RESUMO

Aims: To evaluate whether patients with late complications of pacemakers or implantable cardioverter-defibrillators have hypersensitivity reactions to some of the materials used in generators or in electrodes, or to environmental metal burden. Methods and results: The cohort consisted of 20 men and 4 women (mean age: 62.3 ± 17.2 years) who had a history of late complications of implanted devices. The control group involved 25 men and 8 women (mean age: 64.6 ± 14.0 years) who had comparable devices, but no history of late complications. Lymphocyte transformation test was used to evaluate hypersensitivity to eight metal pollutants (antimony, manganese, mercury, molybdenum, nickel, platinum, tin, and titanium) selected by results of questionnaires on environmental burden, and by material analysis of generators and electrode surfaces. Exposures to metal pollutants were approximately the same in patients and in controls. Titanium alloy used in generators contained at least 99.32% of titanium and trace levels of other metals; higher levels of tin and platinum were detected in electrode surfaces. Hypersensitivity reactions to mercury and tin were significantly more frequent in patients than in controls (patients and controls: mercury: 68.2 and 31.1%, respectively; P = 0.022; tin: 25.0 and 3.2%, respectively; P = 0.035). In contrast, hypersensitivity to manganese was significantly more frequent in controls than in patients (patients and controls: 13.6 and 50.0%, respectively; P = 0.008). Conclusion: Our findings suggest a possible relation between hypersensitivity to metals used in implantable devices or to environmental metal burden and the occurrence of their late complications.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Poluentes Ambientais/efeitos adversos , Hipersensibilidade/epidemiologia , Metais/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese , Idoso , Ligas , Antimônio/efeitos adversos , Feminino , Humanos , Hipersensibilidade/etiologia , Ativação Linfocitária , Masculino , Manganês/efeitos adversos , Mercúrio/efeitos adversos , Pessoa de Meia-Idade , Molibdênio/efeitos adversos , Níquel/efeitos adversos , Dor Pós-Operatória/epidemiologia , Platina/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Dermatopatias/epidemiologia , Estanho/efeitos adversos , Titânio/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA