Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Clin Spine Surg ; 30(3): E291-E296, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28323714

RESUMO

STUDY DESIGN: Eleven patients with painful osteoporotic vertebral fractures who underwent kyphoplasty using calcium phosphate (CaP) cement were followed up for 1 week, 1, 2, and 3 years in a monocentric, nonrandomized, noncontrolled retrospective trial. OBJECTIVE: This study investigates long-term radiomorphologic features of intraosseous CaP cement implants and of extraosseous CaP cement leakages for up to 3 years after implantation by kyphoplasty. SUMMARY OF BACKGROUND DATA: Kyphoplasty is frequently used for the treatment of painful osteoporotic fractures. Of the materials available, CaP is frequently used as a filling material. Resorption of this material is frequently observed, although clinical outcome is comparable with other cements. METHODS: Kyphoplasty utilizing CaP cement was performed in 11 patients with painful osteoporotic vertebral fractures. All patients received a pharmacological antiosteoporosis treatment consisting of calcium, vitamin D, and a standard dose of oral bisphosphonates. Radiomorphologic measurements, pain, and mobility were assessed. RESULTS: Intraosseous and extraosseous CaP cement volumes decreased significantly over 3 years. However, vertebral stability as determined by a constant vertebral body height and the sagittal index was not impaired. Pain improved significantly 2 years after implantation and the mobility scores 1 year after kyphoplasty at least until the third year. CONCLUSIONS: Intravertebral CaP cement implants are resorbed slowly over time without jeopardizing stability and clinical outcomes most likely because of a slowly progressing osseous replacement. Extraosseous CaP cement material because of leakages during the kyphoplasty procedure is almost completely resorbed as early as 2 years after the leakage occurred. Therefore, CaP cement is an important alternative to PMMA-based cement materials utilized for kyphoplasty of osteoporotic vertebral fractures.


Assuntos
Cimentos Ósseos/uso terapêutico , Fosfatos de Cálcio/uso terapêutico , Cifoplastia/métodos , Fraturas por Osteoporose/cirurgia , Adulto , Idoso , Peso Corporal , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Movimento , Osteoporose , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Dor/etiologia , Dor/cirurgia , Tomógrafos Computadorizados , Resultado do Tratamento , Escala Visual Analógica
2.
Acta Orthop Belg ; 83(4): 497-505, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30423654

RESUMO

Deformation of the spine following vertebral compression fracture (VCF) can be associated with severe spinal dysfunction. Anatomical restoration is described as the complete reduction and stable fixation of the fracture with the goal to restore the pre-fracture local and global spine properties. The essential need to obtain endplate reduction, and consider the whole vertebral body in the management of vertebral fractures is pointed out. A new 3D imaging technique is described. A new assessment method based on CT scans 3D reconstructions was developed. This new method was used to assess the anatomical restoration of the fractured vertebrae. A procedure consisting in placing two expandable titanium implants for fracture reduction, together with stabilization with a high viscosity PMMA cement was used to demonstrate the method. The cases presented here are demonstrating that this 3D-mapping software is a tool which can address the lack of a valid, reproducible and user-friendly method to evaluate the anatomical restoration in VCF. The evaluation of the anatomical restoration of the fractured vertebrae raises some issues in terms of interpretation because of a lack of consensus in the existing reporting methods. A 3D-reconstruction method, using CT scans and a newly-developed software, is proposed to evaluate the anatomical restoration in a clear, valid, reproducible and user-friendly way.


Assuntos
Fraturas por Compressão/cirurgia , Imageamento Tridimensional , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral/anatomia & histologia , Coluna Vertebral/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Coluna Vertebral/cirurgia
3.
J Orthop Surg Res ; 8: 16, 2013 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-23758869

RESUMO

BACKGROUND: Calcium phosphate cements are used frequently in orthopedic and dental surgeries. Strontium-containing drugs serve as systemic osteoblast-activating medication in various clinical settings promoting mechanical stability of the osteoporotic bone. METHODS: Strontium-containing calcium phosphate cement (SPC) and calcium phosphate cement (CPC) were compared regarding their local and systemic effects on bone tissue in a standard animal model for osteoporotic bone. A bone defect was created in the distal femoral metaphysis of 60 ovariectomized Sprague-Dawley rats. CPC and SPC were used to fill the defects in 30 rats in each group. Local effects were assessed by histomorphometry at the implant site. Systemic effects were assessed by bone mineral density (BMD) measurements at the contralateral femur and the spine. RESULTS: Faster osseointegration and more new bone formation were found for SPC as compared to CPC implant sites. SPC implants exhibited more cracks than CPC implants, allowing more bone formation within the implant. Contralateral femur BMD and spine BMD did not differ significantly between the groups. CONCLUSIONS: The addition of strontium to calcium phosphate stimulates bone formation in and around the implant. Systemic release of strontium from the SPC implants did not lead to sufficiently high serum strontium levels to induce significant systemic effects on bone mass in this rat model.


Assuntos
Cimentos Ósseos/farmacologia , Fosfatos de Cálcio/farmacologia , Osseointegração/efeitos dos fármacos , Osteoporose/fisiopatologia , Estrôncio/farmacologia , Animais , Densidade Óssea/fisiologia , Conservadores da Densidade Óssea/sangue , Conservadores da Densidade Óssea/farmacologia , Avaliação Pré-Clínica de Medicamentos/métodos , Feminino , Osteogênese/efeitos dos fármacos , Ovariectomia , Projetos Piloto , Ratos , Ratos Sprague-Dawley , Estrôncio/sangue
4.
J Surg Oncol ; 105(7): 679-86, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21960293

RESUMO

BACKGROUND: This retrospective study of 73 myeloma patients with painful vertebral lesions compares clinical and radiomorphological outcomes up to 2 years after additional kyphoplasty, radiation therapy or systemic treatment only. METHODS: We assessed pain, disability and radiomorphological parameters by visual analogue scale (VAS 0-100), Oswestry Disability Index and by re-evaluating available follow-up X-rays, respectively, in patients that were treated according to a clinical pathway. RESULTS: After 2 years the VAS score was reduced in all groups by 66 ± 8.2 (kyphoplasty), 35 ± 10.5 (radiation therapy) and 38 ± 20.5 (systemic therapy only). Only after kyphoplasty we observed a significantly reduced Oswestry Disability Index after 1 year (P < 0.001). Vertebral height remained stable after kyphoplasty (P = 0.283), in contrast to a progressive height loss in the other groups (P = 0.013 and P = 0.015 for radiation and systemic therapy only, respectively). Two years after kyphoplasty and radiotherapy the overall vertebral fracture incidence was significantly decreased as compared to the group after systemic therapy only (9.7% of all thoracic and lumbar vertebrae had new vertebral fractures after systemic therapy only, 2% after kyphoplasty (P < 0.001), 4.8% after radiation (P = 0.032)). CONCLUSION: Additional kyphoplasty was more effective than additional radiation or systemic therapy in terms of pain relief, reduction of pain associated disability and reduction of fracture incidence of the entire lumbar and thoracic spine.


Assuntos
Cifoplastia/métodos , Mieloma Múltiplo/cirurgia , Idoso , Feminino , Humanos , Cifoplastia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/patologia , Medição da Dor , Projetos Piloto , Estudos Retrospectivos
5.
J Vasc Interv Radiol ; 21(5): 701-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20304677

RESUMO

PURPOSE: Kyphoplasty immediately improves pain and mobility in patients with painful osteoporotic vertebral fractures, but long-term clinical outcomes are still unclear. This controlled trial evaluates pain, mobility and fracture incidence 3 years after kyphoplasty. MATERIALS AND METHODS: Kyphoplasty was performed in 40 patients with painful osteoporotic vertebral fractures; 20 patients who were selected for kyphoplasty but chose not to undergo the procedure served as controls. All patients received pharmacologic antiosteoporosis treatment, pain medication, and physiotherapy. Pain (visual analog scale of 0-100), mobility (European Vertebral Osteoporosis Study questionnaire score of 0-100), and incident vertebral fractures were assessed at baseline, postprocedurally, and after 12 and 36 months. RESULTS: Pain score improved after kyphoplasty from 73.8 to 55.9 (immediately after kyphoplasty), 55.6 (12 months), and 54.0 (36 months; P < .001). Pain score in the control group changed from 66.4 to 65.7 at 12 months and 64.0 at 36 months (P = .521). The pain score of the kyphoplasty group was significantly improved versus controls after 36 months (P = .023). Mobility score improved after kyphoplasty from 43.8 to 54.2 (immediately after kyphoplasty), 54.5 (12 months), and 54.8 (36 months; P = .0008) and remained increased (P = .308) compared with controls (39.8 immediately after kyphoplasty, 44.3 at 12 months, and 43.6 at 36 months). The incidence of new vertebral fractures after kyphoplasty was significantly reduced versus controls after 3 years (P = .0341). CONCLUSIONS: Kyphoplasty reduces pain and improves mobility as long as 3 years after the procedure. The long-term risk of new vertebral fractures after kyphoplasty of chronically painful vertebral fractures is reduced versus controls.


Assuntos
Dor nas Costas/etiologia , Dor nas Costas/cirurgia , Fraturas Espontâneas/etiologia , Osteoporose/complicações , Osteoporose/cirurgia , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Idoso , Feminino , Fraturas Espontâneas/cirurgia , Humanos , Estudos Longitudinais , Masculino , Resultado do Tratamento
6.
Clin Lymphoma Myeloma ; 9(5): 375-80, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19858057

RESUMO

INTRODUCTION: Only in recent years has balloon kyphoplasty gained significance in the treatment of vertebral fractures as an adequate minimally invasive vertebral stabilization technique. Kyphoplasty has also increasingly been used to treat vertebral osteolyses caused by multiple myeloma (MM). PATIENTS AND METHODS: In our cohort of 76 patients with MM with a total of 190 vertebral fractures treated with kyphoplasty, we performed a 30-day postoperative analysis of cement leakage, neurologic symptoms, pulmonary embolism, and infections. RESULTS: Painful osteolytic or fractured vertebrae or even imminent vertebral instability caused by osteolyses were seen as indications for kyphoplasty. One case of pulmonary embolism was observed because of cement leakage as the only postoperative complication. CONCLUSION: By careful interdisciplinary indication setting and a standardized treatment model, kyphoplasty presents a very safe and effective procedure for the treatment of vertebral osteolyses and fractures caused by MM.


Assuntos
Mieloma Múltiplo/cirurgia , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Orthopedics ; 32(2): 90, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19301801

RESUMO

In our cohort of 555 patients with a total of 1150 vertebral fractures treated with kyphoplasty we performed a 30-day postoperative analysis of cement leakage, neurological symptoms, pulmonary embolism, and infections. In our department, 22% of kyphoplasties were performed with calcium phosphate cement and the remainder with polymethylmethacrylate. All patients were initially assessed by an interdisciplinary kyphoplasty colloquium, composed of consultants in traumatology, radiology, and endocrinology. Indications included fresh traumatic vertebral fractures; painful sintered osteoporotic vertebrae; osteolysis and painful vertebral body collapse caused by multiple myelomas; and lymphomas and pathological fractures due to metastases of malignant tumors (prostate cancer, breast cancer, ovarian cancer, and malignant melanoma) or benign vertebral tumors (hemangioma). Contraindications included patients with instability of the posterior wall and/or pedicles, an infection of the fractured vertebra, a severe hemorrhagic diathesis, known allergies to the cements, pregnancy, and ASA score of 4. The standard postoperative computed tomography scan of the kyphoplasty-treated vertebrae revealed a dorsal cement leakage in 38 vertebrae representing 3.3% of all levels. A permanent monoparesis of the left leg, 2 cases of temporary neurological deficits, 2 cases of hemorrhage, and 1 asymptomatic pulmonary embolism were observed as postoperative complications. We observed no complications relating to polymethylmethacrylate described in the literature. By careful interdisciplinary indication setting and a standardized treatment model, kyphoplasty presents a safe and effective procedure for the treatment of various vertebral fractures.


Assuntos
Complicações Intraoperatórias/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Coluna Vertebral/epidemiologia , Vertebroplastia/efeitos adversos , Adulto Jovem
8.
Spine (Phila Pa 1976) ; 33(11): 1284-90, 2008 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-18469705

RESUMO

STUDY DESIGN: A comparative prospective trial evaluating 3-year outcome. OBJECTIVE: To compare clinical and morphologic outcomes as well as follow-up fractures after kyphoplasty of painful osteoporotic vertebral fractures with calcium-phosphate (CaP) cement (group 1) and with polymethylmethacrylate (PMMA)-cement (group 2). SUMMARY OF BACKGROUND DATA: CaP cements seem to be an alternative material for usage in kyphoplasty of vertebral fractures. CaP cements are biodegradable and replaceable by newly formed bone after implantation. Concerns have been raised with regard to the stability of resorbable CaP-cements after implantation into vertebrae post kyphoplasty. Calcibon is a possible CaP cement, which exhibited adequate stability in short-term observations. MATERIALS AND METHODS: Kyphoplasty was performed in 40 consecutive patients with primary osteoporosis and painful vertebral fractures, 20 received CaP-cement, 20 were treated with PMMA-cement. All patients received a pharmacological antiosteoporosis treatment (1000 mg calcium, 1000 IU vitamin D3, and oral aminobisphosphonate), pain medication, and physiotherapy. Pain (visual analog scale [VAS]; range, 0-100), mobility (EVOS-score; range, 0-100) and radiomorphologic measurements were assessed at baseline and after 6, 12, and 36 months. RESULTS: There were no statistically significant differences between the CaP and PMMA-cement group regarding VAS-scores, EVOS-scores, or height-restoration at any time point. Furthermore, there was no significant difference in the occurrence of vertebral follow-up fractures between both groups during the 3-year follow-up period. CONCLUSION: CaP cement, e.g., Calcibon, is as effective and safe as conventional PMMA-cement with regard to immediate and sustained pain reduction and improvement of mobility after kyphoplasty of patients with painful osteoporotic vertebral fractures. CaP cement has the potential of being resorbed and replaced by newly formed bone tissue; thus, it seems to be a promising alternative for PMMA also in younger patients with painful vertebral fractures.


Assuntos
Fosfatos de Cálcio/administração & dosagem , Osteoporose/cirurgia , Dor/cirurgia , Polimetil Metacrilato/administração & dosagem , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia/métodos , Idoso , Cimentos Ósseos/uso terapêutico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/patologia , Dor/complicações , Dor/patologia , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/patologia , Tempo , Resultado do Tratamento
9.
J Mater Sci Mater Med ; 19(1): 33-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17569013

RESUMO

The purpose of our study was to test the effectiveness of Ostim nanocrystalline hydroxyapatite paste and Cerabone ceramic by treating a critical size bone defect (CSD) on the right foreleg of a white New Zealand rabbit. Evaluation was carried out by comparing four groups each with a different CSD filling: an only OSTIM bone filling, an only Cerabone filling, an OSTIM-Cerabone combination, and a control group with no filling of the CSD. The results of this study display a rapid and uniform bone ingrowth following the CSD filling with Ostim. The histological and histomorphometrical data have shown similarly excellent results for both the Ostim and Cerabone-Ostim groups. The control group faired poorly in comparison, as three cases of non-union were observed and none of the defects were totally refilled with fresh bone within 60 days. The successful bone healing with osseous consolidation verifies the importance of the nanocrystalline hydroxyapatite in the treatment of metaphyseal osseous volume defects in the metaphyseal spongiosa.


Assuntos
Materiais Biocompatíveis/química , Cerâmica/química , Durapatita/química , Consolidação da Fratura , Nanopartículas/química , Animais , Cimentos Ósseos/química , Substitutos Ósseos/química , Osso e Ossos/metabolismo , Fraturas Ósseas/terapia , Teste de Materiais , Osseointegração , Coelhos
10.
Eur Radiol ; 17(9): 2248-52, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17522865

RESUMO

This study investigated the prevalence of the intravertebral vacuum phenomenon (IVP) and osteonecroses in vertebral compression fractures (VCFs). We therefore performed an histological analysis of biopsies obtained from VCFs prior to balloon kyphoplasty. Computed tomography (CT) scans were reviewed regarding the presence of an IVP (i.e. cleft sign, Kümmell disease). We reviewed the data of 266 consecutive patients treated by balloon kyphoplasty in 501 procedures from 2002 to 2004. From 180 patients (68%) we obtained adequate bone tissue for histological evaluation. Biopsy specimens were analysed regarding the presence of osteoporosis, infection, malignancy and osteonecrosis. CT scans of all 180 patients were reviewed for presence of an IVP. Histological examination revealed 135 (75%) osteoporoses, 20 (11%) neoplasms, 12 (7%) trauma cases and 13 (7%) osteonecroses. An IVP was present in 12 (7%) patients. There was a significant association of osteonecrosis and IVP (P < 0.0001). Eleven of 12 patients with a vacuum phenomenon showed an osteonecrosis on histology, whereas 11 of 13 patients with osteonecrosis showed an IVP on CT. The IVP is a specific sign of osteonecrosis in vertebral compression fractures (sensitivity 85%, specificity 99%, positive predictive value 91%). Our findings strongly support the thesis that an IVP indicates local bone ischemia associated with a non-healing vertebral collapse and pseudarthrosis.


Assuntos
Fraturas por Compressão/diagnóstico por imagem , Disco Intervertebral/patologia , Osteonecrose/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Biópsia , Feminino , Fraturas por Compressão/patologia , Fraturas por Compressão/cirurgia , Gases , Humanos , Disco Intervertebral/diagnóstico por imagem , Masculino , Osteonecrose/patologia , Osteonecrose/cirurgia , Valor Preditivo dos Testes , Fraturas da Coluna Vertebral/patologia , Fraturas da Coluna Vertebral/cirurgia , Estatísticas não Paramétricas
11.
Resuscitation ; 73(3): 362-73, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17287064

RESUMO

INTRODUCTION: Successful management of emergency patients with multiple trauma in the hospital resuscitation room depends on the immediate diagnosis and rapid treatment of the most life-threatening injuries. In order to reduce the time spent in the resuscitation room, an in-hospital algorithm was developed in an interdisciplinary team approach with respect to local structures. The aim of the study was to analyse whether this algorithm affects the interval between hospital admission and the completion of diagnostic procedures and the start of life-saving interventions. Moreover, in-hospital mortality was investigated before and after the algorithm was introduced. MATERIAL AND METHODS: In this prospective study, all consecutive trauma patients in the resuscitation room were investigated before (group I, 01/04-10/04) and after (group II, 01/05-11/05) introduction of the algorithm. The times between hospital admission and the end of the diagnostic procedures (ultrasound [sono], chest X-ray [CF], and cranial computed tomography [CCT]), and between hospital admission and the start of life-saving interventions were registered and in-hospital mortality analysed. RESULTS: In the study period, 170 patients in group I and 199 patients in group II were investigated. Injury severity score (ISS) were comparable between the two groups. The intervals between admission and completion of diagnostic procedures were significantly lower after the algorithm was introduced (mean+/-S.D.): sono (11 +/- 10 min versus 7 +/- 6 min, p < 0.05), CF (21 +/- 12 min versus 12 +/- 9 min, p < 0.01), and CCT (55 +/- 27 min versus 32 +/- 14 min, p < 0.01). Moreover, the interval to the start of life-saving interventions was significantly shorter (126 +/- 90 min versus 51 +/- 20 min, p < 0.01). After introducing the algorithm, in-hospital mortality was reduced significantly from 33.3% to 16.7% (p < 0.05) in the most severely injured patients (ISS>or=25). CONCLUSION: The introduction of an algorithm for early management of emergency patients significantly reduced the time spent in the resuscitation room. The periods to completion of sono, CF, and CCT, respectively, and the start of life-saving interventions were significantly shorter after introduction of the algorithm. Moreover, introduction of the algorithm reduced mortality in the most severely injured patients. Although further investigations are needed to evaluate the effects of the Heidelberg treatment algorithm in terms of outcome and mortality, the time reduction in the resuscitation room seems to be beneficial.


Assuntos
Traumatismo Múltiplo/diagnóstico , Ressuscitação/normas , Centros de Traumatologia/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Criança , Pré-Escolar , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/mortalidade , Traumatismo Múltiplo/cirurgia , Estudos Prospectivos , Fatores de Tempo
12.
Eur J Trauma Emerg Surg ; 33(3): 262-7, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26814490

RESUMO

Secondary dislocation, non-union, re-fracture and implant failure are generally known complications after intramedullary fixation of proximal femur fractures with the PFN(®) (Synthes GmbH, Solothurn, Switzerland). The goal of our study was to assess the impact of patient- and treatment-specific risk factors on these complications. Complex fracture type and poor bone quality were defined as patient-specific risk factors. Inadequate fracture reduction and implant position were defined as treatment-specific risk factors. One hundred and seventy-eight cases were retrospectively analyzed. All patients had at least one clinical and radiological follow-up examination 3-6 months after the operation. Fifty percent of the patients were available for one more follow-up at least 1 year after the operation. All patients without patient-specific risk factors had a good outcome, irrespective of whether treatmentspecific risk factors were present or absent. In 153 of the 178 cases, patients had a complex type of fracture and/or poor bone quality. Of these patients, 27 (15.2%) had a poor result. Twenty-four of these patients needed re-operation within 6 months. Complication rate in these patients highly depended on treatment-specific risk factors. We conclude that the PFN is a secure implant for the stabilization of simple cases. Stabilization of complex proximal femoral fractures with the PFN, however, has a relevant complication rate and should therefore be considered a challenge.

13.
J Foot Ankle Surg ; 45(5): 322-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16949530

RESUMO

The purpose of this investigation was to evaluate the feasibility of a nanocrystalline hydroxyapatite compound in the treatment of calcaneal fractures with osseous defects after reduction. The study included 21 patients, representing 24 closed intraarticular calcaneus fractures with large defects remaining after operative reduction. All cases were supplemented with the hydroxyapatite bone substitute and stabilized with a calcaneal honeycomb plate. Radiographs were taken at 6 weeks, 12 weeks, 6 months, and 1 year postoperatively, with specific attention given to measurement of Gissane's angle, Böhler's angle, and calcaneal height. A postoperative subjective and objective evaluation of the fracture, using the Creighton Nebraska Health Foundation scale, was performed 1 year postoperatively. Böhler's angle improved from a mean 8.6 +/- 5.3 degrees preoperatively to an immediate postoperative mean result of 31.5 +/- 6.5 degrees and 27.7 +/- 8.6 1 year postoperatively. The mean Creighton-Nebraska functional score was 86 +/- 10 at the 1-year follow-up evaluation. These results suggest that open reduction with plate fixation combined with nanocrystalline hydroxyapatite augmentation presents a good and reliable surgical technique for treatment of calcaneus fractures.


Assuntos
Substitutos Ósseos , Calcâneo/lesões , Durapatita , Fraturas Ósseas/cirurgia , Nanopartículas , Adulto , Idoso , Calcâneo/diagnóstico por imagem , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
14.
Arch Orthop Trauma Surg ; 126(8): 533-40, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16835779

RESUMO

INTRODUCTION: It is a generally accepted standard surgical practice to fill-in the metaphyseal defect zones resulting from the reduction of tibia compression fractures. The development of various innovative bone substitutes is also currently on the increase. MATERIALS AND METHODS: In our prospective study, we used Ostim, a novel resorbable nanocrystalline hydroxyapatite paste, together with Cerabone, a solid hydroxyapatite ceramic, in combination with angularly stable osteosynthesis to treat 24 tibia compression fractures. Types B2 and B3, as well as types C2 and C3 fractures, according to the AO classification, were included in the study. RESULTS: The mean total range of joint motion in terms of flexion and extension was improved from the immediate postoperative value of 79 +/- 14 degrees to 97 +/- 13 degrees at 6 weeks after surgery, to 109 +/- 16 degrees at 3 months, and finally to 118 +/- 17 degrees at 1 year. In three patients, a delayed wound healing was observed as a local complication. CONCLUSION: The use of the Ostim and Cerabone combination is an effective method in treating tibia compression fractures with large defect zones left after reduction.


Assuntos
Cimentos Ósseos/uso terapêutico , Substitutos Ósseos/uso terapêutico , Fraturas por Compressão/cirurgia , Hidroxiapatitas/uso terapêutico , Nanopartículas/uso terapêutico , Fraturas da Tíbia/cirurgia , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Cerâmica/uso terapêutico , Feminino , Fraturas por Compressão/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular , Tíbia/patologia , Fraturas da Tíbia/diagnóstico por imagem
15.
Osteoporos Int ; 16(12): 2005-12, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16078092

RESUMO

Previously, we reported significantly reduced pain and improved mobility persisting for 6 months after kyphoplasty of chronically painful osteoporotic vertebral fractures in the first prospective controlled trial. Since improvement of spinal biomechanics by restoration of vertebral morphology may affect the incidence of fracture, long-term clinical benefit and thereby cost-effectiveness, here we extend our previous work to assess occurrence of new vertebral fractures and clinical parameters 1 year after kyphoplasty compared with a conservatively treated control group. Sixty patients with osteoporotic vertebral fractures due to primary osteoporosis were included: 40 patients were treated with kyphoplasty, 20 served as controls. All patients received standard medical treatment. Morphological characteristics, new vertebral fractures, pain (visual analog scale), physical function [European Vertebral Osteoporosis Study (EVOS) score] (range 0-100 each) and back-pain-related doctors' visits were re-assessed 12 months after kyphoplasty. There were significantly fewer patients with new vertebral fractures of the thoracic and lumbar spine, after 12-months, in the kyphoplasty group than in the control group (P=0.0084). Pain scores improved from 26.2 to 44.4 in the kyphoplasty group and changed from 33.6 to 34.3 in the control group (P=0.008). Kyphoplasty treated patients required a mean of 5.3 back-pain-related doctors' visits per patient compared with 11.6 in the control group during 12 months follow-up (P=0.006). Kyphoplasty as an addition to medical treatment and when performed in appropriately selected patients by an interdisciplinary team persistently improves pain and reduces occurrence of new vertebral fractures and healthcare utilization for at least 12 months in individuals with primary osteoporosis.


Assuntos
Dor nas Costas/prevenção & controle , Osteoporose/cirurgia , Fraturas da Coluna Vertebral/prevenção & controle , Coluna Vertebral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Procedimentos Ortopédicos/métodos , Osteoporose/diagnóstico por imagem , Medição da Dor/métodos , Aceitação pelo Paciente de Cuidados de Saúde , Complicações Pós-Operatórias , Estudos Prospectivos , Radiografia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Resultado do Tratamento
16.
J Bone Miner Res ; 20(4): 604-12, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15765179

RESUMO

UNLABELLED: This study investigates the effects of kyphoplasty on pain and mobility in patients with osteoporosis and painful vertebral fractures compared with conventional medical management. INTRODUCTION: Pharmacological treatment of patients with primary osteoporosis does not prevent pain and impaired activity of patients with painful vertebral fractures. Therefore, we evaluated the clinical outcome after kyphoplasty in patients with vertebral fractures and associated chronic pain for >12 months. MATERIALS AND METHODS: Sixty patients with primary osteoporosis and painful vertebral fractures presenting for >12 months were included in this prospective, nonrandomized controlled study. Twenty-four hours before performing kyphoplasty, the patients self-determined their inclusion into the kyphoplasty or control group so that 40 patients were treated with kyphoplasty, whereas 20 served as controls. This study assessed changes in radiomorphology, pain visual analog scale (VAS) score, daily activities (European Vertebral Osteoporosis Study [EVOS] score), number of new vertebral fractures, and health care use. Outcomes were assessed before treatment and at 3 and 6 months of follow-up. All patients received standard medical treatment (1g calcium, 1000 IE vitamin D(3), standard dose of oral aminobisphosphonate, pain medication, physical therapy). RESULTS: Kyphoplasty increased midline vertebral height of the treated vertebral bodies by 12.1%, whereas in the control group, vertebral height decreased by 8.2% (p = 0.001). Augmentation and internal stabilization by kyphoplasty resulted in a reduction of back pain. VAS pain scores improved in the kyphoplasty group from 26.2 +/- 2 to 44.2 +/- 3.3 (SD; p = 0.007) and in the control group from 33.6 +/- 4.1 to 35.6 +/- 4.1 (not significant), whereas the EVOS score increased in the kyphoplasty group from 43.8 +/- 2.4 to 54.5 +/- 2.7 (p = 0.031) and in the control group from 39.8 +/- 4.5 to 43.8 +/- 4.6 (not significant). The number of back pain-related doctor visits within the 6-month follow-up period decreased significantly after kyphoplasty compared with controls: mean of 3.3 visits/patient in the kyphoplasty group and a mean of 8.6 visits/patient in the control group (p = 0.0147). CONCLUSIONS: The results of this study show significantly increased vertebral height, reduced pain, and improved mobility in patients after kyphoplasty. Kyphoplasty performed in appropriately selected osteoporotic patients with painful vertebral fractures is a promising addition to current medical treatment.


Assuntos
Dor nas Costas/cirurgia , Cifose/cirurgia , Osteoporose/complicações , Fraturas da Coluna Vertebral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor nas Costas/etiologia , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fraturas da Coluna Vertebral/etiologia , Resultado do Tratamento
17.
Clin Orthop Relat Res ; (414): 315-21, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12966306

RESUMO

Low complication rates have been reported when cancellous bone is taken from the proximal tibia. The current study was done to determine the volume of cancellous bone that can be harvested from the proximal tibia and to determine the risk for postoperative tibia plateau fracture. The average compressed volume that could be harvested from nine tibiae was 5.4 cc compared with a reported volume of 6.0 cc from the iliac crest. In eight cadavers, the proximal tibia was decancellated in eight tibias. The decancellated and the matching eight contralateral intact tibias were loaded to determine the force required to cause a tibial plateau fracture. The null hypothesis, that there is no difference between the decancellated and the intact tibias, could not be rejected. The current experimental study supports the clinical findings that a sufficient amount of cancellous bone can be harvested from the proximal tibial metaphysis and that the risk of postoperative fracture is not increased. Therefore, the proximal tibia is a reliable cancellous bone graft donor site for clinical practice.


Assuntos
Transplante Ósseo , Coleta de Tecidos e Órgãos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas da Tíbia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA