Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38590268

RESUMO

INTRODUCTION: Ventricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years. METHODS: We performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed. RESULTS: A total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5-297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545  (IQR 152-1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39-2.64, p < .001). CONCLUSION: Following LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre-implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.

2.
Heart Rhythm O2 ; 5(3): 150-157, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560374

RESUMO

Background: The outcomes of left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) in patients with heart failure remain to be learned. Objective: The objective of this study was to assess the echocardiographic and clinical outcomes of LBBP, LVSP, and deep septal pacing (DSP). Methods: This retrospective study included patients who met the criteria for cardiac resynchronization therapy (CRT) and underwent attempted LBBP in 5 Mayo centers. Clinical, electrocardiographic, and echocardiographic data were collected at baseline and follow-up. Results: A total of 91 consecutive patients were included in the study. A total of 52 patients had LBBP, 25 had LVSP, and 14 had DSP. The median follow-up duration was 307 (interquartile range 208, 508) days. There was significant left ventricular ejection fraction (LVEF) improvement in the LBBP and LVSP groups (from 35.9 ± 8.5% to 46.9 ± 10.0%, P < .001 in the LBBP group; from 33.1 ± 7.5% to 41.8 ± 10.8%, P < .001 in the LVSP group) but not in the DSP group. A unipolar paced right bundle branch block morphology during the procedure in lead V1 was associated with higher odds of CRT response. There was no significant difference in heart failure hospitalization and all-cause deaths between the LBBP and LVSP groups. The rate of heart failure hospitalization and all-cause deaths were increased in the DSP group compared with the LBBP group (hazard ratio 5.10, 95% confidence interval 1.14-22.78, P = .033; and hazard ratio 7.83, 95% confidence interval 1.38-44.32, P = .020, respectively). Conclusion: In patients undergoing CRT, LVSP had comparable CRT outcomes compared with LBBP.

3.
JMIR Res Protoc ; 13: e50339, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315514

RESUMO

BACKGROUND: Blockchain has been proposed as a critical technology to facilitate more patient-centric research and health information sharing. For instance, it can be applied to coordinate and document dynamic informed consent, a procedure that allows individuals to continuously review and renew their consent to the collection, use, or sharing of their private health information. Such has been suggested to facilitate ethical, compliant longitudinal research, and patient engagement. However, blockchain-based dynamic consent is a relatively new concept, and it is not yet clear how well the suggested implementations will work in practice. Efforts to critically evaluate implementations in health research contexts are limited. OBJECTIVE: The objective of this protocol is to guide the identification and critical appraisal of implementations of blockchain-based dynamic consent in health research contexts, thereby facilitating the development of best practices for future research, innovation, and implementation. METHODS: The protocol describes methods for an integrative review to allow evaluation of a broad range of quantitative and qualitative research designs. The PRISMA-P (Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols) framework guided the review's structure and nature of reporting findings. We developed search strategies and syntax with the help of an academic librarian. Multiple databases were selected to identify pertinent academic literature (CINAHL, Embase, Ovid MEDLINE, PubMed, Scopus, and Web of Science) and gray literature (Electronic Theses Online Service, ProQuest Dissertations and Theses, Open Access Theses and Dissertations, and Google Scholar) for a comprehensive picture of the field's progress. Eligibility criteria were defined based on PROSPERO (International Prospective Register of Systematic Reviews) requirements and a criteria framework for technology readiness. A total of 2 reviewers will independently review and extract data, while a third reviewer will adjudicate discrepancies. Quality appraisal of articles and discussed implementations will proceed based on the validated Mixed Method Appraisal Tool, and themes will be identified through thematic data synthesis. RESULTS: Literature searches were conducted, and after duplicates were removed, 492 articles were eligible for screening. Title and abstract screening allowed the removal of 312 articles, leaving 180 eligible articles for full-text review against inclusion criteria and confirming a sufficient body of literature for project feasibility. Results will synthesize the quality of evidence on blockchain-based dynamic consent for patient-centric research and health information sharing, covering effectiveness, efficiency, satisfaction, regulatory compliance, and methods of managing identity. CONCLUSIONS: The review will provide a comprehensive picture of the progress of emerging blockchain-based dynamic consent technologies and the rigor with which implementations are approached. Resulting insights are expected to inform best practices for future research, innovation, and implementation to benefit patient-centric research and health information sharing. TRIAL REGISTRATION: PROSPERO CRD42023396983; http://tinyurl.com/cn8a5x7t. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/50339.

5.
J Clin Med ; 12(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38068481

RESUMO

(1) Background: Telemetry units allow the continuous monitoring of vital signs and ECG of patients. Such physiological indicators work as the digital signatures and biomarkers of disease that can aid in detecting abnormalities that appear before cardiac arrests (CAs). This review aims to identify the vital sign abnormalities measured by telemetry systems that most accurately predict CAs. (2) Methods: We conducted a systematic review using PubMed, Embase, Web of Science, and MEDLINE to search studies evaluating telemetry-detected vital signs that preceded in-hospital CAs (IHCAs). (3) Results and Discussion: Out of 45 studies, 9 met the eligibility criteria. Seven studies were case series, and 2 were case controls. Four studies evaluated ECG parameters, and 5 evaluated other physiological indicators such as blood pressure, heart rate, respiratory rate, oxygen saturation, and temperature. Vital sign changes were highly frequent among participants and reached statistical significance compared to control subjects. There was no single vital sign change pattern found in all patients. ECG alarm thresholds may be adjustable to reduce alarm fatigue. Our review was limited by the significant dissimilarities of the studies on methodology and objectives. (4) Conclusions: Evidence confirms that changes in vital signs have the potential for predicting IHCAs. There is no consensus on how to best analyze these digital biomarkers. More rigorous and larger-scale prospective studies are needed to determine the predictive value of telemetry-detected vital signs for IHCAs.

6.
Am J Cardiol ; 204: 14-21, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37536198

RESUMO

Patients with repaired tetralogy of Fallot are at elevated risk for ventricular arrhythmia and sudden cardiac death. Over the past decade, the pathogenesis and natural history of ventricular tachycardia has become increasingly understood, and catheter ablation has emerged as an effective treatment modality. Concurrently, there has been great progress in the development of a versatile array of transcatheter valves that can be placed in the native right ventricular outflow tract for the treatment of long-standing pulmonary regurgitation. Although such valve platforms may eliminate the need for repeat cardiac operations, they may also impede catheter access to the myocardial substrates responsible for sustained macro-reentrant ventricular tachycardia. This manuscript provides the rationale and design of a recently devised multicenter study that will examine the clinical outcomes of a uniform, preemptive strategy to eliminate ventricular tachycardia substrates before transcatheter pulmonary valve implantation in patients with tetralogy of Fallot.


Assuntos
Ablação por Cateter , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Valva Pulmonar/cirurgia , Arritmias Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
7.
Circ Arrhythm Electrophysiol ; 16(8): 437-446, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37485717

RESUMO

BACKGROUND: The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described. METHODS: In a retrospective study of adult patients with congenital heart disease who underwent catheter ablation for atrial fibrillation between 2000 and 2020 at Mayo Clinic, procedural characteristics and outcomes were collected. The primary outcomes were atrial arrhythmia (AA) recurrence following a 3-month blanking period and repeat ablation. An arrhythmia clinical severity score was assessed pre- and post-ablation based on the duration of arrhythmia episodes, symptoms, cardioversion frequency, and antiarrhythmic drug use. RESULTS: One hundred forty-five patients (age, 57±12 years; 28% female; 63% paroxysmal atrial fibrillation) underwent 198 ablations with a median follow-up of 26 months (interquartile range, 14-69). One hundred ten, 26, and 9 patients had simple, moderate, and complex congenital heart disease, respectively. All patients underwent pulmonary vein isolation, and non-pulmonary vein targets were ablated in 79 (54%). AA recurrence at 12 months was 37% (95% CI, 29%-45%). On univariate analysis, increasing left atrial volume index was associated with higher odds of AA recurrence (odds ratio, 1.03 [1.00-1.06] per 1 mL/m2 increment; P=0.05). Noninducibility of atrial flutter was predictive of decreased odds of AA recurrence (odds ratio, 0.43 [0.21-0.90]; P=0.03). A second ablation was performed in 43 patients after a median of 20 (interquartile range, 8-37) months. Arrhythmia clinical severity scores improved following ablation, reflecting a decrease in symptoms, cardioversions, and antiarrhythmic drugs. CONCLUSIONS: Catheter ablation of atrial fibrillation is feasible and effective in patients with adult congenital heart disease and reduces symptoms. Recurrence of AA frequently requires repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Veias Pulmonares , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Antiarrítmicos/uso terapêutico , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
8.
Int J Cardiol ; 389: 131173, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37423567

RESUMO

BACKGROUND: Myocardial inflammation contributes to the pathogenesis of arrhythmogenic cardiomyopathy (ACM), a clinically and genetically heterogenous disorder. Due to phenotypic overlap, some patients with genetic ACM may be evaluated for an underlying inflammatory cardiomyopathy. However, the cardiac fludeoxyglucose (FDG) positron emission tomography (PET) findings in ACM patients have not been elucidated. METHODS: All genotype-positive patients in the Mayo Clinic ACM registry (n = 323) who received a cardiac FDG PET were included in this study. Pertinent data were extracted from the medical record. RESULTS: Collectively, 12/323 (4%; 67% female) genotype-positive ACM patients received a cardiac PET FDG scan as part of their clinical evaluation (median age at scan 49 ± 13 years). Amongst these patients, pathogenic/likely pathogenic variants were detected in LMNA (n = 7), DSP (n = 3), FLNC (n = 1) and PLN (n = 1). Of note, 6/12 (50%) had abnormal myocardial FDG uptake, including diffuse (entire myocardium) uptake in 2/6 (33%), focal (1-2 segments) uptake in 2/6 (33%) and patchy (3+ segments) in 2/6 (33%). Median myocardial standardized uptake value ratio was 2.1. Interestingly, LMNA-positive patients accounted for 3 out of 6 (50%) positive studies (diffuse uptake in 2 and focal uptake in 1). CONCLUSION: Abnormal myocardial FDG uptake is common in genetic ACM patients undergoing cardiac FDG PET. This study further supports the role of myocardial inflammation in ACM. Further investigation is needed to determine role of FDG PET in diagnosis and management of ACM and investigate the role of inflammation in ACM.


Assuntos
Fluordesoxiglucose F18 , Miocardite , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Tomografia por Emissão de Pósitrons/métodos , Inflamação , Genótipo , Compostos Radiofarmacêuticos
9.
Indian J Plast Surg ; 56(2): 103-111, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37153341

RESUMO

Photodamage is caused by chronic sun exposure and ultraviolet radiation and presents as wrinkles, sagging, and pigmented spots. An increase in the ultraviolet index can increase a person's perceived age by worsening skin photodamage. However, since the ultraviolet index varies considerably between geographical regions, perceived age might vary substantially among them. This review aims to describe the differences in chronological and perceived age in regions of the world with different ultraviolet indexes. A literature search of three databases was conducted for studies analyzing perceived age and its relationship to sun exposure. Ultraviolet indexes from the included studies were retrieved from the National Weather Service and the Tropospheric Emission Monitoring Internet Service. Out of 104 studies, seven fulfilled the inclusion criteria. Overall, 3,352 patients were evaluated for perceived age. All studies found that patients with the highest daily sun exposures had the highest perceived ages for their chronological age ( p < 0.05). People with high sun exposure behaviors living in regions with high ultraviolet indexes will look significantly older than same-aged peers living in lower ultraviolet index regions.

10.
Bioengineering (Basel) ; 10(5)2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37237618

RESUMO

Pain assessment is a complex task largely dependent on the patient's self-report. Artificial intelligence (AI) has emerged as a promising tool for automating and objectifying pain assessment through the identification of pain-related facial expressions. However, the capabilities and potential of AI in clinical settings are still largely unknown to many medical professionals. In this literature review, we present a conceptual understanding of the application of AI to detect pain through facial expressions. We provide an overview of the current state of the art as well as the technical foundations of AI/ML techniques used in pain detection. We highlight the ethical challenges and the limitations associated with the use of AI in pain detection, such as the scarcity of databases, confounding factors, and medical conditions that affect the shape and mobility of the face. The review also highlights the potential impact of AI on pain assessment in clinical practice and lays the groundwork for further study in this area.

11.
Circ Arrhythm Electrophysiol ; 16(5): e011365, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37082954

RESUMO

BACKGROUND: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. METHODS: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. RESULTS: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). CONCLUSIONS: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos
12.
Bioengineering (Basel) ; 10(4)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37106687

RESUMO

Pain is a complex and subjective experience, and traditional methods of pain assessment can be limited by factors such as self-report bias and observer variability. Voice is frequently used to evaluate pain, occasionally in conjunction with other behaviors such as facial gestures. Compared to facial emotions, there is less available evidence linking pain with voice. This literature review synthesizes the current state of research on the use of voice recognition and voice analysis for pain detection in adults, with a specific focus on the role of artificial intelligence (AI) and machine learning (ML) techniques. We describe the previous works on pain recognition using voice and highlight the different approaches to voice as a tool for pain detection, such as a human effect or biosignal. Overall, studies have shown that AI-based voice analysis can be an effective tool for pain detection in adult patients with various types of pain, including chronic and acute pain. We highlight the high accuracy of the ML-based approaches used in studies and their limitations in terms of generalizability due to factors such as the nature of the pain and patient population characteristics. However, there are still potential challenges, such as the need for large datasets and the risk of bias in training models, which warrant further research.

13.
Diagnostics (Basel) ; 13(6)2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36980474

RESUMO

Unnecessary ED visits and transfers to hand clinics raise treatment costs and patient burden at trauma centers. In the present COVID-19 pandemic, needless transfers can increase patients' risk of viral exposure. Therefore, this review analyzes different aspects of the remote diagnosis and triage of traumatic hand injuries. The most common file was photography, with the most common devices being cell phone cameras. Treatment, triage, diagnosis, cost, and time outcomes were assessed, showing concordance between teleconsultation and face-to-face patient evaluations. We conclude that photography and video consultations are feasible surrogates for ED visits in patients with traumatic hand injuries. These technologies should be leveraged to decrease treatment costs and potentially decrease the time to definitive treatment after initial evaluation.

14.
JACC Clin Electrophysiol ; 9(6): 824-832, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36481190

RESUMO

BACKGROUND: Recognition of the causes of early mortality after ventricular tachycardia (VT) ablation in patients with reduced left ventricular ejection fraction (LVEF) is an essential step toward improving postprocedural outcomes. OBJECTIVES: This study sought to determine the causes of early mortality (≤30 days) after VT ablation in patients with reduced LVEF and to understand further the circumstances surrounding death after the procedure. METHODS: We performed a retrospective analysis of all patients undergoing VT ablation in patients with reduced LVEF from January 1, 2013, to November 10, 2021, at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record within the Mayo Clinic system and outside records. RESULTS: A total of 503 patients (mean age 63 ± 13 years, 11.2% women) with ejection fraction <50% were included in the study. The 30-day all-cause mortality rate was 5.0% (n = 25), and the mortality rate due to a procedural complication was 0.4%. Among all 30-day deaths, recurrent VT was the most common primary cause of death (44.0%). This was followed by decompensated heart failure (28.0%), procedure-related death (8.0%), cerebrovascular accident (4.0%), and infection (4.0%). Most patients (91.0%) who died from VT had VT recurrence within 3 days of the ablation. The average PAINESD score among early mortality was 20 ± 4, and 92.0% of these patients (n = 23) had a score >15. Significant predictors of early mortality included nonischemic cardiomyopathy, lower LVEF, electrical storm, and ventricular fibrillation. CONCLUSIONS: The overall early mortality (≤30 days) rate after catheter ablation of VT in patients with reduced LVEF was 5.0%, but the death rate directly due to a procedural complication was only 0.4%. The most common cause of death was recurrent VT, followed by heart failure. Further research into ablation strategies is vital to improving the safety, efficacy, and durability of VT ablation.


Assuntos
Ablação por Cateter , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Insuficiência Cardíaca/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
15.
Hand (N Y) ; 18(2): 340-348, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34032154

RESUMO

BACKGROUND: Wearable devices and sensor technology provide objective, unbiased range of motion measurements that help health care professionals overcome the hindrances of protractor-based goniometry. This review aims to analyze the accuracy of existing wearable sensor technologies for hand range of motion measurement and identify the most accurate one. METHODS: We performed a systematic review by searching PubMed, CINAHL, and Embase for studies evaluating wearable sensor technology in hand range of motion assessment. Keywords used for the inquiry were related to wearable devices and hand goniometry. RESULTS: Of the 71 studies, 11 met the inclusion criteria. Ten studies evaluated gloves and 1 evaluated a wristband. The most common types of sensors used were bend sensors, followed by inertial sensors, Hall effect sensors, and magnetometers. Most studies compared wearable devices with manual goniometry, achieving optimal accuracy. Although most of the devices reached adequate levels of measurement error, accuracy evaluation in the reviewed studies might be subject to bias owing to the use of poorly reliable measurement techniques for comparison of the devices. CONCLUSION: Gloves using inertial sensors were the most accurate. Future studies should use different comparison techniques, such as infrared camera-based goniometry or virtual motion tracking, to evaluate the performance of wearable devices.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Mãos , Amplitude de Movimento Articular
16.
Aesthetic Plast Surg ; 47(1): 442-454, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35650301

RESUMO

INTRODUCTION: Perceived age is defined as how old a person looks to external evaluators. It reflects the underlying biological age, which is a measure based on physical and physiological parameters reflecting a person's aging process more accurately than chronological age. People with a higher biological age have shorter lives compared to those with a lower biological age with the same chronological age. Our review aims to find whether increased perceived age is a risk factor for overall mortality risk or comorbidities. METHODS: A literature search of three databases was conducted following the PRISMA guidelines for studies analyzing perceived age or isolated facial characteristics of old age and their relationship to mortality risk or comorbidity outcomes. Data on the number of patients, type and characteristics of evaluation methods, evaluator characteristics, mean chronologic age, facial characteristics studied, measured outcomes, and study results were collected. RESULTS: Out of 977 studies, 15 fulfilled the inclusion criteria. These studies found an increase in mortality risk of 6-51% in older-looking people compared to controls (HR 1.06-1.51, p < 0.05). In addition, perceived age and some facial characteristics of old age were also associated with cardiovascular risk and myocardial infarction, cognitive function, bone mineral density, and chronic obstructive pulmonary disease (COPD). CONCLUSION: Perceived age promises to be a clinically useful predictor of overall mortality and cardiovascular, pulmonary, cognitive, and osseous comorbidities. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Fatores Etários , Comorbidade , Mortalidade , Idoso , Humanos
17.
J Am Heart Assoc ; 11(22): e025121, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36346046

RESUMO

Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18-77) years at initiation of CRT. Median follow-up time was 4.1 (25th-75th percentile, 1.3-8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro-transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th-75th percentile, II-III; after CRT: II, 25th-75th percentile, II-III; P=0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P=0.003) in patients with pre-CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long-term follow-up with a marginal but significant increase in SRV function (before CRT; 30%, 25th-75th percentile, 25-35; after CRT: 31%, 25th-75th percentile, 21-38; P=0.049). In contrast, no beneficial change in the above-mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow-up, and mortality at latest follow-up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing-induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Transposição dos Grandes Vasos , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
18.
Circ Arrhythm Electrophysiol ; 15(9): e011088, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36074649

RESUMO

BACKGROUND: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. METHODS: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. RESULTS: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67-89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25-14) before the ablation to a median of 4% (interquartile range, 1-7.75) after the ablation (P=0.03 [95% CI, 0.055-6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P=0.16). CONCLUSIONS: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Adulto , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Meios de Contraste , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
19.
Artigo em Inglês | MEDLINE | ID: mdl-35948726

RESUMO

BACKGROUND: While the triggers for ventricular fibrillation (VF) are well-known, the substrate required for its maintenance remains elusive. We have previously demonstrated dynamic spatiotemporal changes across VF from electrical induction of VF to asystole. Those data suggested that VF drivers seemed to reside in the distal RV and LV. However, signals from these areas were not recorded continuously. The aim of this study was to map these regions of significance with stationary basket electrodes from induction to asystole to provide further insights into the critical substrate for VF rhythm sustenance in canines. METHODS: In six healthy canines, three multipolar basket catheters were positioned in the distal right ventricle (RV), RV outflow tract, and distal left ventricle (LV), and remained in place throughout the study. VF was induced via direct current application from an electrophysiologic catheter. Surface and intracardiac electrograms were recorded simultaneously and continuously from baseline, throughout VF, and until asystole, in order to get a complete electrophysiologic analysis of VF. Focused data analysis was also performed via two defined stages of VF: early VF (immediately after induction of VF to 10 min) and late VF (after 10 min up to VF termination and asystole). RESULTS: VF was continuously mapped for a mean duration of 54 ± 9 min (range 42-70 min). Immediately after initiation of VF in the early phase, the distal LV region appeared to drive the maintenance of VF. Towards the terminal stage of VF, the distal RV region appeared to be responsible for VF persistence. In all canines, we noted local termination of VF in the LV, while VF on surface ECG continued; conversely, subsequent spontaneous termination of VF in the RV was associated with termination of VF on surface ECG into a ventricular escape rhythm. Continuous mapping of VF showed trends towards an increase in peak-to-peak ventricular electrogram cycle length (p = 0.06) and a decrease in the ventricular electrogram amplitude (p = 0.06) after 40 min. Once we could no longer discern surface QRS activity, we demonstrated local ventricular myocardial capture in both the RV and LV but could not reinitiate sustained VF despite aggressive ventricular burst pacing. CONCLUSIONS: This study describes the evolution of VF from electrical initiation to spontaneous VF termination without hemodynamic support in healthy canines. These data are hypothesis-generating and suggest that critical substrate for VF maintenance may reside in both the distal RV and LV depending on stage of VF. Further studies are needed to replicate these findings with hemodynamic support and to translate such findings into clinical practice. Ventricular fibrillation maintenance may be dependent on critical structures in the distal RV. ECG: electrocardiogram; LV: left ventricle; RV: right ventricle; RVOT: right ventricular outflow tract; VF: ventricular fibrillation.

20.
Circ Arrhythm Electrophysiol ; 15(7): e010744, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35763435

RESUMO

BACKGROUND: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. METHODS: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. RESULTS: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P=0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. CONCLUSIONS: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.


Assuntos
Desfibriladores Implantáveis , Anomalia de Ebstein , Marca-Passo Artificial , Adulto , Desfibriladores Implantáveis/efeitos adversos , Anomalia de Ebstein/etiologia , Anomalia de Ebstein/cirurgia , Eletrônica , Feminino , Coração , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA