Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(25): e2218951120, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37307440

RESUMO

We report a label-free acoustic microfluidic method to confine single, cilia-driven swimming cells in space without limiting their rotational degrees of freedom. Our platform integrates a surface acoustic wave (SAW) actuator and bulk acoustic wave (BAW) trapping array to enable multiplexed analysis with high spatial resolution and trapping forces that are strong enough to hold individual microswimmers. The hybrid BAW/SAW acoustic tweezers employ high-efficiency mode conversion to achieve submicron image resolution while compensating for parasitic system losses to immersion oil in contact with the microfluidic chip. We use the platform to quantify cilia and cell body motion for wildtype biciliate cells, investigating effects of environmental variables like temperature and viscosity on ciliary beating, synchronization, and three-dimensional helical swimming. We confirm and expand upon the existing understanding of these phenomena, for example determining that increasing viscosity promotes asynchronous beating. Motile cilia are subcellular organelles that propel microorganisms or direct fluid and particulate flow. Thus, cilia are critical to cell survival and human health. The unicellular alga Chlamydomonas reinhardtii is widely used to investigate the mechanisms underlying ciliary beating and coordination. However, freely swimming cells are difficult to image with sufficient resolution to capture cilia motion, necessitating that the cell body be held during experiments. Acoustic confinement is a compelling alternative to use of a micropipette, or to magnetic, electrical, and optical trapping that may modify the cells and affect their behavior. Beyond establishing our approach to studying microswimmers, we demonstrate a unique ability to mechanically perturb cells via rapid acoustic positioning.


Assuntos
Acústica , Natação , Humanos , Som , Cílios , Corpo Celular
2.
BMJ Open ; 11(9): e045557, 2021 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-34475144

RESUMO

OBJECTIVE: The COVID-19 pandemic has precipitated widespread shortages of filtering facepiece respirators (FFRs) and the creation and sharing of proposed substitutes (novel designs, repurposed materials) with limited testing against regulatory standards. We aimed to categorically test the efficacy and fit of potential N95 respirator substitutes using protocols that can be replicated in university laboratories. SETTING: Academic medical centre with occupational health-supervised fit testing along with laboratory studies. PARTICIPANTS: Seven adult volunteers who passed quantitative fit testing for small-sized (n=2) and regular-sized (n=5) commercial N95 respirators. METHODS: Five open-source potential N95 respirator substitutes were evaluated and compared with commercial National Institute for Occupational Safety and Health (NIOSH)-approved N95 respirators as controls. Fit testing using the 7-minute standardised Occupational Safety and Health Administration fit test was performed. In addition, protocols that can be performed in university laboratories for materials testing (filtration efficiency, air resistance and fluid resistance) were developed to evaluate alternate filtration materials. RESULTS: Among five open-source, improvised substitutes evaluated in this study, only one (which included a commercial elastomeric mask and commercial HEPA filter) passed a standard quantitative fit test. The four alternative materials evaluated for filtration efficiency (67%-89%) failed to meet the 95% threshold at a face velocity (7.6 cm/s) equivalent to that of a NIOSH particle filtration test for the control N95 FFR. In addition, for all but one material, the small surface area of two 3D-printed substitutes resulted in air resistance that was above the maximum in the NIOSH standard. CONCLUSIONS: Testing protocols such as those described here are essential to evaluate proposed improvised respiratory protection substitutes, and our testing platform could be replicated by teams with similar cross-disciplinary research capacity. Healthcare professionals should be cautious of claims associated with improvised respirators when suggested as FFR substitutes.


Assuntos
COVID-19 , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Adulto , Desenho de Equipamento , Humanos , Respiradores N95 , Pandemias/prevenção & controle , SARS-CoV-2 , Estados Unidos , Ventiladores Mecânicos
3.
J Acoust Soc Am ; 150(2): 1565, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34470271

RESUMO

Acoustic microfluidics (or acoustofluidics) provides a non-contact and label-free means to manipulate and interrogate bioparticles. Owing to their biocompatibility and precision, acoustofluidic approaches have enabled innovations in various areas of biomedical research. Future breakthroughs will rely on the translation of these techniques from academic labs to clinical and industrial settings. Here, accurate characterization and standardization of device performance are crucial. Versatile, rapid, and widely accessible performance quantification is needed. We propose a field quantification method using motile Chlamydomonas reinhardtii algae cells. We previously reported qualitative mapping of acoustic fields using living microswimmers as active probes. In the present study, we extend our approach to achieve the challenging quantitative in situ measurement of the acoustic energy density. C. reinhardtii cells continuously swim in an imposed force field and dynamically redistribute as the field changes. This behavior allows accurate and complete, real-time performance monitoring, which can be easily applied and adopted within the acoustofluidics and broader microfluidics research communities. Additionally, the approach relies only on standard bright-field microscopy to assess the field under numerous conditions within minutes. We benchmark the method against conventional passive-particle tracking, achieving agreement within 1% for field strengths from 0 to 70 J m-3 (from 0 to ∼0.8 MPa).


Assuntos
Acústica , Microfluídica
4.
J Acoust Soc Am ; 150(2): 1300, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34470276

RESUMO

Droplet spraying is utilized in diverse industrial processes and biomedical applications, including nanomaterial synthesis, biomaterial handling, and inhalation drug delivery. Ultrasonic droplet generators transfer energy into bulk liquids using acoustic waves to disrupt the free liquid surface into fine microdroplets. We previously established a method combining ultrasonic actuation, resonant operation, and acoustic wave focusing for efficient spraying of various liquids (e.g., low surface tension fuels, high viscosity inks, and suspensions of biological cells). The microfabricated device comprises a piezoelectric transducer, sample reservoir, and an array of acoustic horn structures terminated by microscale orifices. Orifice size roughly dictates droplet diameter, and a fixed reservoir height prescribes specific device resonant frequencies of operation. Here, we incorporate a continuously variable liquid reservoir height for dynamic adjustment of operating parameters to improve spray efficiency in real-time and potentially tune the droplet size. Computational modeling predicts the system harmonic response for a range of reservoir heights from 0.5 to 3 mm (corresponding to operating frequencies from ∼500 kHz to 2.5 MHz). Nozzle arrays with 10, 20, and 40 µm orifices are evaluated for spray uniformity and stability of the active nozzles, using model predictions to explain the experimental observations.


Assuntos
Acústica , Ultrassom , Som , Transdutores
5.
ISME J ; 15(11): 3384-3398, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34054125

RESUMO

Photoferrotrophy allows anoxygenic phototrophs to use reduced iron as an electron donor for primary productivity. Recent work shows that freshwater photoferrotrophs can use electrons from solid-phase conductive substances via phototrophic extracellular electron uptake (pEEU), and the two processes share the underlying electron uptake mechanism. However, the ability of marine phototrophs to perform photoferrotrophy and pEEU, and the contribution of these processes to primary productivity is largely unknown. To fill this knowledge gap, we isolated 15 new strains of the marine anoxygenic phototroph Rhodovulum sulfidophilum on electron donors such as acetate and thiosulfate. We observed that all of the R. sulfidophilum strains isolated can perform photoferrotrophy. We chose strain AB26 as a representative strain to study further, and find that it can also perform pEEU from poised electrodes. We show that during pEEU, AB26 transfers electrons to the photosynthetic electron transport chain. Furthermore, systems biology-guided mutant analysis shows that R. sulfidophilum AB26 uses a previously unknown diheme cytochrome c protein, which we call EeuP, for pEEU but not photoferrotrophy. Homologs of EeuP occur in a range of widely distributed marine microbes. Overall, these results suggest that photoferrotrophy and pEEU contribute to the biogeochemical cycling of iron and carbon in marine ecosystems.


Assuntos
Elétrons , Rhodovulum , Transporte Biológico , Ecossistema , Rhodovulum/genética
6.
Lab Chip ; 21(13): 2534-2543, 2021 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-33998632

RESUMO

Controlled trapping of cells and microorganisms using substrate acoustic waves (SAWs; conventionally termed surface acoustic waves) has proven useful in numerous biological and biomedical applications owing to the label- and contact-free nature of acoustic confinement. However, excessive heating due to vibration damping and other system losses potentially compromises the biocompatibility of the SAW technique. Herein, we investigate the thermal biocompatibility of polydimethylsiloxane (PDMS)-based SAW and glass-based SAW [that supports a bulk acoustic wave (BAW) in the fluid domain] devices operating at different frequencies and applied voltages. First, we use infrared thermography to produce heat maps of regions of interest (ROI) within the aperture of the SAW transducers for PDMS- and glass-based devices. Motile Chlamydomonas reinhardtii algae cells are then used to test the trapping performance and biocompatibility of these devices. At low input power, the PDMS-based SAW system cannot generate a large enough acoustic trapping force to hold swimming C. reinhardtii cells. At high input power, the temperature of this device rises rapidly, damaging (and possibly killing) the cells. The glass-based SAW/BAW hybrid system, on the other hand, can not only trap swimming C. reinhardtii at low input power, but also exhibits better thermal biocompatibility than the PDMS-based SAW system at high input power. Thus, a glass-based SAW/BAW device creates strong acoustic trapping forces in a biocompatible environment, providing a new solution to safely trap active microswimmers for research involving motile cells and microorganisms.


Assuntos
Acústica , Som , Fenômenos Mecânicos , Transdutores , Vibração
7.
Lab Chip ; 21(3): 521-533, 2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33507201

RESUMO

Acoustic microfluidics has emerged as a versatile solution for particle manipulation in medicine and biology. However, current technologies are largely confined to specialized research laboratories. The translation of acoustofluidics from research to clinical and industrial settings requires improved consistency and repeatability across different platforms. Performance comparisons will require straightforward experimental assessment tools that are not yet available. We introduce a method for characterizing acoustofluidic devices in real-time by exploiting the capacity of swimming microorganisms to respond to changes in their environment. The unicellular alga, Chlamydomonas reinhardtii, is used as an active probe to visualize the evolving acoustic pressure field within microfluidic channels and chambers. In contrast to more familiar mammalian cells, C. reinhardtii are simple to prepare and maintain, and exhibit a relatively uniform size distribution that more closely resembles calibration particles; however, unlike passive particles, these motile cells naturally fill complex chamber geometries and redistribute when the acoustic field changes or is turned off. In this way, C. reinhardtii cells offer greater flexibility than conventional polymer or glass calibration beads for in situ determination of device operating characteristics. To illustrate the technique, the varying spatial density and distribution of swimming cells are correlated to the acoustic potential to automatically locate device resonances within a specified frequency range. Peaks in the correlation coefficient of successive images not only identify the resonant frequencies for various geometries, but the peak shape can be related to the relative strength of the resonances. Qualitative mapping of the acoustic field strength with increasing voltage amplitude is also shown. Thus, we demonstrate that dynamically responsive C. reinhardtii enable real-time measurement and continuous monitoring of acoustofluidic device performance.


Assuntos
Acústica , Microfluídica , Animais
8.
Integr Biol (Camb) ; 12(9): 221-232, 2020 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-32930334

RESUMO

Tumor-infiltrating leukocytes, in particular macrophages, play an important role in tumor behavior and clinical outcome. The spectrum of macrophage subtypes ranges from antitumor 'M1'-type to protumor 'M2'-type macrophages. Tumor-associated macrophages (TAMs) typically display phenotypic features of both M1 and M2, and the population distribution is thought to be dynamic and evolves as the tumor progresses. However, our understanding of how TAMs impact the tumor microenvironment remains limited by the lack of appropriate 3D in vitro models that can capture cell-cell dynamics at high spatial and temporal resolution. Using our recently developed microphysiological 'tumor-on-a-chip' (TOC) device, we present here our findings on the impact of defined macrophage subsets on tumor behavior. The TOC device design contains three adjacent and connected chambers in which both the upper and lower chambers are loaded with tumor cells, whereas the central chamber contains a dynamic, perfused, living microvascular network. Introduction of human pancreatic or colorectal cancer cells together with M1-polarized macrophages significantly inhibited tumor growth and tumor-induced angiogenesis. Protein analysis and antibody-based neutralization studies confirmed that these effects were mediated through production of C-X-C motif chemokines (CXCL9), CXCL10 and CXCL11. By contrast, M2-macrophages mediated increased tumor cell migration into the vascularized chamber and did not inhibit tumor growth or angiogenesis. In fact, single-cell RNA sequencing showed that M2 macrophages further segregated endothelial cells into two distinct subsets, corresponding to static cells in vessels versus active cells involved in angiogenesis. The impact of M2 macrophages was mediated mostly by production of matrix metalloproteinase 7 and angiopoietin 2. In summary, our data demonstrate the utility of the TOC device to mechanistically probe biological questions in a 3D in vitro microenvironment.


Assuntos
Progressão da Doença , Dispositivos Lab-On-A-Chip , Macrófagos/citologia , Neoplasias/patologia , Motivos de Aminoácidos , Animais , Técnicas de Cultura de Células , Linhagem Celular Tumoral , Células Endoteliais , Humanos , Técnicas In Vitro , Linfócitos do Interstício Tumoral/citologia , Ativação de Macrófagos , Macrófagos/metabolismo , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Neovascularização Patológica/patologia , Fenótipo , RNA Citoplasmático Pequeno/metabolismo , RNA-Seq , Microambiente Tumoral , Macrófagos Associados a Tumor , Células U937
9.
Sci Rep ; 10(1): 3842, 2020 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-32123209

RESUMO

The development and physiologic role of small intestine (SI) vasculature is poorly studied. This is partly due to a lack of targetable, organ-specific markers for in vivo studies of two critical tissue components: endothelium and stroma. This challenge is exacerbated by limitations of traditional cell culture techniques, which fail to recapitulate mechanobiologic stimuli known to affect vessel development. Here, we construct and characterize a 3D in vitro microfluidic model that supports the growth of patient-derived intestinal subepithelial myofibroblasts (ISEMFs) and endothelial cells (ECs) into perfused capillary networks. We report how ISEMF and EC-derived vasculature responds to physiologic parameters such as oxygen tension, cell density, growth factors, and pharmacotherapy with an antineoplastic agent (Erlotinib). Finally, we demonstrate effects of ISEMF and EC co-culture on patient-derived human intestinal epithelial cells (HIECs), and incorporate perfused vasculature into a gut-on-a-chip (GOC) model that includes HIECs. Overall, we demonstrate that ISEMFs possess angiogenic properties as evidenced by their ability to reliably, reproducibly, and quantifiably facilitate development of perfused vasculature in a microfluidic system. We furthermore demonstrate the feasibility of including perfused vasculature, including ISEMFs, as critical components of a novel, patient-derived, GOC system with translational relevance as a platform for precision and personalized medicine research.


Assuntos
Capilares/crescimento & desenvolvimento , Técnicas de Cocultura/instrumentação , Intestino Delgado/citologia , Dispositivos Lab-On-A-Chip , Miofibroblastos/citologia , Humanos , Miofibroblastos/metabolismo , Oxigênio/metabolismo , Perfusão
10.
ACS Biomater Sci Eng ; 6(11): 6108-6116, 2020 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-33449635

RESUMO

Bioconjugates are important next-generation drugs and imaging agents. Assembly of these increasingly complex constructs requires precise control over processing conditions, which is a challenge for conventional manual synthesis. This inadequacy has motivated the pursuit of new approaches for efficient, controlled modification of high-molecular-weight biologics such as proteins, carbohydrates, and nucleic acids. We report a novel, hands-free, semiautomated platform for synthetic manipulation of biomolecules using acoustically responsive microparticles as three-dimensional reaction substrates. The microfluidic reactor incorporates a longitudinal acoustic trap that controls the chemical reactions within a localized acoustic field. Forces generated by this field immobilize the microscale substrates against the continuous flow of participating chemical reagents. Thus, the motion of substrates and reactants is decoupled, enabling exquisite control over multistep reaction conditions and providing high-yield, high-purity products with minimal user input. We demonstrate these capabilities by conjugating clinically relevant antibodies with a small molecule. The on-bead synthesis comprises capture of the antibody, coupling of a fluorescent tag, product purification, and product release. Successful capture and modification of a fluorescently labeled antibody are confirmed via fold increases of 49 and 11 in the green (antibody)- and red (small-molecule dye)-channel median intensities determined using flow cytometry. Antibody conjugates assembled on acoustically responsive, ultrasound-confined microparticles exhibit similar quality and quantity to those prepared manually by a skilled technician.


Assuntos
Imunoconjugados , Acústica , Anticorpos , Indicadores e Reagentes , Microfluídica
11.
mBio ; 10(6)2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31690680

RESUMO

Photoferrotrophy is a form of anoxygenic photosynthesis whereby bacteria utilize soluble or insoluble forms of ferrous iron as an electron donor to fix carbon dioxide using light energy. They can also use poised electrodes as their electron donor via phototrophic extracellular electron uptake (phototrophic EEU). The electron uptake mechanisms underlying these processes are not well understood. Using Rhodopseudomonas palustris TIE-1 as a model, we show that a single periplasmic decaheme cytochrome c, PioA, and an outer membrane porin, PioB, form a complex allowing extracellular electron uptake across the outer membrane from both soluble iron and poised electrodes. We observe that PioA undergoes postsecretory proteolysis of its N terminus to produce a shorter heme-attached PioA (holo-PioAC, where PioAC represents the C terminus of PioA), which can exist both freely in the periplasm and in a complex with PioB. The extended N-terminal peptide controls heme attachment, and its processing is required to produce wild-type levels of holo-PioAC and holo-PioACB complex. It is also conserved in PioA homologs from other phototrophs. The presence of PioAB in these organisms correlate with their ability to perform photoferrotrophy and phototrophic EEU.IMPORTANCE Some anoxygenic phototrophs use soluble iron, insoluble iron minerals (such as rust), or their proxies (poised electrodes) as electron donors for photosynthesis. However, the underlying electron uptake mechanisms are not well established. Here, we show that these phototrophs use a protein complex made of an outer membrane porin and a periplasmic decaheme cytochrome (electron transfer protein) to harvest electrons from both soluble iron and poised electrodes. This complex has two unique characteristics: (i) it lacks an extracellular cytochrome c, and (ii) the periplasmic decaheme cytochrome c undergoes proteolytic cleavage to produce a functional electron transfer protein. These characteristics are conserved in phototrophs harboring homologous proteins.


Assuntos
Proteínas de Bactérias/metabolismo , Transporte Biológico/fisiologia , Transporte de Elétrons/fisiologia , Ferro/metabolismo , Porinas/metabolismo , Dióxido de Carbono/metabolismo , Citocromos c/metabolismo , Eletrodos , Elétrons , Periplasma/metabolismo , Fotossíntese/fisiologia , Rodopseudomonas/metabolismo
12.
Soft Matter ; 15(21): 4266-4275, 2019 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-30968924

RESUMO

Functional cilia and flagella are crucial to the propulsion of physiological fluids, motile cells, and microorganisms. Motility assessment of individual cells allows discrimination of normal from dysfunctional behavior, but cell-scale analysis of individual trajectories to represent a population is laborious and impractical for clinical, industrial, and even research applications. We introduce an assay that quantifies swimming capability as a function of the variation in polar moment of inertia of cells released from an acoustic trap. Acoustic confinement eliminates the need to trace discrete trajectories and enables automated analysis of hundreds of cells in minutes. The approach closely approximates the average speed estimated from the mean squared displacement of individual cells for wild-type Chlamydomonas reinhardtii and two mutants (ida3 and oda5) that display aberrant swimming behaviors. Large-population acoustic trap-and-release rapidly differentiates these cell types based on intrinsic motility, which provides a highly sensitive and efficient alternative to conventional particle tracing.


Assuntos
Acústica , Chlamydomonas reinhardtii/citologia , Técnicas Citológicas/métodos , Chlamydomonas reinhardtii/genética , Cílios/metabolismo , Análise de Elementos Finitos , Flagelos/metabolismo , Mutação , Fatores de Tempo
13.
Nat Commun ; 10(1): 1355, 2019 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-30902976

RESUMO

Extracellular electron uptake (EEU) is the ability of microbes to take up electrons from solid-phase conductive substances such as metal oxides. EEU is performed by prevalent phototrophic bacterial genera, but the electron transfer pathways and the physiological electron sinks are poorly understood. Here we show that electrons enter the photosynthetic electron transport chain during EEU in the phototrophic bacterium Rhodopseudomonas palustris TIE-1. Cathodic electron flow is also correlated with a highly reducing intracellular redox environment. We show that reducing equivalents are used for carbon dioxide (CO2) fixation, which is the primary electron sink. Deletion of the genes encoding ruBisCO (the CO2-fixing enzyme of the Calvin-Benson-Bassham cycle) leads to a 90% reduction in EEU. This work shows that phototrophs can directly use solid-phase conductive substances for electron transfer, energy transduction, and CO2 fixation.


Assuntos
Ciclo do Carbono , Dióxido de Carbono/metabolismo , Elétrons , Espaço Extracelular/metabolismo , Processos Fototróficos , Rodopseudomonas/metabolismo , Hidrogênio/metabolismo , Espaço Intracelular/metabolismo , Modelos Biológicos , Oxirredução , Fotossíntese , Rodopseudomonas/crescimento & desenvolvimento , Ribulose-Bifosfato Carboxilase/metabolismo
14.
Artigo em Inglês | MEDLINE | ID: mdl-30047875

RESUMO

Acoustic microfluidic devices encompass mechanical, fluidic, and electromechanical domains. Complicated multidomain interactions require the consideration of each individual material domain, as well as coupled behaviors to achieve optimal performance. Herein, we report the co-optimization of components comprising an ultrasonic droplet generator to achieve the high-efficiency liquid atomization for operation in the 0.5-2.5-MHz frequency range. Due to the complexity of the real system, simplified 2-D representations of the device are investigated using an experimentally validated finite element analysis model. Ejection modes (i.e., frequencies at which droplet generation is predicted) are distinguished by maxima in the local pressure at the tips of an array of triangular nozzles. Resonance behaviors of the transducer assembly and fluid-filled chamber are examined to establish optimal geometric combinations concerning the chamber pressure field. The analysis identifies how domain geometries affect pressure field uniformity, broadband operation, and tip pressure amplitude. Lower frequency modes are found to focus the acoustic energy at the expense of field uniformity within the nozzle array. Resonance matching yields a nearly threefold increase in maximum attainable tip pressure amplitude. Significantly, we establish a set of design principles for these complex devices, which resembles a classical half-wave transducer, quarter-wave matching layer, and half-wave chamber layered system.

15.
Sci Rep ; 8(1): 3727, 2018 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-29487375

RESUMO

Delivery of large and structurally complex target molecules into cells is vital to the emerging areas of cellular modification and molecular therapy. Inadequacy of prevailing in vivo (viral) and in vitro (liposomal) gene transfer methods for delivery of proteins and a growing diversity of synthetic nanomaterials has encouraged development of alternative physical approaches. Efficacy of injury/diffusion-based delivery via shear mechanoporation is largely insensitive to cell type and target molecule; however, enhanced flexibility is typically accompanied by reduced gene transfer effectiveness. We detail a method to improve transfection efficiency through coordinated mechanical disruption of the cell membrane and electrophoretic insertion of DNA to the cell interior. An array of micromachined nozzles focuses ultrasonic pressure waves, creating a high-shear environment that promotes transient pore formation in membranes of transmitted cells. Acoustic Shear Poration (ASP) allows passive cytoplasmic delivery of small to large nongene macromolecules into established and primary cells at greater than 75% efficiency. Addition of an electrophoretic action enables active transport of target DNA molecules to substantially augment transfection efficiency of passive mechanoporation/diffusive delivery without affecting viability. This two-stage poration/insertion method preserves the compelling flexibility of shear-based delivery, yet substantially enhances capabilities for active transport and transfection of plasmid DNA.


Assuntos
Eletroforese/métodos , Técnicas de Transferência de Genes , Transfecção/métodos , Ondas Ultrassônicas , Linhagem Celular , Permeabilidade da Membrana Celular , DNA/administração & dosagem , Difusão , Eletroforese/instrumentação , Eletroporação , Humanos , Substâncias Macromoleculares/administração & dosagem , Transfecção/instrumentação
16.
PLoS One ; 12(8): e0182929, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28797120

RESUMO

3D printing has the potential to deliver personalized implants and devices for obstetric and gynecologic applications. The aim of this study is to engineer customizable and biodegradable 3D printed implant materials that can elute estrogen and/or progesterone. All 3D constructs were printed using polycaprolactone (PCL) biodegradable polymer laden with estrogen or progesterone and were subjected to hormone-release profile studies using ELISA kits. Material thermal properties were tested using thermogravimetric analysis and differential scanning calorimetry. The 3D printed constructs showed extended hormonal release over a one week period. Cytocompatibility and bioactivity were assessed using a luciferase assay. The hormone-laden 3D printed constructs demonstrated an increase in luciferase activity and without any deleterious effects. Thermal properties of the PCL and hormones showed degradation temperatures above that of the temperature used in the additive manufacturing process-suggesting that 3D printing can be achieved below the degradation temperatures of the hormones. Sample constructs in the shape of surgical meshes, subdermal rods, intrauterine devices and pessaries were designed and printed. 3D printing of estrogen and progesterone-eluting constructs was feasible in this proof of concept study. These custom designs have the potential to act as a form of personalized medicine for drug delivery and optimized fit based on patient-specific anatomy.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis/química , Sistemas de Liberação de Medicamentos/instrumentação , Estrogênios/administração & dosagem , Poliésteres/química , Progesterona/administração & dosagem , Desenho de Equipamento , Feminino , Humanos , Dispositivos Intrauterinos Medicados , Pessários , Impressão Tridimensional , Telas Cirúrgicas
17.
J Lab Autom ; 19(1): 1-18, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23813915

RESUMO

Effective intracellular delivery is a significant impediment to research and therapeutic applications at all processing scales. Physical delivery methods have long demonstrated the ability to deliver cargo molecules directly to the cytoplasm or nucleus, and the mechanisms underlying the most common approaches (microinjection, electroporation, and sonoporation) have been extensively investigated. In this review, we discuss established approaches, as well as emerging techniques (magnetofection, optoinjection, and combined modalities). In addition to operating principles and implementation strategies, we address applicability and limitations of various in vitro, ex vivo, and in vivo platforms. Importantly, we perform critical assessments regarding (1) treatment efficacy with diverse cell types and delivered cargo molecules, (2) suitability to different processing scales (from single cell to large populations), (3) suitability for automation/integration with existing workflows, and (4) multiplexing potential and flexibility/adaptability to enable rapid changeover between treatments of varied cell types. Existing techniques typically fall short in one or more of these criteria; however, introduction of micro-/nanotechnology concepts, as well as synergistic coupling of complementary method(s), can improve performance and applicability of a particular approach, overcoming barriers to practical implementation. For this reason, we emphasize these strategies in examining recent advances in development of delivery systems.


Assuntos
Sistemas de Liberação de Medicamentos , Espaço Intracelular , Nanotecnologia/métodos , Animais , Humanos
18.
Electrophoresis ; 29(16): 3456-65, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18646283

RESUMO

A method is described for an aptamer-based affinity assay using a combination of two nonconventional techniques, temperature gradient focusing (TGF) and field-amplified continuous sample injection TGF (FACSI-TGF), with fluorescence detection. Human immunodeficiency virus reverse transcriptase (HIVRT) is used as the protein target for the assay. The TGF and FACSI-TGF assays are compared to similar results obtained with conventional CE. A range of starting aptamer concentrations are used to determine the optimal LOD for human immunodeficiency virus reverse transcriptase (HIVRT) using each approach. The results indicate that the LODs for HIVRT obtained with TGF and FACSI-TGF are comparable to or even lower than the LODs obtained with conventional CE in spite of the inferior detector used for the TGF and FACSI-TGF assays (arc lamp and low-cost CCD for TGF versus LIF with PMT for CE). It is hypothesized that this is due to the greater reproducibility of the TGF and FACSI-TGF techniques since they do not employ a defined sample injection. The lowest LOD achieved with the new aptamer assay approach is more than an order of magnitude lower than that reported for a similar CE-based aptamer assay for the same target.


Assuntos
Aptâmeros de Nucleotídeos/química , Transcriptase Reversa do HIV/análise , Temperatura , Eletroforese Capilar/métodos , Humanos
19.
J Am Soc Mass Spectrom ; 19(9): 1320-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18650100

RESUMO

The internal energy deposition of a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE), with and without the application of a DC charging potential, is compared with equivalent experiments for Venturi-assisted electrospray ionization (ESI) using the "survival yield" method on a series of para-substituted benzylpyridinium salts. Under conditions previously shown to provide maximum ion yields for standard compounds, the observed mean internal energies were nearly identical (1.93-2.01 eV). Operation of AMUSE without nitrogen flow to sustain the air amplifier focusing effect generated energetically colder ions with mean internal energies that were up to 39% lower than those for ESI. A balance between improved ion transfer, adequate desolvation, and favorable ion energetics was achieved by selection of optimum operational ranges for the parameters that most strongly influence the ion population: the air amplifier gas flow rate and API capillary temperature. Examination of the energy landscapes obtained for combinations of these parameters showed that a low internal energy region (

Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Desenho de Equipamento , Compostos de Piridínio/química , Termodinâmica , Ultrassom
20.
Biomed Microdevices ; 10(2): 299-308, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17994280

RESUMO

We report on development and experimental characterization of a novel cell manipulation device-the electrosonic ejector microarray-which establishes a pathway for drug and/or gene delivery with control of biophysical action on the length scale of an individual cell. The device comprises a piezoelectric transducer for ultrasound wave generation, a reservoir for storing the sample mixture and a set of acoustic horn structures that form a nozzle array for focused application of mechanical energy. The nozzles are micromachined in silicon or plastic using simple and economical batch fabrication processes. When the device is driven at a particular resonant frequency of the acoustic horn structures, the sample mixture of cells and desired transfection agents/molecules suspended in culture medium is ejected from orifices located at the nozzle tips. During sample ejection, focused mechanical forces (pressure and shear) are generated on a microsecond time scale (dictated by nozzle size/geometry and ejection velocity) resulting in identical "active" microenvironments for each ejected cell. This process enables a number of cellular bioeffects, from uptake of small molecules and gene delivery/transfection to cell lysis. Specifically, we demonstrate successful calcein uptake and transfection of DNA plasmid encoding green fluorescent protein (GFP) into human malignant glioma cells (cell line LN443) using electrosonic microarrays with 36, 45 and 50 mum diameter nozzle orifices and operating at ultrasound frequencies between 0.91 and 0.98 MHz. Our results suggest that efficacy and the extent of bioeffects are mainly controlled by nozzle orifice size and the localized intensity of the applied acoustic field.


Assuntos
Acústica/instrumentação , Separação Celular/instrumentação , Sistemas de Liberação de Medicamentos/instrumentação , Injeções a Jato/instrumentação , Análise em Microsséries/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Transfecção/instrumentação , Separação Celular/métodos , Sistemas de Liberação de Medicamentos/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Injeções a Jato/métodos , Análise em Microsséries/métodos , Micromanipulação/instrumentação , Micromanipulação/métodos , Transfecção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA