Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Circ Heart Fail ; 15(6): e009165, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35670217

RESUMO

BACKGROUND: Current guidelines recommend interpreting concentrations of NPs (natriuretic peptides) irrespective of the time of presentation to the emergency department. We hypothesized that diurnal variations in NP concentration may affect their diagnostic accuracy for acute heart failure. METHODS: In a secondary analysis of a multicenter diagnostic study enrolling patients presenting with acute dyspnea to the emergency department and using central adjudication of the final diagnosis by 2 independent cardiologists, the diagnostic accuracy for acute heart failure of BNP (B-type NP), NT-proBNP (N-terminal pro-B-type NP), and MR-proANP (midregional pro-atrial NP) was compared among 1577 daytime presenters versus 908 evening/nighttime presenters. In a validation study, the presence of a diurnal rhythm in BNP and NT-proBNP concentrations was examined by hourly measurements in 44 stable individuals. RESULTS: Among patients adjudicated to have acute heart failure, BNP, NT-proBNP, and MR-proANP concentrations were comparable among daytime versus evening/nighttime presenters (all P=nonsignificant). Contrastingly, among patients adjudicated to have other causes of dyspnea, evening/nighttime presenters had lower BNP (median, 44 [18-110] versus 74 [27-168] ng/L; P<0.01) and NT-proBNP (median, 212 [72-581] versus 297 [102-902] ng/L; P<0.01) concentrations versus daytime presenters. This resulted in higher diagnostic accuracy as quantified by the area under the curve of BNP and NT-proBNP among evening/nighttime presenters (0.97 [95% CI, 0.95-0.98] and 0.95 [95% CI, 0.93-0.96] versus 0.94 [95% CI, 0.92-0.95] and 0.91 [95% CI, 0.90-0.93]) among daytime presenters (both P<0.01). These differences were not observed for MR-proANP. Diurnal variation of BNP and NT-proBNP with lower evening/nighttime concentration was confirmed in 44 stable individuals (P<0.01). CONCLUSIONS: BNP and NT-proBNP, but not MR-proANP, exhibit a diurnal rhythm that results in even higher diagnostic accuracy among evening/nighttime presenters versus daytime presenters. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT01831115, NCT02091427, and NCT02210897.


Assuntos
Insuficiência Cardíaca , Fator Natriurético Atrial , Biomarcadores , Ritmo Circadiano , Dispneia/complicações , Dispneia/etiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Peptídeo Natriurético Encefálico , Peptídeos Natriuréticos , Fragmentos de Peptídeos , Vasodilatadores
2.
Int J Cardiol ; 270: 14-20, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29891238

RESUMO

BACKGROUND: High-sensitivity cardiac troponin T (hs-cTnT) blood concentrations were shown to exhibit a diurnal rhythm, characterized by gradually decreasing concentrations throughout daytime, rising concentrations during nighttime and peak concentrations in the morning. We aimed to investigate whether this also applies to (h)s-cTnI assays and whether it would affect diagnostic accuracy for acute myocardial infarction (AMI). METHODS: Blood concentrations of cTnI were measured at presentation and after 1 h using four different cTnI assays: three commonly used sensitive (s-cTnI Architect, Ultra and Accu) and one experimental high-sensitivity assay (hs-cTnI Accu) in a prospective multicenter diagnostic study of patients presenting to the emergency department with suspected AMI. These concentrations and their diagnostic accuracy for AMI (quantified by the area under the curve (AUC)) were compared between morning (11 p.m. to 2 p.m.) and evening (2 p.m. to 11 p.m.) presenters. RESULTS: Among 2601 patients, AMI was the final diagnosis in 17.6% of patients. Concentrations of (h)s-cTnI as measured using all four assays were comparable in patients presenting in the morning versus patients presenting in the evening. Diagnostic accuracy for AMI of all four (h)s-cTnI assays were high and comparable between patients presenting in the morning versus presenting in the evening (AUC at presentation: 0.90 vs 0.93 for s-cTnI Architect; 0.91 vs 0.94 for s-cTnI Ultra; 0.89 vs 0.94 for s-cTnI Accu; 0.91 vs 0.94 for hs-cTnI Accu). CONCLUSIONS: Cardiac TnI does not seem to express a diurnal rhythm. Diagnostic accuracy for AMI is very high and does not differ with time of presentation. CLINICAL TRIAL REGISTRATION: NCT00470587, http://clinicaltrials.gov/show/NCT00470587.


Assuntos
Ritmo Circadiano/fisiologia , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico por imagem , Troponina I/sangue , Idoso , Biomarcadores/sangue , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Ned Tijdschr Geneeskd ; 160: D132, 2016.
Artigo em Holandês | MEDLINE | ID: mdl-27677234

RESUMO

When monitoring patients over time, it may be difficult to distinguish 'real changes' from so-called 'natural fluctuations' when interpreting consecutive laboratory results. Consider a patient whose cholesterol level has decreased from a baseline 6.6 mmol/L to 6.1 mmol/L six months after receiving lifestyle advice. How likely is it that this is a 'real change', reflecting a lifestyle change, rather than random fluctuation? Physicians mostly rely on their intuition and clinical experience when interpreting changes in consecutive laboratory results. For inexperienced physicians, the lack of an easy reference for the interpretation of consecutive laboratory results can make decision-making challenging. We have developed the medical/educational smartphone app Labtracker+ that calculates the probability of a 'real change' between two consecutive laboratory results, using biological variation data from scientific literature and analytical precision that is achieved in contemporary laboratories. This approach may complement intuitive, experience-based interpretations of consecutive laboratory results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA