Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Polymers (Basel) ; 16(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38794609

RESUMO

Over the last decade, researchers have developed a variety of new analytical and clinical diagnostic devices. These devices are predominantly based on microfluidic technologies, where biological samples can be processed and manipulated for the collection and detection of important biomolecules. Polydimethylsiloxane (PDMS) is the most commonly used material in the fabrication of these microfluidic devices. However, it has a hydrophobic nature (contact angle with water of 110°), leading to poor wetting behavior and issues related to the mixing of fluids, difficulties in obtaining uniform coatings, and reduced efficiency in processes such as plasma separation and molecule detection (protein adsorption). This work aimed to consider the fabrication aspects of PDMS microfluidic devices for biological applications, such as surface modification methods. Therefore, we studied and characterized two methods for obtaining hydrophilic PDMS surfaces: surface modification by bulk mixture and the surface immersion method. To modify the PDMS surface properties, three different surfactants were used in both methods (Pluronic® F127, polyethylene glycol (PEG), and polyethylene oxide (PEO)) at different percentages. Water contact angle (WCA) measurements were performed to evaluate the surface wettability. Additionally, capillary flow studies were performed with microchannel molds, which were produced using stereolithography combined with PDMS double casting and replica molding procedures. A PDMS microfluidic device for blood plasma separation was also fabricated by soft lithography with PDMS modified by PEO surfactant at 2.5% (v/v), which proved to be the best method for making the PDMS hydrophilic, as the WCA was lower than 50° for several days without compromising the PDMS's optical properties. Thus, this study indicates that PDMS surface modification shows great potential for enhancing blood plasma separation efficiency in microfluidic devices, as it facilitates fluid flow, reduces cell aggregations and the trapping of air bubbles, and achieves higher levels of sample purity.

2.
Biosensors (Basel) ; 14(4)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38667152

RESUMO

This work reports on the surface functionalization of a nanomaterial supporting localized surface plasmon resonances (LSPRs) with (synthetic) thiolated oligonucleotide-based biorecognition elements, envisaging the development of selective LSPR-based DNA biosensors. The LSPR thin-film transducers are composed of noble metal nanoparticles (NPs) embedded in a TiO2 dielectric matrix, produced cost-effectively and sustainably by magnetron sputtering. The study focused on the immobilization kinetics of thiolated oligonucleotide probes as biorecognition elements, followed by the evaluation of hybridization events with the target probe. The interaction between the thiolated oligonucleotide probe and the transducer's surface was assessed by monitoring the LSPR signal with successive additions of probe solution through a microfluidic device. The device was specifically designed and fabricated for this work and adapted to a high-resolution LSPR spectroscopy system with portable characteristics. Benefiting from the synergetic characteristics of Ag and Au in the form of bimetallic nanoparticles, the Au-Ag/TiO2 thin film proved to be more sensitive to thiolated oligonucleotide binding events. Despite the successful surface functionalization with the biorecognition element, the detection of complementary oligonucleotides revealed electrostatic repulsion and steric hindrance, which hindered hybridization with the target oligonucleotide. This study points to an effect that is still poorly described in the literature and affects the design of LSPR biosensors based on nanoplasmonic thin films.


Assuntos
Técnicas Biossensoriais , Ouro , Nanopartículas Metálicas , Oligonucleotídeos , Prata , Ressonância de Plasmônio de Superfície , Titânio , Titânio/química , Ouro/química , Prata/química , Nanopartículas Metálicas/química , Oligonucleotídeos/química , Compostos de Sulfidrila/química , DNA , Hibridização de Ácido Nucleico
3.
Micromachines (Basel) ; 14(6)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37374730

RESUMO

Machine learning (ML) is a broad term encompassing several methods that allow us to learn from data. These methods may permit large real-world databases to be more rapidly translated to applications to inform patient-provider decision-making. This paper presents a review of articles that discuss the use of Fourier transform infrared (FTIR) spectroscopy and ML for human blood analysis between the years 2019-2023. The literature review was conducted to identify published research of employed ML linked with FTIR for distinction between pathological and healthy human blood cells. The articles' search strategy was implemented and studies meeting the eligibility criteria were evaluated. Relevant data related to the study design, statistical methods, and strengths and limitations were identified. A total of 39 publications in the last 5 years (2019-2023) were identified and evaluated for this review. Diverse methods, statistical packages, and approaches were used across the identified studies. The most common methods included support vector machine (SVM) and principal component analysis (PCA) approaches. Most studies applied internal validation and employed more than one algorithm, while only four studies applied one ML algorithm to the data. A wide variety of approaches, algorithms, statistical software, and validation strategies were employed in the application of ML methods. There is a need to ensure that multiple ML approaches are used, the model selection strategy is clearly defined, and both internal and external validation are necessary to be sure that the discrimination of human blood cells is being made with the highest efficient evidence.

4.
IEEE Trans Biomed Eng ; 70(8): 2318-2328, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37022426

RESUMO

OBJECTIVES: Optical spectrophotometry has been explored to quantify Plasmodium falciparum malaria parasites at low parasitemia, with potential to overcome the limitations of detection in the current diagnostic methods. This work presents the design, simulation and fabrication of a CMOS microelectronic detection system to automatically quantify the presence of malaria parasites in a blood sample. METHODS: The designed system is composed by an array of 16 n+/p-substrate silicon junction photodiodes as photodetectors and 16 current to frequency (IF) converters. An optical setup was used to individually and jointly characterize the entire system. RESULTS: The IF converter was simulated and characterized in Cadence Tools using UMC 1180 MM/RF technology rules, featuring a resolution of 0.01 nA, a linearity up to 1800 nA and a sensitivity of 4430 Hz/nA. After fabrication in a silicon foundry, the photodiodes' characterization presented a responsivity peak of 120 mA/W (λ = 570 nm) and a dark current of 7.15 pA at 0 V. Regarding the IF converter, it exhibited high linearity (R2 ≈ 0.999) up to 30 nA, with a sensitivity of 4840 Hz/nA. Furthermore, the microsystem performance was validated using RBCs (Red Blood Cells) infected with P. falciparum and diluted at different parasitemia (12, 25 and 50 parasites/µL). CONCLUSION: The microsystem was able to distinguish between healthy and infected RBCs, with a sensitivity of 4.5 Hz/parasites.µL-1. SIGNIFICANCE: The developed microsystem presents a competitive result, when compared to the gold standard diagnosis methods, with increased potential for malaria in field diagnosis.


Assuntos
Malária Falciparum , Malária , Humanos , Plasmodium falciparum , Silício , Parasitemia/diagnóstico , Parasitemia/parasitologia , Malária/diagnóstico , Malária Falciparum/diagnóstico , Malária Falciparum/parasitologia , Espectrofotometria , Sensibilidade e Especificidade
5.
Pharmaceutics ; 15(3)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36986653

RESUMO

Microneedles (MNs) have been widely used in biomedical applications for drug delivery and biomarker detection purposes. Furthermore, MNs can also be used as a stand-alone tool to be combined with microfluidic devices. For that purpose, lab- or organ-on-a-chip are being developed. This systematic review aims to summarize the most recent progress in these emerging systems, to identify their advantages and limitations, and discuss promising potential applications of MNs in microfluidics. Therefore, three databases were used to search papers of interest, and their selection was made following the guidelines for systematic reviews proposed by PRISMA. In the selected studies, the MNs type, fabrication strategy, materials, and function/application were evaluated. The literature reviewed showed that although the use of MNs for lab-on-a-chip has been more explored than for organ-on-a-chip, some recent studies have explored this applicability with great potential for the monitoring of organ models. Overall, it is shown that the presence of MNs in advanced microfluidic devices can simplify drug delivery and microinjection, as well as fluid extraction for biomarker detection by using integrated biosensors, which is a promising tool to precisely monitor, in real-time, different kinds of biomarkers in lab- and organ-on-a-chip platforms.

6.
Sensors (Basel) ; 23(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36850801

RESUMO

The ocean has a huge impact on our way of life; therefore, there is a need to monitor and protect its biodiversity [...].


Assuntos
Biodiversidade , Oceanos e Mares
7.
ACS Infect Dis ; 9(1): 140-149, 2023 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-36490289

RESUMO

Malaria is one of the most life-threatening infectious diseases worldwide, claiming half a million lives yearly. Prompt and accurate diagnosis is crucial for disease control and elimination. Currently used diagnostic methods require blood sampling and fail to detect low-level infections. At the symptomatic stage of infection, the parasites feed on red blood cells' (RBCs) hemoglobin, forming inert crystals, the hemozoin, in the process. Thus, along with parasite maturation inside the RBCs, the hemoglobin and hemozoin proportion is inversely related, and they generate specific optical spectra, according to their concentration. Herein, to address the issues of finger prick sampling and the lack of sensitivity of the parasitological test, we explored the optical features of Plasmodium falciparum-infected RBCs through absorbance and reflectance spectrophotometric characterization, aiming for their detection. This is the first work fully characterizing the spectrophotometric properties of P. falciparum-infected RBCs by using only 16 specific wavelengths within the visible optical spectra and two different post-processing algorithms. With such an innovative methodology, low-level infections can be detected and quantified, and early- and late-stage development can be clearly distinguished, not only improving the current detection limits but also proving the successful applicability of spectrophotometry for competitive and accurate malaria diagnosis.


Assuntos
Malária Falciparum , Malária , Parasitos , Animais , Plasmodium falciparum , Malária Falciparum/diagnóstico , Malária Falciparum/parasitologia , Malária/parasitologia , Espectrofotometria
8.
Bioengineering (Basel) ; 9(12)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36550986

RESUMO

With more than 1.5 million total knee and hip implants placed each year, there is an urgent need for a drug delivery system that can effectively support the repair of bone infections. Scaffolds made of natural biopolymers are widely used for this purpose due to their biocompatibility, biodegradability, and suitable mechanical properties. However, the poor processability is a bottleneck, as highly customizable scaffolds are desired. The aim of the present research is to develop a scaffold made of thermoplastic collagen (TC) using 3D printing technology. The viscosity of the material was measured using a rheometer. A 3D bioplotter was used to fabricate the scaffolds out of TC. The mechanical properties of the TC scaffolds were performed using tension/compression testing on a Zwick/Roell universal testing machine. TC shows better compressibility with increasing temperature and a decrease in dynamic viscosity (η), storage modulus (G'), and loss modulus (G″). The compressive strength of the TC scaffolds was between 3-10 MPa, depending on the geometry (cylinder or cuboid, with different infills). We have demonstrated for the first time that TC can be used to fabricate porous scaffolds by 3D printing in various geometries.

9.
Micromachines (Basel) ; 13(8)2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36014271

RESUMO

At the end of 2019, the coronavirus appeared and spread extremely rapidly, causing millions of infections and deaths worldwide, and becoming a global pandemic. For this reason, it became urgent and essential to find adequate tests for an accurate and fast diagnosis of this disease. In the present study, a systematic review was performed in order to provide an overview of the COVID-19 diagnosis methods and tests already available, as well as their evolution in recent months. For this purpose, the Science Direct, PubMed, and Scopus databases were used to collect the data and three authors independently screened the references, extracted the main information, and assessed the quality of the included studies. After the analysis of the collected data, 34 studies reporting new methods to diagnose COVID-19 were selected. Although RT-PCR is the gold-standard method for COVID-19 diagnosis, it cannot fulfill all the requirements of this pandemic, being limited by the need for highly specialized equipment and personnel to perform the assays, as well as the long time to get the test results. To fulfill the limitations of this method, other alternatives, including biological and imaging analysis methods, also became commonly reported. The comparison of the different diagnosis tests allowed to understand the importance and potential of combining different techniques, not only to improve diagnosis but also for a further understanding of the virus, the disease, and their implications in humans.

10.
Biomed Microdevices ; 24(2): 20, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35670892

RESUMO

The efficient separation of blood components using microfluidic systems can help to improve the detection and diagnosis of several diseases, such as malaria and diabetes. Therefore, a novel multi-step microfluidic device, based on passive crossflow filters was developed. Three different designs were proposed, fabricated and tested in order to evaluate the most suitable geometry to perform, simultaneously, blood cells separation and cell deformability measurements. All the proposed geometries include a main channel and three sequential separation steps, all comprised of symmetrical crossflow filters, with multiple rows of pillars, to reduce the amount of red blood cells (RBCs) flowing to the outlets of the microfluidic device (MD). Sets of hyperbolic constrictions located at the outlets allow the assessment of cells deformability. Based on the proposed geometries, the three correspondent MD were evaluated and compared, by measuring the RBCs velocities, the cell-free layer (CFL) effect through the microchannels and by quantifying the amount of RBCs at the outlets. The results suggest that the proposed MD 3 configuration was the most effective one for the desired application, due to the formation of a wider CFL. As a result, a minor amount of RBCs flow through the hyperbolic contraction at the third separation level of the device. Nevertheless, for all the proposed geometries, the existence of three separation levels shows that it is possible to achieve a highly efficient cell separation. If needed, such microdevices have the potential for further improvements by increasing the number of separation levels, aiming the total separation of blood cells from plasma.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Separação Celular , Contagem de Eritrócitos , Deformação Eritrocítica , Eritrócitos
11.
Cancers (Basel) ; 14(4)2022 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-35205683

RESUMO

The development of cancer models that rectify the simplicity of monolayer or static cell cultures physiologic microenvironment and, at the same time, replicate the human system more accurately than animal models has been a challenge in biomedical research. Organ-on-a-chip (OoC) devices are a solution that has been explored over the last decade. The combination of microfluidics and cell culture allows the design of a dynamic microenvironment suitable for the evaluation of treatments' efficacy and effects, closer to the response observed in patients. This systematic review sums the studies from the last decade, where OoC with cancer cell cultures were used for drug screening assays. The studies were selected from three databases and analyzed following the research guidelines for systematic reviews proposed by PRISMA. In the selected studies, several types of cancer cells were evaluated, and the majority of treatments tested were standard chemotherapeutic drugs. Some studies reported higher drug resistance of the cultures on the OoC devices than on 2D cultures, which indicates the better resemblance to in vivo conditions of the former. Several studies also included the replication of the microvasculature or the combination of different cell cultures. The presence of vasculature can influence positively or negatively the drug efficacy since it contributes to a greater diffusion of the drug and also oxygen and nutrients. Co-cultures with liver cells contributed to the evaluation of the systemic toxicity of some drugs metabolites. Nevertheless, few studies used patient cells for the drug screening assays.

12.
Biosensors (Basel) ; 12(2)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35200370

RESUMO

Despite being preventable and treatable, malaria still puts almost half of the world's population at risk. Thus, prompt, accurate and sensitive malaria diagnosis is crucial for disease control and elimination. Optical microscopy and immuno-rapid tests are the standard malaria diagnostic methods in the field. However, these are time-consuming and fail to detect low-level parasitemia. Biosensors and lab-on-a-chip devices, as reported to different applications, usually offer high sensitivity, specificity, and ease of use at the point of care. Thus, these can be explored as an alternative for malaria diagnosis. Alongside malaria infection inside the human red blood cells, parasites consume host hemoglobin generating the hemozoin crystal as a by-product. Hemozoin is produced in all parasite species either in symptomatic and asymptomatic individuals. Furthermore, hemozoin crystals are produced as the parasites invade the red blood cells and their content relates to disease progression. Hemozoin is, therefore, a unique indicator of infection, being used as a malaria biomarker. Herein, the so-far developed biosensors and lab-on-a-chip devices aiming for malaria detection by targeting hemozoin as a biomarker are reviewed and discussed to fulfil all the medical demands for malaria management towards elimination.


Assuntos
Hemeproteínas , Malária , Biomarcadores , Eritrócitos/parasitologia , Eritrócitos/fisiologia , Hemeproteínas/metabolismo , Humanos , Malária/sangue , Malária/diagnóstico , Malária/parasitologia
13.
Micromachines (Basel) ; 13(2)2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35208311

RESUMO

Since microorganisms are evolving rapidly, there is a growing need for a new, fast, and precise technique to analyse blood samples and distinguish healthy from pathological samples. Fourier Transform Infrared (FTIR) spectroscopy can provide information related to the biochemical composition and how it changes when a pathological state arises. FTIR spectroscopy has undergone rapid development over the last decades with a promise of easier, faster, and more impartial diagnoses within the biomedical field. However, thus far only a limited number of studies have addressed the use of FTIR spectroscopy in this field. This paper describes the main concepts related to FTIR and presents the latest research focusing on FTIR spectroscopy technology and its integration in lab-on-a-chip devices and their applications in the biological field. This review presents the potential use of FTIR to distinguish between healthy and pathological samples, with examples of early cancer detection, human immunodeficiency virus (HIV) detection, and routine blood analysis, among others. Finally, the study also reflects on the features of FTIR technology that can be applied in a lab-on-a-chip format and further developed for small healthcare devices that can be used for point-of-care monitoring purposes. To the best of the authors' knowledge, no other published study has reviewed these topics. Therefore, this analysis and its results will fill this research gap.

14.
Micromachines (Basel) ; 13(2)2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35208368

RESUMO

The development of micro- and nanodevices for blood analysis continues to be a growing interdisciplinary subject that demands the careful integration of different research fields [...].

15.
Sensors (Basel) ; 21(16)2021 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-34451087

RESUMO

The advanced and widespread use of microfluidic devices, which are usually fabricated in polydimethylsiloxane (PDMS), requires the integration of many sensors, always compatible with microfluidic fabrication processes. Moreover, current limitations of the existing optical and electrochemical oxygen sensors regarding long-term stability due to sensor degradation, biofouling, fabrication processes and cost have led to the development of new approaches. Thus, this manuscript reports the development, fabrication and characterization of a low-cost and highly sensitive dissolved oxygen optical sensor based on a membrane of PDMS doped with platinum octaethylporphyrin (PtOEP) film, fabricated using standard microfluidic materials and processes. The excellent mechanical and chemical properties (high permeability to oxygen, anti-biofouling characteristics) of PDMS result in membranes with superior sensitivity compared with other matrix materials. The wide use of PtOEP in sensing applications, due to its advantage of being easily synthesized using microtechnologies, its strong phosphorescence at room temperature with a quantum yield close to 50%, its excellent Strokes Shift as well as its relatively long lifetime (75 µs), provide the suitable conditions for the development of a miniaturized luminescence optical oxygen sensor allowing long-term applications. The influence of the PDMS film thickness (0.1-2.5 mm) and the PtOEP concentration (363, 545, 727 ppm) in luminescent properties are presented. This enables to achieve low detection levels in a gas media range from 0.5% up to 20%, and in liquid media from 0.5 mg/L up to 3.3 mg/L at 1 atm, 25 °C. As a result, we propose a simple and cost-effective system based on a LED membrane photodiode system to detect low oxygen concentrations for in situ applications.


Assuntos
Platina , Porfirinas , Dimetilpolisiloxanos , Oxigênio
16.
Micromachines (Basel) ; 12(8)2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34442510

RESUMO

Malaria diagnosis relies on optical microscopy and/or rapid diagnostic tests based on detecting specific malaria antigens. The clinical sensitivity of these methods is highly dependent on parasite density, with low levels of detection at low parasite density, challenging the worldwide malaria elimination efforts. Therefore, there is a need for diagnostic methods with higher sensitivity, demanding innovative diagnostics devices able to detect malaria at low parasite density and at early stages of the disease. We propose an innovative optical device for malaria diagnosis, based on optical reflectance spectrophotometry, for the detection of parasites through the quantification of haemozoin. For this purpose, a set of eight thin-film optical filters, based on multilayer stacks of MgO/TiO2 and SiO2/TiO2 thin-films, with high transmittance and low full width at half maximum (FWHM) at specific wavelengths, was designed and fully characterized (both numerically and experimentally). A preliminary assessment of its potential to reconstruct the original spectra of red blood cells was performed, both in uninfected and Plasmodium falciparum-infected samples. The obtained results show that, although the experimental filters have a non-ideal performance characteristic, they allow us to distinguish, based on only 8 discrete points in the optical spectrum, between healthy and malaria infected samples, up to a detection limit of 12 parasites/µL of red blood cells. Those results enhance the potential of using such a device for malaria diagnostics, aiming for non-invasiveness.

17.
Sensors (Basel) ; 21(9)2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-34068811

RESUMO

Three-dimensional (3D) in vitro models, such as organ-on-a-chip platforms, are an emerging and effective technology that allows the replication of the function of tissues and organs, bridging the gap amid the conventional models based on planar cell cultures or animals and the complex human system. Hence, they have been increasingly used for biomedical research, such as drug discovery and personalized healthcare. A promising strategy for their fabrication is 3D printing, a layer-by-layer fabrication process that allows the construction of complex 3D structures. In contrast, 3D bioprinting, an evolving biofabrication method, focuses on the accurate deposition of hydrogel bioinks loaded with cells to construct tissue-engineered structures. The purpose of the present work is to conduct a systematic review (SR) of the published literature, according to the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses, providing a source of information on the evolution of organ-on-a-chip platforms obtained resorting to 3D printing and bioprinting techniques. In the literature search, PubMed, Scopus, and ScienceDirect databases were used, and two authors independently performed the search, study selection, and data extraction. The goal of this SR is to highlight the importance and advantages of using 3D printing techniques in obtaining organ-on-a-chip platforms, and also to identify potential gaps and future perspectives in this research field. Additionally, challenges in integrating sensors in organs-on-chip platforms are briefly investigated and discussed.


Assuntos
Bioimpressão , Dispositivos Lab-On-A-Chip , Animais , Humanos , Hidrogéis , Impressão Tridimensional , Engenharia Tecidual
18.
Nanomaterials (Basel) ; 11(5)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33921993

RESUMO

The combination of diagnostics and therapy (theranostic) is one of the most complex, yet promising strategies envisioned for nanoengineered multifunctional systems in nanomedicine. From the various multimodal nanosystems proposed, a number of works have established the potential of Graphene-based Magnetic Nanoparticles (GbMNPs) as theranostic platforms. This magnetic nanosystem combines the excellent magnetic performance of magnetic nanoparticles with the unique properties of graphene-based materials, such as large surface area for functionalization, high charge carrier mobility and high chemical and thermal stability. This hybrid nanosystems aims toward a synergistic theranostic effect. Here, we focus on the most recent developments in GbMNPs for theranostic applications. Particular attention is given to the synergistic effect of these composites, as well as to the limitations and possible future directions towards a potential clinical application.

19.
J Funct Biomater ; 13(1)2021 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-35076525

RESUMO

Polydimethylsiloxane (PDMS) is an elastomer with excellent optical, electrical and mechanical properties, which makes it well-suited for several engineering applications. Due to its biocompatibility, PDMS is widely used for biomedical purposes. This widespread use has also led to the massification of the soft-lithography technique, introduced for facilitating the rapid prototyping of micro and nanostructures using elastomeric materials, most notably PDMS. This technique has allowed advances in microfluidic, electronic and biomedical fields. In this review, an overview of the properties of PDMS and some of its commonly used treatments, aiming at the suitability to those fields' needs, are presented. Applications such as microchips in the biomedical field, replication of cardiovascular flow and medical implants are also reviewed.

20.
Foods ; 11(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35010210

RESUMO

The agri-food industry has historically determined the socioeconomic characteristics of Galicia and Northern Portugal, and it was recently identified as an area for collaboration in the Euroregion. In particular, there is a need for action to help to ensure the provision of safe and healthy foods by taking advantage of key enabling technologies. The goals of the FOODSENS project are aligned with this major objective, specifically with the development of biosensors able to monitor hazards relevant to the safety of food produced in the Euroregion. The present review addresses the state of the art of analytical methodologies and techniques-whether commercially available or in various stages of development-for monitoring food hazards, such as harmful algal blooms, mycotoxins, Listeria monocytogenes, allergens, and polycyclic aromatic hydrocarbons. We discuss the pros and cons of these methodologies and techniques and address lines of research for point-of-care detection. Accordingly, the development of miniaturized automated monitoring strategies is considered a priority in terms of health and economic interest, with a significant impact in several areas, such as food safety, water quality, pollution control, and public health. Finally, we present potential market opportunities that could result from the availability of rapid and reliable commercial methodologies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA