Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Control Release ; 214: 1-11, 2015 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-26160303

RESUMO

In this study we present the development of an injectable polymeric drug delivery system for subconjunctival treatment of primary open angle glaucoma. The system consists of hyaluronic acid sodium salt (HA), which is commonly used in ophthalmology in anterior segment surgery, and an isocyanate-functionalized 1,2-ethylene glycol bis(dilactic acid) (ELA-NCO). The polymer mixtures with different ratios of HA to ELA-NCO (1/1, 1/4, and 1/10 (v/v)) were investigated for biocompatibility, degradation behavior and applicability as a sustained release system. For the latter, the lipophilic latanoprost ester pro-drug (LA) was incorporated into the HA/ELA-NCO system. In vitro, a sustained LA release over a period of about 60days was achieved. In cell culture experiments, the HA/ELA-NCO (1/1, (v/v)) system was proven to be biocompatible for human and rabbit Tenon's fibroblasts. Examination of in vitro degradation behavior revealed a total mass loss of more than 60% during the observation period of 26weeks. In vivo, LA was continuously released for 152days into rabbit aqueous humor and serum. Histological investigations revealed a marked leuko-lymphocytic infiltration soon after subconjunctival injection. Thereafter, the initial tissue reaction declined concomitantly with a continuous degradation of the polymer, which was completed after 10months. Our study demonstrates the suitability of the polymer resulting from the reaction of HA with ELA-NCO as an injectable local drug delivery system for glaucoma therapy, combining biocompatibility and biodegradability with prolonged drug release.


Assuntos
Túnica Conjuntiva , Glaucoma de Ângulo Aberto/tratamento farmacológico , Animais , Humor Aquoso/metabolismo , Materiais Biocompatíveis , Células Cultivadas , Preparações de Ação Retardada , Portadores de Fármacos , Sistemas de Liberação de Medicamentos , Olho/patologia , Glaucoma de Ângulo Aberto/patologia , Humanos , Ácido Hialurônico/administração & dosagem , Ácido Hialurônico/uso terapêutico , Injeções , Latanoprosta , Fármacos Neuroprotetores/administração & dosagem , Fármacos Neuroprotetores/uso terapêutico , Polímeros , Pró-Fármacos/administração & dosagem , Prostaglandinas F Sintéticas/administração & dosagem , Prostaglandinas F Sintéticas/uso terapêutico , Coelhos
2.
PLoS One ; 10(3): e0116080, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25734818

RESUMO

Drug-coated balloons (DCB), which have emerged as a therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficacy and safety within a number of clinical studies. In vitro studies elucidating the correlation between coating additive and DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this regard, we examined three different DCB-systems, which were developed in former studies based on the ionic liquid cetylpyridinium salicylate, the body-own hydrogel hyaluronic acid and the pharmaceutically well-established hydrogel polyvinylpyrrolidone, considering coating morphology, coating thickness, drug-loss, drug-transfer to the vessel wall, residual drug-concentration on the balloon surface and entire drug-load during simulated use in an in vitro vessel model. Moreover, we investigated particle release of the different DCB during simulated use and determined the influence of the three coatings on the mechanical behavior of the balloon catheter. We could show that coating characteristics can be indeed correlated with the performance of DCB. For instance, paclitaxel incorporation in the matrix can reduce the drug wash-off and benefit a high drug transfer. Additionally, a thin coating with a smooth surface and high but delayed solubility can reduce drug wash-off and decrease particle burden. As a result, we suggest that it is very important to characterize DCB in terms of mentioned properties in vitro in addition to their clinical efficacy in order to better understand their function and provide more data for the clinicians to improve the tool of DCB in coronary angioplasty.


Assuntos
Antineoplásicos Fitogênicos/química , Materiais Revestidos Biocompatíveis/química , Stents Farmacológicos , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Líquidos Iônicos/química , Paclitaxel/química , Angioplastia Coronária com Balão , Materiais Revestidos Biocompatíveis/síntese química , Ácido Hialurônico/química , Líquidos Iônicos/síntese química , Microscopia Confocal , Microscopia Eletrônica de Varredura , Modelos Biológicos , Povidona/química , Propriedades de Superfície
3.
Mater Sci Eng C Mater Biol Appl ; 33(7): 4244-50, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23910339

RESUMO

Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer.


Assuntos
Angioplastia com Balão , Cateterismo , Cetilpiridínio/química , Cetilpiridínio/síntese química , Materiais Revestidos Biocompatíveis/síntese química , Modelos Teóricos , Paclitaxel/farmacologia , Materiais Revestidos Biocompatíveis/química , Simulação por Computador , Humanos , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA