Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Radiother Oncol ; 187: 109810, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37468069

RESUMO

Irradiation of the vertebrae in prepubertal patients, if non-homogenous, can result in future growth deformities including kyphoscoliosis. Vertebral delineation and dosimetry were assessed for 101 paediatric cases reviewed within QUARTET-affiliated trials. Despite the availability of published consensus guidelines, a high variability in vertebral delineation was observed, with impact on dosimetry.


Assuntos
Radioterapia (Especialidade) , Coluna Vertebral , Criança , Humanos , Previsões , Ensaios Clínicos como Assunto
2.
J Cancer Res Clin Oncol ; 149(12): 10965-10974, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37329461

RESUMO

PURPOSE: According to ASTRO and ESTRO guidelines, external beam Partial Breast Irradiation (PBI) is a valid option for early-stage breast cancer patients. Nevertheless, there is lack of consensus about the best treatment schedule. METHODS: We retrospectively analysed data of female patients treated at our institution from 2013 to 2022 with adjuvant "one-week" partial breast irradiation. Clinical Target Volume (CTV) was an isotropic expansion of 15 mm from the tumour bed (identified as the breast tissue between surgical clips). The treatment schedule was 30 Gy delivered with Volumetric Modulated Arc Therapy in 5 daily fractions. The primary endpoint was Local Control (LC). Disease-Free Survival (DFS), Overall Survival (OS) and safety were secondary endpoints. RESULTS: Three hundred and forty-four patients with a median age of 69 (33-87) years were included in the study. After a median follow-up of 34 (7-105) months, 7 patients (2.0%) developed a local recurrence. Three-year LC, DFS and OS actuarial rates were 97.5% (95% CI 96.2%-98.8%), 95.7% (95% CI 94.2%-97.2%), and 96.9% (95% CI 95.7%-98.1%), respectively. Ten (2.9%) patients experienced grade 2 late toxicities. Five (1.5%) patients reported late cardiac major events. Three (0.9%) late pulmonary toxicities were detected. One hundred and five (30.5%) patients reported fat necrosis. Good or excellent cosmetic evaluation following the Harvard Scale was reported in 252 (96.9%) cases by the physicians, while in 241 (89.2%) cases by the patients. CONCLUSION: "One-week" PBI is effective and safe, and this schedule is a valid option for highly selected early breast cancer patients.


Assuntos
Neoplasias da Mama , Mastectomia Segmentar , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Mama/patologia , Neoplasias da Mama/patologia , Intervalo Livre de Doença , Resultado do Tratamento
3.
Front Endocrinol (Lausanne) ; 14: 1205785, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37361526

RESUMO

We report the case of a paediatric female patient affected by Bannayan-Riley-Ruvalcaba syndrome (BRRS) and congenital hypothyroidism (CH) with homozygous mutation of the TPO gene. She underwent total thyroidectomy at the age of seven years because of the development of a multinodular goiter. BRRS patients present an increased risk of benign and malignant thyroid disease since childhood because of inactivating mutation of PTEN, an onco-suppressor gene. Instead, homozygous mutations in the TPO gene can be associated with severe forms of hypothyroidism with goiter; previous studies have described cases of follicular and papillary thyroid cancer in CH patients with TPO mutation despite a perfectly controlled thyroid function with Levothyroxine therapy. To our knowledge, this is the first case that describes the possible synergic role of coexisting mutation of both TPO and PTEN in the development of multinodular goiter underlining the importance of a tailored surveillance program in these patients, especially during childhood.


Assuntos
Hipotireoidismo Congênito , Bócio , Síndrome do Hamartoma Múltiplo , Neoplasias da Glândula Tireoide , Humanos , Criança , Feminino , Síndrome do Hamartoma Múltiplo/complicações , Síndrome do Hamartoma Múltiplo/genética , Síndrome do Hamartoma Múltiplo/patologia , Hipotireoidismo Congênito/complicações , Hipotireoidismo Congênito/genética , Mutação , Bócio/complicações , Bócio/genética , Bócio/cirurgia , PTEN Fosfo-Hidrolase/genética
4.
PLoS One ; 16(2): e0247748, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33635906

RESUMO

PURPOSE: To study a robust and reproducible procedure to investigate a relation between focal brain radiotherapy (RT) low doses, neurocognitive impairment and late White Matter and Gray Matter alterations, as shown by Diffusion Tensor Imaging (DTI), in children. METHODS AND MATERIALS: Forty-five patients (23 males and 22 females, median age at RT 6.2 years, median age at evaluations 11.1 years) who had received focal RT for brain tumors were recruited for DTI exams and neurocognitive tests. Patients' brains were parceled in 116 regions of interest (ROIs) using an available segmented atlas. After the development of an ad hoc, home-made, multimodal and highly deformable registration framework, we collected mean RT doses and DTI metrics values for each ROI. The pattern of association between cognitive scores or domains and dose or DTI values was assessed in each ROI through both considering and excluding ROIs with mean doses higher than 75% of the prescription. Subsequently, a preliminary threshold value of dose discriminating patients with and without neurocognitive impairment was selected for the most relevant associations. RESULTS: The workflow allowed us to identify 10 ROIs where RT dose and DTI metrics were significantly associated with cognitive tests results (p<0.05). In 5/10 ROIs, RT dose and cognitive tests were associated with p<0.01 and preliminary RT threshold dose values, implying a possible cognitive or neuropsychological damage, were calculated. The analysis of domains showed that the most involved one was the "school-related activities". CONCLUSION: This analysis, despite being conducted on a retrospective cohort of children, shows that the identification of critical brain structures and respective radiation dose thresholds is achievable by combining, with appropriate methodological tools, the large amount of data arising from different sources. This supported the design of a prospective study to gain stronger evidence.


Assuntos
Anormalidades Induzidas por Radiação/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/efeitos da radiação , Substância Branca/diagnóstico por imagem , Substância Branca/efeitos da radiação , Criança , Imagem de Tensor de Difusão/métodos , Feminino , Seguimentos , Humanos , Masculino , Testes de Estado Mental e Demência , Transtornos Neurocognitivos , Estudos Retrospectivos
5.
Front Oncol ; 10: 518110, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33072562

RESUMO

Objective: This study aimed to look into the relationship between intensity-modulated-radiotherapy (IMRT)- or volumetric-modulated-arc-therapy (VMAT)-based dose-volume parameters and 5-year outcome for a consecutive series of non-metastatic nasopharyngeal cancer (NPC) patients (pts) treated in a single institution in a non-endemic area in order to identify potential prognostic factors. Materials and methods: A retrospective analysis of consecutive non-metastatic NPC pts treated curatively with IMRT or VMAT and chemotherapy (CHT) between 2004 and 2014 was conducted. One patient was in stage I (0.7%), and 24 pts (17.5%) were in stage II, 38 pts (27.7%) in stage III, 29 pts (21.2%) in stage IVA, and 45 pts (32.8%) in stage IVB. Five pts (3.6%) received radiotherapy (RT) alone. Of the remaining 132 pts (96.4%), 30 pts (21.9%) received CHT concomitant to RT, and 102 pts (74.4%) were treated with induction CHT followed by RT-CHT. IMRT was given with standard fractionation at a total dose of 70 Gy. Clinical outcomes investigated in the study were local control (LC), disease-free survival (DFS), and overall survival (OS). Kaplan-Meier (KM) analysis was performed for the outcomes considering dose and coverage parameters, staging, and RT technique. Results: Overall, 137 pts were eligible for this retrospective analysis. With a median follow-up of 70 months (range 12-143), actuarial rates at 5 years were LC 90.4, DFS 77.2, and OS 82.8%. For this preliminary study, T stage was dichotomized as T1, T2, T3 vs. T4. At 5 years, the group T1-T2-T3 reported an LC of 93%, a DFS of 79%, and an OS of 88%, whereas T4 pts reported LC, DFS, and OS, respectively, of 56, 50, and 78%. Pts with V95% > 95.5% had better LC (p = 0.006). Pts with D99% > 63.8 Gy had better LC (p = 0.034) and OS (p = 0.005). The threshold value of 43.2 cm3 of GTVT was prognostic for LC (p = 0.016). To predict the risk of local recurrence at 5 years, we constructed a nomogram which combined GTVT with D99% relative to HRPTV. Conclusions: We demonstrated the prognostic value of some dose-volume parameters, although in a retrospective series, this is potentially useful to improve planning procedure. In addition, for the first time in a non-endemic area, a threshold value of GTVT, prognostic for LC, has been confirmed.

6.
Med Biol Eng Comput ; 58(4): 843-855, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32048135

RESUMO

Survival of pediatric patients with brain tumor has increased over the past 20 years, and increasing evidence of iatrogenic toxicities has been reported. In follow-ups, images are acquired at different time points where substantial changes of brain morphology occur, due to childhood physiological development and treatment effects. To address the image registration complexity, we propose two multi-metric approaches (Mplus, Mdot), combining mutual information (MI) and normalized gradient field filter (NGF). The registration performance of the proposed metrics was assessed on a simulated dataset (Brainweb) and compared with those obtained by MI and NGF separately, using mean magnitude and mean angular errors. The most promising metric (Mplus) was then selected and tested on a retrospective dataset comprising 45 pediatric patients who underwent focal radiotherapy for brain cancer. The quality of the realignment was scored by a radiation oncologist using a perceived misalignment metric (PM). All patients but one were assessed as PM ≤ 2 (good alignment), but the remaining one, severely affected by hydrocephalus and pneumocephalus at the first MRI acquisition, scored PM = 5 (unacceptable). These preliminary findings suggest that Mplus might improve the registration accuracy in complex applications such as pediatric oncology, when data are acquired throughout the years of follow-up, and is worth investigating. Graphical abstract Graphical abstract showing the clinical workflow of the overall registration procedure including the three rigid steps, the fourth deformable step, the reference MRI and the registered MRI as well as the contoured ROIs. The registration performance is assessed by means of the Perceived Misalignment score (PM).


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/radioterapia , Criança , Pré-Escolar , Humanos , Estudos Retrospectivos
7.
Med Phys ; 46(6): 2541-2555, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30974485

RESUMO

PURPOSE: To apply Failure Mode and Effects Analysis (FMEA) to optimize linac quality control (QC) protocol in order to ensure patient safety and treatment quality, taking maximum advantage of the available resources. MATERIAL AND METHODS: Each parameter tested by the QC was considered as a potential failure mode (FM). For each FM, likelihood of occurrence (O), severity of effect (S), and lack of detectability (D) were evaluated and corresponding Risk Priority Number (RPN) was calculated from the product of three indexes. The scores were assigned using two methods: (a) A survey submitted to the medical physicists; (b) A semi-quantitative analysis (SQA) performed through: simulation of FMs in the treatment planning system; studies reported in literature; results obtained by the QC data analysis. A weighted RPN for all FMs was calculated taking into account both the methods. For each linac, the tests were then sorted by their frequency and the RPN value. RESULTS: A high variability was found in the scores of the survey, although in many it was reduced in RPN values, highlighting the more relevant tests as on beam output and imaging system. Integrating these results with those obtained by SQA, the RPN-based ranking of tests has been provided considering the specific use of the accelerator: for example, more accurate tests on dose modulation and multileaf collimator speed were required in linacs where intensity-modulated treatment is performed, while, more specific tests on couch and jaw position indicators were necessary where treatments with multiple isocenters and/or junctions between adjacent fields were often delivered. CONCLUSIONS: Failure Mode and Effects Analysis is a useful tool to prioritize the linac QCs, taking into account the specific equipment and clinical practice. The integration of SQA and survey results reduces subjectivity of the FMEA scoring and allows to optimize linac QCs without "losing" the expertise and experience of medical physicists and clinical staff.


Assuntos
Aceleradores de Partículas , Falha de Equipamento , Controle de Qualidade , Risco
8.
Strahlenther Onkol ; 195(9): 843-850, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31025053

RESUMO

PURPOSE: Pediatric radiotherapy (RT) is a highly specialized field, requiring great experience to delineate correctly tumor targets and organs at risk. To reduce treatment failures related to planning inaccuracies and to obtain robust clinical results despite the limited numbers of enrolled pediatric patients, the SIOP PNET5MB clinical trial on medulloblastoma requires a real-time, pre-radiation review of the RT treatment (craniospinal irradiation and boost plan) under the direct responsibility of the national coordinator center. Here we describe the centralized radiotherapy quality assurance (QA) program developed in Italy for this purpose. METHODS: Using the software package VODCA (MSS, Hagendorn, Switzerland, www.vodca.ch ), we developed a cloud platform able to handle computed tomography (CT) images and RT objects and to support the complete workflow required by the review process in the context of the SIOP PNET5 trial. RESULTS: All Italian centers participating in the PNET5 trial adopted the proposed QA system. 24 patients were successfully enrolled and reviewed. For 15 patients (62.5%), one or more plan revisions were requested for the craniospinal irradiation plan and for 11 patients (45.8%) plan revisions were requested for the boost. RT was delivered after the plan was centrally approved for all enrolled patients. So far, in Italy, no patients have been excluded from PNET5 due to dosimetric incompliance to the protocol or for exceeding the RT starting time limit. CONCLUSION: The cloud platform successfully supported the trial workflow, producing official review documents. This efficient QA was crucial to guarantee optimized treatments and protocol compliance for all pediatric patients enrolled in the SIOP protocol.


Assuntos
Neoplasias Cerebelares/radioterapia , Computação em Nuvem , Meduloblastoma/radioterapia , Tumores Neuroectodérmicos Primitivos/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Especialização , Criança , Humanos , Órgãos em Risco/efeitos da radiação , Radiometria , Planejamento da Radioterapia Assistida por Computador/métodos , Design de Software , Fluxo de Trabalho
9.
Acta Oncol ; 57(9): 1240-1249, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29698060

RESUMO

PURPOSE: Conventional techniques (3D-CRT) for craniospinal irradiation (CSI) are still widely used. Modern techniques (IMRT, VMAT, TomoTherapy®, proton pencil beam scanning [PBS]) are applied in a limited number of centers. For a 14-year-old patient, we aimed to compare dose distributions of five CSI techniques applied across Europe and generated according to the participating institute protocols, therefore representing daily practice. MATERIAL AND METHODS: A multicenter (n = 15) dosimetric analysis of five different techniques for CSI (3D-CRT, IMRT, VMAT, TomoTherapy®, PBS; 3 centers per technique) was performed using the same patient data, set of delineations and dose prescription (36.0/1.8 Gy). Different treatment plans were optimized based on the same planning target volume margin. All participating institutes returned their best treatment plan applicable in clinic. RESULTS: The modern radiotherapy techniques investigated resulted in superior conformity/homogeneity-indices (CI/HI), particularly in the spinal part of the target (CI: 3D-CRT:0.3 vs. modern:0.6; HI: 3D-CRT:0.2 vs. modern:0.1), and demonstrated a decreased dose to the thyroid, heart, esophagus and pancreas. Dose reductions of >10.0 Gy were observed with PBS compared to modern photon techniques for parotid glands, thyroid and pancreas. Following this technique, a wide range in dosimetry among centers using the same technique was observed (e.g., thyroid mean dose: VMAT: 5.6-24.6 Gy; PBS: 0.3-10.1 Gy). CONCLUSIONS: The investigated modern radiotherapy techniques demonstrate superior dosimetric results compared to 3D-CRT. The lowest mean dose for organs at risk is obtained with proton therapy. However, for a large number of organs ranges in mean doses were wide and overlapping between techniques making it difficult to recommend one radiotherapy technique over another.


Assuntos
Radiação Cranioespinal/métodos , Padrões de Prática Médica/estatística & dados numéricos , Radioterapia (Especialidade) , Adolescente , Comitês Consultivos/organização & administração , Radiação Cranioespinal/estatística & dados numéricos , Europa (Continente)/epidemiologia , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Radioterapia (Especialidade)/métodos , Radioterapia (Especialidade)/organização & administração , Radiometria/métodos , Radiometria/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas
10.
Acad Radiol ; 24(7): 795-801, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28189505

RESUMO

RATIONALE AND OBJECTIVES: This study evaluates the influence of the calibrated luminance level of medical displays in the detectability of microcalcifications and spiculated lesions in digital breast tomosynthesis images. MATERIALS AND METHODS: Four models of medical displays with calibrated maximum and minimum luminance, respectively, ranging from 500 to 1000 cd/m2 and from 0.5 to 1.0 cd/m2, were investigated. Forty-eight studies were selected by a senior radiologist: 16 with microcalcifications, 16 with spiculated lesions, and 16 without lesions. All images were anonymized and blindly evaluated by one senior and two junior radiologists. For each study, lesion presence or absence and localization statements, interpretative difficulty level, and overall quality were reported. Cohen's kappa statistic was computed between monitors and within or between radiologists to estimate the reproducibility in correctly identifying lesions; for multireader-multicase analysis, the weighted jackknife alternative free-response receiver operating characteristic statistical tool was applied. RESULTS: Intraradiologist reproducibility ranged from 0.75 to 1.00. Interreader as well as reader-truth agreement values were >0.80 and higher with the two 1000 cd/m2 luminance displays than with the lower luminance displays for each radiologist. Performances in the detectability of breast lesions were significantly greater with the 1000 cd/m2 luminance displays when compared to the display with the lowest luminance value (P value <0.001). CONCLUSIONS: Our findings highlight the role of display luminance level on the accuracy of detecting breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Apresentação de Dados , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Neoplasias da Mama/patologia , Calcinose/patologia , Feminino , Humanos , Curva ROC , Reprodutibilidade dos Testes
11.
Sex Dev ; 10(1): 28-36, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27070133

RESUMO

Clinical records (n = 24) with an established diagnosis of 5α-reductase-2 deficiency were reviewed. A previous misdiagnosis was present in about 70% (period from first observation to definitive diagnosis: 9.1 ± 10.8 years), and in 8 children gonadal removal was performed before certain diagnosis. Initial sex assignment was female in 16/24 (67%) and male in 8/24 (33%) cases. After diagnosis, sex re-assignment was performed in 5 babies (4 girls to male sex; 1 boy to female sex). Baseline testosterone/DHT ratio was diagnostic in 6/12 subjects (first months of life n = 4; puberty n = 2), while post-hCG testosterone/DHT ratio was diagnostic in all tested individuals (choosing both the cut-off value 15 or 10). Eighteen different mutations in the steroid-5α-reductase-2 (SRD5A2) gene were identified, 5 of which have never been reported. In conclusion, a time lag exists before the diagnosis of 5α-reductase-2 deficiency is established; sex assignment and gonadal removal may be performed before certain diagnosis. Sex re-assignment is usually female to male, but the contrary may occur. A large variability in clinical phenotypes and genetic mutations was present in this cohort. Accurate endocrine evaluation is recommended in babies possibly affected by 5α-reductase-2 deficiency, since the use of appropriate cut-off values of testosterone/DHT ratio after hCG stimulation may permit to select individuals for SRD5A2 gene analysis. A genotype-phenotype correlation was not found in this study.


Assuntos
3-Oxo-5-alfa-Esteroide 4-Desidrogenase/deficiência , 3-Oxo-5-alfa-Esteroide 4-Desidrogenase/genética , Adolescente , Adulto , Criança , Pré-Escolar , Di-Hidrotestosterona/sangue , Transtornos do Desenvolvimento Sexual/sangue , Transtornos do Desenvolvimento Sexual/enzimologia , Transtornos do Desenvolvimento Sexual/genética , Feminino , Estudos de Associação Genética , Humanos , Lactente , Itália , Masculino , Pessoa de Meia-Idade , Mutação , Testosterona/sangue , Adulto Jovem
12.
Tumori ; 102(4): 409-13, 2016 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-27002946

RESUMO

PURPOSE: To evaluate the dosimetric coverage of axillary levels I, II, and III obtained with standard whole breast irradiation in 1 to 2 positive sentinel lymph nodes (SLNs) patients not submitted to axillary lymph nodes dissection (ALND), and to compare the lymph nodes areas coverage obtained with 3D conformal radiation therapy, intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). METHODS: Patients with 1 to 2 positive SLNs undergoing breast-conserving therapy, without ALND, were included in the analysis. For each patient, 3 treatment plans were performed: a 3D conventional tangential plan, a static IMRT plan, and a volumetric IMRT, designed to encompass the entire breast parenchyma. The volumes of axillary levels I, II, and III receiving 90% and 95% (V90, V95) of the whole breast prescribed dose were evaluated. Dose-volume histograms were compared by means of the Friedman test. RESULTS: Ten patients were enrolled. All defined breast volumes received >95% of the prescribed dose with the 3 techniques. Median V95 for axillary level I was 26.4% (range 4.7%-61.3%) for 3D plans, 8.6% (range 0.64%-19.1%) for static IMRT plans, and 2.6% (range 0.4%-4.7%) for volumetric IMRT plans (p<0.001). Median V95 for axillary level II was 5.4% (range 0%-14.6%), 1.9% (range 0%-15%), and 2.6% (range 0.4%-4.7%) for 3D, static IMRT, and volumetric IMRT, respectively (p<0.001). CONCLUSIONS: Results of our analysis showed that standard 3D tangential whole breast irradiation failed to deliver a therapeutic dose to axillary levels I and II. The coverage was even lower using static and volumetric IMRT techniques.


Assuntos
Axila , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Linfonodo Sentinela/patologia , Relação Dose-Resposta à Radiação , Feminino , Humanos , Metástase Linfática , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
13.
J Radiol Prot ; 36(1): 144-62, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26909554

RESUMO

The evaluation of incoherent artificial optical radiation (AOR) exposure in hospital environments is a complex task due to the variety of sources available. This study has been designed to provide a proposal for the precautionary assessment of the related risk. This survey suggested that, in our Institution, at least three kinds of AOR sources required specific investigations: ambient lighting, theatre operating lighting and ultraviolet radiation (UVR) sources. For each kind of evaluated sources a specific measurement approach was developed. All irradiance measurements were made using a commercial spectroradiometer. The obtained results were compared with the appropriate exposure limit values (ELVs) defined in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines and adopted by the European Directive 2006/25/EC. The risk related to the evaluated AOR exposure was finally assessed according to our risk matrix. According to our results, the emission of ambient lighting in the actual exposure conditions was always in accordance with the ELVs and the related risk was classifiable as not relevant. The risk related to the exposure to theatre operating lighting resulted not negligible, especially when two or more sources were used with focal spots overlapping on reflective objects. UVR sources emission may represent a health hazard depending, in particular, on the set up of the device containing the source. In case of laminar flow cabinets and closed transilluminators, if the UVR source is well contained within an enclosure with interlock, it presents no risk of exposure. Otherwise, the emission arising from UVR lamps, open transilluminators or sources not provided with interlock, may represent a risk classifiable as high even in the actual working conditions. The personal protective equipment used by workers were also assessed and their suitability was discussed.


Assuntos
Exposição Ocupacional/efeitos adversos , Fenômenos Ópticos , Proteção Radiológica , Radiação não Ionizante/efeitos adversos , Europa (Continente) , Hospitais , Humanos , Raios Infravermelhos , Fatores de Risco , Raios Ultravioleta
14.
J Pediatr Adolesc Gynecol ; 25(3): e77-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22578489

RESUMO

BACKGROUND: The growing use of prenatal investigations allows an early detection of several inborn disorders, including disorders of sexual development. The management of these conditions is an arising problem. CASE: 46,XY karyotype and female phenotype were detected in a fetus; 5α-reductase and androgen receptor gene analysis on chorionic villi revealed no relevant mutation. The newborn was assigned to female sex. The diagnosis of 17ß-hydroxysteroid dehydrogenase-3 ß-OL deficiency was reached at four months of age, by means of a low testosterone/Δ 4-androstenedione ratio after HCG test and HSD17B3 gene analysis. SUMMARY AND CONCLUSION: A 46,XY fetus with female external genitalia suggests different conditions, some very rare. Specific genetic investigations should be performed prenatally when possible. A complete evaluation is mandatory after delivery to reach a correct diagnosis.


Assuntos
17-Hidroxiesteroide Desidrogenases/deficiência , Transtorno 46,XY do Desenvolvimento Sexual/diagnóstico , Diagnóstico Pré-Natal , Transtorno 46,XY do Desenvolvimento Sexual/enzimologia , Feminino , Humanos , Lactente , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA