Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Pediatr Radiol ; 54(1): 49-57, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37999795

RESUMO

BACKGROUND: Upper respiratory tract infections usually peak during winter months. OBJECTIVE: The purpose of this study was to evaluate whether imaging of complicated upper airway infection in children increased during the winter season of 2022/2023. MATERIALS AND METHODS: In a retrospective study setting, pediatric magnetic resonance imaging (MRI) and computed tomography (CT) scans for evaluation of upper respiratory tract infection performed between October 2022 and April 2023 were analyzed regarding presence of the following complications: mastoiditis, abscess, phlegmon, meningitis, reactive vasculitis, and sinus vein thrombosis. Pathogen detection, surgery, and infection parameters were obtained. Data were compared with MRI and CT scans performed in the same months of the preceding five years, distinguishing between pandemic and pre-pandemic years. RESULTS: During the 2022/2023 winter season, the number of MRI and CT scans in children with upper airway infections, the complication rate, the rate of detected streptococcal infections, and the rate of surgery increased significantly compared to expectations based on the five prior winter seasons (all P<0.05). During the first complete pandemic winter season in Europe (2020/2021), the number of MRI and CT scans in children with upper airway infection, the complication rate, and the rates of streptococcal detection and surgery decreased significantly compared to expectations based on the pre-pandemic, the second pandemic, and the post-pandemic winter seasons (all P<0.05). CONCLUSION: After a decline during the first pandemic winter season, there was a marked rebound in complicated upper airway infection in children, with a significant increase in cases during the 2022/2023 winter season compared to the pre-pandemic and pandemic years.


Assuntos
COVID-19 , Infecções Respiratórias , Criança , Humanos , Lactente , Estações do Ano , Estudos Retrospectivos , Infecções Respiratórias/diagnóstico por imagem , Europa (Continente)
2.
Radiology ; 308(1): e230084, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37404154

RESUMO

Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = -0.61, P = .01) but poor during follow-up (r = -0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.


Assuntos
Fibrose Cística , Humanos , Fibrose Cística/diagnóstico por imagem , Fibrose Cística/tratamento farmacológico , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Estudos Prospectivos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mutação
3.
Acad Radiol ; 30(9): 1773-1783, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36764882

RESUMO

RATIONALE AND OBJECTIVES: In breast MRI with diffusion-weighted imaging (DWI), fat suppression is essential for eliminating the dominant lipid signal. This investigation evaluates a combined water-excitation-spectral-fatsat method (WEXfs) versus standard spectral attenuated inversion recovery (SPAIR) in high-resolution 3-Tesla breast MRI. MATERIALS AND METHODS: Multiparametric breast MRI with 2 echo-planar DWI sequences was performed in 83 patients (50.1 ± 12.6 years) employing either WEXfs or SPAIR for fat signal suppression. Three radiologists assessed overall DWI quality and delineability of 88 focal lesions (28 malignant, 60 benign) on images with b values of 800 and 1600 s/mm2, as well as apparent diffusion coefficient (ADC) maps. For each fat suppression method and b value, the longest lesion diameter was determined in addition to measuring the signal intensity in DWI and ADC value in standardized regions of interest. RESULTS: Regardless of b values, image quality (all p < 0.001) and lesion delineability (all p ≤ 0.003) with WEXfs-DWI were deemed superior compared to SPAIR-DWI in benign and malignant lesions. Irrespective of lesion characterization, WEXfs-DWI provided superior signal-to-noise, contrast-to-noise and signal-intensity ratios with 1600 s/mm2 (all p ≤ 0.05). The lesion size difference between contrast-enhanced T1 subtraction images and DWI was smaller for WEXfs compared to SPAIR fat suppression (all p ≤ 0.007). The mean ADC value in malignant lesions was lower for WEXfs-DWI (p < 0.001), while no significant ADC difference was ascertained between both techniques in benign lesions (p = 0.947). CONCLUSION: WEXfs-DWI provides better subjective and objective image quality than standard SPAIR-DWI, resulting in a more accurate estimation of benign and malignant lesion size.


Assuntos
Neoplasias Encefálicas , Neoplasias da Mama , Feminino , Humanos , Neoplasias Encefálicas/patologia , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar , Adulto , Pessoa de Meia-Idade
4.
Acta Radiol ; 64(5): 1851-1858, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36718493

RESUMO

BACKGROUND: Ultrashort-echo-time (UTE) sequences have been developed to overcome technical limitations of pulmonary magnetic resonance imaging (MRI). Recently, it has been shown that UTE sequences with breath-hold allow rapid image acquisition with sufficient image quality. However, patients with impaired respiration require alternative acquisition strategies while breathing freely. PURPOSE: To compare the diagnostic performance of free-breathing three-dimensional (3D)-UTE sequences with different trajectories based on pulmonary imaging of immunocompromised patients. MATERIAL AND METHODS: In a prospective study setting, two 3D-UTE sequences performed in free-breathing and exploiting non-Cartesian trajectories-one using a stack-of-spirals and the other exploiting a radial trajectory-were acquired at 3 T in patients undergoing hematopoietic stem cell transplantation. Two radiologists assessed the images regarding presence of pleural effusions and pulmonary infiltrations. Computed tomography (CT) was used as reference. RESULTS: A total of 28 datasets, each consisting of free-breathing 3D-UTE MRI with the two sequence techniques and a reference CT scan, were acquired in 20 patients. Interrater agreement was substantial for pulmonary infiltrations using both sequence techniques (κ = 0.77 - 0.78). Regarding pleural effusions, agreement was almost perfect in the stack-of-spirals (κ = 0.81) and moderate in the radial sequence (κ = 0.59). No significant differences in detectability of the assessed pulmonary pathologies were observed between both 3D-UTE sequence techniques (P > 0.05), and their level of agreement was substantial throughout (κ = 0.62-0.81). Both techniques provided high sensitivities and specificities (79%-100%) for the detection of pulmonary infiltrations and pleural effusions compared to reference CT. CONCLUSION: The diagnostic performance of the assessed 3D-UTE MRI sequences was similar. Both sequences enable the detection of typical inflammatory lung pathologies.


Assuntos
Imageamento Tridimensional , Derrame Pleural , Humanos , Estudos Prospectivos , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Respiração , Imageamento por Ressonância Magnética/métodos
5.
Eur J Radiol ; 155: 110493, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36027759

RESUMO

PURPOSE: We tested a novel multi-parametric (mp) whole body (WB)-MRI evaluation algorithm for medullary lesions in comparison to positron emission tomography (PET) radiotracers 18F-fluorodeoxyglucose (18F-FDG) and 11C-methionine (11C-MET). METHODS AND MATERIALS: This retrospective single-center study included 44 MM patients, who received both 18F-FDG-PET and WB-MRI within ten days. MRI classified focal lesions as vital when showing 1) significant diffusion-restriction, 2) a fat fraction (FF) less than 20 % and 3) homogenous hypointensity on T2-weighted images. On a lesion-by-lesion level the findings were compared to 18F-FDG PET by using a 5-point scoring system (analogous to the Deauville score [DS]). In 24/44 (55 %) patients additional comparison to 11C-MET PET was available. RESULTS: Among two radiologists, an excellent inter-observer reliability for mpWB-MRI in a total of 84 medullary lesions was observed (ICC = 1, k = 1, p <.01). 16/17 (94.1 %) MRI-classified vital lesions had a DS of 4 or 5 on either 18F-FDG-PET or 11C-MET-PET. MRI-rated non-vital lesions correlated with PET-based DS ≤ 3. When results of mpWB-MRI were compared to 18F-FDG, a fair inter-observer agreement was recorded (ICC = 0.52, k = 0.53, p <.01), while for 11C-MET, an excellent concordance rate was achieved (ICC = 0.81, k = 0.79, p <.01). CONCLUSION: The proposed mpWB-MRI interpretation algorithm allowed to assess tumor activity of myeloma lesions with high inter-observer reproducibility. We observed a substantial concordance between the mpWB-MRI classification of lesions and PET assessment based on a semi-automatically calculated 5-point scoring system analogous to the Deauville scores.


Assuntos
Fluordesoxiglucose F18 , Mieloma Múltiplo , Humanos , Imageamento por Ressonância Magnética/métodos , Metionina , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Racemetionina , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Br J Haematol ; 198(3): 515-522, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35582835

RESUMO

Measurement of minimal residual disease (MRD) by next-generation flow cytometry (NGF) is an important tool to define deep responses in multiple myeloma (MM). However, little is known about the value of combining NGF with functional imaging and its role for MRD-based consolidation strategies in clinical routine. In the present study, we report our experience investigating these issues with 102 patients with newly diagnosed (n = 57) and relapsed/refractory MM (n = 45). Imaging was performed using either positron emission tomography or diffusion-weighted magnetic resonance imaging. In all, 45% of patients achieved MRD-negativity on both NGF and imaging (double-negativity), and 8% and 40% of patients were negative on either NGF or imaging respectively. Thus, in a minority of patients imaging was the only technique to detect residual disease. Imaging-positivity despite negativity on NGF was more common in heavily pretreated disease (four or more previous lines) compared to newly diagnosed MM (p < 0.01). Among the 29 patients undergoing MRD-triggered consolidation, 51% responded with MRD conversion and 21% with improved serological response. MRD-triggered consolidation led to superior progression-free survival (PFS) when compared to standard treatment (p = 0.04). In conclusion, we show that combining NGF with imaging is helpful particularly in patients with heavily pretreated MM, and that MRD-based consolidation could lead to improved PFS.


Assuntos
Citometria de Fluxo , Mieloma Múltiplo , Citometria de Fluxo/métodos , Humanos , Imageamento por Ressonância Magnética , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/tratamento farmacológico , Neoplasia Residual/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Resultado do Tratamento
7.
Eur Radiol ; 32(8): 5045-5052, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35298677

RESUMO

OBJECTIVE: Multipartite epicondyles may mimic fractures in the setting of pediatric elbow trauma. This study examines the prevalence of multipartite epicondyles during skeletal development and their association with pediatric elbow fractures. MATERIALS AND METHODS: In this retrospective analysis, 4282 elbow radiographs of 1265 elbows of 1210 patients aged 0-17 years were reviewed. The radiographs were analyzed by two radiologists in consensus reading, and the number of visible portions of the medial and lateral epicondyles was noted. For elbows in which epicondylar ossification was not yet visible, the epicondyles were already fused with the humerus or could not be sufficiently evaluated due to projection issues or because osteosynthesis material was excluded. In total, 187 elbows were included for the lateral and 715 for the medial epicondyle analyses. RESULTS: No multipartite medial epicondyles were found in patients without history of elbow fracture, whereas 9% of these patients had multipartite lateral epicondyles (p < 0.01). Current or previous elbow fractures increased the prevalence of multipartite epicondyles, with significant lateral predominance (medial epicondyle + 9% vs. lateral + 24%, p < 0.0001). Including all patients regardless of a history of elbow fracture, multipartite medial epicondyles were observed in 3% and multipartite lateral epicondyles in 18% (p < 0.0001). There was no gender difference in the prevalence of multipartition of either epicondyle, regardless of a trauma history. CONCLUSION: Multipartite medial epicondyles occur in patients with current or previous elbow fractures only, whereas multipartite lateral epicondyles may be constitutional. Elbow fractures increase the prevalence of multipartite epicondyles on both sides, with significant lateral predominance. KEY POINTS: • Multipartite medial epicondyles should be considered of traumatic origin. • Multipartite lateral epicondyles may be constitutional. • Elbow fractures increase the prevalence of multipartite epicondyles on both sides with lateral predominance.


Assuntos
Articulação do Cotovelo , Fraturas do Úmero , Criança , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Fixação Interna de Fraturas , Humanos , Fraturas do Úmero/complicações , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/epidemiologia , Úmero , Estudos Retrospectivos
8.
Acad Radiol ; 29(1): e1-e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33139155

RESUMO

RATIONALE AND OBJECTIVES: Our study compared sensitivity, specificity, and accuracy of whole-body diffusion-weighted imaging (WB-DWI) using a b-value of 2000 s/mm2 with that of the commonly used b-value of 800 s/mm2 for depiction of active tumor sites in patients with plasma cell diseases. We introduced an ultrahigh b-value to reduce interfering signals from benign and post-therapeutic inactive lesions by suppressing T2-shine-through effects. MATERIALS AND METHODS: The prospective single-center study included patients when they went through a whole-body MRI (WB-MRI) staging or response evaluation procedure. The apparent diffusion coefficient (ADC) and morphologic appearance served as reference for classifying focal lesions on WB-DWI as vital or post-therapeutic. Additionally, we compared our classification with patients' serological markers of disease activity. RESULTS: One hundred participants (65 ± 10 years, 58 men) underwent WB-DWI between June and October 2019. The detection rate of vital focal lesions was similar for both b-values with a sensitivity of 0.99 using b = 800 s/mm2 and 0.98 using b = 2000 s/mm2. By contrast, specificity and accuracy were 0.09 and 0.71 when using a b-value of 800 s/mm2, and 0.96 and 0.98 when using a b-value of 2000 s/mm2, respectively. The difference in specificity and accuracy was statistically significant (p < 0.001). CONCLUSION: Using a b-value of 2000 s/mm2 significantly improved the specificity of lesion detection with WB-DWI as compared to the commonly used b-value of 800 s/mm2. The high b-value significantly reduced signal intensities of post-therapeutic or benign lesions and provided a significantly more accurate representation of active tumor load.


Assuntos
Paraproteinemias , Imagem Corporal Total , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade
9.
Rofo ; 194(1): 39-48, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34649285

RESUMO

PURPOSE: To evaluate the feasibility of non-contrast-enhanced three-dimensional ultrashort echo time (3D-UTE) MRI for pulmonary imaging in immunocompromised patients during hematopoietic stem cell transplantation (HSCT). METHODS: MRI was performed using a stack-of-spirals 3D-UTE sequence (slice thickness: 2.34mm; matrix: 256 × 256; acquisition time: 12.7-17.6 seconds) enabling imaging of the entire thorax within single breath-holds. Patients underwent MRI before HSCT initiation, in the case of periprocedural pneumonia, before discharge, and in the case of re-hospitalization. Two readers separately assessed the images regarding presence of pleural effusions, ground glass opacities (GGO), and consolidations on a per lung basis. A T2-weighted (T2w) multi-shot Turbo Spin Echo sequence (BLADE) was acquired in coronal orientation during breath-hold (slice thickness: 6.00mm; matrix: 320 × 320; acquisition time: 3.1-5.5 min) and read on a per lesion basis. Low-dose CT scans in inspiration were used as reference and were read on a per lung basis. Only scans performed within a maximum of three days were included in the inter-method analyses. Interrater agreement, sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of 3D-UTE MRI were calculated. RESULTS: 67 MRI scans of 28 patients were acquired. A reference CT examination was available for 33 scans of 23 patients. 3D-UTE MRI showed high sensitivity and specificity regarding pleural effusions (n = 6; sensitivity, 92 %; specificity, 100 %) and consolidations (n = 22; sensitivity 98 %, specificity, 86 %). Diagnostic performance was lower for GGO (n = 9; sensitivity, 63 %; specificity, 84 %). Accuracy rates were high (pleural effusions, 98 %; GGO, 79 %; consolidations 94 %). Interrater agreement was substantial for consolidations and pleural effusions (κ = 0.69-0.82) and moderate for GGO (κ = 0.54). Compared to T2w imaging, 3D-UTE MRI depicted the assessed pathologies with at least equivalent quality and was rated superior regarding consolidations and GGO in ~50 %. CONCLUSION: Non-contrast 3D-UTE MRI enables radiation-free assessment of typical pulmonary complications during HSCT procedure within a single breath-hold. Yet, CT was found to be superior regarding the identification of pure GGO changes. KEY POINTS: · 3D-UTE MRI of the thorax can be acquired within a single breath-hold.. · 3D-UTE MRI provides diagnostic imaging of pulmonary consolidations and pleural effusions.. · 3D-UTE sequences improve detection rates of ground glass opacities on pulmonary MRI.. · 3D-UTE MRI depicts pulmonary pathologies at least equivalent to T2-weighted Blade sequence.. CITATION FORMAT: · Metz C, Böckle D, Heidenreich JF et al. Pulmonary Imaging of Immunocompromised Patients during Hematopoietic Stem Cell Transplantation using Non-Contrast-Enhanced Three-Dimensional Ultrashort Echo Time (3D-UTE) MRI. Fortschr Röntgenstr 2022; 194: 39 - 48.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Imageamento Tridimensional , Humanos , Hospedeiro Imunocomprometido , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética
10.
BMC Med Imaging ; 21(1): 79, 2021 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-33964892

RESUMO

BACKGROUND: Functional lung MRI techniques are usually associated with time-consuming post-processing, where manual lung segmentation represents the most cumbersome part. The aim of this study was to investigate whether deep learning-based segmentation of lung images which were scanned by a fast UTE sequence exploiting the stack-of-spirals trajectory can provide sufficiently good accuracy for the calculation of functional parameters. METHODS: In this study, lung images were acquired in 20 patients suffering from cystic fibrosis (CF) and 33 healthy volunteers, by a fast UTE sequence with a stack-of-spirals trajectory and a minimum echo-time of 0.05 ms. A convolutional neural network was then trained for semantic lung segmentation using 17,713 2D coronal slices, each paired with a label obtained from manual segmentation. Subsequently, the network was applied to 4920 independent 2D test images and results were compared to a manual segmentation using the Sørensen-Dice similarity coefficient (DSC) and the Hausdorff distance (HD). Obtained lung volumes and fractional ventilation values calculated from both segmentations were compared using Pearson's correlation coefficient and Bland Altman analysis. To investigate generalizability to patients outside the CF collective, in particular to those exhibiting larger consolidations inside the lung, the network was additionally applied to UTE images from four patients with pneumonia and one with lung cancer. RESULTS: The overall DSC for lung tissue was 0.967 ± 0.076 (mean ± standard deviation) and HD was 4.1 ± 4.4 mm. Lung volumes derived from manual and deep learning based segmentations as well as values for fractional ventilation exhibited a high overall correlation (Pearson's correlation coefficent = 0.99 and 1.00). For the additional cohort with unseen pathologies / consolidations, mean DSC was 0.930 ± 0.083, HD = 12.9 ± 16.2 mm and the mean difference in lung volume was 0.032 ± 0.048 L. CONCLUSIONS: Deep learning-based image segmentation in stack-of-spirals based lung MRI allows for accurate estimation of lung volumes and fractional ventilation values and promises to replace the time-consuming step of manual image segmentation in the future.


Assuntos
Fibrose Cística/diagnóstico por imagem , Aprendizado Profundo , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos de Casos e Controles , Fibrose Cística/fisiopatologia , Humanos , Pulmão/fisiologia , Neoplasias Pulmonares/diagnóstico por imagem , Redes Neurais de Computação , Pneumonia/diagnóstico por imagem , Respiração
12.
J Thorac Imaging ; 36(1): 43-51, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32453280

RESUMO

PURPOSE: Ultrashort echotime (UTE) sequences aim to improve the signal yield in pulmonary magnetic resonance imaging (MRI). We demonstrate the initial results of spiral 3-dimensional (3D) UTE-MRI for combined morphologic and functional imaging in pediatric patients. METHODS: Seven pediatric patients with pulmonary abnormalities were included in this observational, prospective, single-center study, with the patients having the following conditions: cystic fibrosis (CF) with middle lobe atelectasis, CF with allergic bronchopulmonary aspergillosis, primary ciliary dyskinesia, air trapping, congenital lobar overinflation, congenital pulmonary airway malformation, and pulmonary hamartoma.Patients were scanned during breath-hold in 5 breathing states on a 3-Tesla system using a prototypical 3D stack-of-spirals UTE sequence. Ventilation maps and signal intensity maps were calculated. Morphologic images, ventilation-weighted maps, and signal intensity maps of the lungs of each patient were assessed intraindividually and compared with reference examinations. RESULTS: With a scan time of ∼15 seconds per breathing state, 3D UTE-MRI allowed for sufficient imaging of both "plus" pathologies (atelectasis, inflammatory consolidation, and pulmonary hamartoma) and "minus" pathologies (congenital lobar overinflation, congenital pulmonary airway malformation, and air trapping). Color-coded maps of normalized signal intensity and ventilation increased diagnostic confidence, particularly with regard to "minus" pathologies. UTE-MRI detected new atelectasis in an asymptomatic CF patient, allowing for rapid and successful therapy initiation, and it was able to reproduce atelectasis and hamartoma known from multidetector computed tomography and to monitor a patient with allergic bronchopulmonary aspergillosis. CONCLUSION: 3D UTE-MRI using a stack-of-spirals trajectory enables combined morphologic and functional imaging of the lungs within ~115 second acquisition time and might be suitable for monitoring a wide spectrum of pulmonary diseases.


Assuntos
Imageamento Tridimensional , Neoplasias Pulmonares , Criança , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos
14.
Radiology ; 296(1): 191-199, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32343212

RESUMO

Background In cystic fibrosis (CF), recurrent imaging and pulmonary function tests (PFTs) are needed for the assessment of lung function during disease management. Purpose To assess the clinical feasibility of pulmonary three-dimensional ultrashort echo time (UTE) MRI at breath holding for quantitative image analysis of ventilation inhomogeneity and hyperinflation in CF compared with PFT. Materials and Methods In this prospective study from May 2018 to June 2019, participants with CF and healthy control participants underwent PFTs and functional lung MRI by using a prototypical single breath-hold three-dimensional UTE sequence. Fractional ventilation (FV) was calculated from acquired data in normal inspiration and normal expiration. FV of each voxel was normalized to the whole lung mean (FVN), and interquartile range of normalized ventilation (IQRN; as a measure of ventilation heterogeneity) was calculated. UTE signal intensity (SI) was assessed in full expiration (SIN, normalized to aortic blood). Obtained metrics were compared between participants with CF and control participants. For participants with CF, MRI metrics were correlated with the standard lung clearance index (LCI) and PFT. Mann-Whitney U tests and Spearman correlation were used for statistical analysis. Results Twenty participants with CF (mean age, 17 years ± 9 [standard deviation]; 12 men) and 10 healthy control participants (24 years ± 8; five men) were included. IQRN was higher for participants with CF than for control participants (mean, 0.66 ± 0.16 vs 0.50 ± 0.04, respectively; P = .007). In the 20 participants with CF, IQRN correlated with obstruction markers forced expiratory volume in 1 second-to-forced vital capacity ratio (r = -0.70; 95% confidence interval [CI]: -0.92, -0.28; P < .001), mean expiratory flow 25% (r = 0.78; 95% CI: -0.95, -0.39; P < .001), and with the ventilation inhomogeneity parameter LCI (r = 0.90; 95% CI: 0.69, 0.96; P < .001). Mean SIN in full expiration was lower in participants with CF than in control participants (0.34 ± 0.08 vs 0.39 ± 0.03, respectively; P = .03). Conclusion Three-dimensional ultrashort echo time MRI in the lungs allowed for functional imaging of ventilation inhomogeneity within a few breath holds in patients with cystic fibrosis. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Assuntos
Fibrose Cística/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Estudos de Viabilidade , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Estudos Prospectivos
15.
Int J Cardiol ; 312: 129-135, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32201099

RESUMO

AIMS: Impaired myocardial sympathetic innervation assessed by 123Iodine-Metaiodobenzylguanidine (123I-MIBG) scintigraphy is associated with cardiac events. Since regional disparities of structural abnormalities are common in inherited arrhythmia syndromes (iAS), a chamber-specific innervation assessment of the right (RV) and left ventricle (LV) could provide important insights for a patient-individual therapy. Aim of this study was to evaluate chamber-specific patterns of autonomic innervation by Single-photon emission computed tomography/computed tomography (SPECT/CT) in patients with iAS with respect to clinical outcome regarding cardiac events. METHODS AND RESULTS: We assessed ventricular sympathetic innervation (LV, RV and planar heart/mediastinum-ratios, and washout-rates) by 123I-MIBG-SPECT/CT in 48 patients (arrhythmogenic right ventricular cardiomyopathy [ARVC], n = 26; laminopathy, n = 8; idiopathic ventricular fibrillation [iVF], n = 14) in relation to a composite clinical endpoint (ventricular arrhythmia; cardiac death; cardiac hospitalization). RV tracer uptake was lower in patients with ARVC than in laminopathy and iVF patients (1.7 ± 0.4 vs. 2.1 ± 0.7 and 2.1 ± 0.5, respectively). Over a median follow-up of 2.2 years, the combined endpoint was met in 18 patients (n = 12 ventricular tachyarrhythmias, n = 5 hospitalizations, n = 1 death). LV, but not RV H/M ratio was associated with the combined endpoint (hazard-ratio 2.82 [1.30-6.10], p < 0.01). After adjustment for LV and RV function, LV H/M-ratio still remained a significant predictor for cardiac events (hazard-ratio 2.79 [1.06-7.35], p = 0.04). CONCLUSION: We demonstrated that chamber-specific 123MIBG-SPECT/CT imaging is feasible and that reduced LV sympathetic innervation was associated with worse outcome in iAS. These findings provide novel insights into the potential role of regional autonomic nervous system heterogeneity for the evolution of life-threatening cardiac events in iAS.


Assuntos
Ventrículos do Coração , Sistema Nervoso Simpático , 3-Iodobenzilguanidina , Arritmias Cardíacas/diagnóstico por imagem , Coração , Humanos , Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Síndrome , Tomografia Computadorizada de Emissão de Fóton Único
16.
Radiol Cardiothorac Imaging ; 2(3): e190162, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33778581

RESUMO

PURPOSE: To evaluate three-dimensional (3D) ultrashort echo time (UTE) MRI regarding image quality and suitability for functional image analysis using gradient-echo sequences in breath-hold and with self-navigation. MATERIALS AND METHODS: In this prospective exploratory study, 10 patients (mean age, 21 years; age range, 5-58 years; five men) and 10 healthy control participants (mean age, 25 years; age range, 10-39 years; five men) underwent 3D UTE MRI at 3.0 T. Imaging was performed with a prototypical stack-of-spirals 3D UTE sequence during single breath holds (echo time [TE], 0.05 msec) and with a self-navigated "Koosh ball" 3D UTE sequence at free breathing (TE, 0.03 msec). Image quality was rated on a four-point Likert scale. Edge sharpness was calculated. After semiautomated segmentation, fractional ventilation was calculated from MRI signal intensity (FVSI) and volume change (FVVol). The air volume fraction (AVF) was estimated from relative signal intensity (aortic blood signal intensity was used as a reference). Means were compared between techniques and participants. The Wilcoxon signed rank test and Spearman rank correlation were used for statistical analyses. RESULTS: Image quality ratings were equal for both techniques. However, stack-of-spirals breath-hold UTE was more susceptible to motion and aliasing artifacts. Mean FVSI was higher during breath hold than at free breathing (mean ± standard deviation in milliliters of gas per milliliters of parenchyma, 0.17 mL/mL ± 0.06 [minimum, 0.07; maximum, 0.34] vs 0.11 mL/mL ± 0.03 [minimum, 0.06; maximum, 0.17], P = .016). Mean FVSI and FVVol were in good agreement (mean difference: at breath hold, -0.008 [95% confidence interval {CI}: 0.007, -0.024]; ρ = 0.97 vs free breathing, -0.004 [95% CI: 0.007, -0.016]; ρ = 0.91). AVF correlated between both techniques (ρ = 0.94). CONCLUSION: Breath-hold and self-navigated 3D UTE sequences yield proton density-weighted images of the lungs that are similar in quality, and both techniques are suitable for functional image analysis.Supplemental material is available for this article.© RSNA, 2020.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA