Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Rheum Dis ; 83(8): 1060-1071, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38531611

RESUMO

OBJECTIVES: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system. METHODS: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis. RESULTS: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes). CONCLUSIONS: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.


Assuntos
Artrite Psoriásica , Articulações dos Dedos , Índice de Gravidade de Doença , Ultrassonografia , Humanos , Artrite Psoriásica/diagnóstico por imagem , Reprodutibilidade dos Testes , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/patologia , Ultrassonografia/métodos , Masculino , Feminino , Técnica Delphi , Sinovite/diagnóstico por imagem , Sinovite/patologia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Entesopatia/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , Cadáver , Estudos de Viabilidade , Adulto , Idoso , Dedos/diagnóstico por imagem , Dedos/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA