Altern Lab Anim ; : 2611929241270095, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39168512

RESUMO

This study introduces a novel in vitro methodology that employs the 3-D reconstructed tissue model, EpiOcular, to assess the irritation and phototoxicity potential of medical devices and drugs in contact with the eye. Our study evaluated diverse test materials, including medical devices, ophthalmological solutions and an experimental drug (cemtirestat), for their potential to cause eye irritation and phototoxicity. The protocols used in this study with the EpiOcular tissue model were akin to those used in the ultra-mildness testing of cosmetic formulations, which is challenging to predict with standard in vivo rabbit tests. To design these protocols, we leveraged experience gained from the validation project on the EpiDerm skin irritation test for medical devices (ISO 10993-23:2021) and the OECD TG 498 method for photo-irritation testing. The predictions were based on the tissue viability and inflammatory response, as determined by IL-1α release. By developing and evaluating these protocols for medical devices, we aimed to expand the applicability domain of the tests referred to in ISO 10993-23. This will contribute to the standardisation and cost-effective safety evaluation of ophthalmic products, while reducing reliance on animal testing in this field. The findings obtained from the EpiOcular model in the photo-irritation test could support its implementation in the testing strategies outlined in OECD TG 498.

2.
Toxicol In Vitro ; 50: 407-417, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29438733

RESUMO

Assessment of dermal irritation is an essential component of the safety evaluation of medical devices. Reconstructed human epidermis (RhE) models have replaced rabbit skin irritation testing for neat chemicals and their mixtures (OECD Test Guideline 439). However, this guideline cannot be directly applied to the area of medical devices (MD) since their non-toxicity assessment is largely based on the testing of MD extracts that may have very low irritation potential. Therefore, the RhE-methods previously validated with neat chemicals needed to be modified to reflect the needs for detection of low levels of potential irritants. A protocol employing RhE EpiDerm was optimized in 2013 using known irritants and spiked polymers (Casas et al., 2013, TIV). In 2014 and 2015 MatTek In Vitro Life Science Laboratories (IVLSL) and RIVM assessed the transferability of the assay. After the successful transfer and standardization of the protocol, 17 laboratories were trained in the use of the protocol in the preparation for the validation. Laboratories produced data with 98% agreement of predictions for the selected references and controls. We conclude that a modified RhE skin irritation test has the potential to address the skin irritation potential of the medical devices. Standardization and focus on the technical issues is essential for accurate prediction.


Assuntos
Epiderme/efeitos dos fármacos , Equipamentos e Provisões , Irritantes/toxicidade , Polímeros/toxicidade , Testes de Irritação da Pele , Alternativas aos Testes com Animais , Epiderme/metabolismo , Humanos , Interleucina-1alfa/metabolismo , Reprodutibilidade dos Testes