Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Arthroplasty ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38848790

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) continues to be one of the leading causes of failure following total hip arthroplasty (THA). The objectives of the study were to (1) determine the minimum 2-year infection-free survivorship of 2-stage revision THA, (2) determine the causative organisms for repeat 2-stage revision THA, and (3) characterize the results of failed 2-stage revisions and evaluate patient-reported outcome measures (PROMs). METHODS: A retrospective chart review was completed for patients who underwent 2-stage revision THA for PJI. Prospective data were collected on each patient, including demographics, causative organisms, complications, and type of reoperation. The PROMs, including Harris Hip Score, 12-item Short-Form Health Survey, and Western Ontario and McMaster Universities Osteoarthritis Index scores were obtained prior to 2-stage revision THA surgery and annually as part of standard clinical and radiographic follow-up. RESULTS: A total of 328 patients who underwent a 2-stage revision THA for a PJI were included in the study (mean age 67 years [range, 28 to 90], mean body mass index of 30.6 [range, 15 to 57]). The overall infection-free survivorship for 2-stage revision THA was 73.8% at a minimum of 2 years (range, 2 to 20). Overall, 194 (59.1%) patients who had successful infection eradication underwent a 2-revision THA only. The most common single organisms infected were Staphylococcus aureus (12.5%) and Staphylococcus epidermidis (11%). Higher reoperation rates were found in cases with methicillin-resistant Staphylococcus aureus and polymicrobial infections. All PROMs showed statistical improvement from preoperatively to the latest follow-up appointment. CONCLUSIONS: Two-stage revision THA is associated with a good success rate in the treatment of PJIs at mid-term to long-term follow-up. Polymicrobial and methicillin-resistant Staphylococcus aureus infections are poor prognostic factors, making the eradication of infection more difficult. The management of PJIs continues to be one of the most important orthopaedic challenges to treat.

2.
J Arthroplasty ; 39(8S1): S80-S85, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38710347

RESUMO

BACKGROUND: Routine patellar resurfacing during primary total knee arthroplasty (TKA) remains controversial. To our knowledge, there are no studies reporting the long-term performance of a cemented biconvex all-polyethylene inlay component implanted at the time of primary TKA. The purpose of this study was to examine the 15-year survivorship and long-term clinical outcomes of this biconvex inlay patella used at our institution. METHODS: We retrospectively reviewed our prospectively collected institutional database and identified 2,530 patients who underwent cemented TKA with a single prosthetic design (from 1996 to 2007) where the patella was resurfaced using this cemented biconvex inlay patella. The mean age at surgery was 68 years (range, 29 to 93). The mean body mass index was 33.0 (range, 16.4 to 76.3), with 61.9% women. At the time of analysis, the mean time from surgery was 20.4 years (range, 15 to 26). We used Kaplan-Meier analysis to calculate survivorship at 15 years. We analyzed clinical outcomes using 3 patient-reported outcome measures collected prospectively. RESULTS: The 15-year survivorship with revision surgery for all causes as the end point was 97.1% (95% confidence interval 96.1 to 98.1%). The 15-year survivorship with revision surgery for a patella-related complication as the end point was 99.7% (95% confidence interval 99.4 to 1.0). At the final follow-up, patients showed significant improvement in scores for the Knee Society Clinical Rating System (P < .001), Western Ontario and McMaster University Osteoarthritis Index (P < .001), and Veterans Rand 12-Item Health Survey physical component (P < .001). CONCLUSIONS: Routine patellar resurfacing using a biconvex inlay patellar component has excellent survivorship and a low rate of complications at 15 years post-TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Patela , Desenho de Prótese , Humanos , Artroplastia do Joelho/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Patela/cirurgia , Adulto , Idoso de 80 Anos ou mais , Falha de Prótese , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Estimativa de Kaplan-Meier
3.
J Arthroplasty ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521249

RESUMO

BACKGROUND: Modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. This study reports the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years of follow-up. METHODS: We identified 126 patients who received a single monoblock TFT stem: 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous periprosthetic joint infection, 42 for aseptic loosening, 9 for trunnionosis, and 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3-month follow-up were determined. We evaluated the number and indications for reoperations. RESULTS: The mean time from surgery was 3.9 years (range, 2.0 to 6.9). A paired t-test analysis showed significant improvement from preoperative versus postoperative clinical outcome scores (P < .001) for Harris Hip Score (38.76 ± 15.24 versus 83.42 ± 15.38), Western Ontario and McMaster Universities Arthritis Index (45.6 ± 19.0 versus 69.9 ± 21.3), Veterans RAND 12 Item Health Survey Physical component (31.7 ± 8.1 versus 37.8 ± 11.3), and Veterans RAND 12 Item Health Survey Mental component (48.2 ± 12.2 versus 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%), and Grade 4 (1.6%) cases. There were 18 reoperations (14.7%), with 13 for periprosthetic joint infection (7 treated with implant retention and 6 treated with a 2-stage revision), 4 for instability, and 1 for acetabular aseptic loosening. There were no aseptic failures of the stem. CONCLUSIONS: This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution.

4.
J Arthroplasty ; 39(3): 689-694.e3, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37739141

RESUMO

BACKGROUND: The objective of this study was to identify the rate and risk factors for revision total knee arthroplasty (TKA) within the first 5 years postoperative. Our secondary objective was to identify the rate of additional surgical procedures and death. METHODS: We conducted a retrospective cohort study among patients in Ontario, Canada who underwent an elective, primary TKA between April 1, 2007, and March 31, 2014, for osteoarthritis. We excluded patients under 40 years and who had undergone a TKA within the previous 15 years. Our final study cohort included 94,193 patients. We reported the proportion of the study cohort who experienced revision surgery within 2 and 5 years of the primary TKA; secondary surgery within 5 years. We conducted Cochran-Armitage tests for trends to assess changes in the proportion of patients who experienced each of the study outcomes, and multivariable logistic regressions to evaluate predictors of a revision TKA. RESULTS: There were 3,112 (3.3%) patients who had a revision within 5 years, and 1,866 (2.0%) within 2 years of their primary TKA. 3,316 (3.5%) had a secondary surgery (0.6% patellar resurfacing; 1.6% manipulation; 1.3% synovectomy; 0.5% washout; 0.9% debridement). Lower age, men, lower income, higher comorbidity score, depression, previous arthroscopy, lower surgeon volume, and general anesthesia were all significant positive predictors of revision. CONCLUSIONS: In our study cohort, 2.0% of patients had a revision TKA within 2 years, and 3.3% within 5 years of their primary TKA. Preoperative identification of risk factors may reduce the future prevalence of revision TKAs.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Masculino , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Ontário/epidemiologia , Reoperação/métodos , Articulação do Joelho/cirurgia
5.
J Arthroplasty ; 38(6S): S297-S301, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37003457

RESUMO

BACKGROUND: Hybrid fixation, utilizing diaphyseal press-fit stems and cement fixation in the tibial and femoral metaphyseal areas, has long been a strategy for revision total knee arthroplasty (rTKA). The purpose of this study was to evaluate the clinical outcomes and survivorships of hybrid fixation using a single rTKA revision system with a minimum of 5 years follow-up. METHODS: We reviewed our prospectively collected database to identify 281 patients who underwent rTKA using a single revision system with hybrid fixation and press-fit stems between July 2006 and August 2016. We reviewed the clinical outcome scores, including the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis index, and Veterans RAND 12 Item Health Survey. We also evaluated the 5 and 10-year survivorships and the indications for reoperations. The cohort had a mean age of 70 years (range, 45.2 to 92.0) and a mean body mass index of 33.4 (range, 17.3 to 55.8). The mean time from rTKA surgery was 11.1 years (range, 5.3 to 15.5). RESULTS: Paired t-test analyses showed significant improvements from preoperative versus postoperative clinical outcome scores (P < .001) for Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis, and Veterans RAND 12 Item Health Survey Physical component. Prosthetic joint infections after index rTKA were the most common failure mode with 29 patients requiring reoperations. Rerevision due to aseptic loosening was uncommon (6 patients) with a cumulative survival rate of 95.2% at 5 years and 94.2% at 10 years. CONCLUSION: The use of this single rTKA system utilizing press fit stems combined with hybrid fixation provided significant improvements in the clinical outcomes and excellent survivorships at 5 and 10 years.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite , Humanos , Idoso , Articulação do Joelho/cirurgia , Sobrevivência , Desenho de Prótese , Reoperação , Osteoartrite/cirurgia , Estudos Retrospectivos , Falha de Prótese , Resultado do Tratamento
6.
J Arthroplasty ; 38(7S): S223-S228, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36963526

RESUMO

BACKGROUND: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. METHODS: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. RESULTS: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). CONCLUSION: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Titânio , Desenho de Prótese , Reoperação , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Estudos Retrospectivos
7.
Arthroplast Today ; 18: 39-44, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36267391

RESUMO

Background: Fully porous acetabular shells are an appealing choice for patients with extensive acetabular defects undergoing revision total hip arthroplasty (rTHA). This study reports on the early outcomes of a novel 3-D printed fully porous titanium acetabular shell in revision acetabular reconstruction. Methods: A multicenter retrospective study of patients who received a fully porous titanium acetabular shell for rTHA with a minimum of 2 years of follow-up was conducted. The primary outcome was rate of acetabular revision. Results: The final study cohort comprised 68 patients with a mean age of 67.6 years (standard deviation 10.4) and body mass index of 29.5 kg/m2 (standard deviation 5.9). Ninety-four percent had a preoperative Paprosky defect grade of 2A or higher. The average follow-up duration was 3.0 years (range 2.0-5.1). Revision-free survivorship at 2 years was 81% for all causes, 88% for acetabular revisions, and 90% for acetabular revision for aseptic acetabular shell failure. Eight shells were explanted within 2 years (12%): 3 for failure of osseointegration/aseptic loosening (4%) after 15, 17, and 20 months; 3 for infection (4%) after 1, 3, and 6 months; and 2 for instability (3%). At the latest postoperative follow-up, all unrevised shells showed radiographic signs of osseointegration, and none had migrated. Conclusions: This novel 3-D printed fully porous titanium shell in rTHA demonstrated good survivorship and osseointegration when used in complex acetabular reconstruction at a minimum of 2 years. Level of evidence: IV, case series.

9.
J Arthroplasty ; 37(11): 2262-2271, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35598759

RESUMO

BACKGROUND: The prevalence and outcomes of unexpected positive intraoperative cultures (UPC) in presumed aseptic revision total knee arthroplasty (TKA) are unclear. The purpose of this study was to determine the prevalence of UPC and infection-free implant survival in this patient population. Secondly, we aimed to compare the infection-free implant survival between cohorts based on number of UPCs and antibiotic treatment. METHODS: We reviewed our institutional database from 2006 to 2019 for all TKA revisions (n = 1795) to identify all presumed aseptic TKA revisions with intraoperative culture(s). After exclusions, 775 revisions were eligible and those with UPC were included in the Kaplan-Meier analysis to determine infection-free implant survival for the cohorts. RESULTS: The prevalence of UPC was 9.8%. The 2- and 5-year infection-free survival was 97.4% and 95.3%, respectively. The 5-year infection-free survival from the same microorganism as the UPC was 98.7%. Infection-free survival was similar for the 1 versus ≥2 UPC cohorts (P = .416), however was poorer for the cohort treated with antibiotics (P = .021). Only one of 3 subsequent PJI-related implant failures was caused by the same microorganism (polymicrobial) as the UPC. There were no subsequent infections in patients with a single UPC not treated with antibiotics. CONCLUSIONS: The prevalence of UPC was 9.8% and the infection-free implant survival is excellent. Infection-free survivorship from PJI caused by the same UPC microorganism is outstanding. Comparisons between cohorts must be interpreted with caution due to study limitations. A single UPC in patents without other signs of infection does not require antibiotic treatment. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Humanos , Prótese do Joelho/efeitos adversos , Prevalência , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Reoperação/efeitos adversos , Estudos Retrospectivos
10.
J Arthroplasty ; 37(11): 2208-2213, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35580767

RESUMO

BACKGROUND: The aim of this study was to compare the stem alignment and the quality of cement mantle of collarless polished tapered cemented stems inserted through the direct anterior approach (DAA) and the direct lateral approach (DLA). METHODS: A comparative retrospective study of 232 hybrid total hip arthroplasties using a cemented collarless polished tapered stem through either the DAA (n = 147) or DLA (n = 85) was performed. Radiographic evaluation included stem alignment, cement mantle quality, and cement mantle thickness. RESULTS: On anteroposterior radiographs, stems implanted through the DLA were more likely to be in neutral alignment, than those implanted through the DAA (83.5%[n = 71] versus 71.4% [n = 105]; P = <.001). No difference between approaches was noted for stem alignment on lateral radiographs or cement mantle quality. Multivariate analysis revealed factors associated with suboptimal cement mantle and included Dorr type B or C femur as well as male gender. A mean cement mantle thickness ≥2mm was achieved in all Gruen zones for both approaches. CONCLUSION: In our series, the DAA was associated with a higher incidence of coronal plane stem malalignment compared to the DLA when using cemented tapered polished femoral components for total hip arthroplasty. No difference in lateral stem alignment or cement mantle quality was found.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cimentos Ósseos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos
11.
J Arthroplasty ; 37(7S): S692-S696, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35245689

RESUMO

BACKGROUND: Oxidized zirconium (OxZi) femoral heads combine the decreased abrasive properties of ceramics with the toughness of metal alloys to lower wear and increase the durability of total hip arthroplasty. The purpose of this study was to compare the 10-year polyethylene wear rates between OxZi/XLPE and cobalt chrome (CoCr)/XLPE articulations. METHODS: A radiostereometric analysis (RSA) was performed on two cohorts of 23 patients who underwent total hip arthroplasty using either OxZi/XLPE or CoCr/XLPE at a minimum of 10-year follow-up. Cohorts were matched for age, gender, body mass index (BMI), and diagnosis. Polyethylene wear was measured using RSA to determine total and steady-state wear rates for both cohorts. Preoperative and postoperative patient-reported outcome measures (SF12, HHS, and Western Ontario and McMaster Universities Arthritis Index scores) were compared. RESULTS: The mean total head penetration rate was found to be statistically different between the entire cohorts (OxZi 0.048 ± 0.021 mm/y, CoCr 0.035 ± 0.017 mm/y, P = .02) but not when 28-mm heads only (OxZi 0.045 ± 0.016 mm/y, CoCr 0.034 ± 0.017 mm/y, P = .066) were directly compared. The mean steady-state wear rate was not significantly different between the entire cohorts (OxZi 0.031 ± 0.021 mm/y, CoCr 0.024 ± 0.019 mm/y, P = .24) or 28-mm head cohorts (OxZi 0.028 ± 0.019 mm/y, CoCr 0.024 ± 0.019 mm/y, P = .574). Outcome measures showed no statistical difference except for the Harris Hip Score where the OxZi cohort demonstrated higher median scores. CONCLUSION: Using RSA to evaluate the 10-year in-vivo head penetration, there was no statistically significant difference in steady-state wear rates between OxZi and CoCr articulations. Both bearing combinations demonstrated wear rates well below the threshold for osteolysis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ligas de Cromo , Cobalto , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Análise Radioestereométrica , Zircônio
12.
J Arthroplasty ; 37(6S): S263-S269, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35257822

RESUMO

BACKGROUND: Bone loss remains an anticipated challenge in revision total knee arthroplasty (rTKA). Recent efforts to enhance rTKA fixation and stability have focused on metaphyseal implants, namely cones and sleeves. We sought to compare cone and sleeve implant survivorship in rTKA. METHODS: One hundred eighty patients who underwent rTKA with metaphyseal implants from 2005 to 2018 were retrospectively reviewed. A total of 83 cones (22 femoral, 62 tibial) and 121 sleeves (58 femoral, 63 tibial) were identified. The mean age at the time of surgery was 72 years (range 43-97). Intraoperative Anderson Orthopaedic Research Institute bone loss classifications included the following: type 2A (25), type 2B (98), and type 3 (81). Mean follow-up was 41 months. RESULTS: Revision-free survival for cones was 91.3% vs 92.2% for sleeves (P = .29). Twelve knees (4 cones, 8 sleeves) underwent irrigation, debridement, and polyethylene exchange with metaphyseal implant retention for acute postoperative periprosthetic joint infection (PJI). Development of chronic PJI warranted removal of 7 cones (8.4%), 6 of which were initially placed as part of a 2-stage revision TKA. Eight sleeves (6.6%) were removed for PJI, with all initially placed during a second stage reimplantation. In the absence of infection, survival was 100% and 99.1% for cones and sleeves, respectively. One sleeve was revised for periprosthetic fracture. CONCLUSION: Metaphyseal cones and sleeves offer equally durable survivorship in revision TKA. PJI was the most common mode of implant failure in this series. Importantly, no cases of cone or sleeve aseptic loosening were observed.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Prótese do Joelho , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Infecciosa/cirurgia , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Sobrevivência
13.
J Mech Behav Biomed Mater ; 124: 104845, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34555623

RESUMO

We sought to evaluate wear and kinematics in well-established implants of posterior stabilized (PS) and cruciate retaining (CR) designs. Ninety-one knees implanted for at least five years were examined. The implants were Genesis II PS (Smith & Nephew, Memphis, TN), Sigma PS (DePuy Synthes, Warsaw, IN), or Sigma CR. Radiostereometric analysis (RSA) images were acquired at multiple flexion angles and the 3D positions of the implant components were determined using model-based RSA software. The location of the center of the contact area between the femoral and polyethylene components was used to obtain contact kinematics, and the magnitude of the virtual intersection between the components indicated linear wear. All three groups had paradoxical anterior motion on both condyles, experienced similar net external rotation, and exhibited instances of internal rotation during flexion. The maximum observed wear rate was significantly greater for the Sigma PS than the Genesis II PS on the medial condyle (mean difference = 0.032 mm/year, p = 0.044), but not the lateral condyle, while there was no difference between the Sigma PS and Sigma CR for either condyle. Knees with lateral condylar separation had greater maximum wear rates on the medial condyle (mean difference = 0.033 mm/year, p = 0.001), while those with medial condylar separation had greater maximum wear rates on the lateral condyle (mean difference = 0.044 mm/year, p = 0.014). At long term follow-up in patients with well-functioning implants, there were differences in kinematics and wear resistance between implants. These results suggest that implant design affects long-term kinematics and wear in well-functioning implants and that condylar separation should be avoided to minimize wear.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular
14.
Bone Jt Open ; 1(10): 653-662, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33215098

RESUMO

AIMS: To compare the in vivo long-term fixation achieved by two acetabular components with different porous ingrowth surfaces using radiostereometric analysis (RSA). METHODS: This was a minimum ten-year follow-up of a prospective randomized trial of 62 hips with two different porous ingrowth acetabular components. RSA exams had previously been acquired through two years of follow-up. Patients returned for RSA examination at a minimum of ten years. In addition, radiological appearance of these acetabular components was analyzed, and patient-reported outcome measures (PROMs) obtained. RESULTS: In all, 15 hips were available at ten years. There was no statistically significant difference in PROMS between the two groups; PROMs were improved at ten years compared to preoperative scores. Conventional radiological assessment revealed well-fixed components. There was minimal movement for both porous surfaces in translation (X, Y, Z, 3D translation in mm (median and interquartile range (IQR)), StikTite (Smith and Nephew, Memphis, Tennessee, USA): 0.03 (1.08), 0.12 (0.7), 0.003 (2.3), 0.37 (0.30), and Roughcoat (Smith and Nephew): -0.6 (0.59),-0.1 (0.49), 0.1 (1.12), 0.48 (0.38)), and rotation (X, Y, Z rotation in degrees (median and IQR), (Stiktite: -0.4 (3), 0.28 (2), -0.2 (1), and Roughcoat: - 0.4 (1),-0.1 (1), 0.2 (2)). There was no statistically significant difference between the two cohorts (p-value for X, Y, Z, 3D translation - 0.54, 0.46, 0.87, 0.55 and for X, Y, Z rotation - 0.41, 0.23, 0.23 respectively) at ten years. There was significant correlation between two years and ten years 3D translation for all components (r = 0.81(p =< 0.001)). CONCLUSION: Both porous ingrowth surfaces demonstrated excellent fixation on plain radiographs and with RSA at ten years. Short-term RSA data are good predictors for long-term migration data.

15.
Knee ; 27(5): 1501-1509, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33010767

RESUMO

BACKGROUND: The goal was to evaluate the joint contact kinematics of total knee arthroplasties implanted using patient-specific instrumentation (PSI) compared to conventional instrumentation (CI). We hypothesized that use of PSI would not significantly alter contact kinematics. METHODS: The study was a prospective randomized controlled trial, with equal allocation of fifty patients to PSI and CI groups. At two years post-operation, patients underwent weight-bearing stereo X-ray examinations at 0°, 20°, 40°, 60°, 80°, and 100° of flexion. The shortest tibiofemoral distance on each condyle determined the contact location. Magnitude of the shortest distance was measured and condylar separation was analyzed using thresholds of 0.5 and 0.75 mm. Kinematic measurements derived from the shortest distance included anteroposterior (AP) translation, excursion, axial rotation, and paradoxical anterior motion. Pivot position and cam/post contact were also investigated. RESULTS: There were no differences (p > 0.05) in medial and lateral AP contact locations, excursions, and magnitude of anterior motion, or in axial rotation, pivot patterns, frequency of cam/post engagement, frequency of medial anterior motion, and condylar separation at a 0.75 mm threshold. Significant differences were found in frequency of lateral anterior motion (p = 0.048) and condylar separation at a 0.5 mm threshold (p = 0.010). Both groups displayed typical kinematics for a fixed-bearing posterior-stabilized implant. CONCLUSIONS: We found no major differences in knee kinematics between PSI and CI groups, which suggest that PSI does not provide a significant kinematic advantage over conventional instruments.


Assuntos
Artroplastia do Joelho/instrumentação , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Idoso , Artroplastia do Joelho/métodos , Feminino , Humanos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Masculino , Impressão Tridimensional , Estudos Prospectivos , Análise Radioestereométrica
17.
Orthop Res Rev ; 12: 145-150, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32982490

RESUMO

INTRODUCTION: Corrosion at the head-neck interface of modular components in total hip arthroplasty (THA) has been reported as a cause of failure of modern total hip replacement implants. While this method of failure has been well described, it remains poorly understood. The purpose of this study is to review the three most commonly used uncemented femoral stems at our institution over the last fifteen years and to correlate any established risk factors with rates of revision, particularly corrosion. METHODS: We reviewed 2095 patients from March 2000 to September 2015 who underwent total hip arthroplasty with one of three uncemented femoral stem designs. All stems were made of a Ti6Al4V alloy with a 12/14 taper design. We included only those stems coupled with a CoCr head and a highly crosslinked polyethylene liner. We evaluated age, gender, body mass index (BMI), femoral head size, head length, neck angle and offset and correlated these to the incidence of all cause revision, as well as revision excluding infection. RESULTS: There were no recognized corrosion-related revisions identified. There was no association between age, BMI, gender, head length, neck angle and offset to all cause revision or revision with infection excluded (p>0.05). Femoral head size less than 32mm was associated with higher all cause revision rates (OR 4.60 (95% CI 1.8, 11.8)) and when excluding infection as a reason for revision (OR 4.94 (95% CI 1.7, 14.41)). CONCLUSION: Over the last fifteen years, we have not identified any cases of corrosion with the three most commonly used femoral stems used at out institution. While we acknowledge that no femoral stem is immune to corrosion, certain femoral stem designs may be uniquely resistant to this mode of failure. LEVEL OF EVIDENCE: III.

19.
J Arthroplasty ; 35(7): 1862-1867, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32229148

RESUMO

BACKGROUND: A contemporary, porous-coated acetabular implant designed for uncemented insertion was introduced in Europe and Australia in 2007. A similar previous acetabular system was found in several studies at 10 to 15-year follow-up to demonstrate accelerated polyethylene wear, osteolysis, and early failure. The current study was conducted to determine the midterm safety and effectiveness of this contemporary acetabular system using highly crosslinked polyethylene and ceramic liners at 5-year follow-up. METHODS: A prospective, nonrandomized study was conducted at 8 sites in Canada and the United States. All 148 study participants received a contemporary acetabular shell with proprietary porous coating. The primary outcome was the requirement for revision surgery at 5 years postoperatively. Secondary outcomes included a survival analysis, patient-reported outcome measures, radiographic failure, and postoperative adverse events. RESULTS: At 5-year follow-up there was 1 cup revised for deep infection. No cups were revised for loosening and none were found to be radiographically loose. The overall survival rate with reoperation for any reason was 97.1%. The success rate was 96.8% for polyethylene and 100% for ceramic with no difference in the success rate between either bearing surface (P = 1.0). The mean patient-reported outcome measures all improved significantly between preoperative and 5-year postoperative scores (P < .001). CONCLUSION: Results from this 5-year, multicenter, prospective study indicate excellent survivorship for this acetabular system when used with crosslinked polyethylene or ceramic bearing surfaces.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Austrália , Canadá , Europa (Continente) , Seguimentos , Humanos , Porosidade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
20.
J Arthroplasty ; 35(6): 1662-1666, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32088053

RESUMO

BACKGROUND: The rise in total hip arthroplasty (THA) has led to a concomitant increase in revision THAs. Tracking implant performance therefore remains a significant element of scientific inquiry to garner and maintain public trust in this procedure. There are few available reports of outcomes of a single manufacturer's total hip system outside registry data. METHODS: We performed a retrospective review of a prospectively generated database to evaluate outcomes of a single manufacturer's femoral stem and acetabular shell for THA. We report the functional outcomes, revision data, and survivorship for this total hip system. RESULTS: A total of 1942 primary THAs were implanted into 1672 patients. There were of 57 revisions. There were no cases of acetabular failure at 10-year follow-up. All functional outcome scores demonstrated significant improvements following THA. Kaplan-Meier survival analysis for all-cause revisions demonstrated 2-year implant survival of 97.6% (95% confidence interval [CI], 96.9-98.3), 5-year implant survival of 97.3% (95% CI, 96.5-98.1), and 10-year implant survival of 97.0% (95% CI, 96.0-98.0). When infection was excluded, implant survivorship improved to 99.2% (95% CI, 98.8-99.6) at 2 years, 98.9% (95% CI, 98.5-99.4) at 5 years, and 98.7% (95% CI, 98.1-99.4) at 10 years. CONCLUSION: This THA implant system comprising an uncemented press-fit acetabulum used alongside a triple-tapered femoral stem is an excellent option for THA. Implant survivorship at 2, 5, and 10 years is among the best reported for any total hip system in the world.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Seguimentos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Sobrevivência , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA