1.
Radiother Oncol ; 197: 110366, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38830537

RESUMO

As a component of myeloablative conditioning before allogeneic hematopoietic stem cell transplantation (HSCT), Total Body Irradiation (TBI) is employed in radiotherapy centers all over the world. In recent and coming years, many centers are changing their technical setup from a conventional TBI technique to multi-isocenter conformal arc therapy techniques such as Volumetric Modulated Arc Therapy (VMAT) or Helical Tomotherapy (HT). These techniques allow better homogeneity and control of the target prescription dose, and provide more freedom for individualized organ-at-risk sparing. The technical design of multi-isocenter/multi-plan conformal TBI is complex and should be developed carefully. A group of early adopters with conformal TBI experience using different treatment machines and treatment planning systems came together to develop technical recommendations and share experiences, in order to assist departments wishing to implement conformal TBI, and to provide ideas for standardization of practices.

2.
Br J Radiol ; 96(1144): 20220650, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36475820

RESUMO

The use of volumetric arc therapy and inverse planning has been in routine use in radiotherapy for two decades. However, use in total body irradiation (TBI) has been more recent and few guidelines exist as to how to plan or verify. This has led to heterogeneous approaches. The goal of this review is to provide an overview of current advanced planning and dosimetry verification protocols used in optimised conformal TBI as a basis for investigating the need for greater standardisation in TBI.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Irradiação Corporal Total/métodos
3.
J Appl Clin Med Phys ; 23(12): e13798, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36453139

RESUMO

A hybrid quality control (QC) program was developed that integrates automated and conventional Linac QC, realizing the benefits of both automated and conventional QC, increasing efficiency and maintaining independent measurement methods. Failure mode and effects analysis (FMEA) was then applied in order to validate the program prior to clinical implementation. The hybrid QC program consists of automated QC with machine performance check and DailyQA3 array on the TrueBeam Linac, and Delta4 volumetric modulated arc therapy (VMAT) standard plan measurements, alongside conventional monthly QC at a reduced frequency. The FMEA followed the method outlined in TG-100. Process maps were created for each treatment type at our center: VMAT, stereotactic body radiotherapy (SBRT), conformal, and palliative. Possible failure modes were established by evaluating each stage in the process map. The FMEA followed semiquantitative methods, using data from our QC records from eight Linacs over 3 years for the occurrence estimates, and simulation of failure modes in the treatment planning system, with scoring surveys for severity and detectability. The risk priority number (RPN) was calculated from the product of the occurrence, severity, and detectability scores and then normalized to the maximum and ranked to determine the most critical failure modes. The highest normalized RPN values (100, 90) were found to be for MLC position dynamic for both VMAT and SBRT treatments. The next highest score was 35 for beam position for SBRT, and the majority of scores were less than 20. Overall, these RPN scores for the hybrid Linac QC program indicated that it would be acceptable, but the high RPN score associated with the dynamic MLC failure mode indicates that it would be valuable to perform more rigorous testing of the MLC. The FMEA proved to be a useful tool in validating hybrid QC.


Assuntos
Análise do Modo e do Efeito de Falhas na Assistência à Saúde , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Controle de Qualidade , Fatores de Risco , Simulação por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
4.
BJR Open ; 1(1): 20190008, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-33178940

RESUMO

OBJECTIVE: This paper reports on the rationalization of a substantial pool of in vivo dosimetry (IVD) data from patients treated with total skin electron beam therapy (TSEBT) and the application of this to verify the accurate delivery of TSEBT when changing linac manufacturer. METHODS: Thermoluminescent dosimeter IVD data from 149 patients were analyzed comparing the population mean and standard deviation for each site. The number of sites required to confirm the prescribed dose were reviewed considering both dosimetric and clinical relevance. The reduced sites were then used to assess the continued dosimetric accuracy on new equipment and the results were compared statistically using the Mann-Witney test. RESULTS: The trunk dose measurement points were reduced from nine to six and five extra trunk sites were identified and reviewed clinically prior to removal.Following change in manufacturer the trunk dose points showed no statistically significant change and confirmed that patients had received within 1.3% of the intended mean trunk dose using both delivery methods.A statistically significant change in 4 out of the 13 extra trunk sites was seen following the move to the new centre. However, all but one site showed a change of less than 1 standard deviation. CONCLUSION: The total number of measurement points per patient were reduced from 27 to 19 which constituted a 25% saving in preparation and read out.Accurate delivery of prescribed dose was confirmed following measurement point reduction for treatments delivered on linacs from two different manufacturers. ADVANCES IN KNOWLEDGE: Proven methodology for rationalization of IVD measurements for TSEBT.