Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Biology (Basel) ; 11(12)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36552235

RESUMO

Sexual dimorphism in the human dentition is of interest from a developmental, evolutionary, and clinical point of view. Here, we investigated sexual dimorphism in third molar agenesis patterns and severity in non-syndromic white European individuals with (group A: 303 individuals) and without agenesis (group B: 303 individuals) of teeth other than the third molars. There was no sexual dimorphism in the patterns or the severity of third molar agenesis within groups. Both sexes showed a higher number of third molar agenesis per individual in group A than in group B. The most common third molar agenesis pattern was that of no third molars. For both females and males, bilateral third molar agenesis was approximately three times more frequent in group A than in group B (p < 0.001), whereas no difference was detected for unilateral agenesis. These findings indicate a strong genetic control of the developmental process of tooth formation, with any disruptions affecting both sexes in a similar manner. Overall, the higher vulnerability of third molar formation could be associated with the evolutionary trend in humans towards a reduced number of molar teeth, which seems to show no sex-related differences.

2.
Eur J Orthod ; 38(5): 447-58, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26359019

RESUMO

OBJECTIVES: To assess the available evidence on the effectiveness of lingual orthodontic treatment and related clinical parameters through a systematic review of relevant studies. MATERIALS AND METHODS: Eligible clinical studies published from January 2000 to March 2015 were identified through electronic (five major databases) and hand searches. Risk of bias was assessed using the Cochrane risk of bias tool for prospective studies and a specially designed tool for retrospective studies. RESULTS: From the 3734 articles identified by the search, after application of specific inclusion and exclusion criteria, 16 papers were included in the study. Eleven studies were retrospective, four were prospective, and only one was a RCT. In detail, six studies evaluated differences of the treatment outcome from the pre-treatment set-up prediction, two studies evaluated the effect of treatment on periodontal and microbial parameters, and 10 studies assessed various clinical treatment related parameters. Despite several promising findings, the quality of evidence supporting them was found to be low in most cases. CONCLUSIONS: This systematic review showed encouraging results on the clinical outcome of lingual orthodontic treatment, especially in regards to the achievement of individualized treatment goals and the reduction of decalcifications on the bonded surfaces of the teeth. However, additional well-designed prospective clinical trials with larger samples are needed to confirm those findings. Several aspects of lingual orthodontic treatment were difficult to be conclusively evaluated due to the study design, the heterogeneity, the small samples sizes, and the high risk of bias seen in the majority of the included studies.


Assuntos
Má Oclusão/terapia , Técnicas de Movimentação Dentária/métodos , Viés , Humanos , Braquetes Ortodônticos , Estudos Prospectivos , Estudos Retrospectivos , Língua , Resultado do Tratamento
3.
J Dent ; 42(10): 1300-19, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25072362

RESUMO

OBJECTIVES: To assess the available evidence on the effectiveness of accelerated orthodontic tooth movement through surgical and non-surgical approaches in orthodontic patients. METHODS: Randomized controlled trials and controlled clinical trials were identified through electronic and hand searches (last update: March 2014). Orthognathic surgery, distraction osteogenesis, and pharmacological approaches were excluded. Risk of bias was assessed using the Cochrane risk of bias tool. RESULTS: Eighteen trials involving 354 participants were included for qualitative and quantitative synthesis. Eight trials reported on low-intensity laser, one on photobiomodulation, one on pulsed electromagnetic fields, seven on corticotomy, and one on interseptal bone reduction. Two studies on corticotomy and two on low-intensity laser, which had low or unclear risk of bias, were mathematically combined using the random effects model. Higher canine retraction rate was evident with corticotomy during the first month of therapy (WMD=0.73; 95% CI: 0.28, 1.19, p<0.01) and with low-intensity laser (WMD=0.42mm/month; 95% CI: 0.26, 0.57, p<0.001) in a period longer than 3 months. The quality of evidence supporting the interventions is moderate for laser therapy and low for corticotomy intervention. CONCLUSIONS: There is some evidence that low laser therapy and corticotomy are effective, whereas the evidence is weak for interseptal bone reduction and very weak for photobiomodulation and pulsed electromagnetic fields. Overall, the results should be interpreted with caution given the small number, quality, and heterogeneity of the included studies. Further research is required in this field with additional attention to application protocols, adverse effects, and cost-benefit analysis. CLINICAL SIGNIFICANCE: From the qualitative and quantitative synthesis of the studies, it could be concluded that there is some evidence that low laser therapy and corticotomy are associated with accelerated orthodontic tooth movement, while further investigation is required before routine application.


Assuntos
Técnicas de Movimentação Dentária/métodos , Humanos , Terapia com Luz de Baixa Intensidade/métodos , Magnetoterapia/métodos , Osteotomia/métodos , Fatores de Tempo
4.
J Appl Oral Sci ; 21(2): 138-44, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23739854

RESUMO

UNLABELLED: Crown discoloration can be induced by root canal sealer remnants following root canal treatment. OBJECTIVE: The aim of this study was to evaluate chromatic alterations in human tooth crowns induced by a Mineral Trioxide Aggregate-based sealer (MTA Fillapex®) and a commonly used ZnOE-based sealer (Roth-811). The tested null hypothesis was that the application of the materials did not induce clinically perceptible crown discoloration (Ho: CIE color difference ΔE<3.7). MATERIAL AND METHODS: Forty five fully developed, intact, mandibular third molars were sectioned 1 mm below the cemento-enamel junction. The pulp chambers were chemomechanically debrided via the cervical access. The specimens were randomly assigned into three groups Group 1: MTA Fillapex, Group 2: Roth 811, Group 3: Negative control (unfilled) and immersed in individually marked vials containing distilled water up to the cervix (37±1°C). The spectral reflectance lines were recorded by utilizing a UV-VIS spectrophotometer equipped with integration sphere in the visual spectrum at baseline, 1 week, 1 and 3 months after material placement. Data were transformed into values of the CIE L*a*b* color system and the corresponding ΔE values were calculated. Statistical analysis was performed using two-way mixed ANOVA models, at p=0.05 level of significance. RESULTS: A statistically significant increase in a* and b* chromatic parameters of the MTA Fillapex Group was measured. However, ΔE values did not exceed the human eye perceptibility threshold (set at ΔE<3.7) during the experimental period (ΔEt3=2.88). In Roth-811 Group, a statistically significant decrease in L* and a statistically significant increase in a* and b* chromatic parameters was measured, during all observation periods. Resultant ΔE values exceeded the human eye perceptibility threshold after 1 week (ΔEt1=5.65). CONCLUSIONS: Application of MTA Fillapex in tooth crowns resulted in minimal color alterations, while Roth 811 induced severe discoloration, in vitro. It could be suggested that, in terms of aesthetics, the use of MTA Fillapex appears to be favorable.


Assuntos
Compostos de Alumínio/química , Compostos de Cálcio/química , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Coroa do Dente/efeitos dos fármacos , Descoloração de Dente/induzido quimicamente , Cimento de Óxido de Zinco e Eugenol/química , Compostos de Alumínio/efeitos adversos , Análise de Variância , Compostos de Cálcio/efeitos adversos , Cor , Combinação de Medicamentos , Humanos , Teste de Materiais , Óxidos/efeitos adversos , Valores de Referência , Materiais Restauradores do Canal Radicular/efeitos adversos , Silicatos/efeitos adversos , Espectrofotometria Ultravioleta , Fatores de Tempo , Coroa do Dente/química , Cimento de Óxido de Zinco e Eugenol/efeitos adversos
5.
J. appl. oral sci ; 21(2): 138-144, Mar-Apr/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-674358

RESUMO

Crown discoloration can be induced by root canal sealer remnants following root canal treatment. Objective: The aim of this study was to evaluate chromatic alterations in human tooth crowns induced by a Mineral Trioxide Aggregate-based sealer (MTA Fillapex®) and a commonly used ZnOE-based sealer (Roth-811). The tested null hypothesis was that the application of the materials did not induce clinically perceptible crown discoloration (Ho: CIE color difference ΔE<3.7). Material and Methods: Forty five fully developed, intact, mandibular third molars were sectioned 1 mm below the cemento-enamel junction. The pulp chambers were chemomechanically debrided via the cervical access. The specimens were randomly assigned into three groups Group 1: MTA Fillapex, Group 2: Roth 811, Group 3: Negative control (unfilled) and immersed in individually marked vials containing distilled water up to the cervix (37±1°C). The spectral reflectance lines were recorded by utilizing a UV-VIS spectrophotometer equipped with integration sphere in the visual spectrum at baseline, 1 week, 1 and 3 months after material placement. Data were transformed into values of the CIE L*a*b* color system and the corresponding ΔE values were calculated. Statistical analysis was performed using two-way mixed ANOVA models, at p=0.05 level of significance. Results: A statistically significant increase in a* and b* chromatic parameters of the MTA Fillapex Group was measured. However, ΔE values did not exceed the human eye perceptibility threshold (set at ΔE<3.7) during the experimental period (ΔEt3=2.88). In Roth-811 Group, a statistically significant decrease in L* and a statistically significant increase in a* and b* chromatic parameters was measured, during all observation periods. Resultant ΔE values exceeded the human eye perceptibility threshold after 1 week (ΔEt1=5.65). Conclusions: Application of MTA Fillapex in tooth crowns resulted in minimal color alterations, while Roth 811 induced severe discoloration, in vitro. It could be suggested that, in terms of aesthetics, the use of MTA Fillapex appears to be favorable.


Assuntos
Humanos , Compostos de Alumínio/química , Compostos de Cálcio/química , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Coroa do Dente/efeitos dos fármacos , Descoloração de Dente/induzido quimicamente , Cimento de Óxido de Zinco e Eugenol/química , Análise de Variância , Compostos de Alumínio/efeitos adversos , Cor , Compostos de Cálcio/efeitos adversos , Combinação de Medicamentos , Teste de Materiais , Óxidos/efeitos adversos , Valores de Referência , Materiais Restauradores do Canal Radicular/efeitos adversos , Espectrofotometria Ultravioleta , Silicatos/efeitos adversos , Fatores de Tempo , Coroa do Dente/química , Cimento de Óxido de Zinco e Eugenol/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA