Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Med ; 13(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38892756

RESUMO

State-of-the-art therapy improves the five-year survival rate of patients under the age of 20 with cranial and craniospinal tumors by up to 74%. The urgency of dealing effectively with late treatment-associated cardiovascular complications is rising. Objective: We aimed to assess echocardiographic parameters and exercise performance in subjects with a history of complex treatment for cranial and craniospinal tumors in childhood. Methods: the study of 48 subjects who underwent cranial and craniospinal irradiation for CNS tumors in childhood and 20 healthy age- and sex-matched volunteers was conducted. The examination included hormone studies, cardiopulmonary exercise testing, and, in the main group, echocardiography (ECHO). Results: In five (10.4%) patients, ECHO changes were detected after complex anti-cancer treatment: thickening and calcification of the aortic valve leaflets (2%), and reduction in the systolic LV and RV function (8% and 6%, respectively). Irradiation of various areas was a significant predictor for reduced exercise tolerance, hyperventilation at rest and upon exertion, and an increased ventilatory equivalent for carbon dioxide. Low exercise tolerance was associated with a younger age at the time of treatment initiation. Significant differences were noted between the control group and the childhood cancer survivors with endocrine disorders. Conclusions: The obtained data confirm the importance of regular cardiovascular and endocrine monitoring of this group of cancer survivors.

2.
Int J Cardiol Heart Vasc ; 50: 101336, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304727

RESUMO

Background: Anti-cancer treatment can be fraught with cardiovascular complications, which is the most common cause of death among oncological survivors. Without appropriate cardiomonitoring during anti-cancer treatment, it becomes challenging to detect early signs of cardiovascular complications. In order to achieve higher survival rates, it is necessary to monitor oncological patients outpatiently after anti-cancer treatment administration. In this regard, we aim to evaluate the efficacy of single-lead ECG remote monitoring to detect cardiotoxicity in cancer patients with minimal cardiovascular diseases after the first cycle of polychemotherapy. Materials and methods: The study included patients 162 patients over 18 years old with first diagnosed different types of solid tumors, planed for adjuvant (within 8 weeks after surgery) or neoadjuvant polychemotherapy. All patients were monitored, outpatiently, during 14-21 days (depending on the regimen of polychemotherapy) after polychemotherapy administration using single-lead ECG. Results: QTc > 500 mc prolongation was detected in 8 patients (6.6 %), first-diagnosed arial fibrillation was detected in 11 patients (9 %) in period after chemotherapy administration. Moreover, left ventricular diastolic dysfunction using single-lead ECG after polychemotherapy was detected in 49 (40.1 %) patients with sensitivity 80 %, specificity 95 %, AUC 0.88 (95 % CI, 0.82-0.93). Conclusions: The side effects of cancer treatment may cause life-threatening risks. Early identification of cardiotoxicity plays a vital role in the solution of this problem. Using portable devices to detect early cardiotoxicity is a simple, convenient and affordable screening method, that can be used for promptly observation of patients.

3.
Pathophysiology ; 30(4): 586-598, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38133143

RESUMO

It would be useful to develop a reliable method for the cuffless measurement of blood pressure (BP), as such a method could be made available anytime and anywhere for the effective screening and monitoring of arterial hypertension. The purpose of this study is to evaluate blood pressure measurements through a CardioQVARK device in clinical practice in different patient groups. METHODS: This study involved 167 patients aged 31 to 88 years (mean 64.2 ± 7.8 years) with normal blood pressure, high blood pressure, and compensated high blood pressure. During each session, three routine blood pressure measurements with intervals of 30 s were taken using a sphygmomanometer with an appropriate cuff size, and the mean value was selected for comparison. The measurements were carried out by two observers trained at the same time with a reference sphygmomanometer using a Y-shaped connector. In the minute following the last cuff-based measurements, an electrocardiogram (ECG) with an I-lead and a photoplethysmocardiogram were recorded simultaneously for 3 min with the CardioQVARK device. We compared the systolic and diastolic BP obtained from a cuff-based mercury sphygmomanometer and smartphone-case-based BP device: the CardioQVARK monitor. A statistical analysis plan was developed using the IEEE Standard for Wearable Cuffless Blood Pressure Devices. Bland-Altman plots were used to estimate the precision of cuffless measurements. RESULTS: The mean difference between the values defined by CardioQVARK and the cuff-based sphygmomanometer for systolic blood pressure (SBP) was 0.31 ± 3.61, while that for diastolic blood pressure (DBP) was 0.44 ± 3.76. The mean absolute difference (MAD) for SBP was 3.44 ± 2.5 mm Hg, and that for DBP was 3.21 ± 2.82 mm Hg. In the subgroups, the smallest error (less than 3 mm Hg) was observed in the prehypertension group, with a slightly larger error (up to 4 mm Hg) found among patients with a normal blood pressure and stage 1 hypertension. The largest error was found in the stage 2 hypertension group (4-5.5 mm Hg). The largest error was 4.2 mm Hg in the high blood pressure group. We, therefore, did not record an error in excess of 7 mmHg, the upper boundary considered acceptable in the IEEE recommendations. We also did not reach a mean error of 5 mmHg, the upper boundary considered acceptable according to the very recent ESH recommendations. At the same time, in all groups of patients, the systolic blood pressure was determined with an error of less than 5 mm Hg in more than 80% of patients. While this study shows that the CardioQVARK device meets the standards of IEEE, the Bland-Altman analysis indicates that the cuffless measurement of diastolic blood pressure has significant bias. The difference was very small and unlikely to be of clinical relevance for the individual patient, but it may well have epidemiological relevance on a population level. Therefore, the CardioQVARK device, while being worthwhile for monitoring patients over time, may not be suitable for screening purposes. Cuffless blood pressure measurement devices are emerging as a convenient and tolerable alternative to cuff-based devices. However, there are several limitations to cuffless blood pressure measurement devices that should be considered. For instance, this study showed a high proportion of measurements with a measurement error of <5 mmHg, while detecting a small, although statistically significant, bias in the measurement of diastolic blood pressure. This suggests that this device may not be suitable for screening purposes. However, its value for monitoring BP over time is confirmed. Furthermore, and most importantly, the easy measurement method and the device portability (integrated in a smartphone) may increase the self-awareness of hypertensive patients and, potentially, lead to an improved adherence to their treatment. CONCLUSION: The cuffless blood pressure technology developed in this study was tested in accordance with the IEEE protocol and showed great precision in patient groups with different blood pressure ranges. This approach, therefore, has the potential to be applied in clinical practice.

4.
Open Heart ; 9(1)2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35609943

RESUMO

OBJECTIVE: To determine the impact of sodium-dependent glucose type 2 cotransporter inhibitors on the renal function in acute heart failure. METHODS: In a single-centre, controlled, randomised study, patients were prescribed dapagliflozin in addition to standard therapy, or were in receipt of standard therapy. The prespecified outcome was renal function deterioration; the secondary outcomes were the development of resistance to diuretics, weight loss, death during hospitalisation and the rehospitalisation or death for any reason within 30 days following discharge. RESULTS: 102 patients were included (73.4±11.7 years, 57.8% men). The average left ventricular ejection fraction was 44.9%±14.7%, the average N-terminal prohormone of brain natriuretic peptide (NT-proBNP) was 4706 (1757; 11 244) pg/mL, the average estimated glomerular filtration rate (eGFR) was 51.6±19.5 mL/min. eGFR decreased 48 hours after randomisation in the dapagliflozin group (-4.2 (-11.03; 2.28) mL/min vs 0.3 (-6; 6) mL/min; p=0.04) but did not differ between the groups on discharge (54.71±19.18 mL/min and 58.92±24.65 mL/min; p=0.36). The incidence of worsening renal function did not differ (34.4% vs 15.2%; p=0.07). In the dapagliflozin group, there was less tendency to increase the dose of loop diuretics (14% vs 30%; p=0.048), lower average doses of loop diuretics (78.46±38.95 mg/day vs 102.82±31.26 mg/day; p=0.001) and more significant weight loss (4100 (2950; 5750) g vs 3000 (1380; 4650) g; p=0.02). In-hospital mortality was 7.8% (4(8%) in the dapagliflozin and 4 (7.7%) in the control group (p=0.95). The number of deaths within 30 days following discharge in the dapagliflozin group and in the control group was 9 (19%) and 12 (25%), p=0.55; the number of rehospitalisations was 14 (29%) and 17 (35%), respectively (p=0.51). CONCLUSION: The use of dapagliflozin was associated with a more pronounced weight loss and less need to increase diuretic therapy without significant deterioration of the renal function. Dapagliflozin did not improve the in-hospital and 30-day prognosis after discharge. TRIAL REGISTRATION NUMBER: N04778787.


Assuntos
Insuficiência Cardíaca , Inibidores de Simportadores de Cloreto de Sódio e Potássio , Compostos Benzidrílicos , Diuréticos/efeitos adversos , Feminino , Glucosídeos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Rim/fisiologia , Masculino , Projetos Piloto , Inibidores de Simportadores de Cloreto de Sódio e Potássio/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Redução de Peso
5.
Glob Heart ; 17(1): 4, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35174045

RESUMO

Background: Screening for atrial fibrillation has the potential to significantly reduce cardiovascular morbidity and mortality. However, questions in regard to how to screen, on whom to screen, and the optimal setting of screening remain unanswered. Objective: To assess the applicability of a federal cardiac monitoring for atrial fibrillation (AF) screening and remote heart rhythm monitoring in patients at high cardiovascular risk in a mixed urban and rural population in Russia. Methods: This is a prospective multicenter cohort study including 3249 individuals with high cardiovascular risk (mean age 56 ± 12.8 years) from the larger Moscow region who were screened for AF using a smartphone-case based single-lead ECG monitor over a period of 18 month. The endpoints were considered as number of newly diagnosed AF; mean time to diagnosis; number of patients for the first time assigned to anticoagulation therapy; frequency of adverse events. Results: A trial fibrillation was diagnosed in 126 patients, 36 of them for the first time. The mean time to diagnosis was 3 ± 2 days. Of 36 patients, the CHA2DS2-VASc score was ≥1 in 34 cases, ≥2 in 29 cases. Anticoagulant therapy was first induced in 31 patients. One death in newly diagnosed group and two deaths in chronic group were registered. There were a total of eight hospitalizations: one in newly diagnosed and seven in chronic AF patients. Conclusion: Our results indicate that a Federal AF screening system in patients at high cardiovascular risk by using a smartphone-case based single lead ECG which is supported by centrally located ECG specialist and central data management is feasible and reliable when performed in a mixed urban and rural area. Further studies are needed to evaluate the full potential of this approach.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Estudos de Coortes , Eletrocardiografia , Humanos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Atenção Primária à Saúde , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/prevenção & controle
6.
Artigo em Inglês | MEDLINE | ID: mdl-30039765

RESUMO

Atherothrombosis-related diseases are one of the world's leading causes of mortality, and thus the search for new therapeutic approaches in this area remains a very urgent task. Modern pharmacogenomic technologies make it possible to obtain valuable data on disease pathogenesis and optimal therapeutic approaches. One promising research direction is the study of the thromboxane A2 - thromboxane A synthase - thromboxane A2 receptor axis. This review summarizes the recent evidence and suggests that systematic works in this area are creating new and promising opportunities in the treatment of patients with cardiovascular diseases.


Assuntos
Doenças Cardiovasculares/tratamento farmacológico , Doenças Cardiovasculares/metabolismo , Inibidores Enzimáticos/uso terapêutico , Terapia de Alvo Molecular , Tromboxano-A Sintase/antagonistas & inibidores , Tromboxano-A Sintase/metabolismo , Animais , Doenças Cardiovasculares/genética , Doenças Cardiovasculares/patologia , Descoberta de Drogas/métodos , Inibidores Enzimáticos/farmacologia , Humanos , Terapia de Alvo Molecular/métodos , Testes Farmacogenômicos , Agregação Plaquetária/efeitos dos fármacos , Polimorfismo Genético , Receptores de Tromboxano A2 e Prostaglandina H2/metabolismo , Transdução de Sinais/efeitos dos fármacos , Tromboxano A2/metabolismo , Tromboxano-A Sintase/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA