Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Pediatr ; 10: 1031847, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36507131

RESUMO

Background: Endotracheal intubation of very low birth weight infants (VLBWI) is an essential procedure in NICUs, but intubation experience is often limited. Video laryngoscopy (VL) has been described as a tool to improve intubation skills, but studies in high-risk neonatal populations are limited. Objective: The aim of this study was to investigate whether VL is a useful tool to support airway management in high-risk premature infants with inexperienced operators. Methods: In this crossover study predominantly inexperienced participants were exposed in random sequence to VL and conventional direct laryngoscopy (DL) for endotracheal intubation of a VLBWI simulation manikin to measure total time, number of attempts, success rate on first attempt, view of the vocal cords and perceived subjective safety until successful intubation. Results: In our study group of 94 participants there was no significant difference in the total time (mean VL: 34 s (±24 s); DL: 37 s (±28 s), p = 0.246), while the number of intubation attempts using VL was significantly lower (mean VL: 1.22 (±0.53); DL: 1.37 (±0.60), p = 0.023). Success rate of VL during the first attempt was significantly higher (VL: 84%; DL 69%, p = 0.016), view of the vocal cords was significantly better and perceived subjective safety was increased using VL. Conclusions: Our study results suggest that with rather inexperienced operators, VL can be a useful tool to increase rate of successful endotracheal intubation of VLBWI and to improve their perceived safety during the procedure, which may have an impact on mortality and/or morbidity.

2.
ACS Synth Biol ; 11(2): 996-999, 2022 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-35021620

RESUMO

Despite increasing automation, manual pipetting remains a daily important task in life science laboratories. However, the creation of an efficient work plan is often time-consuming, and its completion is error-prone. Here, we present Pipette Show, a free Vue.js based application that optimizes the generation of an efficient work plan for pipetting into microplates and supports its reliable execution by visual guidance. The basis forms a graphical web interface with a module for building workflows as well as a module displaying the information for each pipetting step by illuminating wells of microplates placed on a tablet.


Assuntos
Software , Automação , Fluxo de Trabalho
3.
Phys Rev E ; 102(2-1): 022208, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32942514

RESUMO

We derive methods for estimating the topology of the stationary probability current j[over ⃗]_{s} of the two-species Fokker-Planck equation (FPE) without the need to solve the FPE. These methods are chosen such that they become exact in certain limits, such as infinite system size or vanishing coupling between species in the diffusion matrix. The methods make predictions about the fixed points of j[over ⃗]_{s} and their relation to extrema of the stationary probability distribution and to fixed points of the convective field, which is related to the deterministic drift of the system. Furthermore, they predict the rotation sense of j[over ⃗]_{s} around extrema of the stationary probability distribution. Even though these methods cannot be proven to be valid away from extrema, the boundary lines between regions with different rotation senses are obtained with surprising accuracy. We illustrate and test these methods, using simple reaction systems with only one coupling term between the two species as well as a few generic reaction networks taken from the literature. We use it also to investigate the shape of nonphysical probability currents occurring in reaction systems with detailed balance due to the approximations involved in deriving the Fokker-Planck equation.

4.
J Pediatr ; 223: 51-56.e1, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32482392

RESUMO

OBJECTIVE: To evaluate changes in cerebral oxygenation, peripheral arterial oxygenation, respiratory status, and administered fraction of inspired oxygen during the first 10 minutes of life in premature infants receiving umbilical cord milking compared with delayed cord clamping (DCC). STUDY DESIGN: Premature infants born at 230/7 to 276/7 weeks of gestation were randomized to umbilical cord milking or DCC. A near infrared spectroscopy sensor, pulse oximeter, and electrocardiogram electrodes were placed. Pulse rate, cerebral tissue oxygenation, peripheral oxygen saturation, airway pressure, and fraction of inspired oxygen were collected for 10 minutes in the delivery room. Longitudinal models were used to compare effects of umbilical cord milking and DCC. RESULTS: Fifty-six infants had cerebral oximetry and advanced monitoring at birth. There was an increased incidence of severe intraventricular hemorrhage in infants who received umbilical cord milking compared with DCC (P = .0211). Longitudinal models suggested that peripheral oxygen saturation was higher in the umbilical cord milking group in the first 4 minutes (P = .0221) and that mean airway pressures were lower in the umbilical cord milking group after the first 7 minutes (P = .0072). No statistical differences were observed for fraction of inspired oxygen, cerebral tissue oxygenation, or heart rates. CONCLUSIONS: The data suggest that the rapid transfer of blood during umbilical cord milking may facilitate lung expansion with improved pulmonary blood flow, but may also increase cerebral blood flow, resulting in severe intraventricular hemorrhage. TRIAL REGISTRATION: ClinicalTrials.gov: NCT03145142.


Assuntos
Circulação Cerebrovascular , Parto Obstétrico/métodos , Hemodinâmica/fisiologia , Pulmão/irrigação sanguínea , Cordão Umbilical/irrigação sanguínea , Adulto , Hemorragia Cerebral Intraventricular/etiologia , Parto Obstétrico/efeitos adversos , Feminino , Humanos , Lactente Extremamente Prematuro , Recém-Nascido , Gravidez , Resultado da Gravidez/epidemiologia , Espectroscopia de Luz Próxima ao Infravermelho , Fatores de Tempo
5.
JAMA ; 322(19): 1877-1886, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31742630

RESUMO

Importance: Umbilical cord milking as an alternative to delayed umbilical cord clamping may provide equivalent benefits to preterm infants, but without delaying resuscitation. Objective: To determine whether the rates of death or severe intraventricular hemorrhage differ among preterm infants receiving placental transfusion with umbilical cord milking vs delayed umbilical cord clamping. Design, Setting, and Participants: Noninferiority randomized clinical trial of preterm infants (born at 23-31 weeks' gestation) from 9 university and private medical centers in 4 countries were recruited and enrolled between June 2017 and September 2018. Planned enrollment was 750 per group. However, a safety signal comprising an imbalance in the number of severe intraventricular hemorrhage events by study group was observed at the first interim analysis; enrollment was stopped based on recommendations from the data and safety monitoring board. The planned noninferiority analysis could not be conducted and a post hoc comparison was performed instead. Final date of follow-up was December 2018. Interventions: Participants were randomized to umbilical cord milking (n = 236) or delayed umbilical cord clamping (n = 238). Main Outcomes and Measures: The primary outcome was a composite of death or severe intraventricular hemorrhage to determine noninferiority of umbilical cord milking with a 1% noninferiority margin. Results: Among 540 infants randomized, 474 (88%) were enrolled and completed the trial (mean gestational age of 28 weeks; 46% female). Twelve percent (29/236) of the umbilical cord milking group died or developed severe intraventricular hemorrhage compared with 8% (20/238) of the delayed umbilical cord clamping group (risk difference, 4% [95% CI, -2% to 9%]; P = .16). Although there was no statistically significant difference in death, severe intraventricular hemorrhage was statistically significantly higher in the umbilical cord milking group than in the delayed umbilical cord clamping group (8% [20/236] vs 3% [8/238], respectively; risk difference, 5% [95% CI, 1% to 9%]; P = .02). The test for interaction between gestational age strata and treatment group was significant for severe intraventricular hemorrhage only (P = .003); among infants born at 23 to 27 weeks' gestation, severe intraventricular hemorrhage was statistically significantly higher with umbilical cord milking than with delayed umbilical cord clamping (22% [20/93] vs 6% [5/89], respectively; risk difference, 16% [95% CI, 6% to 26%]; P = .002). Conclusions and Relevance: In this post hoc analysis of a prematurely terminated randomized clinical trial of umbilical cord milking vs delayed umbilical cord clamping among preterm infants born at less than 32 weeks' gestation, there was no statistically significant difference in the rate of a composite outcome of death or severe intraventricular hemorrhage, but there was a statistically significantly higher rate of severe intraventricular hemorrhage in the umbilical cord milking group. The early study termination and resulting post hoc nature of the analyses preclude definitive conclusions. Trial Registration: ClinicalTrials.gov Identifier: NCT03019367.


Assuntos
Hemorragia Cerebral Intraventricular/prevenção & controle , Constrição , Doenças do Prematuro/prevenção & controle , Recém-Nascido Prematuro , Cordão Umbilical , Término Precoce de Ensaios Clínicos , Feminino , Idade Gestacional , Humanos , Lactente , Morte do Lactente , Recém-Nascido , Doenças do Prematuro/mortalidade , Masculino , Avaliação de Resultados em Cuidados de Saúde , Gravidez
6.
Front Pediatr ; 7: 318, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31417887

RESUMO

Background: Newborn piglets are commonly used in biomedical research. However, cardiovascular imaging of this species is quite challenging. For point of care diagnostics of heart function transthoracic echocardiography may be used, which appears to differ comparing newborn piglets with adult pigs. To date, there are few data or studies on the feasibility and quality of measurement of functional echocardiographic parameters in very small neonatal piglets. Objectives: To study the feasibility of transthoracic echocardiography in very small newborn piglets in supine position. Methods: In 44 anesthetized and intubated newborn piglets, positioned in supine position [age 32 h (12-44 h), weight 1,220 g (1,060-1,495 g), median (IQR)] transthoracic echocardiography was performed using a point of care ultrasound device (M-Turbo©, FujiFilm SonoSite BV, Amsterdam, Netherlands), and a standard ultrasound transducer. Results: Using 2D- and M-mode-imaging left- and right-sided heart structures were accessible to transthoracic echocardiography in neonatal piglets. Diameters of the interventricular septum, the left ventricle, and the posterior wall were measured and ejection fraction and shortening fraction was calculated. Both left and right ventricular outflow tract could be imaged, and ventricular filling and systolic function could be evaluated. Furthermore, we were able to assess shunts of fetal circulation, such as patent ductus arteriosus, structure of the heart valves and congenital heart defects including ventricular septal defect. Conclusions: In summary, transthoracic echocardiography is feasible for assessment of cardiovascular function even in very small newborn laboratory piglets in supine position.

7.
PLoS One ; 14(7): e0219211, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31276543

RESUMO

OBJECTIVE: Asphyxia of newborns is a severe and frequent challenge of the peri- and postnatal period. The purpose of this study was to study early morphological, immunological and structural alterations in lung tissue after asphyxia and hemorrhage (AH). METHODS: 44 neonatal piglets (age 32 hrs) underwent asphyxia and hemorrhage (AH) and were treated according to the international liaison committee of resuscitation (ILCOR) guidelines. For this study, 15 piglets (blood transfusion (RBC) n = 9; NaCl n = 6, mean age 31 hrs) were randomly picked. 4 hours after ROSC (return of spontaneous circulation), lung tissue and blood samples were collected. RESULTS: An elevation of myeloperoxidase (MPO) activity was observed 4 hrs after AH accompanied by an increase of surfactant D after RBC treatment. After AH tight junction proteins Claudin 18 and junctional adhesion molecule 1 (JAM1) were down-regulated, whereas Occludin was increased. Furthermore, after AH and RBC treatment dephosphorylated active form of Connexin 43 was increased. CONCLUSIONS: AH in neonatal pigs is associated with early lung injury, inflammation and alterations of tight junctions (Claudin, Occludin, JAM-1) and gap junctions (Connexin 43) in lung tissue, which contributes to the development of lung edema and impaired function.


Assuntos
Asfixia Neonatal/fisiopatologia , Lesão Pulmonar/fisiopatologia , Pulmão/fisiopatologia , Animais , Animais Recém-Nascidos/metabolismo , Asfixia/fisiopatologia , Asfixia Neonatal/metabolismo , Moléculas de Adesão Celular/metabolismo , Claudinas/metabolismo , Conexina 43/metabolismo , Modelos Animais de Doenças , Junções Comunicantes , Lesão Pulmonar/metabolismo , Ocludina/metabolismo , Peroxidase/análise , Proteína D Associada a Surfactante Pulmonar/análise , Choque Hemorrágico/imunologia , Choque Hemorrágico/metabolismo , Suínos , Junções Íntimas/metabolismo
8.
Pediatr Res ; 86(6): 709-718, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31336381

RESUMO

BACKGROUND: Asphyxia of newborns is a severe and frequent challenge of the peri- and postnatal period. METHODS: Forty-four neonatal piglets underwent asphyxia and hemorrhage (AH), followed by resuscitation with blood or crystalloid transfusion. In this study, 15 piglets (blood n = 9, NaCl n = 6, mean age 31 h) were randomly chosen. Four hours after return of spontaneous circulation, heart tissue and blood were collected. Analyses of heart fatty acid binding protein (HFABP), cardiac troponin I (TnI) levels, and activation of the complement system were performed. Histological staining for connexin 43 (Cx43) and complement C5a receptor 1 (C5aR1) was performed. RESULTS: Following AH, systemic elevation of cardiac TnI and HFABP revealed cardiac damage in both groups. Systemic activation of the complement system and the appearance of extracellular histones in plasma of the blood transfusion group were observed. The Cx43 was translocated from the intercalated discs to the cytosol after AH. Cardiac glycogen concentration was reduced in both groups. A significant reduction of C5aR1 in the left ventricle and a significant elevation of the heart injury score were investigated after blood transfusion. CONCLUSION: AH leads to alteration of the heart, particularly in Cx43 and glycogen reserves, as well as local inflammation.


Assuntos
Animais Recém-Nascidos , Asfixia/complicações , Parada Cardíaca/patologia , Hemorragia/complicações , Miocárdio/patologia , Animais , Ecocardiografia , Parada Cardíaca/etiologia , Parada Cardíaca/fisiopatologia , Suínos
9.
Arch Dis Child Fetal Neonatal Ed ; 104(4): F360-F365, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30154236

RESUMO

OBJECTIVE: To assess the efficacy of a newly developed system for closed loop control of the fraction of inspired oxygen (FiO2) on variation of arterial (SpO2) and on regional tissue oxygen saturation (StO2) in preterm infants with fluctuations in SpO2. DESIGN: Randomised crossover trial comparing automated (auto) to manual FiO2 adjustment (manual) during two consecutive 24 hours periods using a Sophie infant ventilator (SPO2C). SETTING: Tertiary university medical centre. PATIENTS: Twelve very low birthweight infant (VLBWI) (gestational age (median; IQR): (25; 23-26 weeks); birth weight (mean±SD): (667±134 g); postnatal age (mean±SD): (31.5±14 days)). MAIN OUTCOME MEASURE: Time within SpO2 target range. RESULTS: There was an increase in time within the intended SpO2 target range (88%-96%) during auto as compared with manual mode (77.8%±7.1% vs 68.5%±7.7% (mean±SD), p<0.001) and a decrease in time below the SpO2 target during the auto period (18.1%±6.4% vs 25.6%±7.6%; p<0.01). There was a dramatic reduction in events with an SpO2 <88% with >180 s duration: (2 (0-10) vs 10 (0-37) events, p<0.001) and the need for manual adjustments. The time the infants spent above the intended arterial oxygen range (4.1%±3.8% vs 5.9%±3.6%), median FiO2, mean SpO2 over time and StO2 in the brain, liver and kidney did not differ significantly between the two periods. CONCLUSIONS: Closed-loop FiO2 using SPO2C significantly increased time of arterial SpO2 within the intended range in VLBWI and decreased the need for manual adjustments when compared with the routine adjustment by staff members. StO2 was not significantly affected by the mode of oxygen control.


Assuntos
Hipóxia Encefálica/terapia , Doenças do Prematuro/terapia , Recém-Nascido de muito Baixo Peso , Oxigenoterapia/instrumentação , Oxigênio/uso terapêutico , Respiração Artificial/métodos , Estudos Cross-Over , Feminino , Humanos , Unidades de Terapia Intensiva Neonatal , Masculino
10.
Neonatology ; 114(4): 341-347, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30130752

RESUMO

BACKGROUND: The so-called Thompson-score (TS) for newborns with hypoxic-ischemic encephalopathy (HIE) was developed before the introduction of controlled hypothermia as clinical routine. Information on the predictive value of TS in newborns undergoing therapeutic hypothermia to estimate long-term outcome is limited. OBJECTIVES: To determine the predictive value of TS to estimate long-term cognitive and neurological outcome in newborns with perinatal asphyxia treated with controlled hypothermia. METHODS: Thirty-six term newborns with HIE undergoing controlled hypothermia were followed using Wechsler Preschool and Primary Scale of intelligence III test and standardized neurological examination. The primary outcome was survival without cognitive impairment, defined as an IQ ≥85. Secondary outcomes were motor outcomes, survival without relevant neurological impairment, death and epilepsy. RESULTS: Follow-up was done in 33 out of 36 (91.6%) infants at 53 ± 12 months (mean ± SD). For all investigated parameters, a statistically significant relationship with peak TS was demonstrated. A one-point increase in peak TS indicated an OR (95% CI) of 1.5 (1.1-2.0, p = 0.006) for death or cognitive impairment, an OR (95% CI) of 2.2 (1.3-3.8, p = 0.004) for death or relevant neurologic impairment, an OR (95% CI) of 2.1 (1.3-3.5, p = 0.005) for death or epilepsy and an OR (95% CI) of 1.5 (1.1-2.1, p = 0.02) for death. Although the TS for newborns with adverse outcome (death or cognitive impairment) compared to normal outcome tended to be higher (13 [4-16] vs. 9 [0-13], d1; 15 [5-19] vs. 9 [1-14], d2; 14 [5-21] vs. 8 [2-15], d3; median [range]), there was a considerable overlap during the first 3 days of life between both groups. CONCLUSIONS: The TS seems to be a prognostic tool for predicting the long-term outcome in asphyxiated term newborns undergoing controlled hypothermia after the third day of life. A higher score appears to be significantly associated with an adverse outcome.


Assuntos
Asfixia Neonatal/diagnóstico , Asfixia Neonatal/terapia , Hipotermia Induzida , Hipóxia-Isquemia Encefálica/diagnóstico , Hipóxia-Isquemia Encefálica/terapia , Asfixia Neonatal/mortalidade , Deficiências do Desenvolvimento/etiologia , Feminino , Humanos , Hipóxia-Isquemia Encefálica/mortalidade , Recém-Nascido , Modelos Logísticos , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
11.
Front Pediatr ; 6: 192, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30042934

RESUMO

Background: Evidence for recommendations on the use of volume expansion during cardiopulmonary resuscitation in newborn infants is limited. Objectives: To develop a newborn piglet model with asphyxia, hemorrhage, and cardiac arrest to test different volume resuscitation on return of spontaneous circulation (ROSC). We hypothesized that immediate red cell transfusion reduces time to ROSC as compared to the use of an isotonic crystalloid fluid. Methods: Forty-four anaesthetized and intubated newborn piglets [age 32 h (12-44 h), weight 1,220 g (1,060-1,495g), Median (IQR)] were exposed to hypoxia and blood loss until asystole occurred. At this point they were randomized into two groups: (1) Crystalloid group: receiving isotonic sodium chloride (n = 22). (2) Early transfusion group: receiving blood transfusion (n = 22). In all other ways the piglets were resuscitated according to ILCOR 2015 guidelines [including respiratory support, chest compressions (CC) and epinephrine use]. One hour after ROSC piglets from the crystalloid group were randomized in two sub-groups: late blood transfusion and infusion of isotonic sodium chloride to investigate the effects of a late transfusion on hemodynamic parameters. Results: All animals achieved ROSC. Comparing the crystalloid to early blood transfusion group blood loss was 30.7 ml/kg (22.3-39.6 ml/kg) vs. 34.6 ml/kg (25.2-44.7 ml/kg), Median (IQR). Eleven subjects did not receive volume expansion as ROSC occurred rapidly. Thirty-three animals received volume expansion (16 vs. 17 in the crystalloid vs. early transfusion group). 14.1% vs. 10.5% of previously extracted blood volume in the crystalloid vs. early transfusion group was infused before ROSC. There was no significant difference in time to ROSC between groups [crystalloid group: 164 s (129-198 s), early transfusion group: 163 s (162-199 s), Median (IQR)] with no difference in epinephrine use. Conclusions: Early blood transfusion compared to crystalloid did not reduce time to ROSC, although our model included only a moderate degree of hemorrhage and ROSC occurred early in 11 subjects before any volume resuscitation occurred.

12.
PLoS One ; 13(4): e0196126, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29689108

RESUMO

We propose a method to obtain phase portraits for stochastic systems. Starting from the Fokker-Planck equation, we separate the dynamics into a convective and a diffusive part. We show that stable and unstable fixed points of the convective field correspond to maxima and minima of the stationary probability distribution if the probability current vanishes at these points. Stochastic phase portraits, which are vector plots of the convective field, therefore indicate the extrema of the stationary distribution and can be used to identify stochastic bifurcations that change the number and stability of these extrema. We show that limit cycles in stochastic phase portraits can indicate ridges of the probability distribution, and we identify a novel type of stochastic bifurcation, where the probability maximum moves to the edge of the system through a gap between the two nullclines of the convective field.


Assuntos
Fenômenos Químicos , Processos Estocásticos , Simulação por Computador , Modelos Químicos , Probabilidade
13.
PLoS One ; 12(4): e0176410, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448638

RESUMO

We investigate the influence of intrinsic noise on stable states of a one-dimensional dynamical system that shows in its deterministic version a saddle-node bifurcation between monostable and bistable behaviour. The system is a modified version of the Schlögl model, which is a chemical reaction system with only one type of molecule. The strength of the intrinsic noise is varied without changing the deterministic description by introducing bursts in the autocatalytic production step. We study the transitions between monostable and bistable behavior in this system by evaluating the number of maxima of the stationary probability distribution. We find that changing the size of bursts can destroy and even induce saddle-node bifurcations. This means that a bursty production of molecules can qualitatively change the dynamics of a chemical reaction system even when the deterministic description remains unchanged.


Assuntos
Modelos Teóricos , Razão Sinal-Ruído , Processos Estocásticos
14.
Neonatology ; 112(1): 40-46, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28253519

RESUMO

BACKGROUND: Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. OBJECTIVE: To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during progressive hypoxia, cardiac arrest, cardiopulmonary resuscitation (CPR), and after return of spontaneous circulation (ROSC). METHODS: Thirty-three newborn piglets were exposed to hypoxia until asystole occurred and then resuscitated until ROSC. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2) with one sensor applied to the wrist of the right forelimb (FL) and another to the thigh of the left hind limb (HL). Arterial functional oxygen saturation (SaO2) was measured at baseline and at predefined intervals during each phase of the experiment. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. RESULTS: Bias values were lower at the baseline measurements (-3.7 ± 2.3% in FL and -4.1 ± 3.4% in HL) as well as after ROSC (1.5 ± 4.2% in FL and 0.2 ± 4.6% in HL) with higher precision and accuracy than during other experiment phases. During hypoxia induction, cardiac arrest, and CPR, there was a marked decrease in precision and accuracy as well as an increase in bias up to 43 ± 26 and 56 ± 27% in FL and HL, respectively, over a range of SaO2 from 13 to 51%. CONCLUSION: Pulse oximetry showed increased bias and decreased accuracy and precision during marked hypoxemia in a model of neonatal hypoxic cardiac arrest.


Assuntos
Reanimação Cardiopulmonar , Membro Anterior/irrigação sanguínea , Parada Cardíaca/terapia , Membro Posterior/irrigação sanguínea , Hipóxia/complicações , Oximetria , Oxigênio/sangue , Animais , Animais Recém-Nascidos , Biomarcadores/sangue , Modelos Animais de Doenças , Parada Cardíaca/sangue , Parada Cardíaca/etiologia , Parada Cardíaca/fisiopatologia , Hipóxia/sangue , Hipóxia/fisiopatologia , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Sus scrofa , Fatores de Tempo
15.
Neonatology ; 111(2): 100-106, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27643857

RESUMO

BACKGROUND: There are few data available on the interaction of inflations, chest compressions (CC), and delivery of tidal volumes in newborn infants undergoing resuscitation in the presence of endotracheal tube (ET) leaks. OBJECTIVES: To determine the effects of different respiratory support strategies along with CC on changes in tidal volume and ET leaks in hypoxic newborn piglets with cardiac arrest. METHODS: Asphyxiated newborn piglets, intubated with weight-adapted uncuffed ET, were randomized into three groups and resuscitated according to ILCOR 2010 guidelines: (1) T-piece resuscitator (TPR) group = peak inspiratory pressure (PIP)/positive end-expiratory pressure (PEEP) 25/5 cm H2O, rate 30/min, inflations interposed between CC (3:1 ratio); (2) self- inflating bag (SIB) group = PIP 25 cm H2O without PEEP, rate 30/min, inflations interposed between CC (3:1 ratio), and (3) ventilator group = PIP/PEEP of 25/5 cm H2O, rate 30/min. CC were applied with a rate of 120/min without synchrony to inflations. RESULTS: We observed a significant increase of leak (average increase 11.4%) when CC was added to respiratory support (p = 0.0001). Expired tidal volume was larger in the SIB group than in the two other modes which both applied PEEP. However, tidal volumes caused by CC only were larger in the two groups with PEEP than in the SIB group (without PEEP). CONCLUSIONS: There is interaction between lung inflations and CC affecting leak and delivery of tidal volume, which may be influenced by the mode/device used for respiratory support. Leak is larger in the presence of PEEP. However, CC cause additional tidal volume which is larger in the presence of PEEP.


Assuntos
Parada Cardíaca/terapia , Hipóxia/terapia , Intubação Intratraqueal/efeitos adversos , Pulmão/fisiopatologia , Respiração com Pressão Positiva/efeitos adversos , Animais , Animais Recém-Nascidos , Reanimação Cardiopulmonar/métodos , Oscilação da Parede Torácica , Feminino , Humanos , Recém-Nascido , Masculino , Distribuição Aleatória , Suínos , Volume de Ventilação Pulmonar
16.
Neonatology ; 109(1): 22-30, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26460587

RESUMO

BACKGROUND: There are no clear evidence-based recommendations on the use of different techniques of respiratory support and chest compressions (CC) during neonatal cardiopulmonary resuscitation (CPR). OBJECTIVES: To determine the effects of different respiratory support strategies along with CC representing clinical practice on the return of spontaneous circulation (ROSC) in hypoxic newborn piglets with cardiac arrest. We hypothesized that use of a T-piece resuscitator (TPR) providing positive end-expiratory pressure (PEEP) reduces time to ROSC as compared to a self-inflating bag (SIB) without PEEP. Furthermore, we explored the effects of a ventilator providing inflations without synchrony to CC. METHODS: Thirty-three newborn piglets were exposed to hypoxia until asystole occurred and randomized into three groups and resuscitated according to ILCOR guidelines: group 1 = TPR [peak inspiratory pressure (PIP)/PEEP of 25/5 cm H2O, rate 30/min], inflations interposed between CC (3:1 ratio); group 2 = SIB (PIP of 25 cm H2O without PEEP, rate 30/min), inflations interposed between CC (3:1 ratio), and group 3 = ventilator (PIP/PEEP of 25/5 cm H2O, rate 30/min), CC were applied with a rate of 120/min without synchrony to inflations. Animals were supported for 120 min after ROSC. Primary outcome was time to ROSC. RESULTS: All animals achieved ROSC. We found no significant difference in time to ROSC between groups [median (IQR); TPR: 150 s (150-210); SIB: 150 s (120-180); ventilator: 180 s (150-345)]. There was no difference in use of epinephrine, in blood gases or hemodynamic parameters during the 120-min observation time after ROSC. CONCLUSIONS: We found no significant effect of different respiratory support strategies during CPR on ROSC.


Assuntos
Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Massagem Cardíaca , Respiração com Pressão Positiva/métodos , Animais , Animais Recém-Nascidos , Gasometria , Modelos Animais de Doenças , Epinefrina/uso terapêutico , Feminino , Hemodinâmica , Hipóxia/fisiopatologia , Insuflação/métodos , Masculino , Distribuição Aleatória , Suínos , Ventiladores Mecânicos
17.
Neonatology ; 108(2): 108-14, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26107742

RESUMO

BACKGROUND: Noninvasive ventilation is increasingly used in very-low-birth-weight infants (VLBWI) to reduce complications that occur with invasive ventilation. However, the physiological effects of synchronization during noninvasive nasal intermittent mandatory ventilation (IMV) have not been tested in VLBWI immediately after extubation. OBJECTIVE: We aimed to study the short-term effects of synchronized nasal IMV (S-NIMV) compared to nonsynchronized nasal IMV (NIMV) on breathing effort as measured by phasic esophageal pressure (Pe) deflection, spontaneous respiratory rate (RR), gas exchange, cerebral tissue oxygen saturation (StO2) and intermittent episodes of bradycardia or hypoxemia in VLBWI recovering from respiratory distress syndrome (RDS). METHODS: Fourteen VLBWI recovering from RDS were studied using a randomized cross-over design during both S-NIMV and NIMV (of 2 h each) immediately after extubation. RESULTS: Phasic Pe deflection, spontaneous RR and transcutaneous PCO2 decreased significantly while transcutaneous PO2 and synchrony rate (defined as peak ventilator pressure delivered within the first half of spontaneous inspiration) increased significantly during S-NIMV compared to during NIMV. There was no difference in blood pressure, average arterial oxygen saturation (SpO2), cerebral StO2, fractional tissue oxygen extraction of the brain and severe bradycardia (defined as time with a heart rate <100 beats/min lasting ≥10 s) and in hypoxemic episodes (SpO2 <80%) between the two modes. CONCLUSION: Synchronization during nasal ventilation immediately after extubation in VLBWI recovering from RDS improved gas exchange and decreased the respiratory effort, and it could therefore be considered to provide a more efficient respiratory support and synchrony.


Assuntos
Extubação , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Ventilação com Pressão Positiva Intermitente/métodos , Troca Gasosa Pulmonar , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Pressão Sanguínea , Bradicardia , Estudos Cross-Over , Feminino , Alemanha , Humanos , Hipóxia , Recém-Nascido , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/complicações
18.
Neonatology ; 108(1): 73-80, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26044192

RESUMO

BACKGROUND: There are no evidence-based recommendations on the use of different techniques of respiratory support and chest compressions (CC) during neonatal cardiopulmonary resuscitation (CPR). OBJECTIVES: We studied the short-term effects of different ventilatory support strategies along with CC representing clinical practice on gas exchange [arterial oxygen saturation (SaO2), arterial partial pressure of oxygen (PaO2) and arterial partial pressure of carbon dioxide (PaCO2)], hemodynamics and cerebral oxygenation. We hypothesized that in newborn piglets with cardiac arrest, use of a T-piece resuscitator (TPR) providing positive end-expiratory pressure (PEEP) improves gas exchange as measured by SaO2 during CPR as compared to using a self-inflating bag (SIB) without PEEP. Furthermore, we explored the effects of a mechanical ventilator without synchrony to CC. METHODS: Thirty newborn piglets with asystole were randomized into three groups and resuscitated for 20 min [fraction of inspired oxygen (FiO2) = 0.21 for 10 min and 1.0 thereafter]. Group 1 received ventilation using a TPR [peak inspiratory pressure (PIP)/PEEP of 20/5 cm H2O, rate 30/min] with inflations interposed between CC (3:1 ratio). Group 2 received ventilation using a SIB (PIP of 20 cm H2O without PEEP, rate 30/min) with inflations interposed between CC (3:1 ratio). Group 3 received ventilation using a mechanical ventilator (PIP/PEEP of 20/5 cm H2O, rate 30/min). CC were applied with a rate of 120/min without synchrony to inflations. RESULTS: We found no significant differences in SaO2 between the three groups. However, there was a trend toward a higher SaO2 [TPR: 28.0% (22.3-40.0); SIB: 23.7% (13.4-52.3); ventilator: 44.1% (39.2-54.3); median (interquartile range)] and a lower PaCO2 [TPR: 95.6 mm Hg (82.1-113.6); SIB: 100.8 mm Hg (83.0-108.0); ventilator: 74.1 mm Hg (68.5-83.1); median (interquartile range)] in the mechanical ventilator group. CONCLUSIONS: We found no significant effect on gas exchange using different respiratory support strategies during CPR.


Assuntos
Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Respiração com Pressão Positiva/métodos , Troca Gasosa Pulmonar , Animais , Animais Recém-Nascidos , Gasometria , Dióxido de Carbono , Feminino , Hemodinâmica , Masculino , Oxigênio , Suínos , Ventiladores Mecânicos
19.
Neonatology ; 107(2): 113-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25471619

RESUMO

BACKGROUND: Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. OBJECTIVE: To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during cardiopulmonary resuscitation (CPR). METHODOLOGY: In a prospective cohort study in 30 healthy newborn piglets, cardiac arrest was induced, and thereafter each piglet received CPR for 20 min. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2). Arterial blood was analyzed for functional oxygenation (SaO2) every 2 min. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. RESULTS: Bias values were decreased at the baseline measurements (mean: 2.5 ± 4.6%) with higher precision and accuracy compared with values across the experiment. Two minutes after cardiac arrest, there was a marked decrease in precision and accuracy as well as an increase in bias up to 13 ± 34%, reaching a maximum of 45.6 ± 28.3% after 10 min over a mean SaO2 range of 29-58%. CONCLUSION: Pulse oximetry showed increased bias and decreased accuracy and precision during CPR in a model of neonatal cardiac arrest. We recommend further studies to clarify the exact mechanisms of these false readings to improve reliability of pulse oximetry during the marked desaturation and hypoperfusion found during CPR.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca/sangue , Oximetria/métodos , Oxigênio/análise , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Monitorização Fisiológica , Estudos Prospectivos , Reprodutibilidade dos Testes , Suínos
20.
J Pediatr ; 166(2): 240-4.e1, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25454938

RESUMO

OBJECTIVE: To assess the effect of automated adjustment of the inspired oxygen fraction (FiO2) on arterial oxygen saturation (SpO2) and cerebral tissue oxygen saturation (SctO2) in very low birth weight infants with frequent fluctuations in oxygenation. STUDY DESIGN: Fifteen infants (median gestational age, 25 weeks [range, 23-28 weeks]; median age, 34 days [range, 19-74 days]) were assigned in random sequence to 24 hours of automated adjustment of FiO2 or manual adjustment of FiO2. Primary outcome measurements were time within the SpO2 target range and the area under the curve above and below a defined SctO2 range. RESULTS: Percentage of time within the SpO2 target range increased during automated FiO2 control (76.3% ± 9.2% vs 69.1% ± 8.2% for manual; P < .01). Prolonged episodes with SpO2 <88% of >60 seconds duration (median, 115 episodes [range, 67-240] vs 54 episodes [range, 7-184]; P < .01) and of >180 seconds duration (median, 13 episodes [range, 6-39] vs 2 episodes [range, 0-5]; P < .01) decreased significantly during the automated period. Percentage of time with SpO2 >96% decreased during automated control (6.6% ± 4.4% vs 10.4% ± 3.3%; P < .02). There was no significant difference in FiO2 exposure. The area (deviation × time) below and above the defined SctO2 threshold did not differ between the 2 periods (median, 59.7%*seconds [range, 17.2%-208.3%] for manual vs 49.0%*seconds [range, 4.3%-193.7%] for automated; P = .36). CONCLUSION: Automated FiO2 control in preterm infants with frequent SpO2 fluctuations significantly increased the time within the SpO2 target range and reduced the incidence of prolonged hypoxemic events compared with manual FiO2 adjustment, but did not significantly affect cerebral tissue oxygenation.


Assuntos
Encéfalo/metabolismo , Oxigênio/administração & dosagem , Oxigênio/metabolismo , Respiração Artificial/métodos , Artérias , Estudos Cross-Over , Humanos , Recém-Nascido , Recém-Nascido Prematuro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA