Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Struct Mol Biol ; 30(6): 812-823, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37202477

RESUMO

Accurate replication of mitochondrial DNA (mtDNA) by DNA polymerase γ (Polγ) is essential for maintaining cellular energy supplies, metabolism, and cell cycle control. To illustrate the structural mechanism for Polγ coordinating polymerase (pol) and exonuclease (exo) activities to ensure rapid and accurate DNA synthesis, we determined four cryo-EM structures of Polγ captured after accurate or erroneous incorporation to a resolution of 2.4-3.0 Å. The structures show that Polγ employs a dual-checkpoint mechanism to sense nucleotide misincorporation and initiate proofreading. The transition from replication to error editing is accompanied by increased dynamics in both DNA and enzyme, in which the polymerase relaxes its processivity and the primer-template DNA unwinds, rotates, and backtracks to shuttle the mismatch-containing primer terminus 32 Å to the exo site for editing. Our structural and functional studies also provide a foundation for analyses of Polγ mutation-induced human diseases and aging.


Assuntos
DNA Polimerase Dirigida por DNA , Genoma Mitocondrial , Humanos , DNA Polimerase Dirigida por DNA/química , Replicação do DNA , DNA Polimerase gama/genética , DNA Polimerase gama/metabolismo , DNA Mitocondrial/genética
2.
Nat Commun ; 14(1): 692, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36754966

RESUMO

Huntington's disease (HD) is caused by an expanded CAG repeat in the huntingtin gene, yielding a Huntingtin protein with an expanded polyglutamine tract. While experiments with patient-derived induced pluripotent stem cells (iPSCs) can help understand disease, defining pathological biomarkers remains challenging. Here, we used cryogenic electron tomography to visualize neurites in HD patient iPSC-derived neurons with varying CAG repeats, and primary cortical neurons from BACHD, deltaN17-BACHD, and wild-type mice. In HD models, we discovered sheet aggregates in double membrane-bound organelles, and mitochondria with distorted cristae and enlarged granules, likely mitochondrial RNA granules. We used artificial intelligence to quantify mitochondrial granules, and proteomics experiments reveal differential protein content in isolated HD mitochondria. Knockdown of Protein Inhibitor of Activated STAT1 ameliorated aberrant phenotypes in iPSC- and BACHD neurons. We show that integrated ultrastructural and proteomic approaches may uncover early HD phenotypes to accelerate diagnostics and the development of targeted therapeutics for HD.


Assuntos
Doença de Huntington , Células-Tronco Pluripotentes Induzidas , Animais , Camundongos , Inteligência Artificial , Modelos Animais de Doenças , Proteína Huntingtina/genética , Proteína Huntingtina/metabolismo , Doença de Huntington/metabolismo , Células-Tronco Pluripotentes Induzidas/metabolismo , Mitocôndrias/metabolismo , Neurônios/metabolismo , Fenótipo , Proteômica , Humanos
4.
Ultramicroscopy ; 232: 113417, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34695647

RESUMO

Electron crystallography has recently gained attentions in multiple fields of research, as it has been demonstrated to determine atomic structures for inorganic, organic, and macromolecular materials from nano-sized crystals that were not amenable to conventional X-ray crystallography. Here, we demonstrate continuous-rotation microcrystal electron diffraction (microED) in a 200 kV transmission electron microscope using a DE-64 camera-a low-noise direct electron detector that can accommodate a linear response up to ∼1200 electrons per pixel per second at 20 fps with 2x-hardware-binning, making it ideal for acquisition of high-quality diffraction patterns. We have used this method and camera to determine a 0.75 Å structure of an organic molecule, biotin, with an exceptional goodness-of-fit, as well as a 0.88 Å structure of a chiral molecule, L-serine.


Assuntos
Elétrons , Cristalografia , Cristalografia por Raios X , Substâncias Macromoleculares , Modelos Moleculares
5.
NPJ Breast Cancer ; 6: 42, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32964116

RESUMO

Migration and invasion are key properties of metastatic cancer cells. These properties can be acquired through intrinsic reprogramming processes such as epithelial-mesenchymal transition. In this study, we discovered an alternative "migration-by-tethering" mechanism through which cancer cells gain the momentum to migrate by adhering to mesenchymal stem cells or osteoblasts. This tethering is mediated by both heterotypic adherens junctions and gap junctions, and leads to a unique cellular protrusion supported by cofilin-coated actin filaments. Inhibition of gap junctions or depletion of cofilin reduces migration-by-tethering. We observed evidence of these protrusions in bone segments harboring experimental and spontaneous bone metastasis in animal models. These data exemplify how cancer cells may acquire migratory ability without intrinsic reprogramming. Furthermore, given the important roles of osteogenic cells in early-stage bone colonization, our observations raise the possibility that migration-by-tethering may drive the relocation of disseminated tumor cells between different niches in the bone microenvironment.

6.
Structure ; 28(11): 1231-1237.e3, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-32814034

RESUMO

Three-dimensional (3D) visualization of vitrified cells can uncover structures of subcellular complexes without chemical fixation or staining. Here, we present a pipeline integrating three imaging modalities to visualize the same specimen at cryogenic temperature at different scales: cryo-fluorescence confocal microscopy, volume cryo-focused ion beam scanning electron microscopy, and transmission cryo-electron tomography. Our proof-of-concept benchmark revealed the 3D distribution of organelles and subcellular structures in whole heat-shocked yeast cells, including the ultrastructure of protein inclusions that recruit fluorescently-labeled chaperone Hsp104. Since our workflow efficiently integrates imaging at three different scales and can be applied to other types of cells, it could be used for large-scale phenotypic studies of frozen-hydrated specimens in a variety of healthy and diseased conditions with and without treatments.


Assuntos
Estruturas Citoplasmáticas/ultraestrutura , Imageamento Tridimensional/métodos , Saccharomyces cerevisiae/ultraestrutura , Biomarcadores/metabolismo , Microscopia Crioeletrônica , Estruturas Citoplasmáticas/metabolismo , Expressão Gênica , Genes Reporter , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Proteínas de Choque Térmico/genética , Proteínas de Choque Térmico/metabolismo , Imageamento Tridimensional/instrumentação , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/genética , Proteínas de Saccharomyces cerevisiae/metabolismo , Vitrificação
7.
Proc Natl Acad Sci U S A ; 117(25): 13937-13944, 2020 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-32513734

RESUMO

Superresolution fluorescence microscopy and cryogenic electron tomography (CET) are powerful imaging methods for exploring the subcellular organization of biomolecules. Superresolution fluorescence microscopy based on covalent labeling highlights specific proteins and has sufficient sensitivity to observe single fluorescent molecules, but the reconstructions lack detailed cellular context. CET has molecular-scale resolution but lacks specific and nonperturbative intracellular labeling techniques. Here, we describe an imaging scheme that correlates cryogenic single-molecule fluorescence localizations with CET reconstructions. Our approach achieves single-molecule localizations with an average lateral precision of 9 nm, and a relative registration error between the set of localizations and CET reconstruction of ∼30 nm. We illustrate the workflow by annotating the positions of three proteins in the bacterium Caulobacter crescentus: McpA, PopZ, and SpmX. McpA, which forms a part of the chemoreceptor array, acts as a validation structure by being visible under both imaging modalities. In contrast, PopZ and SpmX cannot be directly identified in CET. While not directly discernable, PopZ fills a region at the cell poles that is devoid of electron-dense ribosomes. We annotate the position of PopZ with single-molecule localizations and confirm its position within the ribosome excluded region. We further use the locations of PopZ to provide context for localizations of SpmX, a low-copy integral membrane protein sequestered by PopZ as part of a signaling pathway that leads to an asymmetric cell division. Our correlative approach reveals that SpmX localizes along one side of the cell pole and its extent closely matches that of the PopZ region.


Assuntos
Proteínas de Bactérias/metabolismo , Caulobacter crescentus/ultraestrutura , Imagem Individual de Molécula/métodos , Proteínas de Bactérias/ultraestrutura , Caulobacter crescentus/metabolismo , Tomografia com Microscopia Eletrônica/métodos , Microscopia de Fluorescência/métodos , Transporte Proteico
8.
Microsc Microanal ; 22(3): 487-96, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27225525

RESUMO

Although acknowledged to be variable and subjective, manual annotation of cryo-electron tomography data is commonly used to answer structural questions and to create a "ground truth" for evaluation of automated segmentation algorithms. Validation of such annotation is lacking, but is critical for understanding the reproducibility of manual annotations. Here, we used voxel-based similarity scores for a variety of specimens, ranging in complexity and segmented by several annotators, to quantify the variation among their annotations. In addition, we have identified procedures for merging annotations to reduce variability, thereby increasing the reliability of manual annotation. Based on our analyses, we find that it is necessary to combine multiple manual annotations to increase the confidence level for answering structural questions. We also make recommendations to guide algorithm development for automated annotation of features of interest.


Assuntos
Tomografia com Microscopia Eletrônica/métodos , Tomografia com Microscopia Eletrônica/normas , Algoritmos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA