was referred for a sonographic examination. Sonography revealed 3 cystic hepatic masses in an otherwise unremarkable liver. Contrast-enhanced MRI of the liver was performed to characterize the hepatic lesions and elucidate their etiology. The differential diagnosis was primarily parasitic disease or metastases with cystic transformations. 68Ga-DOTATOC PET/CT revealed the neuroendocrine origin of these lesions, confirmed by biopsy. However, the primary site of the neuroendocrine tumor remained unclear, leaving primary hepatic neuroendocrine tumor and neuroendocrine cancer of unknown primary as possible diagnostic options.
Assuntos
Neoplasias Intestinais , Tumores Neuroendócrinos , Compostos Organometálicos , Neoplasias Pancreáticas , Neoplasias Gástricas , Idoso , Humanos , Masculino , Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida , Tomografia por Emissão de Pósitrons combinada à Tomografia ComputadorizadaRESUMO
BACKGROUND: Resection margin status has traditionally been associated with tumor recurrence and oncological outcome following liver resection for colorectal liver metastases. Previous studies, however, did not address the impact of resection margin on the site of tumor recurrence and did not differentiate between true local recurrence at the resection margin and recurrence elsewhere in the liver. This study aimed to determine whether positive resection margins determine local recurrence and whether recurrence at the surgical margin influences long-term survival. METHODS: Clinicopathological data and oncological outcomes of patients who underwent curative resection for colorectal liver metastases between 2012 and 2017 at 2 major hepatobiliary centers (Bern, Switzerland, and Berlin, Germany) were assessed. Cross-sectional imaging following hepatectomy was reviewed by radiologists in both centers to distinguish between recurrence at the resection margin, defined as hepatic local recurrence, and intrahepatic recurrence elsewhere. The association between surgical margin status and location of tumor recurrence was evaluated, and the impact on overall survival was determined. RESULTS: During the study period, 345 consecutive patients underwent hepatectomy for colorectal liver metastases. Histologic surgical margins were positive for tumor cells (R1) in 63 patients (18%). After a median follow-up time of 34 months, tumor recurrence was identified in 154 patients (45%). Hepatic local recurrence was not detected more frequently after R1 than after R0 resection (P = .555). Hepatic local recurrence was not associated with worse overall survival (P = .436), while R1 status significantly impaired overall survival (P = .025). Additionally, overall survival was equivalent between patients with hepatic local recurrence and patients with any intrahepatic and/or extrahepatic recurrence. In patients with intrahepatic recurrence only, oncological outcomes improved if local hepatic therapy was possible (resection or ablation) in comparison to patients treated only with chemotherapy or best supportive care (3-year overall survival: 85% vs 39%; P < .0001). CONCLUSION: The incidence of hepatic local recurrence after hepatectomy for colorectal liver metastases is independent of R1 resection margin status. Additionally, hepatic local recurrence at the resection margin is not associated with worse overall survival compared with any other intra- or extrahepatic recurrence. Therefore, R1 status at hepatectomy seems to be a surrogate factor for advanced disease without influencing location of recurrence and thereby oncological outcome. This finding may support decision-making when extending the indication for surgery in borderline resectable colorectal liver metastases.
Assuntos
Neoplasias Colorretais/patologia , Hepatectomia/estatística & dados numéricos , Neoplasias Hepáticas/cirurgia , Fígado/cirurgia , Recidiva Local de Neoplasia/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Humanos , Fígado/patologia , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Estudos Retrospectivos , Suíça/epidemiologiaRESUMO
OBJECTIVE: To estimate the human resources required for a retrospective quality review of different percentages of all routine diagnostic procedures in the Department of Radiology at Bern University Hospital, Switzerland. MATERIALS AND METHODS: Three board-certified radiologists retrospectively evaluated the quality of the radiological reports of a total of 150 examinations (5 different examination types: abdominal CT, chest CT, mammography, conventional X-ray images and abdominal MRI). Each report was assigned a RADPEER score of 1 to 3 (score 1: concur with previous interpretation; score 2: discrepancy in interpretation/not ordinarily expected to be made; score 3: discrepancy in interpretation/should be made most of the time). The time (in seconds, s) required for each review was documented and compared. A sensitivity analysis was conducted to calculate the total workload for reviewing different percentages of the total annual reporting volume of the clinic. RESULTS: Among the total of 450 reviews analyzed, 91.1â% (410/450) were assigned a score of 1 and 8.9â% (40/450) were assigned scores of 2 or 3. The average time (in seconds) required for a peer review was 60.4âs (min. 5âs, max. 245âs). The reviewer with the greatest clinical experience needed significantly less time for reviewing the reports than the two reviewers with less clinical expertise (pâ<â0.05). Average review times were longer for discrepant ratings with a score of 2 or 3 (pâ<â0.05). The total time requirement calculated for reviewing all 5 types of examination for one year would be more than 1200 working hours. CONCLUSION: A retrospective peer review of reports of radiological examinations using the RADPEER system requires considerable human resources. However, to improve quality, it seems feasible to peer review at least a portion of the total yearly reporting volume. KEY POINTS: · A systematic retrospective assessment of the content of radiological reports using the RADPEER system involves high personnel costs.. · The retrospective assessment of all reports of a clinic or practice seems unrealistic due to the lack of highly specialized personnel.. · At least part of all reports should be reviewed with the aim of improving the quality of reports.. CITATION FORMAT: · Maurer MH, Brönnimann M, Schroeder C etâal. Time Requirement and Feasibility of a Systematic Quality Peer Review of Reporting in Radiology. Fortschr Röntgenstr 2021; 193: 160â-â167.
Assuntos
Revisão por Pares/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiologistas/estatística & dados numéricos , Radiologia/estatística & dados numéricos , Cavidade Abdominal/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Mamografia/métodos , Mamografia/estatística & dados numéricos , Radiografia/métodos , Radiografia/estatística & dados numéricos , Radiologia/normas , Relatório de Pesquisa , Estudos Retrospectivos , Conselhos de Especialidade Profissional/normas , Suíça , Tórax/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Carga de TrabalhoRESUMO
Langerhans cell histiocytosis (LCH) is a myeloid neoplasm with inflammatory properties. There are few published reports of adult LCH with liver involvement, which is still poorly understood, but shows high morbidity and mortality. We report a case of a 37-year-old woman suffering from hepatitis C showing a LCH affecting the lung as well as the liver. Consistent with histology, we found an early stage of a proliferative/granulomatous phase of hepatobiliary LCH, whereas pulmonary findings showed a nodular stage of adult pulmonary LCH. Although hepatocellular carcinoma is a common malignancy in patients suffering from hepatitis C, it is crucial to keep in mind differential diagnosis for newly appearing liver lesions.
RESUMO
BACKGROUND & AIMS: Body composition parameters have been reported to add information, which can lead to tailored treatment and prognostication for oncological patients. Data for patients with hepatocellular carcinoma (HCC) are scarce. We assessed the association between different body composition parameters and overall survival (OS) in two different newly diagnosed HCC populations. METHODS: The area (cm2 ) and density (Hounsfield Units [HU]) of skeletal muscle (SM) and adipose tissue (subcutaneous [SAT], visceral [VAT] and intermuscular [IMAT]) were measured on computed tomography (CT) scans at the level of the third lumbar vertebra (L3) in two cohorts of patients diagnosed in different HCC stages (Bern, Switzerland n = 187 and Newcastle, United Kingdom n = 216). Univariate and multivariate Cox regressions analyses were used to assess the crude and adjusted association of body composition parameters with OS. RESULTS: By univariate analysis, in both cohorts, Bern and Newcastle, high SAT density (hazard ratio [HR]: 1.35; 1.12-1.62, P < .001 and 1.44; 1.27-1.63, P < .001, respectively) and high VAT density (HR: 1.38; 1.1-1.72, P = .005 and HR: 1.53; 1.3-1.81, P < .001, respectively) correlated negatively with survival. After model adjustment for potential baseline confounders (gender, age, diabetes, cirrhosis, MELD score, BCLC stage) in a multivariate analysis, SAT density remained associated with mortality in Bern and Newcastle (Bern: HR: 1.27; 1.04-1.57, P = .022; Newcastle: HR: 1.23; 1.03-1.48, P = .022) and VAT remained associated with mortality in Bern (HR: 1.31; 1.05-1.65, P = .019). CONCLUSIONS: Based on two HCC cohorts, our data show that high SAT density correlates negatively with OS in HCC patients.
Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Tecido Adiposo , Humanos , Gordura Subcutânea , Suíça , Reino UnidoRESUMO
BACKGROUND: Inflammatory myofibroblastic tumors of the liver (IMTL) are extremely rare neoplasms and very little is known about their clinical presentation, pathogenesis, and biological behavior. Due to their absolute rarity, it is almost impossible to obtain a definite diagnosis without histological examination. Because of their intermediate biological behavior with the risk for local recurrence and metastases, surgical resection is recommend whenever IMTL is suspect. CASE SUMMARY: We herein present a case of an otherwise healthy 32-year-old woman who presented with intermittent fever, unclear anemia, malaise and right flank pain 4 mo postpartum. The liver mass in segment IVa/b was highly FDG avid in the positron emission tomography-computed tomography. Hepatic resection was performed achieving a negative resection margin and an immediate resolution of all clinical symptoms. Histological analysis diagnosed the rare finding of an inflammatory myofibroblastic tumor of the liver and revealed cytoplasmic anaplastic lymphoma kinase expression by immunohistochemistry. Twelve months follow-up magnetic resonance imaging showed no recurrence and no metastases in the fully recovered patient. CONCLUSION: IMTLs are extremely rare and difficult to diagnose. Due to their intermediate biological behavior, surgical resection should be perform whenever feasible and patients should be followed-up in order to detect recurrence and metastasis as early as possible.
RESUMO
Background: Therapeutic success of thermal ablation for liver tumors depends on precise placement of ablation probes and complete tumor destruction with a safety margin. We investigated factors influencing targeting accuracy and treatment efficacy of percutaneous stereotactic image-guided microwave ablation (SMWA) for malignant liver neoplasms. Materials and methods: All consecutive patients treated with SMWA for malignant liver tumors over a 3-year period were analyzed. A computed tomography-based navigation system was used for ablation probe trajectory planning, stereotactic probe positioning, and validation of probe positions and ablation zones. Factors potentially influencing targeting accuracy [target positioning error (TPE)] and treatment efficacy within 6 months [ablation site recurrence (ASR)] were analyzed in a multivariable regression model, including challenging lesion locations (liver segments I, VII, and VIII; subphrenic location). Results: Three hundred one lesions (174 hepatocellular carcinomas, 87 colorectal liver metastases, 17 neuroendocrine tumors, and 23 others) were targeted in 191 interventions in 153 patients. The median TPE per ablation probe was 2.9 ± 2.3 mm (n = 384). Correction of ablation probe positions by repositioning was necessary in 4 out of 301 lesions (1%). Factors significantly influencing targeting accuracy were cirrhosis (R 0.67, CI 0.22-1.12) and targeting trajectory length (R 0.21, CI 0.12-0.29). Factors significantly influencing early ASR were lesion size >30 mm (OR 5.22, CI 2.44-11.19) and TPE >5 mm (OR 2.48, CI 1.06-5.78). Challenging lesion locations had no significant influence on targeting accuracy or early ASR. Conclusions: SMWA allows precise and effective treatment of malignant liver tumors even for lesions in challenging locations, with treatment efficacy depending on targeting accuracy in our model. Allowing for many tumors to be safely reached, SMWA has the potential to broaden treatment eligibility for patients with otherwise difficult to target tumors.
RESUMO
In nanoimprint lithography (NIL), a pattern is created by mechanical deformation of an imprint resist via embossing with a stamp, where the adhesion behavior during the filling of the imprint stamp and its subsequent detachment may impose some practical challenges. Here we explored thermal and reverse NIL patterning of polyvinylferrocene and vinylferrocene-methyl methacrylate copolymers to prepare complex non-spherical objects and patterns. While neat polyvinylferrocene was found to be unsuitable for NIL, freshly-prepared vinylferrocene-methyl methacrylate copolymers, for which identity and purity were established, have been structured into 3D-micro/nano-patterns using NIL. The cross-, square-, and circle-shaped columnar structures form a 3 × 3 mm arrangement with periodicity of 3 µm, 1 µm, 542 nm, and 506 nm. According to our findings, vinylferrocene-methyl methacrylate copolymers can be imprinted without further additives in NIL processes, which opens the way for redox-responsive 3D-nano/micro-objects and patterns via NIL to be explored in the future.
Assuntos
Compostos Ferrosos/química , Metilmetacrilato/química , Nanocompostos/química , Polímeros/química , Compostos de Vinila/química , Compostos Ferrosos/síntese química , Metilmetacrilato/síntese química , Impressão Molecular , Polímeros/síntese química , Polivinil/síntese química , Polivinil/química , Propriedades de Superfície , Compostos de Vinila/síntese químicaRESUMO
BACKGROUND: In computed tomography (CT) scans, artifacts caused by metallic orthopedic implants still hamper the visualization of important, periprosthetic tissues. Smart MAR metal artifact reduction tool is a promising three-stage, projection-based, post-processing algorithm. PURPOSE: To determine whether the Smart MAR tool improves subjective and objective image quality and diagnostic confidence in patients with orthopedic implants of the hip, spine, and shoulder. MATERIAL AND METHODS: Seventy-two patients with orthopedic screws, hip/shoulder replacement, or spine spondylodesis were included. CT scans were performed on a single-source multislice CT scanner, raw data were post-processed using Smart MAR. Image quality was evaluated both quantitatively (ROI-based) and qualitatively (rater-based) and compared to iterative reconstructions (ASIR V). As comparative standard for artificial prosthetic breaks or loosening, follow-up examinations were used. RESULTS: Smart MAR reconstructions of the hip (n = 23), spine (n = 26), and shoulder (n = 23) showed a significantly reduced attenuation and noise of regions adjacent to metallic implants (P<0.002). Subjective image quality (P<0.005, shoulder P = 0.038/P = 0.046) and overall diagnostic confidence were higher in Smart MAR (all regions P<0.002). Signal-to-noise ratio (SNR; P = 0.72/P = 0.96) was not improved. Compared to standard ASIR V new, artificial metal extinctions (up to 50%) or periprosthetic hem lines (48%-73%) were introduced by Smart MAR. CONCLUSION: Smart MAR improved image quality of the hip, spine, and shoulder CT scans resulting in higher diagnostic confidence in evaluation of periprosthetic soft tissues. As shown for spine implants, it should be used with caution and as a complementary tool for evaluation of periprosthetic loosening or integrity of metal implant, as in many cases it introduced new artifacts.