Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Plast Reconstr Surg Glob Open ; 9(5): e3529, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34881139

RESUMO

Bioabsorbable meshes have seen increasing clinical use to reinforce soft tissue, and exist on a spectrum of strength loss versus absorption: several retain their strength for months, but remain in situ for years. Others lose strength fully by 6 weeks. An intermediate profile, with some strength for 3 -4 months, but consistent absorption in less than a year, may be an optimal balance of near-term support and long-term safety. In this large animal study, we evaluate such a mesh (DuraSorb, SIA), assessing its utility in a porcine model of abdominal wall repair. METHODS: Two full-thickness defects were created in the abdominal walls of nine Yucatan swine via midline approach and repaired preperitoneally with either DuraSorb or long-lasting control mesh (TIGR, Novus Scientific). At 30 days, 3 months, and 1 year, the implantations were assessed by clinical pathology, post-necropsy histopathology, and burst strength testing. RESULTS: No device-associated complications were found in vivo, at necropsy, or histologically. DuraSorb was well-integrated and vascularized by 30 days. DuraSorb demonstrated minimal/mild inflammation and fibroplasia, and lower inflammatory scores when compared with TIGR at all time points (P < 0.05). Burst strength of the repair sites was higher than adjacent abdominal wall at all time points (P < 0.05). CONCLUSIONS: DuraSorb provided durable long-term support, minimal inflammation, and consistent absorption in this porcine model of abdominal wall repair, as compared to a long-term control. Clinical data is needed, but these results suggest that this mesh provides adequate structural support while potentially reducing long-term device reactions.

2.
Am J Surg ; 216(2): 267-273, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29108644

RESUMO

BACKGROUND: We sought to evaluate the results of a new mesh sutured repair technique for closure of contaminated incisional hernias. METHODS: 48 patients with contaminated hernias 5 cm wide or greater by CT scan were closed with mesh sutures. Surgical site occurrence, infections, and hernia recurrence were compared to similar patient series reported in the literature. RESULTS: Of the 48 patients, 20 had clean-contaminated wounds, 16 had contaminated wounds, and 12 were infected. 69% of the patients underwent an anterior perforator sparing components release for hernias that averaged 10.5 cm transversely (range 5 cm-25 cm). SSO occurred in 27% of patients while SSI was 19%. There were no fistulas or delayed suture sinuses. With a mean follow-up of almost 12 months, 3 midline hernias recurred (6%). In these same patients, three parastomal hernias repaired with mesh sutures failed out of 4 attempted for a total failure rate of 13%. CONCLUSION: Mesh sutured closure represents a simplified and effective surgical strategy for contaminated midline incisional hernia repair.


Assuntos
Herniorrafia/métodos , Hérnia Incisional/cirurgia , Complicações Pós-Operatórias/epidemiologia , Telas Cirúrgicas , Técnicas de Sutura/instrumentação , Suturas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hérnia Incisional/diagnóstico , Masculino , Pessoa de Meia-Idade , Recidiva , Tomografia Computadorizada por Raios X , Adulto Jovem
3.
Plast Reconstr Surg Glob Open ; 6(12): e2065, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30656128

RESUMO

BACKGROUND: Despite growing use of surgical risk calculators, many are limited to 30-day outcomes due to the constraints of their underlying datasets. Because complications of breast reconstruction can occur well beyond 30 days after surgery, we endeavored to expand the Breast Reconstruction Risk Assessment (BRA) Score to prediction of 1-year complications after primary prosthetic breast reconstruction. METHODS: We examined our prospective intrainstitutional database of prosthetic breast reconstructions from 2004 to 2015. Patients without 1-year follow-up were excluded. Pertinent patient variables include those enumerated in past iterations of the BRA Score. Outcomes of interest include seroma, surgical site infection (SSI), implant exposure, and explantation occurring within 1 year of tissue expander placement. Risk calculators were developed for each outcome using multivariate logistic regression models and made available online at www.BRAScore.org. Internal validity was assessed using C-statistic, Hosmer-Lemeshow test, and Brier score. RESULTS: Nine-hundred three patients met inclusion criteria. Within 1-year, 3.0% of patients experienced seroma, 6.9% infection, 7.1% implant exposure, and 13.2% explantation. Thirty-day, 90-day, and 180-day windows captured 17.6%, 39.5%, and 59.7% of explantations, respectively. One-year risk calculators were developed for each complication of interest, and all demonstrated good internal validity: C-statistics for the 5 models ranged from 0.674 to 0.739, Hosmer-Lemeshow tests were uniformly nonsignificant, and Brier scores ranged from 0.027 to 0.154. CONCLUSIONS: Clinically significant complications of prosthetic breast reconstruction usually occur beyond the 30-day window following tissue expander placement. To better reflect long-term patient experiences, the BRA Score was enhanced with individualized risk models that predicted 1-year complications after prosthetic reconstruction (BRA Score XL). All models performed as well as, if not better than, the original BRA Score models and other popular risk calculators such as the CHA2DS2VASc Score. The patient-friendly BRA Score XL risk calculator is available at www.brascore.org to facilitate operative decision-making and heighten the informed consent process for patients.

4.
Plast Reconstr Surg ; 140(5S Advances in Breast Reconstruction): 30S-43S, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29064920

RESUMO

Of the nearly 90,000 implant-based breast reconstructions performed in the United States, the majority use internal soft-tissue support. Aesthetically, these constructs may allow for better positioning of prosthesis, improve lower pole expansion, and increase projection. They may have particular utility in direct-to-implant, nipple-sparing mastectomies, and prepectoral reconstructions. In recent years, new permutations of acellular dermal matrices have evolved with diverse shapes, sizes, form-factor innovations, and processing characteristics. The literature is largely limited to retrospective studies (and meta-analyses thereof), making robust comparisons of 1 iteration vis-à-vis another difficult. Although synthetic mesh may provide a cost-effective alternative in primary and secondary reconstruction, comparative studies with acellular dermal matrix are lacking. This review aims to provide a balanced overview of recent biologic and synthetic mesh innovation. As this technology (and concomitant techniques) evolve, the reconstructive surgeon is afforded more-and better-choices to improve care for patients.


Assuntos
Derme Acelular , Neoplasias da Mama/cirurgia , Mamoplastia/métodos , Transplante de Pele/métodos , Telas Cirúrgicas , Alicerces Teciduais , Feminino , Humanos
5.
J Plast Reconstr Aesthet Surg ; 70(7): 876-883, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28539245

RESUMO

INTRODUCTION: The Breast reconstruction Risk Assessment (BRA) Score estimates patient-specific risk for postsurgical complications using an individual's unique combination of preoperative variables. In this report, we externally validate the BRA Score models for surgical site infection, seroma, and explantation in a large sample of intra-institutional patients who underwent prosthetic breast reconstruction. METHODS: We reviewed all initiated tissue expander/implant reconstructions by the senior authors from January 2004 to December 2015. BRA Score risk estimates were computed for each patient and compared against observed rates of complications. Hosmer-Lemeshow goodness-of-fit test, concordance statistic, and Brier score were used to assess the calibration, discrimination, and accuracy of the models, respectively. RESULTS: Of the 1152 patients (1743 breasts) reviewed, 855 patients (1333 breasts) had complete data for BRA-score calculations and were included for analysis. Hosmer-Lemeshow tests for calibration demonstrated a good agreement between observed and predicted outcomes for surgical site infection (SSI) and seroma models (P-values of 0.33 and 0.16, respectively). In contrast, predicted rates of explantation deviated from observed rates (Hosmer-Lemeshow P-value of 0.04). C statistics demonstrated good discrimination for SSI, seroma, and explantation (0.73, 0.69, and 0.78, respectively). CONCLUSIONS: In this external validation study, the BRA Score tissue expander/implant reconstruction models performed with generally good calibration, discrimination, and accuracy. Some weaknesses in certain models were identified as targets for future improvement. Taken together, these analyses validate the clinical utility of the BRA score risk models in predicting 30-day outcomes.


Assuntos
Remoção de Dispositivo , Mamoplastia/efeitos adversos , Modelos Estatísticos , Seroma/etiologia , Infecção da Ferida Cirúrgica/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Previsões , Humanos , Pessoa de Meia-Idade , Medição de Risco/métodos , Fatores de Risco , Adulto Jovem
6.
Aesthet Surg J ; 35(8): 999-1006, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26163312

RESUMO

BACKGROUND: Combined abdominal and breast surgery presents a convenient and relatively cost-effective approach for accomplishing both procedures. OBJECTIVES: This study is the largest to date assessing the safety of combined procedures, and it aims to develop a simple pretreatment risk stratification method for patients who desire a combined procedure. METHODS: All women undergoing abdominoplasty, panniculectomy, augmentation mammaplasty, and/or mastopexy in the TOPS database were identified. Demographics and outcomes for combined procedures were compared to individual procedures using χ(2) and Student's t-tests. Multiple logistic regression provided adjusted odds ratios for the effect of a combined procedure on 30-day complications. Among combined procedures, a logistic regression model determined point values for pretreatment risk factors including diabetes (1 point), age over 53 (1), obesity (2), and 3+ ASA status (3), creating a 7-point pretreatment risk stratification tool. RESULTS: A total of 58,756 cases met inclusion criteria. Complication rates among combined procedures (9.40%) were greater than those of aesthetic breast surgery (2.66%; P < .001) but did not significantly differ from abdominal procedures (9.75%; P = .530). Nearly 77% of combined cases were classified as low-risk (0 points total) with a 9.78% complication rates. Medium-risk patients (1 to 3 points) had a 16.63% complication rate, and high-risk (4 to 7 points) 38.46%. CONCLUSIONS: Combining abdominal and breast procedures is safe in the majority of patients and does not increase 30-day complications rates. The risk stratification tool can continue to ensure favorable outcomes for patients who may desire a combined surgery. LEVEL OF EVIDENCE: 4 Risk.


Assuntos
Abdominoplastia/métodos , Mamoplastia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Abdominoplastia/efeitos adversos , Adulto , Distribuição por Idade , Estudos de Coortes , Terapia Combinada , Estética , Feminino , Seguimentos , Humanos , Incidência , Modelos Logísticos , Mamoplastia/efeitos adversos , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Cobertura de Condição Pré-Existente , Cuidados Pré-Operatórios/métodos , Valores de Referência , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Plast Reconstr Surg Glob Open ; 3(5): e405, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26090295

RESUMO

BACKGROUND: Risk discussion is a central tenet of the dialogue between surgeon and patient. Risk calculators have recently offered a new way to integrate evidence-based practice into the discussion of individualized patient risk and expectation management. Focusing on the comprehensive Tracking Operations and Outcomes for Plastic Surgeons (TOPS) database, we endeavored to add plastic surgical outcomes to the previously developed Breast Reconstruction Risk Assessment (BRA) score. METHODS: The TOPS database from 2008 to 2011 was queried for patients undergoing breast reconstruction. Regression models were constructed for the following complications: seroma, dehiscence, surgical site infection (SSI), explantation, flap failure, reoperation, and overall complications. RESULTS: Of 11,992 cases, 4439 met inclusion criteria. Overall complication rate was 15.9%, with rates of 3.4% for seroma, 4.0% for SSI, 6.1% for dehiscence, 3.7% for explantation, 7.0% for flap loss, and 6.4% for reoperation. Individualized risk models were developed with acceptable goodness of fit, accuracy, and internal validity. Distribution of overall complication risk was broad and asymmetric, meaning that the average risk was often a poor estimate of the risk for any given patient. These models were added to the previously developed open-access version of the risk calculator, available at http://www.BRAscore.org. CONCLUSIONS: Population-based measures of risk may not accurately reflect risk for many individual patients. In this era of increasing emphasis on evidence-based medicine, we have developed a breast reconstruction risk assessment calculator from the robust TOPS database. The BRA Score tool can aid in individualizing-and quantifying-risk to better inform surgical decision making and better manage patient expectations.

8.
Ann Plast Surg ; 74(2): 157-62, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25590251

RESUMO

BACKGROUND: The National Surgical Quality Improvement Program (NSQIP) and the Tracking Operations and Outcomes for Plastic Surgeons (TOPS) registries gather outcomes for plastic surgery procedures. The NSQIP collects hospital data using trained nurses, and the TOPS relies on self-reported data. We endeavored to compare the TOPS and NSQIP data sets with respect to cohort characteristics and outcomes to better understand the strengths and weakness of each registry as afforded by their distinct data collection methods. STUDY DESIGN: The 2008 to 2011 TOPS and NSQIP databases were queried for breast reductions and breast reconstructions. Propensity score matching identified similar cohorts from the TOPS and NSQIP databases. Shared 30-day surgical and medical complications rates were compared across matched cohorts. RESULTS: The TOPS captured a significantly greater number of wound dehiscence occurrences (4.77%-5.47% vs 0.69%-1.17%, all P<0.001), as well as more reconstructive failures after prosthetic reconstruction (2.82% vs 0.26%, P<0.001). Medical complications were greater in NSQIP (P<0.05). Other complication rates did not differ across any procedure (all P>0.05). CONCLUSIONS: The TOPS and NSQIP capture significantly different patient populations, with TOPS' self-reported data allowing for the inclusion of private practices. This self-reporting limits TOPS' ability to identify medical complications; surgical complications and readmissions, however, were not underreported. Many surgical complications are captured by TOPS at a higher rate due to its broader definitions, and others are not captured by NSQIP at all. The TOPS and NSQIP provide complementary information with different strengths and weakness that together can guide evidence-based decision making in plastic surgery.


Assuntos
Mamoplastia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros/normas , Adulto , Estudos de Coortes , Feminino , Humanos , Mamoplastia/métodos , Mamoplastia/normas , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Pontuação de Propensão , Melhoria de Qualidade , Autorrelato , Estados Unidos
9.
JAMA Surg ; 150(2): 110-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25472485

RESUMO

IMPORTANCE: There is a paucity of data assessing the effect of increased surgical duration on the incidence of venous thromboembolism (VTE). OBJECTIVE: To examine the association between surgical duration and the incidence of VTE. DESIGN, SETTINGS, AND PARTICIPANTS: Retrospective cohort of 1,432,855 patients undergoing surgery under general anesthesia at 315 US hospitals participating in the American College of Surgeons National Surgical Quality Improvement Program from 2005 to 2011. EXPOSURE: Duration of surgery. MAIN OUTCOMES AND MEASURES: The rates of deep vein thrombosis (DVT), pulmonary embolism (PE), and VTE within 30 days of the index operation. Surgical duration was standardized across Current Procedural Terminology codes using a z score. Outcomes were compared across quintiles of the z score. Multiple logistic regression models were developed to examine the association while adjusting for patient demographics, clinical characteristics, and comorbidities. RESULTS: The overall VTE rate was 0.96% (n = 13,809); the rates of DVT and PE were 0.71% (n = 10,198) and 0.33% (n = 4772), respectively. The association between surgical duration and VTE increased in a stepwise fashion. Compared with a procedure of average duration, patients undergoing the longest procedures experienced a 1.27-fold (95% CI, 1.21-1.34; adjusted risk difference [ARD], 0.23%) increase in the odds of developing a VTE; the shortest procedures demonstrated an odds ratio of 0.86 (95% CI, 0.83-0.88; ARD, -0.12%). The robustness of these results was substantiated with several sensitivity analyses attempting to minimize the effect of outliers, concurrent complications, procedural differences, and unmeasured confounding variables. CONCLUSIONS AND RELEVANCE: Among patients undergoing surgery, an increase in surgical duration was directly associated with an increase in the risk for VTE. These findings may help inform preoperative and postoperative decision making related to surgery.


Assuntos
Duração da Cirurgia , Complicações Pós-Operatórias , Embolia Pulmonar/epidemiologia , Tromboembolia Venosa/epidemiologia , Trombose Venosa/epidemiologia , Adulto , Idoso , Bases de Dados Factuais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Estados Unidos
10.
J Plast Surg Hand Surg ; 49(4): 191-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25423609

RESUMO

BACKGROUND: Venous thromboembolism (VTE) is a significant cause of morbidity and mortality, particularly in the postoperative setting. Various risk stratification schema exist in the plastic surgery literature, but do not take into account variations in procedure length. The putative risk of VTE conferred by increased length of time under anaesthesia has never been rigorously explored. AIM: The goal of this study is to assess this relationship and to benchmark VTE rates in plastic surgery. METHODS: A large, multi-institutional quality-improvement database was queried for plastic and reconstructive surgery procedures performed under general anaesthesia between 2005-2011. In total, 19,276 cases were abstracted from the database. Z-scores were calculated based on procedure-specific mean surgical durations, to assess each case's length in comparison to the mean for that procedure. A total of 70 patients (0.36%) experienced a post-operative VTE. Patients with and without post-operative VTE were compared with respect to a variety of demographics, comorbidities, and intraoperative characteristics. Potential confounders for VTE were included in a regression model, along with the Z-scores. RESULTS: VTE occurred in both cosmetic and reconstructive procedures. Longer surgery time, relative to procedural means, was associated with increased VTE rates. Further, regression analysis showed increase in Z-score to be an independent risk factor for post-operative VTE (Odds Ratio of 1.772 per unit, p-value < 0.001). Subgroup analyses corroborated these findings. CONCLUSIONS: This study validates the long-held view that increased surgical duration confers risk of VTE, as well as benchmarks VTE rates in plastic surgery procedures. While this in itself does not suggest an intervention, surgical time under general anaesthesia would be a useful addition to existing risk models in plastic surgery.


Assuntos
Anestesia Geral/efeitos adversos , Duração da Cirurgia , Procedimentos de Cirurgia Plástica , Complicações Pós-Operatórias/epidemiologia , Tromboembolia Venosa/epidemiologia , Adulto , Técnicas Cosméticas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Análise de Regressão , Fatores de Risco , Estados Unidos/epidemiologia
11.
Plast Reconstr Surg Glob Open ; 2(11): e255, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25506538

RESUMO

BACKGROUND: Although recent literature suggests that patients with Medicaid and Medicare are more likely than those with private insurance to experience complications following a variety of procedures, there has been limited evaluation of insurance-based disparities in reconstructive surgery outcomes. Using a large, multi-institutional database, we sought to evaluate the potential impact of insurance status on complications following breast reconstruction. METHODS: We identified all breast reconstructive cases in the 2008 to 2011 Tracking Operations and Outcomes for Plastic Surgeons clinical registry. Propensity scores were calculated for each case, and insurance cohorts were matched with regard to demographic and clinical characteristics. Outcomes of interest included 15 medical and 13 surgical complications. RESULTS: Propensity-score matching yielded 493 matched patients for evaluation of Medicaid and 670 matched patients for evaluation of Medicare. Overall complication rates did not significantly differ between patients with Medicaid or Medicare and those with private insurance (P = 0.167 and P = 0.861, respectively). Risk-adjusted multivariate regressions corroborated this finding, demonstrating that Medicaid and Medicare insurance status does not independently predict surgical site infection, seroma, hematoma, explantation, or wound dehiscence (all P > 0.05). Medicaid insurance status significantly predicted flap failure (odds ratio = 3.315, P = 0.027). CONCLUSIONS: This study is the first to investigate the differential effects of payer status on outcomes following breast reconstruction. Our results suggest that Medicaid and Medicare insurance status does not independently predict increased overall complication rates following breast reconstruction. This finding underscores the commitment of the plastic surgery community to providing consistent care for patients, irrespective of insurance status.

12.
Plast Reconstr Surg ; 134(3): 351e-362e, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24814422

RESUMO

BACKGROUND: Risk factors for surgical-site infection following beast reconstruction have been thoroughly investigated at a population level. However, traditional population-based measures may not always capture the nuances of individual patients. The authors aimed to develop a validated breast reconstruction risk assessment calculator for surgical-site infection that informs risk at an individual level. METHODS: Mastectomies with immediate reconstruction (n = 16,069) from 2005 to 2011 were identified from the National Surgical Quality Improvement Program database. A multiple logistic regression model was created for postoperative surgical-site infection. Hosmer-Lemeshow, C statistic, and Brier score were computed to assess model performance. Bootstrap analysis validated the model. RESULTS: A robust, validated risk model for surgical-site infection was developed using 11 covariates. The model Hosmer-Lemeshow p value was 0.371, the Brier score was 0.0357, and the C statistic was 0.682 (optimism-corrected C statistic, 0.678). The distribution of individual risks demonstrated a positive skew. Population-derived risk underestimated or overestimated individual risk by at least 1.5-fold in nearly one-fifth of all patients. CONCLUSIONS: The breast reconstruction risk assessment score risk calculator for surgical-site infection mitigates the potentially inaccurate interpolation of population-based risk to individual patients. The authors concomitantly developed an online interface-accessible by patients and surgeons alike-to quantify a patient's risk for surgical-site infection, better informing evidence-based decisions and managing patient expectations. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.


Assuntos
Técnicas de Apoio para a Decisão , Mamoplastia , Medicina de Precisão , Infecção da Ferida Cirúrgica/prevenção & controle , Adulto , Idoso , Bases de Dados Factuais , Feminino , Humanos , Modelos Logísticos , Mastectomia , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Infecção da Ferida Cirúrgica/etiologia
13.
J Plast Surg Hand Surg ; 48(5): 322-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24495186

RESUMO

Tissue expander placement is a mainstay of reconstructive surgery in the post-mastectomy patient. Necrosis of the native breast tissue is one of the most significant concerns in their post-operative care. The goal of this study is to elucidate factors that confer risk of this outcome. Chart review was conducted for a consecutive series of immediate tissue expander reconstructions by the two senior authors. Data was collected for several preoperative and intraoperative variables, as well as the outcome of mastectomy flap necrosis. Of the 1566 breasts that were examined, 135 (8.6%) experienced flap necrosis. The cohorts with and without flap necrosis were well matched. Those with the outcome of interest had significantly higher rates of switching to an autologous method of reconstruction (31.9% vs 6.2%, p < 0.001). Regression analysis revealed smoking status, increased age, tumescent mastectomy technique, and high (>66.67%) intraoperative tissue expander fill to confer increased risk of mastectomy flap necrosis. While smoking and older age are well-supported by the literature, tumescent technique and tissue expander fill are more novel points of discussion, which may serve as proxies for other issues. Awareness of these risk factors and their interplay will aid in clinical judgement and postoperative care of these patients.


Assuntos
Mamoplastia/efeitos adversos , Retalhos Cirúrgicos/efeitos adversos , Retalhos Cirúrgicos/patologia , Dispositivos para Expansão de Tecidos/efeitos adversos , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Intervalos de Confiança , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Mamoplastia/métodos , Mastectomia/efeitos adversos , Mastectomia/métodos , Pessoa de Meia-Idade , Necrose/etiologia , Necrose/cirurgia , Razão de Chances , Complicações Pós-Operatórias/patologia , Complicações Pós-Operatórias/cirurgia , Período Pós-Operatório , Análise de Regressão , Reoperação/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
J Reconstr Microsurg ; 30(2): 103-14, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24114710

RESUMO

Although often a life-saving therapeutic maneuver, there is minimal data available that details the effects of intraoperative packed red blood cell transfusion (IOT) after microvascular free tissue transfer. The National Surgical Quality Improvement Program database was queried to identify all patients who underwent microvascular free tissue transfer between 2006 and 2010. Multivariate logistic regression models were used to determine the association between intraoperative transfusion and outcomes. Upon bivariate and multivariate analyses, IOT was significantly associated with higher rates of overall complications (odds ratio [OR], 2.02; 95% confidence interval [CI], 1.12-3.63), medical complications (OR, 3.35; 95% CI, 1.75-6.42), postoperative transfusion (OR, 6.02; 95% CI, 2.02-17.97), and reoperation (OR, 2.24; 95% CI, 1.24-4.04). IOT was not associated with either surgical complications or free flap loss. IOT significantly increases risk for adverse overall and medical complications. However, IOT was not associated with surgical complications or free flap loss. Transfusion practices in the operating room should be reevaluated to improve overall outcomes.


Assuntos
Transfusão de Sangue , Retalhos de Tecido Biológico , Cuidados Intraoperatórios/métodos , Complicações Intraoperatórias/terapia , Complicações Pós-Operatórias/terapia , Procedimentos Cirúrgicos Vasculares , Transfusão de Sangue/métodos , Transfusão de Sangue/mortalidade , Feminino , Retalhos de Tecido Biológico/irrigação sanguínea , Humanos , Complicações Intraoperatórias/mortalidade , Masculino , Pessoa de Meia-Idade , Razão de Chances , Complicações Pós-Operatórias/mortalidade , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos , Procedimentos Cirúrgicos Vasculares/mortalidade
15.
Ann Surg Oncol ; 21(2): 384-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24121881

RESUMO

BACKGROUND: Despite the growing interest in the advantages of tumescent mastectomy technique, there remain concerns that tumescent solution may increase postoperative complication rates. This study evaluates patient outcomes following tumescent mastectomy in the setting of immediate prosthetic reconstruction. METHODS: Retrospective review of 1,491 breasts (1,030 patients) treated by 4 oncologic and 2 reconstructive surgeons between 2004 and 2012 at a single institution. The primary outcomes of interest included seroma, hematoma, infection, and mastectomy flap necrosis, as well as conversion to autologous reconstruction. Multiple logistic regression was used to determine the adjusted influence of tumescence on outcomes. RESULTS: The tumescent cohort (n = 890 breasts) was younger and experienced lower rates of preoperative radiation than the nontumescent cohort (n = 601 breasts). Mean follow-up was 21.2 months. While tumescent procedures were on average 20 min faster, postoperative complication rates did not significantly differ between cohorts. Regression analysis controlling for potential confounders, including differences in surgeon technique, failed to identify tumescent mastectomy as an independent risk factor for complication [odds ratio (OR) = 1.2, 95% confidence interval (CI) = 0.8-1.8, p = 0.385]. Individually, neither seroma, hematoma, infection, nor flap necrosis was affected significantly by the use of tumescence (OR = 1.66, 95% CI = 0.73-3.78, p = 0.229; OR = 1.11, 95% CI = 0.42-2.95, p = 0.837; OR = 0.84, 95% CI = 0.4-1.75, p = 0.689; OR = 1.19, 95% CI = 0.7-2.03, p = 0.67, respectively). DISCUSSION: This longitudinal study is well equipped to assess the influence of tumescent mastectomy technique in the hands of experienced and high-volume oncologic surgeons on postoperative outcomes. Our analysis suggests that in the setting of an immediate prosthetic reconstruction, tumescent mastectomy does not independently affect postoperative complication rates.


Assuntos
Anestésicos Locais/administração & dosagem , Neoplasias da Mama/cirurgia , Mamoplastia , Mastectomia/métodos , Complicações Pós-Operatórias/epidemiologia , Neoplasias da Mama/patologia , Chicago/epidemiologia , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Retalhos Cirúrgicos , Resultado do Tratamento
18.
Ann Plast Surg ; 71(4): 335-41, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24025652

RESUMO

BACKGROUND: Recent health care legislation institutes penalties for surgical readmissions secondary to complications. There is a paucity of evidence describing risk factors for readmission after breast reconstruction procedures. METHODS: Patients undergoing breast reconstruction in 2011 were identified in the National Surgical Quality Improvement Program database. Patients were grouped as purely immediate implant/tissue-expander reconstructions or purely autologous reconstruction for analysis. Reconstructions involving multiple types of procedures were excluded due to difficulty with classification. Perioperative variables were analyzed using χ and Student t test as appropriate. Multivariate regression modeling was used to identify risk factors for readmission. RESULTS: Of 5012 patients meeting inclusion criteria, 3960 and 1052 underwent implant/expander and autologous reconstructions, respectively. Implant/expander and autologous cohorts experienced similar readmission rates (4.34% vs 5.32%, respectively; P = 0.18). However, autologous reconstructions experienced a higher rate of overall complications than implant/expander reconstructions (19.96% vs 5.86%, respectively; P < 0.05), as well as higher rates of reoperation (9.7% vs 6.5%, respectively; P < 0.05). Common predictors of readmission for implant/expander and autologous cohorts included operative time, American Society of Anesthesiologist class 3 and 4, and superficial surgical site infection. Smoking, sepsis, deep wound infection, organ space infection, and wound disruption were predictive of readmission for implant/expander reconstruction only, whereas hypertension was predictive of readmission after autologous reconstruction only. CONCLUSIONS: This is the first study of readmission rates after breast reconstruction. Knowledge of specific risk factors for readmission may improve patient outcomes, steer strategies for optimizing reconstructive outcomes, and minimize readmissions.


Assuntos
Mamoplastia , Readmissão do Paciente/estatística & dados numéricos , Adulto , Implante Mamário/instrumentação , Implantes de Mama , Neoplasias da Mama/cirurgia , Bases de Dados Factuais , Técnicas de Apoio para a Decisão , Feminino , Humanos , Modelos Logísticos , Mamoplastia/instrumentação , Mamoplastia/métodos , Mastectomia , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Retalhos Cirúrgicos/transplante , Dispositivos para Expansão de Tecidos , Resultado do Tratamento
19.
Microsurgery ; 33(6): 432-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23836610

RESUMO

BACKGROUND: Thrombosis is a common cause of flap failure in microvascular tissue transfer, which questions the effects of anemia on this outcome. This article seeks to contribute a large, multi-institutional data analysis to this debate. METHODS: Free tissue transfer patients were identified in the National Surgical Quality Improvement database through a specified Current Procedural Terminology algorithm. Bivariate analysis compared anemic and nonanemic groups with respect to flap failure and other outcomes. Multivariable logistic regression was used to determine risk factors for flap failure. RESULTS: Of the 864 patients who met inclusion criteria, 244 were anemic and 620 were not. Bivariate analysis showed no significant difference between groups with respect to flap failure (3.28% vs. 4.03%, P = 0.0603). Multivariate regression analysis supported this (OR 95% CI = 0.371-1.912). CONCLUSIONS: These findings, based on the largest sample in the literature, show anemia is neither a predictor of free tissue transfer failure nor is it protective.


Assuntos
Anemia/complicações , Retalhos de Tecido Biológico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anemia/epidemiologia , Índice de Massa Corporal , Current Procedural Terminology , Feminino , Retalhos de Tecido Biológico/irrigação sanguínea , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos , Fatores de Risco , Falha de Tratamento , Trombose Venosa/complicações , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA