Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 65(5): 13, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38713484

RESUMO

Purpose: The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses. Methods: Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures. Results: The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg. Conclusions: In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.


Assuntos
Cadáver , Gonioscopia , Pressão Intraocular , Iris , Terapia a Laser , Trabeculectomia , Humanos , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Iris/cirurgia , Trabeculectomia/métodos , Tonometria Ocular , Idoso , Iridectomia/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais
2.
Lasers Surg Med ; 56(4): 382-391, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38570914

RESUMO

BACKGROUND AND OBJECTIVES: Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open-angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. MATERIALS AND METHODS: An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 µm wide by 200 µm high) in human cadaver eyes using pulse energies of 10, 15, and 20 µJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. RESULTS: Pulse energies of 15 and 20 µJ had a 100% success rate in creating full-thickness FLT channels as imaged by OCT. A pulse energy of 10 µJ resulted in no channels (n = 6), a partial-thickness channel (n = 2), and a full-thickness FLT channel (n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 µJ groups (p < 0.0001), as well as between the 10 and 20 µJ groups (p < 0.0001). However, there was no statistically significant difference between the 15 and 20 µJ groups (p = 0.416). CONCLUSIONS: Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Lasers , Cadáver
3.
Ophthalmol Sci ; 3(4): 100313, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37363134

RESUMO

Purpose: Pilot study to evaluate adverse events and intraocular pressure (IOP)-lowering of a novel, noninvasive glaucoma procedure, femtosecond laser, image-guided, high-precision trabeculotomy (FLIGHT). Design: Prospective, nonrandomized, single-center, interventional, single-arm clinical trial. Participants: Eighteen eyes from 12 patients with open-angle glaucoma. Methods: Eighteen eyes from 12 patients underwent FLIGHT, creating a single channel measuring 500-µm wide by 200-µm high through the trabecular meshwork and into Schlemm's canal. Adverse events, IOP, and other parameters were evaluated out to 24 months. Main Outcome Measures: Outcomes were the rates and types of adverse events and the rate of postprocedure best-corrected visual acuity loss (≥ 2 lines) compared with baseline. Efficacy outcomes were reduction in mean intraocular pressure (IOP) with respect to baseline and the percentage of eyes with a ≥ 20% reduction in IOP. Results: Eighteen eyes from 12 patients were enrolled in the study; 11 patients (17 eyes) returned at 24 months. There were no serious adverse events related to the laser treatment. Well-defined channels were clearly visible at 24 months by gonioscopy and anterior segment OCT, with no evidence of closure. At 24 months, the mean IOP was reduced by 34.6% from 22.3 ± 5.5 to 14.5 ± 2.6 mmHg (P < 5e-5), with an average of 2.0 ± 1.2 hypotensive medications compared with 2.2 ± 1.1 at baseline (P = 0.22). Fourteen out of the 17 study eyes (82.3%) achieved a ≥ 20% reduction in IOP at 24 months when compared with baseline. Conclusion: The FLIGHT system demonstrated a favorable safety profile in this initial pilot study, with no device-related serious adverse events. The channels appeared patent at 24 months, indicating medium-term durability. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

4.
Transl Vis Sci Technol ; 11(3): 28, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-35333286

RESUMO

Purpose: The purpose of this study was to investigate femtosecond laser trabeculotomy (FLT) in a clinically relevant manner (i.e., delivering the surgical laser beam through the cornea of the intact, human anterior segment to create channels from the anterior chamber into the Schlemm's canal) and to investigate the effect of this treatment on intraocular pressure in perfused human anterior segments. Methods: Perfused human anterior segments (15 eyes) received either FLT treatment (n = 8) or a sham-treatment (n = 7). Intraocular pressure (IOP) in the perfused samples was recorded before and after treatment. Spectral domain optical coherence tomography, second harmonic generation imaging, and transmission electron microscopy were used to investigate the FLT channels. Results: The FLT group (n = 7, 1 eye excluded) had a statistically significant reduction in mean IOP of 20.2% from baseline after treatment (5.06 ± 1.46 mm Hg to 4.04 ± 1.63 mm Hg; P < 0.0005), whereas the control group (n = 7) remained statistically unchanged (7.72 ± 3.45 mm Hg to 7.78 ± 3.51 mm Hg; P < 0.71). Imaging confirmed that the channels traversed the entire trabecular meshwork into the Schlemm's canal. Conclusions: This study has provided the first direct evidence supporting the feasibility of clinically applicable, noninvasive femtosecond laser trabeculotomy for the treatment of glaucoma. Various imaging modalities revealed minimal collateral damage to adjacent issues. Translational Relevance: This work demonstrates noninvasive femtosecond laser trabeculotomy in a laboratory setting that is clinically relevant.


Assuntos
Glaucoma , Trabeculectomia , Cadáver , Humanos , Lasers , Malha Trabecular/cirurgia , Trabeculectomia/métodos
6.
Transl Vis Sci Technol ; 10(9): 22, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34406341

RESUMO

Purpose: This study investigated the initial feasibility of using femtosecond laser trabeculotomy (FLT) to create open channels through the trabecular meshwork into Schlemm's canal to lower intraocular pressure (IOP) in a perfused anterior segment model. Methods: Human anterior segments (12 eyes) were assigned to either treatment (n = 6) or sham treatment (n = 6) groups. Both groups were perfused until a baseline IOP was recorded upon which a direct FLT treatment or a sham treatment was administered. IOP was recorded before and after the treatment. Spectral domain optical coherence tomography and second harmonic generation imaging we used to investigate the FLT channels. Results: In the FLT group, there was a significant mean decrease in the IOP of 22% compared with the pre-FLT IOP (7.13 ± 2.95 mm Hg to 5.34 ± 1.62 mm Hg; P < 0.05). In the control group, the post-sham IOP remained relatively unchanged compared with the pre-sham IOP (6.39 ± 3.69 mm Hg to 6.67 ± 4.12 mm Hg). Conclusions: The results of this study indicate that FLT treatment can significantly decrease the IOP in a perfusion model and may provide a potential noninvasive treatment option for primary open angle glaucoma. Translational Relevance: Investigating the use of femtosecond lasers for photodisrupting the trabecular meshwork can lead to a clinically relevant alternative to current glaucoma procedures.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Lasers , Tonometria Ocular , Malha Trabecular
7.
Ocul Surf ; 19: 201-209, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33075493

RESUMO

PURPOSE: While mouse models of dry eye disease (DED) have been developed, studies evaluating the role of the meibomian glands limited by the inability to temporally document changes. In this report we describe the development of a novel mouse transillumination meibography device and assess the ability of this device to detect age-related changes in the meibomian glands of young and old mice. METHODS: The mouse meibography device was comprised of a 3 mm wide right angle prism attached to broad spectrum light source by an optical fiber. Eyelids were then pulled over the prism using double tooth forceps and imaged using a stereomicroscope and low light level camera. Meibomian glands from four young and four old male, BALB/c mice were then imaged and analyzed using ImageJ. RESULTS: In young mice, meibography documented the presence of 7-8 meibomian glands appearing as black and distinct eyelid structures with the length shorter in the lower eyelid compared to the upper eyelids. Eyelids of old mice showed apparent dropout of meibomian glands along with smaller and more irregularly shaped acini. The mean acini area of one meibomian gland was 0.088 ± 0.025 mm2 in young mice and 0.080 ± 0.020 mm2 in old mice (p = 0.564), but the Meibomian gland density was significantly lower in older mice (41.7 ± 6.4%, 27.3 ± 4.2%) (p = 0.021). CONCLUSION: We have developed an in vivo meibography device that may prove useful in sequentially documenting changes during development of meibomian gland dysfunction and following treatment.


Assuntos
Doenças Palpebrais , Glândulas Tarsais , Animais , Masculino , Glândulas Tarsais/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos BALB C , Lágrimas , Transiluminação
8.
Transl Vis Sci Technol ; 9(6): 1, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32821498

RESUMO

Purpose: This study describes a femtosecond laser (FS) approach to machine corneal epithelial microchannels for enhancing riboflavin (Rf) penetration into the cornea prior to corneal crosslinking (CXL). Methods: Using a 1030-nm FS laser with 5- to 10-µJ pulse energy, the corneal epithelium of slaughterhouse rabbit eyes was machined to create 2-µm-diameter by 25-µm-long microchannels at a density of 100 or 400 channels/mm2. Rf penetration through the microchannels was then determined by applying 1% Rf in phosphate-buffered saline for 30 minutes followed by removal of the cornea and extraction from the central stromal button. Stromal Rf concentrations were then compared to those obtained using standard epithelial debridement or 0.01% benzalkonium chloride (BAK) to disrupt the epithelial barrier. Results: Microchannels formed using a 5-µJ/pulse at a density of 400 channels/mm2 achieved a stromal Rf concentration that was 50% of that achieved by removal of the corneal epithelium and imbibing with 1% Rf. Stromal Rf levels were also equal to that of debrided corneas soaked with 0.5% Rf, threefold higher than those soaked with 0.1% Rf, and twofold higher than corneas soaked in BAK without epithelial debridement. Organ culture of treated corneas showed a normal corneal epithelium following FS machining while BAK-treated corneas showed extensive epithelial and stromal damage at 24 hours posttreatment. Conclusions: FS corneal epithelial machining can be used to enhance penetration of Rf into the stroma for corneal CXL. Translational Relevance: The creation of epithelial microchannels allows for stromal Rf concentrations high enough to perform true transepithelial crosslinking.


Assuntos
Epitélio Corneano , Fármacos Fotossensibilizantes , Animais , Córnea , Epitélio Corneano/cirurgia , Lasers , Coelhos , Riboflavina
9.
Exp Eye Res ; 199: 108199, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32846150

RESUMO

Ultraviolet A (UVA) light-based photoactivation of riboflavin (Rf) to induce corneal crosslinking (CXL) and mechanical stiffening is now a well-known treatment for corneal ectasia and Keratoconus that is being used in a topographically guided photorefractive intrastromal CXL (PiXL) procedure to treat low degrees of refractive errors. Alternative approaches for non-invasive treatment of refractive errors have also been proposed that use femtosecond lasers (FS) that provide much faster, more precise, and safer results than UVA CXL. One such treatment, nonlinear optical crosslinking (NLO CXL), has been able to replicate the effects of UVA CXL, while producing a smaller area of cellular damage and requiring a shorter procedure time. Unlike UVA CXL, the treatment volume of NLO CXL only occurs within the focal volume of the laser, which can be placed at any depth and scanned into any pattern for true topographically guided refractive correction. This review presents our experience with using FS lasers to photoactivate Rf and perform highly controlled corneal CXL that leads to mechanical stiffening and changes in corneal shape.


Assuntos
Colágeno/farmacologia , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Refração Ocular/efeitos dos fármacos , Humanos , Ceratocone/fisiopatologia
10.
Transl Vis Sci Technol ; 8(6): 35, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31890347

RESUMO

PURPOSE: We have shown that nonlinear optical corneal crosslinking (NLO CXL) and stiffening can be achieved in ex vivo rabbit corneas using an 80-MHz, 760-nm femtosecond (FS) laser, however the required power was beyond the American National Standard Institute limit. The purpose of this study was to test the efficacy of amplified FS pulses to perform CXL to reduce power by increasing pulse energy. METHODS: A variable numerical aperture laser scanning delivery system was coupled to a 1030-nm laser with a noncollinear optical parametric amplifier to generate 760 nm, 50 to 150 kHz amplified FS pulses with 79.5-µm axial and 2.9-µm lateral two-photon focal volume. Ex vivo rabbit corneas received NLO CXL, and effectiveness was assessed by measuring collagen autofluorescence (CAF) and mechanical stiffening. NLO CXL was also performed in 14 live rabbits, and changes in corneal topography were measured using an Orbscan. RESULTS: Amplified pulses (0.3 µJ) generated significant CAF that increased logarithmically with decreasing scan speed; achieving equivalent CAF to UVA CXL at 15.5 mm/s. Indentation testing detected a 62% increase in stiffness compared to control, and corneal topography measurements revealed a significant decrease of 1.0 ± 0.8 diopter by 1 month (P < 0.05). CONCLUSIONS: These results show that NLO CXL using amplified pulses can produce corneal collagen CXL comparable to UVA CXL. TRANSLATIONAL RELEVANCE: NLO CXL using amplified pulses can produce corneal CXL comparable to UVA CXL, suggesting a potential clinical application in which NLO CXL can be used to perform personalized crosslinking for treatment of refractive errors and keratoconus.

11.
Acta Biomater ; 79: 96-112, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30170195

RESUMO

While tissue form and function is highly dependent upon tissue-specific collagen composition and organization, little is known of the mechanisms controlling the bundling of collagen fibrils into fibers and larger structural designs that lead to the formation of bones, tendons and other tissues. Using the cornea as a model system, our previous 3 dimensional mapping of collagen fiber organization has demonstrated that macrostructural organization of collagen fibers involving interweaving, branching and anastomosing plays a critical role in controlling mechanical stiffness, corneal shape and refractive power. In this work, the cellular and mechanical mechanisms regulating critical events in the assembly of collagen macrostructure are analysed in the developing chicken cornea. We elucidated the temporal events leading to adult corneal structure and determined the effects of intraocular pressure (IOP) on the organization of the collagen macrostructure. Our findings indicate that the complex adult collagen organization begins to appear on embryonic day 10 (E10) after deposition of the primary stroma and full invasion of keratocytes. Importantly, organizational changes in keratocytes appearing at E9 preceded and predicted later changes in collagen organization. Corneal collagen organization remained unaffected when the development of IOP was blocked at E4. These findings support a primary role for keratocytes in controlling stromal organization, mechanical stiffness and corneal shape that are not regulated by the IOP. Our findings also suggest that the avian cornea represents an excellent experimental model for elucidating key regulatory steps and mechanisms controlling the collagen fiber organization that is critical to determining tissue form and function. STATEMENT OF SIGNIFICANCE: This work by using an ex ovo model system, begins to investigate the potential mechanisms controlling collagen fibril macrostructure. In particular, this work highlights a convergent role for the corneal keratocytes in organizing the complex collagen macrostructure, necessary to support high visual acuity. Our data supports that the intraocular pressure does not influence collagen fibril macrostructure and suggest that the avian cornea represents an excellent experimental model for elucidating key regulatory steps and mechanisms controlling the collagen fiber organization that is critical to determining tissue form and function. Clearly understanding the cellular and molecular mechanisms that underlie collagen fibril macrostructure will be highly beneficial for future tissue engineering and regenerative medicine applications.


Assuntos
Córnea/crescimento & desenvolvimento , Colágenos Fibrilares/química , Morfogênese , Animais , Fenômenos Biomecânicos , Embrião de Galinha , Córnea/citologia , Substância Própria/embriologia , Pressão Intraocular
12.
Exp Eye Res ; 177: 173-180, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30118656

RESUMO

The purpose of this study was to measure collagen fiber crimping (CFC) using nonlinear optical imaging of second harmonic generated (SHG) signals to determine the effects of UVA-riboflavin induced corneal collagen crosslinking (UVA CXL) on collagen structure. Two groups, four rabbits each, were treated in the right eye with standard UVA CXL. In vivo confocal microscopy was performed at 1, 2, and 4 weeks after treatment for the first group and up to three months for the second group to measure epithelial/stromal thickness and corneal haze during recovery. Rabbits were sacrificed at one and three months, respectively, and their corneas fixed under pressure. Regions of crosslinking were identified by the presence of collagen autofluorescence (CAF) and then collagen structure was imaged using SHG microscopy. The degree of CFC was determined by measuring the percentage difference between the length of the collagen fiber and the linear distance traveled. CFC was measured in the central anterior and posterior CXL region, the peripheral non-crosslinked region in the same cornea, and the central cornea of the non-crosslinked contralateral eye. No change in corneal thickness was detected after one month, however the stromal thickness surpassed its original baseline thickness at three months by 25.9 µm. Corneal haze peaked at one month and then began to clear. Increased CAF was detected in all CXL corneas, localized to the anterior stroma and extending to 42.4 ±â€¯3.4% and 47.7 ±â€¯7.6% of the corneal thickness at one and three months. There was a significant (P < 0.05) reduction in CFC in the CAF region in all eyes averaging 1.007 ±â€¯0.006 and 1.009 ±â€¯0.005 in one and three month samples compared to 1.017 ±â€¯0.04 and 1.016 ±â€¯0.06 for controls. These results indicate that there is a significant reduction in collagen crimping following UVA CXL of approximately 1%. One possible explanation for this loss of crimping could be shortening of the collagen fibers over the CXL region.


Assuntos
Colágeno/química , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Raios Ultravioleta , Animais , Substância Própria/efeitos dos fármacos , Substância Própria/patologia , Substância Própria/efeitos da radiação , Reagentes de Ligações Cruzadas , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Epitélio Corneano/efeitos da radiação , Coelhos
13.
Exp Eye Res ; 175: 14-19, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29842851

RESUMO

PURPOSE: Previous studies indicate that there is an axial gradient of collagen lamellar branching and anastomosing leading to regional differences in corneal tissue stiffness that may control corneal shape. To further test this hypothesis we have measured the axial material stiffness and quantified the collagen lamellar complexity in ectatic and mechanically weakened keratoconus corneas (KC). METHODS: Acoustic radiation force elastic microscopy (ARFEM) was used to probe the axial mechanical properties of the cone region of three donor KC buttons. 3 Dimensional second harmonic generation microscopy (3D-SHG) was used to qualitatively evaluate lamellar organization in 3 kC buttons and quantitatively measure lamellar branching point density (BPD) in a separate KC button that had been treated with epikeratophakia (Epi-KP). RESULTS: The mean elastic modulus for the KC corneas was 1.67 ±â€¯0.44 kPa anteriorly and 0.970 ±â€¯0.30 kPa posteriorly, substantially below that previously measured for normal human cornea. 3D-SHG of KC buttons showed a simplified collagen lamellar structure lacking noticeable angled lamellae in the region of the cone. BPD in the anterior, posterior, central and paracentral regions of the KC cornea were significantly lower than in the overlying Epi-KP lenticule. Additionally, BPD in the cone region was significantly lower than the adjacent paracentral region in the KC button. CONCLUSIONS: The KC cornea exhibits an axial gradient of mechanical stiffness and a BPD that appears substantially lower in the cone region compared to normal cornea. The findings reinforce the hypothesis that collagen architecture may control corneal mechanical stiffness and hence corneal shape.


Assuntos
Colágeno/metabolismo , Córnea/fisiopatologia , Módulo de Elasticidade/fisiologia , Ceratocone/fisiopatologia , Fenômenos Biomecânicos , Técnicas de Imagem por Elasticidade , Humanos , Imageamento Tridimensional , Doadores de Tecidos
14.
Prog Retin Eye Res ; 64: 65-76, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29398348

RESUMO

Although the cornea is the major refractive element of the eye, the mechanisms controlling corneal shape and hence visual acuity remain unknown. To begin to address this question we have used multiphoton, non-linear optical microscopy to image second harmonic generated signals (SHG) from collagen to characterize the evolutionary and structural changes that occur in the collagen architecture of the corneal stroma. Our studies show that there is a progression in complexity of the stromal collagen organization from lower (fish and amphibians) to higher (birds and mammals) vertebrates, leading to increasing tissue stiffness that may control shape. In boney and cartilaginous fish, the cornea is composed of orthogonally arranged, rotating collagen sheets that extend from limbus to limbus with little or no interaction between adjacent sheets, a structural paradigm analogous to 'plywood'. In amphibians and reptiles, these sheets are broken down into broader lamellae that begin to show branching and anastomosing with adjacent lamellae, albeit maintaining their orthogonal, rotational organization. This paradigm is most complex in birds, which show the highest degree of lamellar branching and anastomosing, forming a 'chicken wire' like pattern most prominent in the midstroma. Mammals, on the other hand, diverged from the orthogonal, rotational organization and developed a random lamellar pattern with branching and anastomosing appearing highest in the anterior stroma, associated with higher mechanical stiffness compared to the posterior stroma.


Assuntos
Evolução Biológica , Substância Própria/anatomia & histologia , Vertebrados/anatomia & histologia , Animais , Fenômenos Biomecânicos , Colágeno/ultraestrutura , Substância Própria/diagnóstico por imagem , Substância Própria/fisiologia , Humanos , Microscopia Óptica não Linear/métodos , Refração Ocular/fisiologia
15.
Biomed Opt Express ; 8(10): 4788-4797, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082102

RESUMO

The purpose of this study was to develop and test a nonlinear optical device to photoactivate riboflavin to produce spatially controlled collagen crosslinking and mechanical stiffening within the cornea. A nonlinear optical device using a variable numerical aperture objective was built and coupled to a Chameleon femtosecond laser. Ex vivo rabbit eyes were then saturated with riboflavin and scanned with various scanning parameters over a 4 mm area in the central cornea. Effectiveness of NLO CXL was assessed by evaluating corneal collagen auto fluorescence (CAF). To determine mechanical stiffening effects, corneas were removed from the eye and subjected to indentation testing using a 1 mm diameter probe and force transducer. NLO CXL was also compared to standard UVA CXL. The NLO CXL delivery device was able to induce a significant increase in corneal stiffness, comparable to the increase produced by standard UVA CXL.

16.
J Cataract Refract Surg ; 42(11): 1660-1665, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27956294

RESUMO

PURPOSE: To determine whether riboflavin-induced collagen crosslinking (CXL) could be precisely achieved in the corneal stroma of ex vivo rabbit eyes using nonlinear optical excitation with a low numerical aperture lens and enlarged focal volume. SETTING: Gavin Herbert Eye Institute, University of California Irvine, Irvine, California, USA. DESIGN: Experimental study. METHODS: The corneal epithelium was removed and the corneas were soaked in 0.5% riboflavin solution. Using a 0.1 numerical aperture objective, a theoretical excitation volume of 150 µm × 3 µm was generated using 1 W of 760 nm femtosecond laser light and raster scanned with 4.4 µm line separation at varying effective speeds over a 4.50 mm × 2.25 mm area. Corneal sections were examined for collagen autofluorescence. RESULTS: Collagen autofluorescence was enhanced 2.9 times compared with ultraviolet-A (UVA) CXL. Also, increasing speed was linearly associated with decreasing autofluorescence intensity. The slowest speed of 2.69 mm/s showed a mean of 182.97 µm ± 52.35 (SD) long autofluorescent scan lines axially in the central cornea compared with 147.84 ± 4.35 µm for UVA CXL. CONCLUSIONS: Decreasing dwell time was linearly associated with decreasing autofluorescence intensity, approaching that of UVA CXL at a speed of 8.9 mm/s. Using an effective speed of 8.9 mm/s, nonlinear optical CXL could be achieved over a 3.0 mm diameter area in fewer than 4 minutes. Further development of nonlinear optical CXL might result in safer, faster, and more effective CXL treatments. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Colágeno/análise , Córnea/química , Substância Própria/química , Reagentes de Ligações Cruzadas/química , Animais , Colágeno/química , Fármacos Fotossensibilizantes , Coelhos , Riboflavina , Raios Ultravioleta
17.
Invest Ophthalmol Vis Sci ; 57(7): 3282-6, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-27327584

RESUMO

PURPOSE: The biomechanical properties of the cornea have an important role in determining the shape of the cornea and visual acuity. Since the cornea is a nonhomogeneous tissue, it is thought that the elastic properties vary throughout the cornea. We aim to measure a map of corneal elasticity across the cornea. METHODS: An acoustic radiation force elasticity microscope (ARFEM) was used to create a map of corneal elasticity in the human cornea. This ARFEM uses a low frequency, high intensity acoustic force to displace a femtosecond laser-generated microbubble, while using a high frequency, low intensity ultrasound to monitor the position of the microbubble within the cornea. From the displacement of the bubble and the magnitude of the acoustic radiation force, the local value of corneal elasticity is calculated in the direction of the displacement. Measurements were conducted at 6 locations, ranging from the central to peripheral cornea at anterior and posterior depths. RESULTS: The mean anterior elastic moduli were 4.2 ± 1.2, 3.4 ± 0.7, and 1.9 ± 0.7 kPa in the central, mid, and peripheral regions, respectively, while the posterior elastic moduli were 2.3 ± 0.7, 1.6 ± 0.3, and 2.9 ± 1.2 kPa in the same radial locations. CONCLUSIONS: We found that there is a unique distribution of elasticity axially and radially throughout the cornea.


Assuntos
Algoritmos , Simulação por Computador , Córnea/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Modelos Biológicos , Idoso de 80 Anos ou mais , Cadáver , Córnea/diagnóstico por imagem , Módulo de Elasticidade/fisiologia , Elasticidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Microscopia Acústica/métodos , Reprodutibilidade dos Testes
18.
Ultrasound Med Biol ; 40(7): 1671-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24726798

RESUMO

To investigate the role of collagen structure in corneal biomechanics, measurement of localized corneal elasticity with minimal destruction to the tissue is necessary. We adopted the recently developed acoustic radiation force elastic microscopy (ARFEM) technique to measure localize biomechanical properties of the human cornea. In ARFEM, a low-frequency, high-intensity acoustic force is used to displace a femtosecond laser-generated microbubble, while high-frequency, low-intensity ultrasound is used to monitor the position of the microbubble within the cornea. Two ex vivo human corneas from a single donor were dehydrated to physiologic thickness, embedded in gelatin and then evaluated using the ARFEM technique. In the direction perpendicular to the corneal surface, ARFEM measurements provided elasticity values of E = 1.39 ± 0.28 kPa for the central anterior cornea and E = 0.71 ± 0.21 kPa for the central posterior cornea in pilot studies. The increased value of corneal elasticity in the anterior cornea correlates with the higher density of interweaving lamellae in this region.


Assuntos
Córnea/diagnóstico por imagem , Córnea/fisiologia , Técnicas de Diagnóstico Oftalmológico , Técnicas de Imagem por Elasticidade/métodos , Testes de Dureza/métodos , Interpretação de Imagem Assistida por Computador/métodos , Microscopia Acústica/métodos , Algoritmos , Cadáver , Simulação por Computador , Módulo de Elasticidade/fisiologia , Humanos , Técnicas In Vitro , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Biomed Opt ; 16(10): 108001, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22029369

RESUMO

We have developed a two-dimensional computer model to predict the temperature increase of the retina during femtosecond corneal laser flap cutting. Simulating a typical clinical setting for 150-kHz iFS advanced femtosecond laser (0.8- to 1-µJ laser pulse energy and 15-s procedure time at a laser wavelength of 1053 nm), the temperature increase is 0.2°C. Calculated temperature profiles show good agreement with data obtained from ex vivo experiments using human cadaver retina. Simulation results obtained for different commercial femtosecond lasers indicate that during the laser in situ keratomileusis procedure the temperature increase of the retina is insufficient to induce damage.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Retina/lesões , Cadáver , Simulação por Computador , Análise de Elementos Finitos , Temperatura Alta/efeitos adversos , Humanos , Técnicas In Vitro , Modelos Biológicos , Fenômenos Ópticos , Retina/fisiologia , Retina/efeitos da radiação , Temperatura , Fatores de Tempo
20.
J Cataract Refract Surg ; 37(2): 386-91, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21241925

RESUMO

PURPOSE: To measure the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser as a model for laser exposure of the iris during femtosecond laser corneal surgery. SETTING: Department of Ophthalmology, University of California-Irvine, Irvine, California, USA. DESIGN: Experimental study. METHODS: The temperature increase induced by a 60 kHz commercial femtosecond laser in porcine cadaver iris was measured in situ using an infrared thermal imaging camera at pulse energy levels ranging from 1 to 2 µJ (corresponding approximately to surgical energies of 2 to 4 µJ per laser pulse). RESULTS: Temperature increases up to 2.3 °C (corresponding to 2 µJ and 24-second illumination) were observed in the porcine cadaver iris with little variation in temperature profiles between specimens for the same laser energy illumination. CONCLUSIONS: The 60 kHz commercial femtosecond laser operating with pulse energies at approximately the lower limit of the range evaluated in this study would be expected to result in a 1.2 °C temperature increase and therefore does not present a safety hazard to the iris.


Assuntos
Temperatura Corporal/efeitos da radiação , Iris/fisiologia , Iris/efeitos da radiação , Lasers , Animais , Cadáver , Simulação por Computador , Córnea/cirurgia , Técnicas In Vitro , Terapia a Laser , Modelos Biológicos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA