Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Gut ; 73(11): 1816-1822, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39122363

RESUMO

INTRODUCTION: The environmental impact of endoscopy is a topic of growing interest. This study aimed to compare the carbon footprint of performing an esogastroduodenoscopy (EGD) with a reusable (RU) or with a single-use (SU) disposable gastroscope. METHODS: SU (Ambu aScope Gastro) and RU gastroscopes (Olympus, H190) were evaluated using life cycle assessment methodology (ISO 14040) including the manufacture, distribution, usage, reprocessing and disposal of the endoscope. Data were obtained from Edouard Herriot Hospital (Lyon, France) from April 2023 to February 2024. Primary outcome was the carbon footprint (measured in Kg CO2 equivalent) for both gastroscopes per examination. Secondary outcomes included other environmental impacts. A sensitivity analysis was performed to examine the impact of varying scenarios. RESULTS: Carbon footprint of SU and RU gastroscopes were 10.9 kg CO2 eq and 4.7 kg CO2 eq, respectively. The difference in carbon footprint equals one conventional car drive of 28 km or 6 days of CO2 emission of an average European household. Based on environmentally-extended input-output life cycle assessment, the estimated per-use carbon footprint of the endoscope stack and washer was 0.18 kg CO2 eq in SU strategy versus 0.56 kg CO2 eq in RU strategy. According to secondary outcomes, fossil eq depletion was 130 MJ (SU) and 60.9 MJ (RU) and water depletion for 6.2 m3 (SU) and 9.5 m3 (RU), respectively. CONCLUSION: For one examination, SU gastroscope have a 2.5 times higher carbon footprint than RU ones. These data will help with the logistics and planning of an endoscopic service in relation to other economic and environmental factors.


Assuntos
Pegada de Carbono , Equipamentos Descartáveis , Reutilização de Equipamento , Gastroscópios , Humanos , Endoscopia do Sistema Digestório/instrumentação , França
3.
Endoscopy ; 56(10): 737-746, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38657660

RESUMO

INTRODUCTION: The environmental impact of endoscopy, including small-bowel capsule endoscopy (SBCE), is a topic of growing attention and concern. This study aimed to evaluate the greenhouse gas (GHG) emissions (kgCO2) generated by an SBCE procedure. METHODS: Life cycle assessment methodology (ISO 14040) was used to evaluate three brands of SBCE device and included emissions generated by patient travel, bowel preparation, capsule examination, and video recording. A survey of 87 physicians and 120 patients was conducted to obtain data on travel, activities undertaken during the procedure, and awareness of environmental impacts. RESULTS: The capsule itself (4 g) accounted for < 6 % of the total product weight. Packaging (43-119 g) accounted for 9 %-97 % of total weight, and included deactivation magnets (5 g [4 %-6 %]) and paper instructions (11-50 g [up to 40 %]). A full SBCE procedure generated approximately 20 kgCO2, with 0.04 kgCO2 (0.2 %) attributable to the capsule itself and 18 kgCO2 (94.7 %) generated by patient travel. Capsule retrieval using a dedicated device would add 0.98 kgCO2 to the carbon footprint. Capsule deconstruction revealed materials (e. g. neodymium) that are prohibited from environmental disposal; 76 % of patients were not aware of the illegal nature of capsule disposal via wastewater, and 63 % would have been willing to retrieve it. The carbon impact of data storage and capsule reading was negligible. CONCLUSION: The carbon footprint of SBCE is mainly determined by patient travel. The capsule device itself has a relatively low carbon footprint. Given that disposal of capsule components via wastewater is illegal, retrieval of the capsule is necessary but would likely be associated with an increase in device-related emissions.


Assuntos
Endoscopia por Cápsula , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Endoscopia por Cápsula/instrumentação , Intestino Delgado/diagnóstico por imagem , Pegada de Carbono , Viagem , Cápsulas Endoscópicas , Gases de Efeito Estufa/efeitos adversos , Gases de Efeito Estufa/análise , Masculino , Adulto , Feminino
4.
Endosc Int Open ; 11(7): E635-E640, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37928772

RESUMO

Background and study aims What distinguishes endoscopic submucosal dissection (ESD) from endoscopic mucosal resection is the need for three foot pedals to activate the electrosurgical unit, flushing and knife injection. The lack of connection between the various pedals of different shapes and brands leads to numerous pedals displacements and potential mistakes. The aim of this study was to evaluate an Innovative PEdal FIXator (IPEFIX) to reduce pedal mistakes during ESD. Methods This was a prospective, multicenter, randomized study. Consecutive ESD procedures were randomly assigned to two groups: a control group with the three pedals free and the IPEFIX group in which the three pedals were linked by IPEFIX. The main outcome evaluated was the number of foot mistakes (wrong pedal, foot push beside the pedal). Results A total of 107 ESDs were performed by eight experts in five centers. The median number of mistakes per hour of ESD procedure was 0/h in the IPEFIX group and 1.9/h in the control group ( P <0.001). The mean number of times to look down to control the position of the pedals was 2.2/h the IPEFIX group and 7.7/h in the control group ( P <0.001). Mean replacements of the pedals were 0./h in the IPEFIX group and 1.7/h in the control group ( P <0.001). Similar results were obtained in trainees in simulated ESD on animal models. Conclusions IPEFIX is a simple device to connect different pedals during endoscopic procedures. It helps to reduce the numbers of foot mistakes during ESD and improves operator comfort.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA