Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Artif Organs ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884381

RESUMO

BACKGROUND: Ventricular assist devices (VADs) are used to bridge pediatric patients to heart transplantation. Paracorporeal VADs require the placement of cannulas, which can create an environment for infections. We examined cannula infections in pediatric VAD patients and the role of nutritional status. METHODS: This retrospective study (2005-2021) included patients <20 years old on VAD support using Berlin Heart EXCOR® cannulas. Cannula infections were defined by a positive culture and need for antibiotic therapy. Malnutrition was defined using the American Society of Parenteral and Enteral Nutrition guidelines as well as the Michigan MTool. RESULTS: There were 76 patients with a median age at implant of 0.9 years (IQR 0.4, 3.6), 50% male, with 73.7% having non-congenital heart disease. More than one-quarter (26.3%) of patients developed a cannula infection. Higher pre-implant weight (OR = 1.93, p = 0.05), creatinine (OR = 1.02, p = 0.044), and pre-albumin (OR = 15.79, p = 0.025), as well as duration of VAD support (OR = 1.01; p = 0.003) were associated with increased odds of developing a cannula infection. There was no difference in the malnutrition parameters between those with and without an infection. CONCLUSIONS: Further exploration in a larger cohort is needed to see whether these associations remain and if the incorporation of objective measures of nutritional status at the time of infection are predictive.

2.
ASAIO J ; 69(8): e397-e400, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36881646

RESUMO

Congenitally corrected transposition of the great arteries (ccTGAs) represents a complex form of congenital heart disease that is associated with several cardiac complications. Herein is a case series of three children with ccTGA and ventricular assist device (VAD) inserted for systemic right ventricle failure at a single institution. All patients remained hemodynamically stable postimplant and were successfully discharged from the intensive care unit to undergo postoperative rehabilitation. All three patients received an orthotopic heart transplant with uneventful posttransplant courses. This case series provides insight into the medical management and technical feasibility of VAD support in children with ccTGA with end-stage heart failure.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Transposição dos Grandes Vasos , Humanos , Criança , Transposição das Grandes Artérias Corrigida Congenitamente/complicações , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/cirurgia , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Transplante de Coração/efeitos adversos
4.
World J Pediatr Congenit Heart Surg ; 13(2): 242-244, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35238712

RESUMO

Thromboembolic events post left ventricular assist devices (LVAD) implantation remain a major cause of morbidity and mortality. Mechanical thrombectomy for the treatment of pediatric intracranial thromboembolic events have been reported in LVADs, but never following HeartMate 3 (HM3) implantation. We present the case of an 8-year-old, 26.5 kg male with dilated cardiomyopathy and decompensated heart failure who presented with extensive intracranial thromboembolism in the early postoperative period following HM3 implantation and underwent successful mechanical thrombectomy with a favorable neurological outcome.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Coração Auxiliar , Tromboembolia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/cirurgia , Criança , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Trombectomia , Tromboembolia/etiologia , Tromboembolia/cirurgia , Resultado do Tratamento
5.
J Heart Lung Transplant ; 40(4): 251-259, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33579597

RESUMO

BACKGROUND: The Berlin Heart EXCOR Pediatric (EXCOR) ventricular assist device (VAD) was introduced in North America nearly 2 decades ago. The EXCOR was approved under Humanitarian Device Exemption status in 2011 and received post-market approval (PMA) in 2017 from Food and Drug Administration. Since the initial approval, the field of pediatric mechanical circulatory support has changed, specifically with regard to available devices, anticoagulation strategies, and the types of patients supported. This report summarizes the outcomes of patients supported with EXCOR from the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) registry. These data were part of the PMA surveillance study (PSS) required by the Food and Drug Administration. METHODS: ACTION is a learning collaborative of over 40 pediatric heart failure programs worldwide, which collects data for all VAD implantations as one of its initiatives. All patients in North America with EXCOR implants reported to ACTION from 2018 to 2020 (n = 72) who had met an outcome were included in the EXCOR PSS group. This was compared with a historical, previously reported Berlin Heart EXCOR study group (Berlin Heart study [BHS] group, n = 320, 2007‒2014). RESULTS: Patients in the PSS group were younger, were smaller in weight/body surface area, were more likely to have congenital heart disease, and were less likely to receive a bi-VAD than those in the BHS group. Patients in the PSS group were less likely to be in Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 and were supported for a longer duration. The primary anticoagulation therapy for 92% of patients in the PSS group was bivalirudin. Success, defined as being transplanted, being weaned for recovery, or being alive on a device at 180 days after implantation, was 86% in the PSS group compared with 76% in the BHS group. Incidence of stroke was reduced by 44% and the frequency of pump exchange by 40% in the PSS group compared with those in the BHS group. Similarly, all other adverse events, including major bleeding, were reduced in the PSS group. CONCLUSIONS: The PSS data, collected through ACTION, highlight the improvement in outcomes for patients supported with EXCOR compared with the outcomes in a historical cohort. These findings may be the result of changes in patient care practices over time and collaborative learning.


Assuntos
Aprovação de Equipamentos , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/terapia , Coração Auxiliar/normas , Avaliação de Resultados em Cuidados de Saúde , Vigilância da População/métodos , Sistema de Registros , Pré-Escolar , Feminino , Cardiopatias Congênitas/complicações , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Transplante de Coração , Humanos , Incidência , Lactente , Masculino , América do Norte/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências
6.
ASAIO J ; 54(5): 483-5, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18812738

RESUMO

Caring for pediatric patients with a ventricular assist device (VAD) requires a collaborative approach from an interprofessional team to ensure maximum patient safety and optimal outcomes. Initiating a VAD program is challenging, due to the complex medical and technical nature of this device and associated learning needs. At our institution, the development of the interprofessional VAD support team was established in four phases. Initial Education, Core Team Formation, Expansion, and Evaluation. A "core VAD team" was created after the initial education at an established VAD center. In a third step, all efforts were directed toward increasing the number of health care professionals caring for the VAD patients in the Cardiac Critical Care setting and on the Cardiac ward. The last phase consists of ongoing evaluation. Several key areas imperative to the care of a patient on a VAD were identified and further elaborated. The complex care of a patient on a VAD needs a specialized team approach to cover all patient care needs. Ongoing interprofessional education continues to improve competency of care. Continuity of care was assured on all levels of service to ensure the best possible outcomes.


Assuntos
Coração Auxiliar , Equipe de Assistência ao Paciente , Criança , Comportamento Cooperativo , Pessoal de Saúde , Departamentos Hospitalares , Humanos , Aprendizagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA