Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Neth Heart J ; 30(10): 466-472, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35380415

RESUMO

INTRODUCTION: Although anticoagulation therapy is mandated after implantation of a left ventricular assist device (LVAD), postoperative bleedings and reoperations occur relatively frequently and are associated with worse outcomes. We evaluated the use of a conservative postoperative anticoagulation protocol in patients implanted with a HeartMate 3 (HM3) LVAD. METHODS: In a single-centre retrospective analysis of postoperative outcomes after HM3 LVAD implantation, a standard (old) anticoagulation protocol (i.e. early, full-dose anticoagulation with low-molecular weight heparin and overlapping vitamin K antagonist) was compared with a new conservative anticoagulation protocol (i.e. slow initiation of vitamin K antagonists without overlapping heparin). Main outcomes were changes in international normalised ratio (INR), lactate dehydrogenase (LDH), bleeding and/or tamponade events requiring reoperation, length of stay and adverse events. RESULTS: In total, 73 patients (48 in old vs 25 in new protocol group) were evaluated. Mean age was 56 years (standard deviation 13) and most patients (78%) were males. Changes in INR and LDH in the first 14 days were similar in both groups (p = 0.50 and p = 0.997 for interaction, respectively). Number of bleeding/tamponade events requiring reoperation was lower in the new than in the old protocol group (4% vs 33%, p = 0.005). Postoperative 30-day mortality was similar, and we observed no thromboembolic events. Median (25th-75th percentiles) total length of postoperative hospital stay (27 (25-41) vs 21 (19-27) days, p < 0.001) and length of intensive care unit stay (5 (2-9) vs 2 (2-5) days, p = 0.022) were significantly shorter in the new protocol group. CONCLUSION: These retrospective data suggest that conservative slow initiation of anticoagulation therapy after HM3 LVAD implantation is associated with less bleeding/tamponade events requiring reoperation, a similar safety profile and a shorter duration of stay than the currently advised standard anticoagulation protocol.

3.
Int J Cardiovasc Imaging ; 22(6): 771-4, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16779614

RESUMO

We present a case of a 66-year-old patient with infective endocarditis of an aortic valve bioprosthesis with major dehiscence and extensive "rocking motion" but without any diastolic paravalvular regurgitation as assessed with radiography and transesophageal echocardiography.


Assuntos
Valva Aórtica/diagnóstico por imagem , Bioprótese , Ecocardiografia Transesofagiana , Endocardite/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Idoso , Valva Aórtica/fisiopatologia , Endocardite/etiologia , Endocardite/fisiopatologia , Humanos , Masculino , Infecções Relacionadas à Prótese/fisiopatologia , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA