Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 42(2): 216-221, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29189395

RESUMO

PURPOSE: The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol. MATERIALS AND METHODS: A total of 200 patients with possible urinary tract abnormalities were equally divided between 2 protocols. Protocol A used the conventional single bolus and quadruple-phase scan protocol (pre, arterial, venous, and delayed), retrospectively. Protocol B included a quadruple-phase contrast media injection with a triphasic scan protocol (pre, arterial and combined venous, and delayed), prospectively. Each protocol used 100 mL contrast and saline at a flow rate of 4.5 mL. Attenuation profiles and contrast-to-noise ratio of the renal arteries, veins, and urogenital tract were measured. Effective radiation dose calculation, data analysis by independent sample t test, receiver operating characteristic, and visual grading characteristic analyses were performed. RESULTS: In arterial circulation, only the inferior interlobular arteries in both protocols showed a statistical significance (P < 0.05). Venously, the inferior vena cava, proximal and distal renal veins demonstrated a significant opacification reduction in protocol B than in protocol A (P < 0.001). Protocol B showed a significantly higher mean contrast-to-noise ratio than protocol A (protocol B: 22.68 ± 13.72; protocol A: 14.75 ± 5.76; P < 0.001). Radiation dose was significantly reduced in protocol B (7.38 ± 2.22 mSv) than in protocol A (12.28 ± 2.72 mSv) (P < 0.001). Visual grading characteristic (P < 0.027) and receiver operating characteristic (P < 0.0001) analyses demonstrated a significant preference for protocol B. CONCLUSIONS: In computed tomography urography, augmented quadruple-phase contrast media and triphasic scan protocol usage increases the image quality at a reduced radiation dose.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sistema Urinário/diagnóstico por imagem
2.
Am J Emerg Med ; 36(4): 589-593, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29055617

RESUMO

OBJECTIVE: To evaluate the performance of non-contrast computed tomography (CT) by reporting the difference in attenuation between normal and inflamed renal parenchyma in patients clinically diagnosed with acute pyelonephritis (APN). MATERIAL AND METHODS: This is a retrospective study concerned with non-contrast CT evaluation of 74 patients, admitted with a clinical diagnosis of APN and failed to respond to 48h antibiotics treatment. Mean attenuation values in Hounsfield units (HU) were measured in the upper, middle and lower segments of the inflamed and the normal kidney of the same patient. Independent t-test was performed for statistical analysis. Image evaluation included receiver operating characteristic (ROC), visual grading characteristic (VGC) and kappa analyses. RESULTS: The mean attenuation in the upper, middle and lower segments of the inflamed renal cortex was 32%, 25%, and 29% lower than the mean attenuation of the corresponding cortical segments of the contralateral normal kidney, respectively (p<0.01). The mean attenuation in the upper, middle, and lower segments of the inflamed renal medulla was 48%, 21%, and 30%, lower than the mean attenuation of the corresponding medullary segments of the contralateral normal kidney (p<0.02). The mean attenuation between the inflamed and non-inflamed renal cortex and medulla was 29% and 30% lower respectively (p<0.001). The AUCROC (p<0.001) analysis demonstrated significantly higher scores for pathology detection, irrespective of image quality, compared to clinical and laboratory results with an increased inter-reader agreement from poor to substantial. CONCLUSION: Non-contrast CT showed a significant decrease in the parenchymal density of the kidney affected with APN in comparison to the contralateral normal kidney of the same patient. This can be incorporated in the diagnostic criteria of APN in NCCT in the emergency setting.


Assuntos
Rim/diagnóstico por imagem , Pielonefrite/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Doença Aguda , Adulto , Feminino , Humanos , Líbano , Masculino , Pessoa de Meia-Idade , Pielonefrite/fisiopatologia , Curva ROC , Doses de Radiação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA