1.
Phys Med Biol ; 69(20)2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39299266

RESUMO

Objective. Real-time adaptive particle therapy is being investigated as a means to maximize the treatment delivery accuracy. To react to dosimetric errors, a system for fast and reliable verification of the agreement between planned and delivered doses is essential. This study presents a clinically feasible, real-time 4D-dose reconstruction system, synchronized with the treatment delivery and motion of the patient, which can provide the necessary feedback on the quality of the delivery.Approach. A GPU-based analytical dose engine capable of millisecond dose calculation for carbon ion therapy has been developed and interfaced with the next generation of the dose delivery system (DDS) in use at Centro Nazionale di Adroterapia Oncologica (CNAO). The system receives the spot parameters and the motion information of the patient during the treatment and performs the reconstruction of the planned and delivered 4D-doses. After each iso-energy layer, the results are displayed on a graphical user interface by the end of the spill pause of the synchrotron, permitting verification against the reference dose. The framework has been verified experimentally at CNAO for a lung cancer case based on a virtual phantom 4DCT. The patient's motion was mimicked by a moving Ionization Chamber (IC) 2D-array.Mainresults. For the investigated static and 4D-optimized treatment delivery cases, real-time dose reconstruction was achieved with an average pencil beam dose calculation speed up to more than one order of magnitude smaller than the spot delivery. The reconstructed doses have been benchmarked against offline log-file based dose reconstruction with the TRiP98 treatment planning system, as well as QA measurements with the IC 2D-array, where an average gamma-index passing rate (3%/3 mm) of 99.8% and 98.3%, respectively, were achieved.Significance. This work provides the first real-time 4D-dose reconstruction engine for carbon ion therapy. The framework integration with the CNAO DDS paves the way for a swift transition to the clinics.


Assuntos
Radioterapia com Íons Pesados , Dosagem Radioterapêutica , Humanos , Radioterapia com Íons Pesados/métodos , Fatores de Tempo , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento , Doses de Radiação , Tomografia Computadorizada Quadridimensional , Imagens de Fantasmas , Neoplasias Pulmonares/radioterapia , Radiometria/métodos
2.
Phys Med ; 60: 139-149, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31000074

RESUMO

PURPOSE: To describe a new system for scanned ion beam therapy, named RIDOS (Real-time Ion DOse planning and delivery System), which performs real time delivered dose verification integrating the information from a clinical beam monitoring system with a Graphic Processing Unit (GPU) based dose calculation in patient Computed Tomography. METHODS: A benchmarked dose computation algorithm for scanned ion beams has been parallelized and adapted to run on a GPU architecture. A workstation equipped with a NVIDIA GPU has been interfaced through a National Instruments PXI-crate with the dose delivery system of the Italian National Center of Oncological Hadrontherapy (CNAO) to receive in real-time the measured beam parameters. Data from a patient monitoring system are also collected to associate the respiratory phases with each spot during the delivery of the dose. Using both measured and planned spot properties, RIDOS evaluates during the few seconds of inter-spill time the cumulative delivered and prescribed dose distributions and compares them through a fast γ-index algorithm. RESULTS: The accuracy of the GPU-based algorithms was assessed against the CPU-based ones and the differences were found below 1‰. The cumulative planned and delivered doses are computed at the end of each spill in about 300 ms, while the dose comparison takes approximatively 400 ms. The whole operation provides the results before the next spill starts. CONCLUSIONS: RIDOS system is able to provide a fast computation of the delivered dose in the inter-spill time of the CNAO facility and allows to monitor online the dose deposition accuracy all along the treatment.


Assuntos
Algoritmos , Íons/uso terapêutico , Sistemas On-Line , Dosagem Radioterapêutica , Computadores , Humanos , Respiração , Síncrotrons , Fatores de Tempo
3.
Phys Med Biol ; 61(1): 183-214, 2016 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-26630246

RESUMO

The calculation algorithm of a modern treatment planning system for ion-beam radiotherapy should ideally be able to deal with different ion species (e.g. protons and carbon ions), to provide relative biological effectiveness (RBE) evaluations and to describe different beam lines. In this work we propose a new approach for ion irradiation outcomes computations, the beamlet superposition (BS) model, which satisfies these requirements. This model applies and extends the concepts of previous fluence-weighted pencil-beam algorithms to quantities of radiobiological interest other than dose, i.e. RBE- and LET-related quantities. It describes an ion beam through a beam-line specific, weighted superposition of universal beamlets. The universal physical and radiobiological irradiation effect of the beamlets on a representative set of water-like tissues is evaluated once, coupling the per-track information derived from FLUKA Monte Carlo simulations with the radiobiological effectiveness provided by the microdosimetric kinetic model and the local effect model. Thanks to an extension of the superposition concept, the beamlet irradiation action superposition is applicable for the evaluation of dose, RBE and LET distributions. The weight function for the beamlets superposition is derived from the beam phase space density at the patient entrance. A general beam model commissioning procedure is proposed, which has successfully been tested on the CNAO beam line. The BS model provides the evaluation of different irradiation quantities for different ions, the adaptability permitted by weight functions and the evaluation speed of analitical approaches. Benchmarking plans in simple geometries and clinical plans are shown to demonstrate the model capabilities.


Assuntos
Algoritmos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Eficiência Biológica Relativa
4.
Phys Med Biol ; 59(23): 7393-417, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25386876

RESUMO

The relative biological effectiveness (RBE) concept is commonly used in treatment planning for ion beam therapy. Whether models based on in vitro/in vivo RBE data can be used to predict human response to treatments is an open issue. In this work an alternative method, based on an effective radiobiological parameterization directly derived from clinical data, is presented. The method has been applied to the analysis of prostate cancer trials with protons and carbon ions.Prostate cancer trials with proton and carbon ion beams reporting 5 year-local control (LC5) and grade 2 (G2) or higher genitourinary toxicity rates (TOX) were selected from literature to test the method. Treatment simulations were performed on a representative subset of patients to produce dose and linear energy transfer distribution, which were used as explicative physical variables for the radiobiological modelling. Two models were taken into consideration: the microdosimetric kinetic model (MKM) and a linear model (LM). The radiobiological parameters of the LM and MKM were obtained by coupling them with the tumor control probability and normal tissue complication probability models to fit the LC5 and TOX data through likelihood maximization. The model ranking was based on the Akaike information criterion.Results showed large confidence intervals due to the limited variety of available treatment schedules. RBE values, such as RBE = 1.1 for protons in the treated volume, were derived as a by-product of the method, showing a consistency with current approaches. Carbon ion RBE values were also derived, showing lower values than those assumed for the original treatment planning in the target region, whereas higher values were found in the bladder. Most importantly, this work shows the possibility to infer the radiobiological parametrization for proton and carbon ion treatment directly from clinical data.


Assuntos
Neoplasias da Próstata/radioterapia , Terapia com Prótons , Humanos , Masculino , Eficiência Biológica Relativa
5.
Phys Med Biol ; 56(13): 3749-72, 2011 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-21628776

RESUMO

Computational anthropomorphic human phantoms are useful tools developed for the calculation of absorbed or equivalent dose to radiosensitive organs and tissues of the human body. The problem is, however, that, strictly speaking, the results can be applied only to a person who has the same anatomy as the phantom, while for a person with different body mass and/or standing height the data could be wrong. In order to improve this situation for many areas in radiological protection, this study developed 18 anthropometric standing adult human phantoms, nine models per gender, as a function of the 10th, 50th and 90th mass and height percentiles of Caucasian populations. The anthropometric target parameters for body mass, standing height and other body measures were extracted from PeopleSize, a well-known software package used in the area of ergonomics. The phantoms were developed based on the assumption of a constant body-mass index for a given mass percentile and for different heights. For a given height, increase or decrease of body mass was considered to reflect mainly the change of subcutaneous adipose tissue mass, i.e. that organ masses were not changed. Organ mass scaling as a function of height was based on information extracted from autopsy data. The methods used here were compared with those used in other studies, anatomically as well as dosimetrically. For external exposure, the results show that equivalent dose decreases with increasing body mass for organs and tissues located below the subcutaneous adipose tissue layer, such as liver, colon, stomach, etc, while for organs located at the surface, such as breasts, testes and skin, the equivalent dose increases or remains constant with increasing body mass due to weak attenuation and more scatter radiation caused by the increasing adipose tissue mass. Changes of standing height have little influence on the equivalent dose to organs and tissues from external exposure. Specific absorbed fractions (SAFs) have also been calculated with the 18 anthropometric phantoms. The results show that SAFs decrease with increasing height and increase with increasing body mass. The calculated data suggest that changes of the body mass may have a significant effect on equivalent doses, primarily for external exposure to organs and tissue located below the adipose tissue layer, while for superficial organs, for changes of height and for internal exposures the effects on equivalent dose are small to moderate.


Assuntos
Estatura , Peso Corporal , Imagens de Fantasmas , Postura , Radiometria/instrumentação , População Branca , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Proteção Radiológica , Irradiação Corporal Total , Adulto Jovem
6.
J Biol Phys ; 33(2): 155-60, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19669547

RESUMO

The effects of gamma radiation from (60)Co and (137)Cs on DNA in aqueous solution are studied experimentally. Using an improved plasmid purification protocol and improved electrophoretic gel analysis techniques provided results with relatively small uncertainties. The results are compared with both theoretical and experimental results. In particular, the results obtained here are discussed in the light of recent discussion on supposed differences of the effects induced by gamma radiation from (60)Co and (137)Cs. We find that the effects of both types of gamma radiation are similar.

7.
Environ Pollut ; 145(1): 279-92, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16777290

RESUMO

Tillandsia usneoides L. is an epiphytic bromeliad plant able to absorb water and nutrients directly from the air. For this reason this species was selected to carry out a monitoring study of air pollution in the metropolitan region of São Paulo, Brazil. Five consecutive transplantation experiments (8 weeks each) were performed in 10 sites of the city, submitted to different sources of air pollution (industrial, vehicular), using plants collected from an unpolluted area. After exposure, trace metals were analyzed in the plant by instrumental neutron activation analysis. Traffic-related elements such as Zn and Ba presented high concentrations in exposure sites near to heavy traffic avenues (cars, buses and trucks) and may be associated to vehicular sources. For Zn and Co the highest contents were related to industrial zones and can be associated to the presence of anthropogenic emission sources. The rare earth elements, Fe and Rb, probably have soil particles as main source.


Assuntos
Poluentes Atmosféricos/análise , Metais/análise , Tillandsia/química , Bário/análise , Biomarcadores/análise , Brasil , Cidades , Cobalto/análise , Exposição Ambiental/efeitos adversos , Monitoramento Ambiental/métodos , Indústrias , Ferro/análise , Análise de Ativação de Nêutrons/métodos , Medição de Risco/métodos , Rubídio/análise , Poluentes do Solo/análise , Emissões de Veículos/análise , Zinco/análise
SELEÇÃO DE REFERÊNCIAS