Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Klin Monbl Augenheilkd ; 190(3): 217-8, 1987 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-3586547

RESUMO

This paper is a report from the First Symposium on Video Fluorescein Angiography, held on November 29, 1985, at the Charlottenburg Eye Clinic of the Free University of Berlin. Following a discussion among the working groups from Aachen, Tübingen, and Berlin, N. Körber (Cologne), V. Miszalok (Berlin), F. Jung (Homburg), and S. Wolf (Aachen) propose a new, uniform set of definitions relating to time and velocity measurable with video techniques.


Assuntos
Angiofluoresceinografia/métodos , Terminologia como Assunto , Gravação de Videoteipe/métodos , Humanos
3.
Can J Cardiol ; Suppl A: 25A-31A, 1986 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3756593

RESUMO

Two-dimensional echocardiography allows identification of myocardial perfusion defects due to coronary artery occlusion by detection of regional wall motion abnormalities and absence of myocardial echocontrast enhancement after injection of echocontrast agents into the aortic root. In the current study twelve anesthetized closed chest dogs were examined before and after balloon occlusion of a coronary vessel. Size of perfusion defects was determined morphologically by Evans blue staining, while the circumferential extent of regional wall motion abnormality was calculated using radial wall motion analysis of the two-dimensional echocardiogram. Four mL of SH U 454 were injected into the aortic root for echocontrast studies. Perfusion defects in the echocardiogram were determined planimetrically in the analog two-dimensional echocardiographic image. In addition, perfusion defects in the contrast echocardiogram were estimated by a digital image processing technique along a circumferential mid-wall line. Along this line the time-intensity curves of the myocardial echocontrast were also calculated. There was a linear correlation between morphological determination of perfusion defects and their planimetric estimate in the contrast echocardiogram. The linear regression equation was y = 0.98x + 4.63, r = 0.92, and the standard error of estimate for the echocardiographic examination was SEE = 4.4%. Digital image processing did not increase accuracy in determining the size of perfusion defects (r = 0.88; y = 1.01x + 3.33; SEE = 5.7%). By comparing the extent of regional wall motion abnormalities with the size of anatomic perfusion defects there was a correlation of r = 0.85; SEE = 6.2%; y = 0.71x + 10.50.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Circulação Coronária , Doença das Coronárias/fisiopatologia , Ecocardiografia , Animais , Meios de Contraste , Diástole , Cães , Contração Miocárdica , Polissacarídeos , Sístole
4.
Ultrasound Med Biol ; 12(7): 581-6, 1986 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3750554

RESUMO

The position and size of experimental myocardial perfusion defects can be detected by using the echocardiographic contrast-medium Echoson together with digital image processing techniques. Video tapes showing the important sequences before, during and after cardial inflow of echo-enhancing agents are fed in total length into a digital image processing unit. The myocardial circumferences are then chosen interactively. All the frames are analysed and a synthetic picture is compiled, and shows the myocardial echo densities in a single, highly condensed form. Digital subtraction of blank values (condensed sequences before injection of contrast medium) greatly improves readability. Further concentration of the remaining information yields the following diagrams: flow/circumferential position (time summation); flow/time (position summation), which contain the desired information on homogeneity or defects of echo density against time and myocardial position.


Assuntos
Circulação Coronária , Ecocardiografia/métodos , Animais , Computadores , Meios de Contraste , Cães , Aumento da Imagem , Fatores de Tempo , Gravação de Videoteipe
5.
Ophthalmologica ; 193(4): 231-5, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3295637

RESUMO

SH U 454 is a new echocontrast agent which was developed primarily for echocardiography. It seems that there is a further potential in ophthalmic ultrasound diagnostics. SH U 454 produces contrast enhancement in the orbit, choroid and ciliary body, and permits determination of intraocular blood flow parameters in dogs' eyes. The effects are measured with digital picture processing techniques.


Assuntos
Meios de Contraste , Olho/anatomia & histologia , Órbita/anatomia & histologia , Polissacarídeos , Ultrassonografia , Animais , Corioide/anatomia & histologia , Corpo Ciliar/anatomia & histologia , Cães , Retina/irrigação sanguínea
6.
Ophthalmologica ; 192(1): 49-55, 1986.
Artigo em Alemão | MEDLINE | ID: mdl-3703479

RESUMO

The NMR relaxation data of tissue are the basis of an appropriate adjustment of NMR imaging parameters. The relaxation data of ocular tissues are presented, and the relaxation behaviour of the eye is discussed. NMR imaging of eyes with intraocular silicone and pseudophakia are shown. Up to the present time, neuritis of the optic nerve is not detectable by NMR tomography whereas intraocular melanoma are clearly distinguishable.


Assuntos
Oftalmopatias/patologia , Olho/patologia , Espectroscopia de Ressonância Magnética , Neoplasias Oculares/patologia , Humanos , Cristalino/patologia , Lentes Intraoculares , Melanoma/patologia , Atrofia Óptica/patologia , Nervo Óptico/patologia , Neurite Óptica/patologia , Complicações Pós-Operatórias/patologia , Vitrectomia , Corpo Vítreo/patologia
9.
Ophthalmologica ; 190(1): 7-19, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-3969263

RESUMO

The proposed method allows to discover and quantify small changes in series of fundus photographs which are normally not directly comparable. The principle of geometric conformality of small parts between the fundus and its photographs is developed into a practical method of stereoscopic measurement, numerical adjustment and quantitative evaluation. Very high accuracy is possible without special conditions on repeated fundus photography. The aim is to create a theoretical and methodical basis for ophthalmoscopic change detection with image-processing computers.


Assuntos
Fundo de Olho , Monitorização Fisiológica/métodos , Matemática , Fotografação
10.
Klin Monbl Augenheilkd ; 185(4): 279-81, 1984 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-6513400

RESUMO

We present two further cases of choroiditis geographica. One of them we were able to follow up for two years. This allowed us to observe from the beginning the eye which was not at first involved. Weeks before the first lesions were visible, alterations of the EOG appeared. In the other case both eyes were already involved at the time of first presentation to our hospital. The more involved eye had shown typical degeneration as long as 19 years ago, and we found a proliferation of glia at the macula. We propose a systemic therapy with corticosteroids.


Assuntos
Corioidite/diagnóstico , Adulto , Coriorretinite/diagnóstico , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Acuidade Visual , Campos Visuais
12.
Klin Monbl Augenheilkd ; 184(4): 308-10, 1984 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-6727261

RESUMO

A method has been developed for measuring intraocular pressure continuously. By comparing the results with theoretical models it has been established that only viscoelasticity of the sclera and cornea is able to compensate for rapid pressure fluctuations, whereas facility does this only to a minor degree.


Assuntos
Tonometria Ocular , Animais , Humanos , Pressão Intraocular , Matemática , Modelos Teóricos , Coelhos , Tonometria Ocular/instrumentação
14.
Klin Monbl Augenheilkd ; 183(4): 278-81, 1983 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-6645272

RESUMO

Two cases of geographic choroiditis are reported. This disease is characterized by multiple confluent lesions of the pigment epithelium and the choriocapillaris leading to scars. During the initial episodes geographic choroiditis may look like APMPP but the prognosis is worse. A remarkable depression of the EOG was observed in an apparently unaffected corresponding eye. The etiology of this disease is so far unknown.


Assuntos
Corioidite/diagnóstico , Adulto , Capilares/patologia , Corioide/irrigação sanguínea , Diagnóstico Diferencial , Eletroculografia , Feminino , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Epitélio Pigmentado Ocular/patologia , Prognóstico
16.
Ophthalmologica ; 184(4): 181-9, 1982.
Artigo em Alemão | MEDLINE | ID: mdl-7070761

RESUMO

A method for transformation of photographic transparencies into three-dimensional relief pictures is presented. Black-and-white or color slides of fundi were scanned by a TV camera, the video signals digitized point by point into 256 gray levels and fed into an image processing computer. After passing low pass filter programs, the pictures were retransformed in an analog form to display them on the monitor of an analog processor in relief form. Free choice of the analog relief parameters allow to produce topographic reliefs, which give three-dimensional impression of the optic disk, the macula and of other contrast-containing structures. The method is peculiarly suitable for the control of optic disk atrophies in case of glaucoma and neuritis.


Assuntos
Angiofluoresceinografia/instrumentação , Oftalmoscópios , Conversão Análogo-Digital , Glaucoma/diagnóstico , Humanos , Disco Óptico/anatomia & histologia , Neurite Óptica/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA