Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Radiat Res ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38918000

RESUMO

The relative biological effectiveness is a mathematical quantity first defined in the 1950s. This has resulted in more than 4,000 scientific papers published to date. Yet defining the correct value of the RBE to use in clinical practice remains a challenge. A scientific analysis in the radiation research literature can provide an understanding of how this mathematical quantity has evolved. The purpose of this study is to investigate documents published since 1950 using bibliometric indicators and network visualization. This analysis seeks to provide an assessment of global research activities, key themes, and RBE research within the radiation-related field. It strives to highlight top-performing authors, organizations, and nations that have made major contributions to this research domain, as well as their interactions. The Scopus Collection was searched for articles and reviews pertaining to RBE in radiation research from 1950 through 2023. Scopus and Bibiometrix analytic tools were used to investigate the most productive countries, researchers, collaboration networks, journals, along with the citation analysis of references and keywords. A total of 4,632 documents were retrieved produced by authors originating from 71 countries. Publication trends could be separated in 20-year groupings beginning with slow accrual from 1950 to 1970, an early rise from 1970-1990, followed by a sharp increase in the years 1990s-2010s that matches the development of charged particle therapy in clinics worldwide and opened discussion on the true value of the RBE in proton beam therapy. Since the 2010s, a steady 200 papers, on average, have been published per year. The United States produced the most publications overall (N = 1,378) and Radiation Research was the most likely journal to have published articles related to the RBE (606 publications during this period). J. Debus was the most prolific author (112 contributions, with 2,900 citations). The RBE has captured the research interest of over 7,000 authors in the past decade alone. This study supports that notion that the growth of the body of evidence surrounding the RBE, which started 75 years ago, is far from reaching its end. Applications to medicine have continuously dominated the field, with physics competing with Biochemistry, Genetics and Molecular Biology for second place over the decades. Future research can be predicted to continue.

2.
Phys Med Biol ; 67(8)2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35263730

RESUMO

Objective. In the irradiation of living tissue, the fundamental physical processes involved in radical production typically occur on a timescale of a few femtoseconds. A detailed understanding of these phenomena has thus far been limited by the relatively long duration of the radiation sources employed, extending well beyond the timescales for radical generation and evolution.Approach. Here, we propose a femtosecond-scale photon source, based on inverse Compton scattering of laser-plasma accelerated electron beams in the field of a second scattering laser pulse.Main results. Detailed numerical modelling indicates that existing laser facilities can provide ultra-short and high-flux MeV-scale photon beams, able to deposit doses tuneable from a fraction of Gy up to a few Gy per pulse, resulting in dose rates exceeding 1013Gy/s.Significance. We envisage that such a source will represent a unique tool for time-resolved radiobiological experiments, with the prospect of further advancing radio-therapeutic techniques.


Assuntos
Elétrons , Aceleradores de Partículas , Lasers , Fótons/uso terapêutico , Radiobiologia
3.
Clin Oncol (R Coll Radiol) ; 33(11): 705-712, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34454806

RESUMO

Microbeam radiotherapy (MRT) is the delivery of spatially fractionated beams that have the potential to offer significant improvements in the therapeutic ratio due to the delivery of micron-sized high dose and dose rate beams. They build on longstanding clinical experience of GRID radiotherapy and more recently lattice-based approaches. Here we briefly overview the preclinical evidence for MRT efficacy and highlight the challenges for bringing this to clinical utility. The biological mechanisms underpinning MRT efficacy are still unclear, but involve vascular, bystander, stem cell and potentially immune responses. There is probably significant overlap in the mechanisms underpinning MRT responses and FLASH radiotherapy that needs to be further defined.


Assuntos
Radioterapia (Especialidade) , Radiobiologia , Humanos , Radioterapia
4.
Clin Oncol (R Coll Radiol) ; 30(5): 285-292, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29454504

RESUMO

With the current UK expansion of proton therapy there is a great opportunity for clinical oncologists to develop a translational interest in the associated scientific base and clinical results. In particular, the underpinning controversy regarding the conversion of photon dose to proton dose by the relative biological effectiveness (RBE) must be understood, including its important implications. At the present time, the proton prescribed dose includes an RBE of 1.1 regardless of tissue, tumour and dose fractionation. A body of data has emerged against this pragmatic approach, including a critique of the existing evidence base, due to choice of dose, use of only acute-reacting in vivo assays, analysis methods and the reference radiations used to determine the RBE. Modelling systems, based on the best available scientific evidence, and which include the clinically useful biological effective dose (BED) concept, have also been developed to estimate proton RBEs for different dose and linear energy transfer (LET) values. The latter reflect ionisation density, which progressively increases along each proton track. Late-reacting tissues, such as the brain, where α/ß = 2 Gy, show a higher RBE than 1.1 at a low dose per fraction (1.2-1.8 Gy) at LET values used to cover conventional target volumes and can be much higher. RBE changes with tissue depth seem to vary depending on the method of beam delivery used. To reduce unexpected toxicity, which does occasionally follow proton therapy, a more rational approach to RBE allocation, using a variable RBE that depends on dose per fraction and the tissue and tumour radiobiological characteristics such as α/ß, is proposed.


Assuntos
Neoplasias/radioterapia , Terapia com Prótons/métodos , Radiobiologia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Eficiência Biológica Relativa , Humanos
5.
Phys Med Biol ; 62(8): 3237-3249, 2017 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-28350546

RESUMO

Whilst Monte Carlo (MC) simulations of proton energy deposition have been well-validated at the macroscopic level, their microscopic validation remains lacking. Equally, no gold-standard yet exists for experimental metrology of individual proton tracks. In this work we compare the distributions of stochastic proton interactions simulated using the TOPAS-nBio MC platform against confocal microscope data for Al2O3:C,Mg fluorescent nuclear track detectors (FNTDs). We irradiated [Formula: see text] mm3 FNTD chips inside a water phantom, positioned at seven positions along a pristine proton Bragg peak with a range in water of 12 cm. MC simulations were implemented in two stages: (1) using TOPAS to model the beam properties within a water phantom and (2) using TOPAS-nBio with Geant4-DNA physics to score particle interactions through a water surrogate of Al2O3:C,Mg. The measured median track integrated brightness (IB) was observed to be strongly correlated to both (i) voxelized track-averaged linear energy transfer (LET) and (ii) frequency mean microdosimetric lineal energy, [Formula: see text], both simulated in pure water. Histograms of FNTD track IB were compared against TOPAS-nBio histograms of the number of terminal electrons per proton, scored in water with mass-density scaled to mimic Al2O3:C,Mg. Trends between exposure depths observed in TOPAS-nBio simulations were experimentally replicated in the study of FNTD track IB. Our results represent an important first step towards the experimental validation of MC simulations on the sub-cellular scale and suggest that FNTDs can enable experimental study of the microdosimetric properties of individual proton tracks.


Assuntos
Prótons , Radiometria/métodos , Elétrons , Transferência Linear de Energia , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/instrumentação , Processos Estocásticos , Água/química
6.
Phys Med Biol ; 61(16): 5993-6010, 2016 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-27435339

RESUMO

Gold nanoparticles (GNPs) have shown potential as dose enhancers for radiation therapy. Since damage to the genome affects the viability of a cell, it is generally assumed that GNPs have to localise within the cell nucleus. In practice, however, GNPs tend to localise in the cytoplasm yet still appear to have a dose enhancing effect on the cell. Whether this effect can be attributed to stress-induced biological mechanisms or to physical damage to extra-nuclear cellular targets is still unclear. There is however growing evidence to suggest that the cellular response to radiation can also be influenced by indirect processes induced when the nucleus is not directly targeted by radiation. The mitochondrion in particular may be an effective extra-nuclear radiation target given its many important functional roles in the cell. To more accurately predict the physical effect of radiation within different cell organelles, we measured the full chemical composition of a whole human lymphocytic JURKAT cell as well as two separate organelles; the cell nucleus and the mitochondrion. The experimental measurements found that all three biological materials had similar ionisation energies ∼70 eV, substantially lower than that of liquid water ∼78 eV. Monte Carlo simulations for 10-50 keV incident photons showed higher energy deposition and ionisation numbers in the cell and organelle materials compared to liquid water. Adding a 1% mass fraction of gold to each material increased the energy deposition by a factor of ∼1.8 when averaged over all incident photon energies. Simulations of a realistic compartmentalised cell show that the presence of gold in the cytosol increases the energy deposition in the mitochondrial volume more than within the nuclear volume. We find this is due to sub-micron delocalisation of energy by photoelectrons, making the mitochondria a potentially viable indirect radiation target for GNPs that localise to the cytosol.


Assuntos
Núcleo Celular/efeitos da radiação , Citosol/efeitos da radiação , Ouro/química , Nanopartículas Metálicas/química , Mitocôndrias/efeitos da radiação , Fótons , Humanos , Células Jurkat , Método de Monte Carlo , Doses de Radiação
7.
Nanotechnology ; 27(21): 215101, 2016 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-27080849

RESUMO

Radiation resistance and toxicity in normal tissues are limiting factors in the efficacy of radiotherapy. Gold nanoparticles (GNPs) have been shown to be effective at enhancing radiation-induced cell death, and were initially proposed to physically enhance the radiation dose deposited. However, biological responses of GNP radiosensitization based on physical assumptions alone are not predictive of radiosensitisation and therefore there is a fundamental research need to determine biological mechanisms of response to GNPs alone and in combination with ionising radiation. This study aimed to identify novel mechanisms of cancer cell radiosensitisation through the use of GNPs, focusing on their ability to induce cellular oxidative stress and disrupt mitochondrial function. Using N-acetyl-cysteine, we found mitochondrial oxidation to be a key event prior to radiation for the radiosensitisation of cancer cells and suggests the overall cellular effects of GNP radiosensitisation are a result of their interaction with protein disulphide isomerase (PDI). This investigation identifies PDI and mitochondrial oxidation as novel targets for radiosensitisation.


Assuntos
Acetilcisteína/farmacologia , Ouro/farmacologia , Nanopartículas Metálicas/química , Neoplasias/enzimologia , Isomerases de Dissulfetos de Proteínas/metabolismo , Radiossensibilizantes/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Ouro/química , Humanos , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Potencial da Membrana Mitocondrial/efeitos da radiação , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/efeitos da radiação , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Estresse Oxidativo/efeitos da radiação
8.
Br J Radiol ; 87(1041): 20140134, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24990037

RESUMO

A new efficient type of gadolinium-based theranostic agent (AGuIX®) has recently been developed for MRI-guided radiotherapy (RT). These new particles consist of a polysiloxane network surrounded by a number of gadolinium chelates, usually 10. Owing to their small size (<5 nm), AGuIX typically exhibit biodistributions that are almost ideal for diagnostic and therapeutic purposes. For example, although a significant proportion of these particles accumulate in tumours, the remainder is rapidly eliminated by the renal route. In addition, in the absence of irradiation, the nanoparticles are well tolerated even at very high dose (10 times more than the dose used for mouse treatment). AGuIX particles have been proven to act as efficient radiosensitizers in a large variety of experimental in vitro scenarios, including different radioresistant cell lines, irradiation energies and radiation sources (sensitizing enhancement ratio ranging from 1.1 to 2.5). Pre-clinical studies have also demonstrated the impact of these particles on different heterotopic and orthotopic tumours, with both intratumoural or intravenous injection routes. A significant therapeutical effect has been observed in all contexts. Furthermore, MRI monitoring was proven to efficiently aid in determining a RT protocol and assessing tumour evolution following treatment. The usual theoretical models, based on energy attenuation and macroscopic dose enhancement, cannot account for all the results that have been obtained. Only theoretical models, which take into account the Auger electron cascades that occur between the different atoms constituting the particle and the related high radical concentrations in the vicinity of the particle, provide an explanation for the complex cell damage and death observed.


Assuntos
Gadolínio , Nanopartículas , Neoplasias/tratamento farmacológico , Radiossensibilizantes , Animais , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética , Camundongos , Modelos Teóricos , Neoplasias/radioterapia , Radiossensibilizantes/química , Siloxanas
9.
Br J Radiol ; 87(1036): 20130781, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24472729

RESUMO

OBJECTIVE: The aim of this study was to investigate the effect of pre-treatment verification imaging with megavoltage X-rays on cancer and normal cell survival in vitro and to compare the findings with theoretically modelled data. Since the dose received from pre-treatment imaging can be significant, the incorporation of this dose at the planning stage of treatment has been suggested. METHODS: The impact of imaging dose incorporation on cell survival was investigated by clonogenic assay of irradiated DU-145 prostate cancer, H460 non-small-cell lung cancer and AGO-1522b normal tissue fibroblast cells. Clinically relevant imaging-to-treatment times of 7.5 and 15 min were chosen for this study. The theoretical magnitude of the loss of radiobiological efficacy due to sublethal damage repair was investigated using the Lea-Catcheside dose protraction factor model. RESULTS: For the cell lines investigated, the experimental data showed that imaging dose incorporation had no significant impact on cell survival. These findings were in close agreement with theoretical results. CONCLUSION: For the conditions investigated, the results suggest that allowance for the imaging dose at the planning stage of treatment should not adversely affect treatment efficacy. ADVANCES IN KNOWLEDGE: There is a paucity of data in the literature on imaging effects in radiotherapy. This article presents a systematic study of imaging dose effects on cancer and normal cell survival, providing both theoretical and experimental evidence for clinically relevant imaging doses and imaging-to-treatment times. The data provide a firm foundation for further study into this highly relevant area of research.


Assuntos
Sobrevivência Celular/efeitos da radiação , Modelos Biológicos , Neoplasias/radioterapia , Radioterapia de Alta Energia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Linhagem Celular Tumoral , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Modelos Teóricos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Radioterapia Assistida por Computador/métodos , Fatores de Tempo
10.
Clin Oncol (R Coll Radiol) ; 26(3): 142-50, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24332210

RESUMO

AIMS: To investigate the potential dosimetric and clinical benefits predicted by using four-dimensional computed tomography (4DCT) compared with 3DCT in the planning of radical radiotherapy for non-small cell lung cancer. MATERIALS AND METHODS: Twenty patients were planned using free breathing 4DCT then retrospectively delineated on three-dimensional helical scan sets (3DCT). Beam arrangement and total dose (55 Gy in 20 fractions) were matched for 3D and 4D plans. Plans were compared for differences in planning target volume (PTV) geometrics and normal tissue complication probability (NTCP) for organs at risk using dose volume histograms. Tumour control probability and NTCP were modelled using the Lyman-Kutcher-Burman (LKB) model. This was compared with a predictive clinical algorithm (Maastro), which is based on patient characteristics, including: age, performance status, smoking history, lung function, tumour staging and concomitant chemotherapy, to predict survival and toxicity outcomes. Potential therapeutic gains were investigated by applying isotoxic dose escalation to both plans using constraints for mean lung dose (18 Gy), oesophageal maximum (70 Gy) and spinal cord maximum (48 Gy). RESULTS: 4DCT based plans had lower PTV volumes, a lower dose to organs at risk and lower predicted NTCP rates on LKB modelling (P < 0.006). The clinical algorithm showed no difference for predicted 2-year survival and dyspnoea rates between the groups, but did predict for lower oesophageal toxicity with 4DCT plans (P = 0.001). There was no correlation between LKB modelling and the clinical algorithm for lung toxicity or survival. Dose escalation was possible in 15/20 cases, with a mean increase in dose by a factor of 1.19 (10.45 Gy) using 4DCT compared with 3DCT plans. CONCLUSIONS: 4DCT can theoretically improve therapeutic ratio and dose escalation based on dosimetric parameters and mathematical modelling. However, when individual characteristics are incorporated, this gain may be less evident in terms of survival and dyspnoea rates. 4DCT allows potential for isotoxic dose escalation, which may lead to improved local control and better overall survival.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Tomografia Computadorizada Quadridimensional/efeitos adversos , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
11.
Clin Oncol (R Coll Radiol) ; 25(10): 586-92, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23849503

RESUMO

Classical radiation biology research has centred on nuclear DNA as the main target of radiation-induced damage. Over the past two decades, this has been challenged by a significant amount of scientific evidence clearly showing radiation-induced cell signalling effects to have important roles in mediating overall radiobiological response. These effects, generally termed radiation-induced bystander effects (RIBEs) have challenged the traditional DNA targeted theory in radiation biology and highlighted an important role for cells not directly traversed by radiation. The multiplicity of experimental systems and exposure conditions in which RIBEs have been observed has hindered precise definitions of these effects. However, RIBEs have recently been classified for different relevant human radiation exposure scenarios in an attempt to clarify their role in vivo. Despite significant research efforts in this area, there is little direct evidence for their role in clinically relevant exposure scenarios. In this review, we explore the clinical relevance of RIBEs from classical experimental approaches through to novel models that have been used to further determine their potential implications in the clinic.


Assuntos
Efeito Espectador/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Humanos , Radiobiologia , Transdução de Sinais/efeitos da radiação
12.
Sci Rep ; 3: 1770, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23640660

RESUMO

Biological validation of new radiotherapy modalities is essential to understand their therapeutic potential. Antiprotons have been proposed for cancer therapy due to enhanced dose deposition provided by antiproton-nucleon annihilation. We assessed cellular DNA damage and relative biological effectiveness (RBE) of a clinically relevant antiproton beam. Despite a modest LET (~19 keV/µm), antiproton spread out Bragg peak (SOBP) irradiation caused significant residual γ-H2AX foci compared to X-ray, proton and antiproton plateau irradiation. RBE of ~1.48 in the SOBP and ~1 in the plateau were measured and used for a qualitative effective dose curve comparison with proton and carbon-ions. Foci in the antiproton SOBP were larger and more structured compared to X-rays, protons and carbon-ions. This is likely due to overlapping particle tracks near the annihilation vertex, creating spatially correlated DNA lesions. No biological effects were observed at 28-42 mm away from the primary beam suggesting minimal risk from long-range secondary particles.


Assuntos
Carbono/química , Dano ao DNA , Prótons , Carbono/farmacologia , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Humanos , Íons/farmacologia , Radioterapia/métodos , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Raios X
13.
Phys Med Biol ; 58(5): N83-94, 2013 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-23399781

RESUMO

Flattening filter free (FFF) linear accelerators allow for an increase in instantaneous dose-rate of the x-ray pulses by a factor of 2-6 over the conventional flattened output. As a result, radiobiological investigations are being carried out to determine the effect of these higher dose-rates on cell response. The studies reported thus far have presented conflicting results, highlighting the need for further investigation. To determine the radiobiological impact of the increased dose-rates from FFF exposures a Varian Truebeam medical linear accelerator was used to irradiate two human cancer cell lines in vitro, DU-145 prostate and H460 non-small cell lung, with both flattened and FFF 6 MV beams. The fluence profile of the FFF beam was modified using a custom-designed Nylon compensator to produce a similar dose profile to the flattened beam (6X) at the cell surface but at a higher instantaneous dose-rate. For both cell lines there appeared to be no significant change in cell survival. Curve fitting coefficients for DU145 cells irradiated with constant average dose-rates were 6X: α = 0.09 ± 0.03, ß = 0.03 ± 0.01 and 6FFF: α = 0.14 ± 0.13, ß = 0.03 ± 0.02 with a significance of p = 0.75. For H460 cells irradiated with the same instantaneous dose-rate but different average dose-rate the fit coefficients were 6FFF (low dose-rate): α = 0.21 ± 0.11, 0.07 ± 0.02 and 6FFF (high dose-rate): α = 0.21 ± 0.16, 0.07 ± 0.03, with p = 0.79. The results indicate that collective damage behaviour does not occur at the instantaneous dose-rates investigated here and that the use of either modality should result in the same clinical outcome, however this will require further validation in vivo.


Assuntos
Radiobiologia , Radioterapia Assistida por Computador/métodos , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos da radiação , Humanos , Masculino , Radiometria , Dosagem Radioterapêutica , Fatores de Tempo
14.
Nanotechnology ; 21(29): 295101, 2010 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-20601762

RESUMO

High atomic number (Z) materials such as gold preferentially absorb kilovoltage x-rays compared to soft tissue and may be used to achieve local dose enhancement in tumours during treatment with ionizing radiation. Gold nanoparticles have been demonstrated as radiation dose enhancing agents in vivo and in vitro. In the present study, we used multiple endpoints to characterize the cellular cytotoxic response of a range of cell lines to 1.9 nm gold particles and measured dose modifying effects following transient exposure at low concentrations. Gold nanoparticles caused significant levels of cell type specific cytotoxicity, apoptosis and increased oxidative stress. When used as dose modifying agents, dose enhancement factors varied between the cell lines investigated with the highest enhancement being 1.9 in AGO-1522B cells at a nanoparticle concentration of 100 microg ml(-1). This study shows exposure to 1.9 nm gold particles to induce a range of cell line specific responses including decreased clonogenic survival, increased apoptosis and induction of DNA damage which may be mediated through the production of reactive oxygen species. This is the first study involving 1.9 nm nanometre sized particles to report multiple cellular responses which impact on the radiation dose modifying effect. The findings highlight the need for extensive characterization of responses to gold nanoparticles when assessing dose enhancing potential in cancer therapy.


Assuntos
Ouro/farmacologia , Nanopartículas Metálicas/uso terapêutico , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Processos de Crescimento Celular/efeitos dos fármacos , Processos de Crescimento Celular/efeitos da radiação , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Quebras de DNA de Cadeia Dupla , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Citometria de Fluxo , Ouro/administração & dosagem , Ouro/farmacocinética , Humanos , Nanopartículas Metálicas/química , Dinâmica não Linear , Oxirredução , Estresse Oxidativo/efeitos dos fármacos , Estresse Oxidativo/efeitos da radiação , Radiossensibilizantes/administração & dosagem , Radiossensibilizantes/química , Radiossensibilizantes/farmacocinética
15.
Am J Ophthalmol ; 130(5): 645-52, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11078843

RESUMO

PURPOSE: To report retrieval of a medial rectus muscle completely detached from the globe and lost in the orbital tissue in four eyes. METHOD: A lost medial rectus muscle was retrieved in four eyes of four patients with either a transcutaneous medial orbitotomy approach or a transnasal endoscopic ethmoid sinus approach. RESULTS: The lost medial rectus muscle was successfully retrieved in all four patients. One patient lost the medial rectus muscle secondary to trauma, and the other three cases resulted from complications of strabismus surgery. The mean preoperative angle of exotropia was 44 prism diopters. The endoscopic approach was attempted in three patients, and the medial rectus muscle was successfully found in two of these patients. In one case in which the endoscopic approach was used, an image guidance system was used to aid in finding the lost medial rectus muscle. The endoscopic approach was abandoned in one case in which the medial rectus muscle could not be identified after extensive searching, but the muscle was subsequently found by means of the transcutaneous medial orbitotomy approach. A transcutaneous medial orbitotomy alone was used to find the lost medial rectus muscle in one of the cases. The postoperative ocular deviation for primary position at distance fixation was a mean of 24 prism diopters of exotropia. With one additional operation in two patients, the mean ocular deviation was less than 12 prism diopters. CONCLUSION: We successfully retrieved a lost medial rectus muscle in four patients with the use of nontraditional strabismus surgical techniques. We effectively combined techniques taken from both ophthalmology and otorhinolaryngology to help solve this difficult problem.


Assuntos
Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Procedimentos Cirúrgicos Otorrinolaringológicos , Complicações Pós-Operatórias/cirurgia , Adulto , Criança , Endoscopia , Traumatismos Oculares/complicações , Feminino , Humanos , Masculino , Músculos Oculomotores/diagnóstico por imagem , Órbita/diagnóstico por imagem , Órbita/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Estrabismo/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
Arch Otolaryngol Head Neck Surg ; 123(12): 1304-7, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9413358

RESUMO

OBJECTIVES: To assess the relationship and incidence of cervical spine injuries in patients with mandibular fractures and to recommend an organized approach to cervical spine evaluation in these patients. DESIGN: A retrospective review of medical records of all patients with mandibular fractures at a level I trauma hospital from 1984 through 1993. Patient demographics, injury, mechanism of injury, associated symptoms, physical presentation, and adjuvant radiographic evaluations were recorded. SETTING: Level I, 1000-bed, urban trauma center in Atlanta, Ga. RESULTS: A total of 1382 patients with mandibular fractures were examined during the 10-year period of review. Cervical spine radiographs were obtained on 501 (36.3%) of these patients. From these radiographs, only 8 cervical spine fractures were found. All of the patients with cervical spine injuries (n = 8) had other associated maxillofacial injuries (n = 4), were involved in a motor vehicle accident (n = 7), or sustained gunshot wounds (n = 1). CONCLUSIONS: Judicious use of cervical spine radiographs in the appropriate setting of mandibular trauma is beneficial. However, clinical criteria should dictate rational use of radiographs, since the association between cervical spine injuries and mandibular trauma is rare and predictable.


Assuntos
Vértebras Cervicais/lesões , Fraturas Mandibulares/complicações , Fraturas da Coluna Vertebral/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/diagnóstico por imagem , Criança , Pré-Escolar , Protocolos Clínicos , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem
17.
Kidney Int ; 46(3): 647-52, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7527873

RESUMO

We reported that cyclosporin A (CsA) inhibits Na+/K(+)-ATPase activity in specific segments of the rat nephron. In this study, we tested the hypothesis that cyclosporin A reduces Na+/K(+)-ATPase activity through inhibition of calcineurin. In T cells, cyclosporin A and FK506 bind to immunophilins and inhibit the phosphatase activity of calcineurin; Rapamycin and SDZ 220-384 also bind to immunophilins but do not change calcineurin activity. Na+/K(+)-ATPase activity was measured in microdissected rat proximal tubule (S2 subsegment), medullary thick ascending limb (mTAL), and cortical collecting duct (CCD). First we found that two inhibitors of calcineurin, pentafluorophenol (PFP, 100 mM) and peptide 412 (1 mM), significantly reduced Na+/K(+)-ATPase activity in the CCD by 78% and 70%, respectively. In CCDs, FK506 inhibited Na+/K(+)-ATPase activity by 61 to 85% at concentrations of 1.5 to 6 ng/ml, but not at 0.5 ng/ml. FK506 (6 ng/ml) inhibited Na+/K(+)-ATPase activity in mTALs by 56% but did not inhibit it in S2s or glomeruli. In contrast, Rapamycin (12.5 ng/ml) did not change Na+/K(+)-ATPase activity in CCDs or mTALs, but at a concentration of 12.5 micrograms/ml did block the inhibitory effect of FK506 (6 ng/ml) in both segments. SDZ 220-384 (600 ng/ml) did not change Na+/K(+)-ATPase activity in CCDs. Thus, in CCDs and mTALs: (1) FK506, like cyclosporin A, inhibits Na+/K(+)-ATPase activity; (2) Rapamycin and SDZ 220-384 do not inhibit Na+/K(+)-ATPase activity; and (3) Rapamycin prevents FK506-induced inhibition of Na+/K(+)-ATPase activity. These responses may be explained by a direct inhibition of calcineurin activity yielding lower Na+/K(+)-ATPase activity in CCDs and mTALs.


Assuntos
Proteínas de Ligação a Calmodulina/antagonistas & inibidores , Túbulos Renais/efeitos dos fármacos , Fosfoproteínas Fosfatases/antagonistas & inibidores , ATPase Trocadora de Sódio-Potássio/antagonistas & inibidores , Tacrolimo/farmacologia , Animais , Western Blotting , Calcineurina , Proteínas de Ligação a Calmodulina/fisiologia , Relação Dose-Resposta a Droga , Imunossupressores/farmacologia , Túbulos Renais/enzimologia , Masculino , Fosfoproteínas Fosfatases/fisiologia , Ratos , Ratos Sprague-Dawley , ATPase Trocadora de Sódio-Potássio/metabolismo , Organismos Livres de Patógenos Específicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA